Engine Fire Protection System

Similar documents
Bombardier Challenger Fire Protection

Fire Extinguishing System

DASSAULT AVIATION Proprietary Data

SECTION 6-15 FIRE PROTECTION

SECTION 2-07 FIRE PROTECTION

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION

Fokker 50 - Fire Protection

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

TABLE OF CONTENTS FIRE PROTECTION. Page. 9-i

Section - III SYSTEMS DESCRIPTION

FIRE PROTECTION TABLE OF CONTENTS CHAPTER 9

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

DASSAULT AVIATION Proprietary Data

DC3Training.com N28AA DC-3 Pilot s Handbook

DASSAULT AVIATION Proprietary Data

Dornier 328Jet - Lights

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29

Pressurization System

DASSAULT AVIATION Proprietary Data

SAFETY INFORMATION NOTICE

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

Section - III SYSTEMS DESCRIPTION

Canadair Regional Jet 100/200 - Lighting

Canadair Regional Jet 100/200 - Water & Waste

OWNERS MANUAL MODEL 451 (-101 & -201)

CHAPTER 11 AIR CONDITIONING

FIRE EXTINGUISHING SYSTEM

Section - III SYSTEMS DESCRIPTION

Instrument and Control Panels

United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006

Memory Items 2

Element C3.4 Fire Fighting Equipment

Basic Vehicle Fire Protection Manual

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

SD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)

Fokker 50 - Integrated Alerting Unit

Service Bulletin No. 2930

Kelsow Work Instruction. Buffalo Venture FPSO Fire Protection Systems

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

A380 Special Condition D 04 Crew Rest Compartment

System Test Report CLEAN AGENT

1 Aviation English Vocabulary Level 4 to 5

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

End To End Optical Beam Smoke Detector. Additional Information

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Hazardous Material Safety Program

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Section 11. Heating and Ventilation. Heating & Ventilation Systems. 1 of 6

CIRRUS AIRPLANE MAINTENANCE MANUAL

Analog Room Pressure Monitor RPC Series

Fire Safety and Utility Controls. CERT Basic Training Unit 2

SERVICE BULLETIN REVISION

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

Intelligent Security & Fire Ltd

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Fire Safety and Utility Controls. CERT Basic Training Unit 2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Installation Guide for inbiox60 Series Access Control Panel

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

1987 FALCON 900B SN 33

P.68 VARIANTS. SERVICE BULLETIN No. 195 Rev. 1 (Supersedes the previous issue dated 19 February 2014)

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft

Agent Tanks PCL PCL PCL PCL - 600

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

Installation and Operation Manual AEC9005 Series Low Voltage Warning and Auxiliary Battery Management Modules

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

MINIMUM EQUIPMENT LIST ATA 33 - LIGHT F-27 Mk 050

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

CESCOM 20 - Projected Maintenance Due

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

2009 HAWKER 4000 RC-22

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Chapter 26 FIRE PROTECTION

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

Motorised Infrared Optical Beam Smoke Detector. User Guide

2004 CITATION X. Registration: N228DB Serial Number: Asking Price: Make Offer

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

FA-101U Fire Alarm Control Panel

TABLE OF CONTENTS PART 4 - HAND TOOLS AND POWER DRIVEN PORTABLE TOOLS

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

CHAPTER 11 HEATING AND VENTILATION

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

CLEANROOM MONITOR CR3A Network - Installation Instructions

Motorised Infrared Optical Beam Smoke Detector. User Guide

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Transcription:

Engine Fire Protection System 1 1 LEFT FEED BUS LEFT CB PANEL CROSSOVER RIGHT FEED LEFT CB PANEL Fire Protection ARM UNLOCK DEPLOY S T EMER O W S NORM W BOTTLE 1 ARMED PUSH LH ENG FIRE PUSH RH ENG FIRE PUSH BOTTLE 2 ARMED PUSH S EMER T O W NORM S W ARM UNLOCK DEPLOY HYD F/W LH FUEL F/W LH FIRE DET FAIL LH RH FUEL VALVE L R HYDRAULIC VALVE FIRE CONTROL UNIT TEE CHECK VALVE SQUIB SQUIB 1 2 SQUIB SQUIB T / R ISOLATION VALVE FIRE DETECTOR LOOP FIRE EXT BOTTLE LOW 1 UNITS 0152 AND SUBSEQUENT, BOTH SIDES OF THE SYSTEM RECEIVE 28V DC FROM THE EMERGENCY BUS THROUGH SEPARATE 2 AMP CBs TEE CHECK VALVE PRESSURE SWITCH FUEL PRESSURE HYDRAULIC PRESSURE HALON 1301 FIRE LOOP Citation III/VI For training only 4D-1

Engine Fire Detection System LEFT ENGINE FIRE PUSH SWITCH THRUST REVERSER HYDRAULIC CUTOFF LEFT THRUST REVERSER ISOLATION VALVE GENERATOR TRIP TRIP LEFT GENERATOR CONTROL UNIT CUTOFF LEFT FUEL AND HYDRAULIC CUTOFF VALVES HYD F/W LH FUEL F/W LH ARM BOTTLE NUMBER 1 PUSH TO FIRE LOW PRESSURE ARM BOTTLE NUMBER 2 BOTTLE NUMBER 1 ARMED SWITCH EXTINGUISHER BOTTLE NUMBER 1 RIGHT ENGINE FIRE PUSH SWITCH FIRE EXT BOTTLE LOW ARM BOTTLE NUMBER 1 BOTTLE NUMBER 2 ARMED SWITCH EXTINGUISHER BOTTLE NUMBER 2 ARM BOTTLE NUMBER 2 PUSH TO FIRE RIGHT FUEL AND HYDRAULIC CUTOFF VALVES LOW PRESSURE HYD F/WI RH CUTOFF FUEL F/W RH GENERATOR TRIP TRIP RIGHT GENERATOR CONTROL UNIT THRUST REVERSER HYDRAULIC CUTOFF RIGHT THRUST REVERSER ISOLATION VALVE 4D-2 For training only Citation III/VI

Fire Detection Engine Fire Protection The engine fire detection system consists of a stainless steel sensing tube that wraps around the engine combustion section and accessory section. A responder assembly connected to the sensing tube has two pressure switches: alarm responder and integrity responder. When subjected to high temperatures, the inert gas in the sensing tube expands and exerts pressure against the alarm responder switch. When the switch closes, it completes a circuit within the fire detection control unit box to illuminate the respective LH/RH ENG FIRE PUSH switchlight and sound the fire bell. After three seconds, a time delay relay silences the fire bell. If the sensing tube develops a leak and the inert gas escapes, the loss of pressure opens the normally closed integrity responder pressure switch to illuminate the respective amber LH/RH DET FAIL annunciator. APU On aircraft with a Turbomach APU, the fire detection system consists of a fire detection loop that surrounds the APU powerplant. On flight operable APUs, an additional fire detection loop mounts to the inside of the APU enclosure. As a fire or bleed air leak heats the fire detection loop(s), resistance of the loop decreases until current flows from its core to its outer sheath to complete a circuit to the fire control unit. The fire control unit then illuminates the APU FIRE switchlight, triggers the flashing Master Warning lights, and sounds the fire bell. Citation III/VI For training only 4D-3

On aircraft with the Duncan installed GTCP36-150W APU, the fire detection system consists of four spot detectors strategically located on the APU and APU enclosure. If a fire or bleed air leak occurs, the spot detectors trigger the flashing APU control panel APU FIRE PUSH switchlight and the Master Warning lights and sound the fire bell. Pressing the APU FIRE PUSH switchlight closes the APU fuel shutoff valve, arms the fire extinguishing system, and initiates an automatic APU shutdown. Pressing the FIRE TEST button tests the APU fire detection circuits. If the APU FIRE PUSH switchlight and Master Warning lights flash and the fire bell sounds, the system is operating normally. Smoke A smoke detector under the aft cabin floor near the outflow provides cabin fire detection. If a cabin fire develops, smoke in the air exiting the outflow valve triggers the smoke detector. The detector operating on 28V DC from the Crossover Left Feed bus illuminates the SMOKE DETECT annunciator and triggers the Master Warning lights. Testing Placing the rotary TEST switch in SMOKE FIRE WARN tests the engine and cabin fire detection systems. Illumination of the ENG FIRE PUSH switchlights and SMOKE DETECT annunciator, sounding of the fire bell, and flashing Master Warning lights denotes proper system operation. 4D-4 For training only Citation III/VI

Fire Extinguishing Engine Fire Protection Two dual-head single-shot fire extinguisher bottles in the tail compartment contain Halon 1301 (bromotrifluoromethane) pressurized with nitrogen. Each bottle has a temperature compensating switch, a combination fill and safety valve outlet, and two discharge valves and outlets. When the fire detection system senses an engine fire or overheat, it illuminates the associated ENG FIRE PUSH switchlight, triggers the flashing Master Warning lights, and sounds the fire bell for three seconds. Pressing the ENG FIRE PUSH switchlight arms the fire extinguishing system (BOTTLE 1/2 ARMED PUSH switchlights illuminated). This action also closes the fuel and hydraulic firewall valves, trips the affected engine s generator offline, and closes the thrust reverser isolation valve. Pushing the BOTTLE 1 or 2 ARMED PUSH switchlight supplies 28V DC to fire the explosive cartridge and release bottle contents to the affected engine. Pressurized nitrogen carries the fire extinguishing agent from the bottle through distribution lines to the engine nacelle. If the ENG FIRE PUSH light remains illuminated after 30 seconds, pressing the other BOTTLE ARMED PUSH switchlight discharges the other bottle into the same engine nacelle. After bottle discharge, the FIRE EXT BOTTLE LOW annunciator illuminates. If bottle pressure falls below 500 ±25 PSIG, the bottle s temperature compensating switch illuminates the FIRE EXT BOTTLE LOW annunciator. If this occurs, the bottle must be removed and serviced by an appropriate agency. The bottle also has a fusible plug in the safety valve that reacts to bottle overheat by melting and releasing bottle contents through the fill port into the tail compartment. Citation III/VI For training only 4D-5

APU Depending on the APU installed and service bulletin compliance, varying APU fire extinguishing systems are installed. This includes: units 001 to 121 with Cessna installed Turbomach APU: single bottle discharges into APU enclosure (shroud) aircraft with SB650-28-16: one bottle discharges into APU enclosure and one bottle discharges into APU air inlet ground and flight certified APUs: larger single bottle discharges into APU enclosure PATS, Inc. installed Turbomach APU: single bottle discharges into APU enclosure Duncan STC SA2110CE Garrett GTCP36-150: single bottle discharges into APU enclosure. The APU fire extinguishing bottle(s) is similar to the engine fire extinguisher bottle except that it has a single discharge outlet. A temperature compensating switch illuminates the APU FAIL light if bottle pressure drops to approximately 500 PSI. If the light illuminates, the bottle must be removed and serviced. On aircraft with SB650-28-16 and ground/flight APUs, t he extinguisher bottle(s) also has a pressure gage. When exposed to high temperatures, the APU fire detection system control unit illuminates the APU FIRE switchlight, sounds the fire bell, and energizes the time delay relay. Pressing the illuminated APU FIRE or FIRE EXT (Duncan) switchlight supplies 28V DC to fire the bottle s explosive cartridge and supply extinguishing agent to the APU enclosure. If the crew fails to act within eight seconds, the time delay relay automatically fires the explosive cartridge (except Duncan installation). 4D-6 For training only Citation III/VI

Fire Protection On aircraft with SB650-28-16, the APU fire extinguishing system automatically arms when the single-point refueling door opens or unlatches, the APU READY-TO-LOAD light illuminates (APU operating), and the left main gear squat switch indicates aircraft on ground. If the APU fails or an APU fire occurs during refueling, the fire extinguishing system automatically discharges extinguishing agent into the APU air inlet. Do not shut down the APU or close and latch the single-point refueling door before shutting down the APU. These precautions prevent inadvertent bottle discharge during refueling with the APU operating. Portable Fire Extinguishers Portable fire extinguishers in the cockpit and cabin (varies with government regulations) contain Halon 1211 (bromochlorodifluoromethane). Halon 1211 is a relatively non-toxic fire extinguishing agent that leaves no residue and is effective on most fires that occur in the aircraft. Citation III/VI For training only 4D-7

Engine Fire Protection Power Source Distribution Control Monitor Protection Left and Right Feed buses 28V DC Emergency Crossover bus (unit 152 and subsequent) Each bottle to either engine Fire control unit LH/RH ENG FIRE PUSH switchlights BOTTLE 1/2 ARMED PUSH switchlights Annunciators LH/RH ENG FIRE PUSH LH/RH FIRE DETECT FAIL FIRE EXT BOTTLE LOW LH/RH FUEL F/W LH/RH HYD F/W Fire bell SMOKE/FIRE/WARN system test Circuit breakers Bottle fusible plug 4D-8 For training only Citation III/VI

Fire Protection APU Fire Protection Power Source Distribution Control Monitor Protection Left Feed bus 28V DC APU fire extinguisher bottle(s) Fire detect sensor Distribution lines and nozzles APU enclosure (shroud) APU combustor shroud* APU air inlet* Fire control unit APU FIRE PUSH switchlight FIRE EXT switchlight (Duncan only) Time delay relay (except Duncan) APU FAIL light (low bottle pressure) APU FIRE PUSH switchlight Fire bell APU TEST PUSH switch Circuit breakers Bottle fusible plugs * Varies with APU installed. Citation III/VI For training only 4D-9

4D-10 For training only Citation III/VI