SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

Similar documents
FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER CONCERTINA TM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS

PRODUCT SPECIFICATION FireMaster Plus

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT SPECIFICATION FireMaster Plus Concertina

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

PRODUCT SPECIFICATION FireMaster Concertina

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

A REVOLUTIONARY APPROACH TO FIRE SAFETY

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

Technical Manual (European Standards)

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

ACTIVE FIRE CURTAINS INTISI7

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

Firetex steel fire shutters

Operation & Maintenance Manual

Fire Suppression Systems

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Üntel is ready for CPR

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

YOUR GUIDE TO UNDERSTANDING CPR

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Aspirating Smoke Detection for Large Area Coverage Applications

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

Eaton training solutions Accredited CPD seminars. LED Emergency and Mains Lighting Contents. Knowledge for your business

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

SELF PRESERVATION SOCIETY By Jim Creak

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

HART XL High Sensitivity Smoke Detection

Fire and Smoke Curtains

Model 600 Operation & Maintenance Manual

Fire Signalling. Signalling Solutions

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Your Key to achieving C.E Marking Compliance

Smoke and Fire Curtains

Schueco Fire and Smoke Protection Systems

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

HART XL High Sensitivity Smoke Detection

FIRE SAFE NOTICE BOARDS Education Buildings SPECIFYING FIRE RATED NOTICE BOARDS. Issue #1

Third Party Certification:

Building Services Brochure

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

Evolution in Emergency Lighting 7 March 2018

SMOKE AND FIRE CURTAINS

fire resistance testing

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Overhead Line Insulators

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

Protecting people, property and professional reputation

THE LEADING EDGE IN Smoke & Fire Curtains

Installation, Operating and Maintenance Manual

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Fire Signalling. Signalling Solutions

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

- CONSTRUCTION FIRE SAFETY STANDARDS

Construction Products Regulation (CPR) and BS 6701

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

SENSA MRE DDM MR

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

The Route to Third Party Certification

Fire Rated Door Assemblies: Compliant Designs

Analogue addressable devices

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Fire and Security Products and Services

K Series - Fire Suppression Systems for the Catering Industry

- CONSTRUCTION FIRE SAFETY STANDARDS

FIRE FIRE FACT NO. 057 CHECKLIST(s) : Rev. 11/2006 TITLE : CHILD CARE HOMES CHECKLIST ITEM(s) : REFERENCE(s) : K.S.A

ES 200. Sliding door operator

Remote Control Garage Doors

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

All by design. ASSA ABLOY Door Controls

UK Direction BS7671 BS 8492 BS /01/2018

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

Transcription:

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION

evacu8 THE SMOKE BARRIER SmokeStop evacu8 is a unique patented bi-roller system which has interweaving, overlapped panels as narrow as 600mm wide. Each panel overlaps the other and has its own self levelling bottom ballast system. Evacuees can simply the panels which then fall back into place, helped by the patented anti-tangle overlap retention system. The evacu8 curtain is compliant with the Equality Act. Active Smoke Barriers comprise technologically advanced fire-resistant fabric barriers encased in a compact steel housing. Barriers remain invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their fire operational position. To be compliant, Smoke Barriers must be protected from a short circuit and or total power failure, this is achieved with our patented Total Gravity Fail-Safe (TGFS) system. Smoke Barriers will control the spread of smoke in a building and protect the means of escape and create tenable conditions. WHY IS A SMOKE BARRIER REQUIRED? LIFE SAFETY - The ever increasing need for tenable conditions for life safety PREVENTION - Prevents smoke spreading, threatening life and buildings contents ESCAPE - Provides an intuituve means of escape QUICK AND EASY - Installation is quick and easy with minimal effort COMPLIANT - Equality Act compliant HIGH OCCUPANCY - Ideal for high occupancy evacuation of buildings when deployed When activated, SmokeStop evacu8 descends at safe controlled speeds in accordance with the Machinery Directive. Evacuees can then approach the barrier quickly, safely and see if anyone is coming the other way. Approved escape signs can show which panels to pass through to avoid collision and tangling. When retracting, the combination of sequential ascent, the re-aligning panel system with the divide and separating bi-roller system ensures a trouble free operation. CASE STUDY: YORK MINSTER YORK UK York Minster Revealed (YMR) is the UK s largest restoration and conservation project of its kind. This ambitious transformation of York Minsters visitor experience presented the Cathedral with a number of fire safety challenges that needed addressing prior to the opening of the Cathedrals below ground Undercroft and Treasury exhibition spaces. Appointed architects Arrol & Snell assigned Coopers to develop a system that would help protect the Cathedral s Undercroft and Treasury from smoke migration in the event of a fire. The smoke barrier system had to allow visitors to exit the Undercroft and Treasury safely, whilst preventing smoke from entering the main body of the Cathedral, but any system had to be sympathetic to its unique and ancient architecture. To meet the criteria, Coopers produced and installed four SmokeStop evacu8 Smoke Barriers developed to work with the Undercroft s visitor flow and footfall, whilst a traditional SmokeStop Smoke Barrier was installed to compartmentalise the Chambers. BENEFITS Manufactured by Coopers in the UK under ISO 9001; Products supplied are CE Marked in accordance with the Construction Products Regulations and are approved accredited under an Independent Third Party Certification scheme; Unique WALKTHRU curtain barrier technology; and PRODUCT ADVANTAGES Total Gravity Fail- Safe (TGFS) operation ensures safe rates of descent even following total power loss, wiring, short circuit or system corruption Anti-tangle, re-alignment and bi-roller overlapping system Self levelling bottom ballast system to overcome uneven floors See through panels are highly translucent for safety Unique strip retraction enables safe, consistent rewinding when ascending Unique mechanical over ride system for Emergency Services (Optional) Additional safety escape signage can be applied as directed Bespoke development and manufacture Coopers developed a unique smoke containment system that ensures our visitors are protected in the event of fire Mark Hosea, Director, York Minster Revealed 2 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 3

THE BENEFITS OF evacu8 SMOKE BARRIER OPTIONS The following options are available with the SmokeStop evacu8 system: Small compact headbox - easily concealed Trouble free operation design features Unobtrusive remote controls Mechanical override (optional) SmokeStop evacu8 uses a unique low opacity polymer coated glass fibre fabric for high performance impermeability, crease and abrasion resistance and translucency, which is A1 classified, the highest rating for reaction to fire classifications available in accordance with BS EN 13501-1+A1. SmokeStop evacu8 is CE marked and tested to BS EN 12101-1+A1 and has achieved a D 600 A classification to BS EN 13501-4+A1. MECHANICAL OVERRIDE - As an optional extra, the smoke barrier can be supplied with a manual override system designed to provide local, manual control of the smoke curtain s deployment and ascent. The feature allows maintenance teams to turn off the power to the smoke barrier to conduct planned and necessary servicing or maintenance. TRANSLUCENT FABRIC - Allows escapees to see the other side of the escape route therefore being aware of any possible danger and removing the risk of injury. SIGNAGE - The fabric panels of the curtain can be easily printed onto displaying any necessary images such as fire escape signs, messages or company logos, where agreed by an approved authority. ALARM SYSTEM - Can be stand alone with an independent smoke and/or heat detector or connected to a building s existing fire alarm system. BMS (Building Management System) - The system can easily be incorporated into any Building Management System. DEPLOYMENT OPTIONS SIZES Standard Deployment Multistage Deployment Standard Size Range Available (Metres) Widths up to Drops up to Maximum Size Unlimited 6.7m* 1 2 Full closure of alternate fabric panels creates clear escape routes Partial closure of all fabric panels provides initial smoke layer depth protection whilst allowing clear Width 3 4 Drop Full closure of remaining fabric panels provides total smoke protection whilst still allowing Full closure of remaining fabric panels provides total smoke protection whilst still allowing Signage for illustration purposes only *Coopers has a design solution for any size requirement. Specific heights may increase panel width and overlap, please contact our technical department for further information. 4 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 5

ACCESS CONTROL OPTIONS CONTROLS SPECIFICATION Access for maintenance is always required through the bottom of the headbox along the entire width of the SmokeStop evacu8 barrier. This is achieved by removing the bottom panels on both sides of the headbox as illustrated below. (Remember, regular service and maintenance is a legal mandatory requirement) 300mm Alarm PSU - ERU POWER SUPPLY 230V AC 50Hz dedicated supply via all pole isolator BATTERY BACK_UP 2 x 12V 7A/h lead acid batteries ALARM SIGNAL Normally closed volt-free contacts. Open on activation 200mm The maximum drop available from the headbox illustrated left is 4m. For a drop between 4m and 6.7m a 350mm x 250mm headbox is required. TEST FACILITY Zone Control Panel (ZCP) located on front of Power Supply Unit (PSU) DISPLAY Power ON, Alarm ACTIVE and Alarm OFF status LED s on ZCP POWER SUPPLY UNIT - Panel Size 400mm(w) x 500mm(h) x 210mm(d) 60mm COMMON APPLICATIONS Underground Rail Stations Airports Stadiums Museums Office Blocks Cinemas Shopping Centres Libraries Universities Schools Hospitals Restaurants PRODUCT SPECIFICATION The complete system is CE Marked in accordance with the Construction Products Regulation (305/2011), as required by the CE Marking Directive (93/68/EEC), when tested in accordance with BS EN 12101-1+A1:2005. System is classified as D 600 A in accordance with BS EN 13501-4:2007+A1:2009. The complete system is also classified to DA to BS ISO 21927-1:2008. EFP TM 2/600/T is a tried and tested smoke fabric. The base fabric is glass fibre with a specially formulated low opacity and fire retardant polymer coating to allow some visible light to pass through. The fabric is additionally tested to BS EN ISO 1716:2010 and is classified to A1 in accordance with BS EN 13501-1:2007+A1:2009. Fire propagation to BS 476 6:1989+A1:2009 and surface spread of flame to BS 476-7:1997 to achieve National Class 0 in accordance with A13(b) Approved Document B 2006 Edition Fire Safety to the Building Regulations 2000 England and Wales. DON T BE LIABLE Smoke Barriers are legally required to be CE Marked under the Construction Products Regulation. They must be fail safe in the event of total mains, wiring, short circuit and/ or system corruption. Coopers Fire, with their unique patented Total Gravity Fail-Safe (TGFS) system, are the only supplier with Independant Third Party Certification by a UKAS approved certification body, and CE Marked as fully compliant with BS EN 12101-1:2005+A1:2006. QUALITY ASSURANCE AND CERTIFICATION MEMBERSHIP CPD ACCREDITATIONS 6 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 7

For information, to get a quote or to book a CPD workshop Please call: +44 (0)2392 454 405 or E-mail: info@coopersfire.com WWW.COOPERSFIRE.COM Coopers Fire Ltd, Edward House, Penner Road, Havant, Hampshire, PO9 1QZ United Kingdom Phone: +44 (0)2392 454 405 Fax: +44 (0)2392 492 732 Email: info@coopersfire.com Web: www.coopersfire.com Coopers Fire Ltd has a policy of continuous product improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website for the latest information Coopers Fire Ltd. All content and products are copyright of Coopers Fire Ltd. Registered in England Number: 2010274. Multiple patents granted and pending. Series 2 v06 April 2018 8 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION