International Journal of Scientific & Engineering Research Volume 8, Issue 11, November-2017 ISSN Volatile Sampling Device Prototype II

Similar documents
Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

International Engineering Research Journal Performance assessment of multistage thermoelectric cooling module based refrigerator

CALIDUS tm the Modular micro Gas Chromatograph

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

LYOPHILIZATION- THE PROCESS AND INDUSTRIAL USE

HEAT PIPES

Unit THE NATURE OF HEAT

Aromatics and Oxygenates in Gasoline June2018

CHAPTER 1 INTRODUCTION

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Fabrication of Hot and Cold Water Dispenser

QAQC LABS ANALYTICAL DRYING

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Project Number: P15441

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Performance Assessment of Water Cooled Condenser Refrigeration System

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Eco-Friendly LPG Vaporization. by Efficient Use of Atmospheric Heat

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

COMPRESSOR LESS SOLAR REFRIGERATOR

300 series HPLC autosamplers

Evaporation System: Types and Design Aspects

Adsorption refrigeration system using waste heat

A REVIEW ON GREEN TECHNOLOGY IN HVAC

HISTORY OF VARIAN CAPILLARY INJECTORS

VAPOR SOLDERING DEVICE. RESEARCHER: ING. DO MAI LAM SUPERVISOR:Prof.Ing. IVAN UHLIR DrSc Ing. MARTIN NOVAK Ph.D.

KE2 EvaporatorEfficiency Theory of Operation

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Changes of phase usually involve a transfer of energy Evaporation

HPLC Column Ovens and Temperature Controllers

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Heat Transfer: Conduction. Heat Transfer: Conduction

No matter how adventurous a process engineer may

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

DESIGN AND FABRICATION OF THERMOELECTRIC COOLER CUM HEATER

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

GC Injectors. GC Injectors

Chapter 1 Introduction

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Designing evaporators and condensers for refrigerant mixtures with high temperature

Fourth Edition HEAT TRANSFER AND CHANGE OF PHASE

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Pocket Dilution Cooler

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Heat Dissipation in Control Panel using Heat Pipe

TMCI Padovan Evaporators

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

ASHRAE JOURNAL ON REHEAT

Boiler Basics. Design and operation

Electric radiator tests

Numerical study of heat pipe application in heat recovery systems

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Development and Testing of Hot Cold Tumbler Operating on Peltier Effect

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

I. C O N T E N T S T A N D A R D S

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

SAMPLE STUDY MATERIAL

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Developing UV LED Curing Processes for Converting Applications

Measurement of Drying Rates in a Domestic Scale Fluidized Bed Dryer

Optimizing Strategy for Boiler Drum Level Control

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Cryogenic cooling with CUMULUS LF.

Heat pump supplemental heating system for motor vehicles

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

(Refer Slide Time: 00:00:40 min)

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

A Novel Approach for the Thermal Management. of PC Power Supply

Technical Information

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

HVAC Water chiller selection and optimisation of operation

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Transcription:

International Journal of Scientific & Engineering Research Volume 8, Issue 11, November-217 ISSN 2229-5518 515 Volatile Sampling Device Prototype II Raquib Akolawala, Dr D. V. Bhoir Abstract For Gas Chromatographer there are currently many sampling devices that are used in conjunction with Gas Chromatographer to improve its detecting and sampling capability. Cryo-Focusing, Headspace sampling, Headspace Trap Sampling, Solid Phase Micro extraction, and many other techniques are used. There is also a technique known as Volatile sampling for which previous work for volatile sampling device prototype has been constructed. In overcoming the short comings of the previous device is being explored. Index Terms Gas Chromatographer, Volatile Sampling Device, Cartridge Heater, Compressor Refrigeration, Adsorption, Elution, Seperation. 1. GAS CHROMATOGRAPHY There are currently many diverse techniques that can be used for the separating solutes from mixtures. These are used in the analysis of constitutes of a mixture organic or inorganic in nature. Chromatograph is a chemical analytical instrument used for extraction of various constituents from a complex entity. The chromatograph uses a packed narrow column, in this column the complex entity which is to be extracted is entered from one end. Then due to adsorption and desorption phenomenon the various constituents of the entity travel at different velocities through the column. The constituents are then separated and differently collected. u point up to 2 C. Conventional methods for separating volatiles are biased towards one of the physical or chemical properties of the molecule and hence are not complete. So volatiles separated from the mother matrix will contain fewer molecules and even the most precise instruments can resolve only fewer molecules. On the other hand, a better sampling device utilising thermal desorption, kinetic desorption, solubility in steam, desorption by microwave, desorption by magnetic induction or laser can separate Figure 1 Gas Chromatographer Block Diagram In gas chromatography, the components of a sample are dissolved in a solvent and vaporized in order to separate the analytes by distributing the sample between two phases: a stationary phase and a mobile phase. The mobile phase is a chemically inert gas that serves to carry the molecules of the analyte through the heated column. To separate the compounds a solution sample that contains organic compounds of interest is injected into the sample port where it will be vaporized. The vaporized samples that are injected are then carried by an inert gas, which is often used by helium or nitrogen. This inert gas goes through a glass column packed with silica that is coated with a liquid. Materials that are less soluble in the liquid will increase the result faster than the material with greater solubility. The purpose of this module is to provide a better understanding on its separation and measurement techniques and its application. 2. VOLATILE SAMPLING DEVICE Volatiles in the current context are molecules with boiling 217 Figure 2 Volatile Sampling Device Block Diagram larger number of molecules and hence can enhance the efficiency of instruments like MS. A sampler using thermo-kinetic desorption was fabricated in house and comparative study was conducted against conventional techniques. A 25% increase in peaks was observed when analysed with GC. The possibility of thermal decomposition was ruled out by conducting GC- MS studies. The aim of the current study is to develop a highly precise sampling device with global standards and has wide applications in the field of aromatic, analytical, biological and medical fields. 2.1 Volatile Separating Device CFD Analysis This Report describes a new design approach that came from a volatile separation technology. The conventional methods, separated volatiles from materials from Organic matters are biased to any single physio-chemical properties of the volatile and are efficient to separate low boiling fractions only. The goal of this new design approach is to provide better heating and cooling modes, Equipment, maintaining of inert atmosphere in envelope, well stabilized desorptionadsorption process for volatiles from the provided organic

International Journal of Scientific & Engineering Research Volume 8, Issue 11, November-217 ISSN 2229-5518 516 matter. Volatile is a substance which can change state from a solid or liquid to vapour. Gas chromatography (GC) is the instrument used to study volatiles and it can analyse molecules whose boiling points are as high as 25OC or more. But it is necessary to make sure that Non-volatile material should not enter into the GC column. So there is a requirement of a safe sampling device for GC. Sampling device is separator unit, which will extract the molecules or volatiles from the given sample. The Prototype device for this is already manufactured, which is a POC (Proof of Concept). The goal of this report is to reduce the size of complete equipment, modular design. For the purpose of heating the envelope electrical heaters are used with sensor for establishment of feedback control system. Also for cooling the purpose electric cooling chip are used, which works on peltier effect. This report also analyses influence of the internal geometry design over flow path of nitrogen gas and turbulence created by pressurized nitrogen gas, with the help of CFD software. 2.2 Volatile Sampling Device Prototype-I and cooling have been experimented for optimum heating and cooling. A previous paper explores the same and a brief of the same has been mentioned below 2.3 Heating Curve Temperature(DegC) 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 Time (min) Figure 4 Condensor Heating Curve using 3 Heater The Initial heating was done with 2 number 125 Watts heater and natural cooling was observed in the same. It was noted after multiple iteration that the heating up to 2 degrees for the internal cavity where the material is to be processed takes up to 1 min on an average. This would not work with the flash heating concept. Subsequently Heating with Higher wattage heater and incrementing the number of heater were implemented without much success as SS 316 is bad 35 4 35 3 25 2 15 1 5 3 25 2 15 1 Figure 3 Volatile Sampling Device Prototype I Compared to the Previous development where Dry Ice and Acetone was used for achieving Sub-Zero Temperature range. In Prototype-I Peltier IC was employed. Due to Change in shape of Desoptor to accommodate the CFD analysis theory, Cylindrical Heater were not feasible. Instead Cartridge heaters were used. Critical analysis was heating and cooling of the Condensor which is supposed to reach sub-zero temperature range. Multiple variations of heating 5 2 4 6 8 Time (Min) Condensor Desoptor Figure 5 Heating and Natural Cooling Curve 217

International Journal of Scientific & Engineering Research Volume 8, Issue 11, November-217 ISSN 2229-5518 517 conductor of heat, therefore. Heating and cooling took longer period than expected. Though operating point of operation was around 2 degrees even after further increments by using 175Wattage heater the average time of heating remains at 7 to 8 minutes. Making heating operation incompatible with flash heating. Additionally, Natural cooling curve remains its course, hence affecting further cooling curve. 2.4 Cooling Curve 3 25 2.6 Limitations of Peltier during Cooling During Peltier operation, it was observed that the temperature difference between the hot and cold side of was a maximum of 4Degrees. Also, the Peltier needs to dissipate the amount of heat it is absorbing otherwise the Peltier tends to overheat on both the sides. For various commercially available Peltier, it was observed that the maximum temperature range that the hot side can go up to is 15 C. 7 6 5 2 15 1 4 3 2 1 5-1 Figure 6 Condensor Cooling Curve Figure 7 Condensor Cooling Curve The cooling was condenser was implanted in various So, cooling process could not begin until the condenser is fashion. Using water block the Peltier plate hot side was naturally air-cooled. Naturally air cooling drastically cooled to room temperature. This would enable us generate increases the time required for one cycle. Also when the a temperature difference of 2 to 3 degrees at the maximum Peltier is used only with a heat sink on the opposite side the the graph as shown explain the behaviour of condenser lowest temperature achieved is significantly different from temperature during cooling. After sometime as the water when Ice cooled water is supplied using water blocks. When heats up the effectiveness of Peltier cooling is lost and the the lowest temperature of -24 C was to be achieved Ice water same can be seen on the graph. Also roughly 3 min of was used for the purpose. This in turn makes the system effective cooling was achieved. bulk. Also each Peltier draws a power of 12W on 12V, the To further improve the cooling the water block were used Power supply requirement also increase drastically when with ice water creating a more effective but extremely bulky using 3 Peltier IC, in parallel. cooling solutions as the ice water would require continuous circulation. And the effective cooling time achieved was only 1 mins. After which the temperature stabilizes if the ice 3. FURTHER MODIFICATIONS water allowed to circulate the ice eventually melts creating lack of cooling for further iteration. Thus, generating variable results in case to case basis 45 9 135 18 225 27 315 36 45 45 495 54 585 63 2.5 Limitations of SS316L during Heating SS316L has a very poor thermal conductivity hence during heating and cooling process it takes up lots of time. Also during the same period if additional heat sink or any other cooling device is employed bringing the temperature down to room temperature takes a lot of time. Though the SS316L is compatible with any organic material but its inability for quick temperature turn around makes it unsuitable for volatile sampling device. 217 Figure 8 Anodised Aluminium Desoptor Condensor Considering the following limitations, it was further decided to use Anodized Aluminium and replace the Peltier IC with a cooling agent circulation technique. The reasoning being that Aluminium having a lower thermal resistance will offer

International Journal of Scientific & Engineering Research Volume 8, Issue 11, November-217 ISSN 2229-5518 518 quick turnaround need for volatile sampling device. The results of the same are discussed further. As for the cooling agent, it was decided that when a pre-cooled media was prepared and circulated through the system the temperature presented in the graph. It can be seen with that 2-cartridge 16 14 Figure 9 Compressor Refrigeration System drop would indeed been driven by the thermal capacity of the cooling media. In the case of use of Aluminium for Desoptor and Condensor it would be a considerable advantage to have a cooling media of higher thermal capacity i.e. using of media other than water. An oil based mixture being the most stable under higher temperature and still in liquid state at sub-zero temperature. heaters of 175W it consistently possible to achieve 15 C in under a minute. The control of the temperature is perfectly linear in nature. Any other temperature required above 4. VOLATILE SAMPLING DEVICE PROTOTYPE-II 15 C is achieved with the same curve, data of the same can be extrapolated from the graph mentioned below. This give Considering the modification, it was duly decided to employ a fair bit advantage in heating temperature control of a compressor based thermal refrigeration system for cooling. desoptor with regards to time taken to achieve a particular An oil bath was thus prepared which would be pre-cooled temperature. to -5 C for rapid turnaround of temperature. This cooling Condensor fabricated from Aluminium was heated using 2- media was circulated only through the Condensor and cartridge heaters of 175W. After multiple iteration and Desoptor cooling not being critical in nature was air-cooled taking the average reading of the same plotted below is the to conserve energy and reduce cost. The heating and cooling heating graph for Condensor. Like Desoptor, even curve of same have been plotted below. For Manufacturing Condensor has linear heating curve. Heating below and the Condensor and Desoptor Commercial Grade above the mentioned temperature, the time required can be Aluminium was used. Both the components were White directly extrapolated from the curve shown below. Anodized from inside as well as outside. 4.1 Heating Curve 16 14 12 1 8 6 4 2 1 3 5 7 9 1 15 21 24 28 34 4 47 Figure 11 Desoptor heating to 15 C After multiple iterations for heating of Desoptor fabricated from Aluminium, the following average reading are 12 1 8 6 4 2 8 16 22 26 3 34 38 44 5 58 66 8 15 Figure 1 Condensor Heating To 15 C 4.2 Cooling Curve Cooling of Desoptor being predominantly by natural air 217 18 16 14 12 1 8 6 4 2 24 51 7 96 125 158 197 24 32 375 479 576 77 Figure 12 Desoptor Cooling From 15 C

International Journal of Scientific & Engineering Research Volume 8, Issue 11, November-217 ISSN 2229-5518 519 convention. Cooling of the same was effected by using an instrument cooling fan. Also, cooling times of the Desoptor not being critical in nature. The average of multiple iteration has been plotted in the graph below. It can be seen that unlike SS316L Condensor the maximum cooling time for Aluminium Condensor from 15 C to room temperature is 1 minutes compared to 1 hours. This being a considerable advantage when reloading of samples were concerned. Condensor cooling was employed using oil based cooling media agent. The oil was pre-cooled to -5 C using compressor based refrigeration method. After the Condensor achieved a certain temperature the cooling media was pumped through the compressor under pressure, thus causing rapid fall in temperature. This fall in temperature can controlled with a delayed pumping operation. In the graph plotted below average values of multiple iterations where rapid pumping was always employed. It can be seen that the capacity selected is far excess in nature, as the temperature drops over 15 C in 3 odd seconds. This method being a very effective cooling method 16 14 12 1 8 6 4 2 the desired temperature range. The Compressor based refrigeration continuously consumes 1.5KW of energy but on the contrary generates results exceeding expectation. But the bulky nature of the compressor and its periphery components need to be worked on to improve it overall performance. 7. REFERENCES [1] Robert L. Grob and Eugene F Barry, 24, Modern Practice of Gas Chromatograph, John Wiley & Sons, inc. Publication [2] Daniel C. Harris, 27, Quantitative Chemical Analysis, W. H. Freeman and Company New York [3] Skoog, D. A., Holler, F. J,. Crouch, S. R, 27, Principles of Instrumental Analysis, Thomson Brooks/Cole, USA. [4] Andrew Tipler, 214, An Introduction To Headspace Sampling In Gas Chromatography Fundamentals And Theory, PerkinElmer, Inc. [5] Xinghua Guo and Ernst Lankmayr, 212, Hyphenated Techniques in Gas Chromatography, Advanced Gas Chromatography - Progress in Agricultural, Biomedical and Industrial Applications, Dr. Mustafa Ali Mohd (Ed.), Intech Europe [6] Dr B S Ajit Kumar and Dr Ajit Datar, 213 Designing and Construction of a Volatile Separating and Sampling Device Based on Thermo Kinetic Principle DST [7] Prasad Kawade, Dr B.S.Ajit Kumar, Kashyap Anandpara, D.S.S.Sudhakar, 215 Computer Aided Design And Analysis of Volatile Separating Device Procedia Science Direct [8] Swapnil V. Gondane, G. U. Tembhare, -REDESIGN AND ANALYSIS OF PRESAMPLER FOR GAS CHROMATOGRAPHER,ǁ IJIRT, Volume 4, Issue 2, July 216. [9] Anish U Burke Volatile Sampling Separation Device (Prototype-I) Volume 4 Issue 9, September 216 1 2 3 4 5 8 1 11 13 15 17 19 23 27 31 Figure 13 Condensor Cooling From 15 C 5. FUTURE SCOPE Cooling unit designed is very effective but bulky in nature. For effective operation of volatile sampling device, it would require a very power effective and size effective cooling methodology. In its current state a prototype of sampling can be generated and effective volatile sample can be verified. 6. CONCLUSION The incapability of SS316L heating and cooling have been compensated by employing Anodized Aluminium, which in turn also maintains the compatibility of a food grade material. Being light weight and cheaper than SS316L, Aluminium also a commercially feasible option. Peltier continuously consumed power supply of 36 watts along with Ice water bath required to keep it operational to achieve 217