ECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)

Similar documents
MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

AQUASNAP JUNIOR 30RHV

Dixell Installing and Operating Instructions release 7.0

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

Operating Functions Temperature Parameters

Air Cooled Scroll Chiller

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

User Guide ems25plus. Page 1. Normal operation. Product interface

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

MODULAR CHILLER. R410a R22

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

ACT2-CS Convenience Store Controller

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

PARAGON Commercial Refrigeration Controls

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Recalibrate the way you look at gas detection

Condensate water pumps

ERC2 Control Instructions

号 PRODUCTORS CATALOGUE. ChengDu SAND Electronic Co. Ltd

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

50A KP 70A KP 90A KP 120A KP 150A KP 210A

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

MODEL URS-1: FACTORY RETROFIT PROGRAM

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Inverter Swimming Pool Heat Pump

AIR COOLED PACKAGED CHILLER

EVAPORATIVE COOLER PUMPS

ETO 2 - Controller for ice and snow melting

CK C O M P R E S S O R

Oil-injected rotary screw compressors GA GA

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

VWR Laboratory Refrigerators and Freezers

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

MR3CCUHV Temperature/Defrost Control

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

ET10 Series Stand-alone LCD Fan Coil Thermostat

OPERATING INSTRUCTIONS

Refrigerated Compressed Air Dryer

Application Manual Loop Water Controller

CXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

settings and adjustments

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

Ductless Split Air Conditioner

SCA 620C AIR COOLED SCREW CHILLER

OPERATION, MAINTENANCE AND SAFETY INSTRUCTIONS

Q7800H Integrated Burner Control Subpanel

TECHNICAL SPECIFICATIONS

Versatile new products for multiple applications and specialty conditions. New Products Catalog

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Flash Temp Setting In the state of temp setting - Ready to refrigerate, in the state of compressor start delay protection

Manufacturer Update 2014 IGSHPA

The new generation of cold room solutions. CAMAlarm Alarm Alarm

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

TOSHIBA AIR CONDITIONING

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Table 1. Serie of Digital Room Thermostats.

DUNHAM-BUSH. Request for start-up and commissioning of Dunham-Bush chillers (Water Cooled or Air Cooled) and Condensing Units.

30RB /30RQ

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

GMM Güntner Motor Management

CENTRAL SPLIT UNIT UNIC

Upright Chromatography Refrigerators

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

DC INVERTER SERIES AIR TO WATER

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Daikin LXE10E Technical Information

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

Freeze Dry Systems and Accessories

GP SERIES Packaged Chillers

Mobile Type Air Conditioner

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Freeze Dry Systems and Accessories

ER52 - Evaporator Controller

DAIKIN Huizhou Factory Profile

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

2-wire Passive Intelligent Loop (LED) Display Meter

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

FCR 05, FCR 07. Power factor correction controller. User and service manual

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Transcription:

ECB-5070 General descriptions: This product has the function of current display and motor integrated, which can effectively avoid the various danger caused by the instability of current and voltage, to ensure safe operation of the device, and at the same time, users could intuitively view real-time current status. Dual sensor settings could control the dual-way loading of compressor and defrost. Compressor integrated function, which can effectively avoid the various danger caused by the instability of current and voltage, to ensure safe operation of the device and the safety of goods in the cold storage; integrated protector adopts digital processing technology, which could detect three-phase current and determine whether exists the failures of overload, phase failure, three phase current imbalance, ensuring the stable running of the device; dual temperature sensor could control temperature of compressor and the defrost, safer and more energy efficient; operation panel easy operation; independent function keys, easy operation without the guide of manual; dual display screen, which could intuitively view the current temperature and set temperature, easy to use for end users; crank heating function, which could effectively protect compressor and increase the service life of the compressor. It starts working when the compressor is off, shut down when the compressor starts; internal wiring in the box complies with electrical safety norms. All wirings are marked for easy maintenance. All wiring are performed pressure test or torque test; Box uses thicker metal plate material, paint treatment, moisture proof and shock proof, anti-corrosion, durable. Electric control box: W 300 * H 400 * D 150 (mm) Power supply: three-phase five-wire (or three-phase four-wire) 380VAC ± 10% 50Hz Dual temperature sensor for separately temperature control of compressor and defrost, more secure and energy-saving; Compressor integrated functions; The integrated protector can display three-phase current, and determine whether exists the failures of overload, phase failure, three phase current imbalance according to the current. Module Crank heating

ECB-5080F Split electrical control box Power box and panel separated, the effective signal transmission distance is up to 200 meters; The large panel temperature controller, beautiful, which could be freely installed in office, duty room, monitoring room, etc where is convenient for monitoring. Power box can be mounted directly on the unit, saving a lot of wire cost for customers; Operation panel is easy to operate; switch between Celsius and Fahrenheit; Independent function keys, easy operation, specially designed for cold storage market; The contractors could preset general parameters which could be directly invoked by users, reducing after sale maintenance costs; Have the engineering password function which could effectively avoid payment arrears for the contractors. Compressor integrated function; Unique box design: when take off the lid, only the control board, no interference of surrounding box shell, making the installation and wiring much more easier and bringing customers a whole new experience; W 280 * H 350 * D 140 (mm) Power supply: three-phase five-wire(or three-phase four-wire)380vac±10%/50hz Features: Dual temperature sensor for separately temperature control of compressor and defrost, more secure and energy-saving; Compressor integrated functions; Sensor failure and over-temperature alarm function Connection data line length: signal transmission distance not less than 200meters. Module Evaporator fan Crank heating

ECB-10 General descriptions: ECB-10 is a optimizing product especially designed for refrigerant units. Practical functions and complete. Easy-to operate, stable and reliable performance. ECB-10 is a universal Electric Control Box with rather high performance versus price ratio. User's parameter and manager's menu setting, common customers only need to set temperature parameter Single-point temperature adjustment, return difference for temperature controlling, easy-to-operate Temperature upper and lower limits control Refrigerating and Heating modes optional Comprehensive function of compressor Compressor starts/stops proportionally when sensor error Auto and manual control function Alarm functions when Sensor error and exceeding the temperature limits Product size: 300X400X150mm Power supply: Three-phase five-wire (or three-phase four-wire), 380 VAC±10%, 50Hz Temperature measuring and controlling range: -50 ~+99 Accuracy: ±1 Compressor start-up delay time: 0~9 minutes (Adjustable) Max. capacity of controlling the compressor and fan (KW): 11 Evaporator fan

ECB-30 General descriptions: ECB-30 is a optimizing product especially designed for refrigerant units. Double-sensor control, control three-load synchronously, proper and complete functions. Easy-to-operate, stable and reliable performance. ECB-30 is an Electric Control Box with multi-functions and rather high performance versus price ratio. Three-load control, can control compressor, fan, defrost independently. Double temperature measuring sensors to independently control the temperature of compressor and defroster, more safe and economic Thermal and electric heating defrost Comprehensive function for compressor Auto and manual control function Sensor error alarm and alarm when exceeding the temperature limits functions Compressor start-up delay adjustable Product size: 300X420X150mm Power supply: Three-phase five-wire (or three-phase four-wire), 380 VAC ±10%, 50Hz Temperature measuring and controlling range: -50 ~+50 Accuracy: ±1 Compressor start-up delay time: 0~9 minutes (Adjustable) Max. capacity of controlling the compressor (KW): 11 Max. capacity of controlling the fan(kw): 4 Max. capacity of controlling the defroster (KW):11 Module

ECB-3000 ECB-3000 is a optimizing product especially designed for mini-type cold storage. Easy parameters setting and operation reliable performance, complete functions. ABS fire-proof plastic material for security and good water-proof ability. Modifying parameters even when the machine is running. Auto and manual switch function, while in manual operation, it can control fan, compressor and defrost separately. compressor start-up delay. Fan start-up delay. Auto defrost and enforced defrost. Main control units are famous brand with high reliability. Product size: 250X190X139mm Power supply: Three-phase five-wire (or three-phase four-wire), 380VAC ±10%, 50Hz Temperature measuring and controlling range: -50 ~+50 Resolution: 0.1 Return difference: 1 ~+25 Defrost time: 0-255 minutes Defrost cycle: 0-120 hours Compressor start-up delay time: 0~50 minutes (Adjustable) Defrost thermal relay connected temperature: 50 Defrost relay connected temperature: 40 Max. capacity of controlling the compressor (KW): 5.5 Max. capacity of controlling the defroster (KW): 5.5 External power supply Unit pressure control If not used, please make it in short circuit. Defrost thermal If not used, please make it in short circuit.