KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

Similar documents
KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Packaged air conditioners vertical units

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

HT V2 HT Split

Cassette units Model Comfort Circle. - heating - cooling - ventilation

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

CATALOG WATER SOURCE HEAT PUMPS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

QZHW Fan Coil Unit. Key features. Specifications

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

technical data Fan coil unit FWB small duct unit

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

QFDK "ägir II" chilled water cassette

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

QTS SELECTION TECHNICAL BOOKLET

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Blower-YEFB-020-3R-1maxVel

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

Units for suspended ceilings

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

AIR-CONDITIONER SERVICE MANUAL

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

EHH SERIES DRAW THROUGH FAN COILS CFM

kw COOLING kw HEATING

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

SyScroll Air EVO NEW

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

BRISE. Super-power for heating, cooling and ventilation.

QZB "Standard" comfort fan coil

CASSETTE UNIT. Comfort Circle

Application guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E

HVS, Hydro Variable System Air cooled chiller

Units for suspended cei lings

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

NEW GREEN TECHNOLOGY

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SyScroll 40 to 75 Air NEW

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

TCHE-THHE TCEE

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Indirect Evaporative Air Conditioning

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

Brochure EX

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

21,8 222 kw COOLING 25,2 236 kw HEATING

Outside Air Requirements... SOLVED!

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Transcription:

KOG LN Low Noise Chilled Water Cassettes Models 30 & 45

Design Features Introduction Chilled Water units of the "Cassette" type offer comfortable air conditioning at a low cost of installation. They fit harmoniously into standard modules of a false ceiling thanks to their design and small space requirements. They are easy to be connected with water chillers producing chilled or hot water, and are used for : Cooling (Chilled Water) and Heating (Electric Heating). Heating (Hot Water). Simultaneous operation of Heating (Hot Water) and Electric Heating is strictly FORBIDDEN. Cassette air treatment unit It combines excellent technical qualities, reliability and easiness of installation. It includes : A flat (287 mm thick), insulated unit, flash mounted to be fitted into the false-ceiling, of a size compatible with standard modules of a false-ceiling (600 x 600 mm). Three-speed ventilation. Built-in electric heating to be connected on site. Condensate pump to lift at the top of the cassette. Draining should be provided for by gravity. Electric box of control and overload protection to be mounted on site. Combined discharge/air return grille with airfilter, discharge adjustable by hand on all 4 sides, air return at the center. Casing Panels and insulated sheet. Combined discharge/air return grille supplied separately for the Cassette. Possible hand operated adjustment of air distribution on all four sides. Possibility to close one or two faces of discharge. Air return at center with filter. Prepunched holes for connection with fresh air intake and connection with a stub duct to treat an adjacent room. In that case it becomes necessary to provide a decompres-sion in the adjacent room (grille...) to allow air return on the Cassette. Insulation Heat and sound insulation throughout the indoor air treatment unit. Ventilation Centrifugal turbine with direct drive. Motors mounted on rubbers and equipped with internal thermal safety devices. 3-speed (model 30 LN) or 4-speed (model 45 LN) motor for the air treatment unit. Filtration Cleanable air filter accessible after opening the discharge/intake combined grille. Filter type : Rapidly removable cassettes Media : Woven synthetics Fire resistance : M4 (PV LNE N 812 02 29 to 30/01/89) Efficiency : 55% (EUROVENT 4/5 - ASHRAE gravimetric 52-76 NF X 44-012) Maintenance : Washable (cold water with detergent not more than 25 washings) or dry dedusting. Electric heating The Cassettes are factory-equipped with electric heating to be connected on site. The electric heating equipped with heating resistances is heat protected against any abnormal raise of temperature by two thermostats : a thermostat with automatic reset, a thermostat with manual reset. Kits available Several kits are available : Condensate tray kit. Motorized 3-way valve kit with by-pass. Controls : TRM-VP (kit), TRM-FA (kit), TAE 20 (kit), TAE 20 + SEH (kit), Aqu@Simp and Aqu@Net. 2

Technical Data MODELS 30 LN - 2-pipe 45 LN - 2-pipe 45 LN - 4-pipe Nominal cooling capacity (1) - Nominal supply voltage 230V/50Hz W 7151 9298 9887 Nominal heating capacity (2) - Nominal supply voltage 230V/50Hz W 9716 11716 8980 AIR FLOW (AVERAGE VALUES) TREATED AIR High Speed m 3 /h 1300 1560 1560 Medium Speed m 3 /h 905 1080 1080 Low Speed m 3 /h 585 790 790 Super Low Speed m 3 /h - 540 540 Nominal water flow (cooling only) l/h 1232 1602 1703 Pressure loss on water (3) kpa 19.6 20.0 28.0 Contents l 2.7 4 4 Power supply V ~230 V - 50 Hz Voltage range V 207 / 253 V 30 LN - 2-pipe 45 LN - 2-pipe 45 LN - 4-pipe SOUND POWER LEVEL Lw Lp* global global NR Lw Lp* global global NR Lw Lp* global global NR High Speed dba 55.2 49.3 44 61.6 55.6 50 61.6 55.6 50 Medium Speed dba 46.4 40.6 36 53.7 48.1 42 53.7 48.1 42 Low Speed dba 37.5 31.9 29 46.3 40.7 35 46.3 40.7 35 Super Low Speed dba - - - 40.3 35 30 40.3 35 30 DIMENSIONS Casing (L x P x H) mm 1171 x 571 x 287 Grille (L x P x H) mm 1225 x 625 x 40 Net weight kg 49 55 55 PACKING Gross weight kg 51 58 58 Packed volume m 3 0.31 0.31 0.31 ACCESSORIES Electric heating nominal capacity W 2800 2800 - Motorized 3-way valve with by-pass l l l Condensate tray for valve l l l Note : (1) Nominal conditions : Air : 27 C/19 C wet bulb (nominal HS airflow) - Chilled water : 7 C/12 C. (2) Nominal conditions : Air : 20 C (nominal HS airflow) - Hot water : 50 C (nominal waterflow in chilled water mode). (3) Pressure loss by corresponding nominal flow. (*) The sound pressure levels Lp are based on (NR) characteristics of a room having volume of 100 m 3 with reverberation of 0.5 seconds. These characteristics are for information only and are subject to change without advance. 3

AC Fan Motor Electrical Data Models Fan speed Absorbed current (A) 30 LN 45 LN - 2-pipe 45 LN - 4-pipe Absorbed power (W) Absorbed current (A) Absorbed power (W) Absorbed current (A) Absorbed power (W) SLS - - 0.17 39 0.18 39 LS 0.17 38 0.25 58 0.30 63 MS 0.29 66 0.39 90 0.40 91 HS 0.45 100 0.69 136 0.70 140 Condensate Pump PUMP DATA Nominal voltage 1 ~ 230 V - 50 Hz Power input W 16 Current input A 0.12 Waterflow max. l/h 240 Max. manometric head mwg 0.5 Electric Heating The electric heating of the cassettes is composed of heating resistances placed inside the tubes of the heat exchanger. These resistances are heat protected against any abnormal temperature rise by two thermostats equipped with a "positive safety" device (mechanical or thermic destruction of the capillary switches off the heating permanently) : - a thermostat with automatic reset, Electric heating capacity Power supply : 1 ~ 230 V - 50 Hz or 3 N ~ 400 V - 50 Hz Standard models 30 LN 45 LN Capacity (W) 2800 2800 - a thermostat with manual reset. 4

Thermal Performance 2-pipe system Water in/out 7 C/12 C 27 C/47% 50 C/Qv 20 C Models 30 LN 45 LN Air flow (m 3 /h) Air flow (m 3 /h) LS MS HS SLS LS MS HS Entering air temperature / HR 585 905 1300 540 790 1080 1560 Total capacity W 4109 5740 7151 3858 5414 7039 9298 Sensible capacity W 3128 4394 5500 3041 4329 5728 7650 Water flow Qv l/h 708 989 1232 664 933 1212 1602 Water pressure drop kpa 7.5 13.5 19.6 4.5 8.0 12.5 20.0 Heating capacity W 5217 7486 9716 4832 6791 8842 11716 Water pressure drop kpa 7.5 13.5 19.6 4.5 8.0 12.5 20.0 4-pipe system Water in/out 7 C/12 C 27 C/47% 70 C/60 C 20 C Models 30 LN 45 LN Air flow (m 3 /h) Air flow (m 3 /h) LS MS HS SLS LS MS HS Entering air temperature / HR - - - 540 790 1080 1560 Total capacity W - - - 4255 5716 7925 9887 Sensible capacity W - - - 3254 4324 6185 7655 Water flow Qv l/h - - - 733 985 1365 1703 Water pressure drop kpa - - - 6.0 10.5 18.5 28 Heating capacity W - - - 4756 6586 7506 8980 Water pressure drop l/h - - - 417 577 658 788 Perte de charge sur l'eau kpa - - - 3.0 5.0 6.0 8.0 5

Pressure Drops Pwo Pressure drop 50 40 30 30 LN 45 LN - 4-pipe 45 LN - 2-pipe 20 10 Water flow 0 0 1 2 3 m 3 /h Pwo : Pressure drops of pure water. Pw : Pressure drops of brine water. Pw : K x Pwo. K : Glycol coefficient % Glycol Twm ( C) 10 20 30 40 50 3 1.135 1.234 1.385 1.53 1.85 5 1.13 1.23 1.38 1.51 1.77 10 1.12 1.22 1.37 1.47 1.66 15 1.11 1.19 1.36 1.46 1.64 20 1.1 1.18 1.35 1.44 1.59 25 1.09 1.17 1.33 1.43 1.57 30 1.08 1.16 1.31 1.42 1.56 35 1.07 1.15 1.29 1.41 1.54 40 1.06 1.14 1.28 1.4 1.52 45 1.05 1.13 1.25 1.37 1.49 50 1.04 1.12 1.22 1.34 1.47 55 0.99 1.1 1.2 1.31 1.44 60 0.94 1.09 1.19 1.28 1.42 Twm : Average temperature of the mixture. % Glycol Tse ( C) 10 20 30 40 50-25 yes -20 yes yes -15 yes yes -10 yes yes yes -5 yes yes yes yes 0 yes yes yes yes yes 5 yes yes yes yes yes Tse : Outdoor dry temperature. 6

Field of Operation Using chilled water Thi 13 Indoor temperature C Tsi 17 Cooling water C Twe 3 MINIMUM TEMPERATURE Thi 22 Indoor temperature C Tsi 32 Cooling water C Tse 18 MAXIMUM TEMPERATURE Using hot water (electric heating forbidden) Maximum indoor temperature C Thi 22 Tsi 32 Maximum entering water temperature C Twe 60 Characteristics Models 30 45 Contents l 2.7 4 Max. pressure of operation bar 15 15 Testing pressure bar 24 24 Couplings - 2-pipe Couplings - 4-pipe Thi Tsi Tse Twe : Indoor wet bulb. : Indoor dry bulb. : Outdoor dry bulb. : Entering water temperature. inch 1" gas male 1" gas male mm 26-34 male 26-34 male inch - 1" gas male (Cooling) 1/2" gas male (Heating) mm - 26-34 male (Cooling) 15-21 male (Heating) 7

Fresh Air Intake Fresh air flow should not exceed 12% of nominal air flow (See table hereunder). NOTE : An anti-frost thermostat preset at +5 C, installed on site on fresh air intake is mandatory for winter application. A filter, fan and insulated air duct (not supplied) are to be installed on site. Treated air discharge in an adjacent room In case of discharge towards an adjacent room, provide for decompression toward the air return of the treatment unit. Models 30 LN 45 LN Nominal air flow (HS) m 3 /h 1530 1630 Maximal fresh air flow m 3 /h 86 90 dapa 3 Available static pressure Available static pressure 2 1 0 0 dapa 3 2 1 0 0 45 LN 30 LN 100 200 3 00 400 5 00 600 7 00 45 LN 30 LN 100 200 3 00 400 5 00 600 7 00 m 3 /h Air flow m 3 /h Air flow Discharge duct 1 closed air louver Discharge duct 2 closed air louvers 8

Dimensions 2-pipe units DESCRIPTION 8 Water inlet connection (G1") 9 Water outlet connection (G1") 4-pipe units DESCRIPTION 1 False ceiling 8 Hot water outlet connection (G1/2") 2 T-shaped rod (false ceiling) 8a Hot water inlet connection (G1/2") 3 Heat exchanger 9 Chilled water outlet connection (G1") 4 Fan 9a Chilled water inlet connection (G1") 5 Suction grille 10 Port to distribute air through a duct into a neighbouring room (pre-punched) 6 Electric box (removable) 11 Port to suction fresh air (pre-punched) 7 Draining of condensates (Ø1/2") 9

3-Way Valve with By-pass The kit three-way valve with by-pass allows to control "all or nothing" of a cassette when operating chilled water mode or hot water mode. This kit includes a three-way valve with by-pass controlled by an electric servomotor. Motorized 3-way valve with by-pass Electric servomotor Valve body Condensate tray for 3-way valve Motorized 3-way valve with by-pass Electric box WATER OUTLET WATER INLET Condensate tray DIAMETER OF CONNECTION Models 30 LN 45 LN Water inlet G 3/4" Male 20-27 Water outlet G 3/4" Male 20-27 10

Notes 11

Systemair Airwell SAS route de Verneuil, 27570 Tillières-sur- Avre Tél. 02 32 60 61 00 Fax 02 32 32 55 13 www.systemair.fr Systemair EDM KOG2-S-1GB/09.14 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. september 2014