SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

Similar documents
Cooper Lighting & Safety Limited Wheatley Hall Road, Doncaster, DN2 4NB, United Kingdom

Eurofyre Limited range of ProFyre C24 Control and Indicating Equipment (refer to attached appendix for details and conditions) Certification Manager

Type 5 Certifications:

0051 CPR 0423 CONTROL AND INDICATING EQUIPMENT WITH INTEGRATED POWER SUPPLY EQUIPMENT. ELECTRICAL AUTOMATIC CONTROL AND DELAY DEVICE (optional)

Guideline Construction Products Regulation (EU) 305/20122

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

Certificate of constancy of performance,

Certificate of constancy of performance,

1. Terms defined in the Construction Products Regulation (CPR)

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

Technical Bulletin CE marking: from 1st July 2013

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

This document is a preview generated by EVS

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

Declaration of Conformity

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

C e r t i f i c a t e Of Conformity No.: 0560-CPD /AA/05

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

GNB-CPR Position Paper: Issuance of certificates under CPR

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Your Key to achieving C.E Marking Compliance

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

The Danish Energy Authority to carry out inspections in June and July 2012

Centexbel. General certification regulations. Construction products

DECLARATION OF PERFORMANCE

TFI Report Classification

Declaration of Conformity Declaration of Performance Notes

DECLARATION OF PERFORMANCE

The Machinery Directive 2006/42/EC

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

SVENSK STANDARD SS-EN 54-5/A1 2002:2016

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

Declaration of Performance

CE MARKING OF WOOD-BASED PANELS

F O C U S D O O R C L O S E R S

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

COMMISSION DELEGATED REGULATION (EU) /... of

COMMISSION DELEGATED REGULATION (EU) /... of

CE marking of fire-resistant doors the right way!

EUROPUMP ATEX Guideline Part II

GASTEC QA. Approval Requirements 31-1

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

Implementing the Construction Products Regulation (EU) 305/2011

EU-Type Examination Certificate

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

Certificate of constancy of performance

DECLARATION OF PERFORMANCE

Construction Products Directive

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

COMMISSION DELEGATED DECISION (EU) / of XXX

For structural use in all types of construction works according to EN

TFI Report Classification

DECLARATION OF PERFORMANCE. No EN

The new detector from Rafiki

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

DECLARATION OF PERFORMANCE. No EN

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

PARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

DECLARATION OF PERFORMANCE. No EN

GASTEC QA. Approval Requirements 31-2

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

TECHNICAL SPECIFICATION

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

COMMISSION DELEGATED REGULATION (EU)

YOUR GUIDE TO UNDERSTANDING CPR

Controlled Door Closing Devices

Firetect C. Fire protective products: Fire protective board

SVENSK STANDARD SS-EN 54-21:2006. Brand och räddning Branddetekteringsoch brandlarmsystem Del 21: Utrustning för larm- och felöverföring

ENGINEERING EVALUATION

Specification for Road Works Series Introduction

GASTEC QA. Approval Requirements 6

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

European Technical Assessment

EN Electrical Equipment of non-electric appliances for household and similiar purposes Safety requirements

DECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN

DECLARATION OF PERFORMANCE. No EN

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

The New EU-Regulation on Construction Products

CONFORMITY ASSESSMENT GUIDELINES. Version 1.0

European Technical Assessment ETA-00/0003 of 03/06/2016

Refrigerating Appliance ErP Test Report

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

Retention of Conformity Following Modifications of Software at the Example of Fire Alarm Equipment Industry Requirements

Transcription:

In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation), this certificate applies to the construction product(s). Product(s): Produced by or for: Produced in the manufacturing plant(s): SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions) 448 Yingchun Road, Wangchun Industrial Park, Ningbo City, China 315175 448 Yingchun Road, Wangchun Industrial Park, Ningbo City, China 315175 Intended use: Fire Safety This certificate attests that all provisions concerning the assessment and verification of constancy of performance described in Annex ZA of the standard(s): EN54-5:2000+A1:2002 Fire detection and fire alarm systems - Heat detectors - Point detectors EN54-7:2000+A1:2002+A2:2006 Fire detection and fire alarm systems - Smoke detectors - Point detectors using scattered light, transmitted light or ionization Under system 1 are applied and that the product(s) fulfils all the prescribed requirements set out above. This certificate was first issued on 02 December 2013 and will remain valid as long as the test methods and/or factory production control requirements included in the harmonised standard, used to assess the performance of the declared characteristics, do not change, and the product, and the manufacturing conditions in the plant are not modified significantly. Notified Body 0359 Intertek Testing & Certification Limited Cleeve Road, Leatherhead Surrey, KT22 7SB Tel: + 44 (0)1372 370900 Fax: +44 (0)1372 370977 E-mail: cpd.uk@intertek.com Gordon Ash Date 02/12/2013 Certification Manager and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the service must first be approved in writing by Intertek. Page 1 of 5

Appendix to Certificate of Constancy of Performance The details and condition of use for the SD119 Range of Conventional Smoke and Smoke/Heat Detectors, placed on the market by: 48 Yingchun Road, Wangchun Industrial Park, Ningbo City, China 315175 To be used in accordance with the supplier s installation instructions and in conjunction with the following bases, ancillaries, sounder tones and sensitivity settings (where applicable): Products compliant with EN54-5:2000+A1:2002: SD119-2H SD119-2HL SD119-4H(12V) SD119-4H(24V) Conventional 2 Wire Photoelectric Smoke Detector with Class A2 Heat Detector Conventional 2 Wire Photoelectric Smoke Detector with Class A2 Heat Detector and Remote LED Output Conventional 4 Wire Photoelectric Smoke Detector with Class A2 Heat Detector and 12VDC Conventional 4 Wire Photoelectric Smoke Detector with Class A2 Heat Detector and 24VDC Products compliant with EN54-7:2000+A1:2002+A2:2006: SD119-2 SD119-2L SD119-2H SD119-2HL SD119-4(12V) SD119-4(24V) SD119-4H(12V) SD119-4H(24V) Conventional 2 Wire Photoelectric Smoke Detector Conventional 2 Wire Photoelectric Smoke Detector with Remote LED Output Conventional 2 Wire Photoelectric Smoke Detector with Class A2 Heat Detector Conventional 2 Wire Photoelectric Smoke Detector with Class A2 Heat Detector and Remote LED Output Conventional 4 Wire Photoelectric Smoke Detector with 12VDC Conventional 4 Wire Photoelectric Smoke Detector with 24VDC Conventional 4 Wire Photoelectric Smoke Detector with Class A2 Heat Detector and 12VDC Conventional 4 Wire Photoelectric Smoke Detector with Class A2 Heat Detector and 24VDC Bases: 852001 Base Assembly for use with Models SD119-2 and SD119-2H 854001 Base Assembly for use with Models SD119-2L, SD119-2HL, SD119-4(12V), SD119-4(24V), SD119-4H(12V) and SD119-4H(24V) Page 2 of 5

Appendix to Certificate of Constancy of Performance (continued) Conditions of use: Suitable for indoor applications General Notes: 1. Tested under Intertek project number 100909837. 2. No CE or other type approval is made or inferred outside of the attestation of conformity and the product performance as stipulated on this certificate. Page 3 of 5

Appendix to Certificate of Constancy of Performance (continued) Table of performance for EN54-5:2000+A1:2002 Harmonised technical specification Essential characteristics Performance Clauses Notes Nominal activation conditions/sensitivity, Response delay (response time) and Performance under fire conditions Pass 4.2, 4.3, 5.2 to 5.6, 5.8, 6.1, 6.2 Operational reliability Pass 4.4 to 4.11 c Tolerance to supply voltage Pass 5.7 Durability of operational reliability and response delay; temperature resistance Pass 5.9, 5.10 a vibration resistance humidity resistance corrosion resistance electrical stability Notes: Pass 5.14 to 5.17 Pass 5.11, 5.12 Pass 5.13 Pass 5.18 Applies to Models SD119-2H, SD119-2HL, SD119-4H(12V) and SD119-4H(24V). These Models also have a declared performance relating to EN54-7:2000+A1:2002+A2:2006. a. Clauses 5.5 and 5.10 are not applicable to Class A1 and Class A2 detectors. b. Clauses 6.1 and 6.2 are only applicable to suffix S and suffix R detectors. c. The manufacturer declared that the SD119 range of detectors did not rely on software to fulfill the requirements of the standard; Clause 4.11 has therefore not been assessed. a, b Page 4 of 5

Appendix to Certificate of Constancy of Performance (continued) Table of performance for EN54-7:2000+A1:2002+A2:2006 Harmonised technical specification Essential characteristics Performance Clauses Notes Nominal activation conditions/sensitivity, Response delay (response time) and Performance under fire conditions Pass 4.8, 5.2, 5.3, 5.4, 5.6, 5.7, 5.18 Operational reliability Pass 4.2 to 4.7, 4.9 to 4.11 a Tolerance to supply voltage Pass 5.5 Durability of operational reliability and response delay; temperature resistance Pass 5.8, 5.9 vibration resistance humidity resistance corrosion resistance electrical stability Notes: Pass 5.13 to 5.16 Pass 5.10, 5.11 Pass 5.12 Pass 5.17 Applies to Models SD119-2, SD119-2L, SD119-4(12V), SD119-4(24V), SD119-2H, SD119-2HL, SD119-4H(12V) and SD119-4H(24V). Models SD119-2H, SD119-2HL, SD119-4H(12V) and SD119-4H(24V) also have a declared performance relating to EN54-5:2000+A1:2002. a. The manufacturer declared that the SD119 range of detectors did not rely on software to fulfill the requirements of the standard; Clauses 4.8 and 4.11 have therefore not been assessed. a Page 5 of 5