Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Similar documents
Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FE4A, FE5A Infinityr Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FH4A Fan Unit. Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

FCM4X. Product Specifications

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

FXM4X. Product Specifications FAN COILS FXM4X

WAHL A Product Specifications

FEM4X. Product Specifications FAN COILS /14/15

REM4P, REM4X. Product Specifications

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

Dimensions H x W x D in. (mm)

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Installation Instructions

Table of Contents. Page 2

Installation Instructions

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

PAJ3. Product Specifications

Installation Instructions

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Installation Instructions

PAR5. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

WJH4 Product Specifications

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

Model 655A Sizes

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

R4H4. Product Specifications

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

FUSE COVER CLIP LATCH (OMITTED ON 18-K3N)

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Installation Instructions

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Ruud Standard Efficiency Air Handler

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

CWA4 Chilled & Hot Water Fan Coil

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Ruud Standard Efficiency Air Handler

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Transcription:

Base eries Fan Coil izes 024, 036, 048 and 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The direct expansion fan coils are designed to cover a wide range of air handling requirements. They are compact and ready to fit where needed in the basement, crawlspace, attic, utility room, or closet. The unique cabinet design of these fan coils meet new stringent regulations for cabinet air leakage a requirement of 2% cabinet leakage rate when tested at 1.0 inches of static pressure. All units come with solid state fan controls, 1 -inch thick insulation with R value of 4.2, super -quiet multispeed motors, and fully wettable coils. Units can accommodate field -installed heaters from 3 to 30 kw.

TANDARD FEATURE Grooved copper tubing Lanced sine-wave aluminum fin Fully -wettable coil High -impact thermoplastic condensate pan Primary and secondary drain connections with brass inserts Multipoise design for maximum versatility Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2% cabinet leakage rate when tested at 1.0 inches of static pressure. Field -installed heater packages from 3-30 kw (fused, circuit breaker, or non -fused) Control board with built -in, replaceable 5 -amp blade -type auto fuse Cooling controls Time -delay relay (TDR) Pre -painted galvanized steel cabinet High -density, super-thick R -4.2 insulation Newly -improved filter rack area filter door insulation added for an improved air seal weat connections Inspection plate for cleaning A -coil design HUD approved for manufactured housing 40 -VA, 208/230v transformer 024, 036, 048 and 060 sizes AccuRaterr metering device 3 -speed motor on all sizes Factory -supplied, cleanable, permanent framed filter Factory -supplied power plug Multiple electric entry ADDITIONAL FEATURE 2

NOMENCLATURE CHART CARRIER FAN COIL 1 2 3 4 5 6 7, 8, 9 10, 11, 12 13 14 15 16 F B 4 B N L 024 000 A A A A Product eries Type Position Major eries Electrical Cabinet/Insulation Nominal Capacity (Btu) Heating ize (kw) Variations F=FanCoil B=tandard, R --- 22 4 = Multipoise B N = 208/230v 1ph---60hz L=LatinAmerican Export 024 = 24,000 036 = 36,000 048 = 48,000 060 = 60,000 000 --- No Heat IO 9001:2000 REGITERED 3

DIMENION A06165 UNIT IZE COIL TYPE A B C D E J IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM 024 lope 42---11/16 1084.3 14---5/16 363.5 12---7/16 316.0 12---5/16 312.7 10---7/16 265.1 12.0 304.8 036 lope 49---5/8 1260.5 17---5/8 447.5 15---3/4 400.1 15---5/8 396.9 15---3/8 390.5 17.0 431.8 048 A 49---5/8 1260.5 21---1/8 536.5 19---1/4 489.0 19---1/8 485.8 15---11/16 398.3 060 A 53---7/16 1357.3 21---1/8 536.5 19---1/4 489.0 19---1/8 485.8 19---1/2 495.3 4

DIMENION (CONT.) A05356 UNIT IZE COIL TYPE F G IN. MM IN. MM 024 lope 18---1/8 460.4 18---5/8 473.1 036 lope 23---1/8 587.4 23---5/8 600.0 048 A 23---7/16 593.3 23---1/8 587.4 060 A 27---1/4 692.2 26---15/16 684.2 5

PECIFICATION MODEL 024 036 048 060 hipping Weight (Lb) 112 127 157 175 Refrigerant Metering Device Bypass AccuRaterR Piston ize 63 76 88 96 COIL Rows and Fins Per In. 3 and 14.5 Face Area (q Ft) 2.23 2.97 4.45 5.93 Configuration lope lope A A FAN AirDischargeCFM(Nominal)MotorHp(PC) 850 1/4 1300 1/3 1700 3/4 2000 3/4 FILTER IZE 21---1/2 x 13 21---1/2 x 16---3/8 21---1/2 x 19---7/8 FILTER CABINET CONFIGURATION OPTION 1 --- piece 1 --- piece 1 --- piece 1 --- piece AIRFLOW PERFORMANCE (CFM) PERFORMANCE DATA IZE 024 036 048 060 BLOWER MOTOR PEED TOTALEXTERNALTATICPREURE(IN.WC) 0.10 0.20 0.30 0.40 0.50 0.60 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V High 945 975 900 930 840 870 780 805 695 725 560 595 Medium 835 900 795 855 745 800 690 740 610 650 470 510 Low 605 695 575 665 530 625 485 580 425 510 340 395 High 1485 1550 1425 1490 1365 1420 1300 1350 1230 1275 1150 1190 Medium 1235 1380 1200 1325 1160 1265 1110 1210 1055 1140 985 1070 Low 1035 1185 1010 1150 980 1115 940 1070 890 1010 825 935 High 1880 1935 1785 1830 1700 1735 1615 1645 1520 1555 1430 1460 Medium 1740 1840 1660 1750 1585 1660 1510 1575 1435 1485 1350 1390 Low 1425 1605 1395 1555 1360 1495 1315 1430 1255 1360 1170 1270 High 2145 2245 2085 2185 2030 2115 1965 2045 1905 1975 1830 1895 Medium 2025 2175 1970 2110 1915 2050 1860 1980 1805 1905 1740 1830 Low 1680 1895 1655 1855 1625 1810 1595 1765 1555 1705 1500 1645 NOTE: 1. Airflow based upon dry coil at 230v with factory approved filter and electric heater (2 element heater, sizes 024 and 036; 3 element heater, sizes 048 and 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.4 in. wc. Horizontal applications of 048-070 sizes must have supply static greater than 0.20 in.wc. Airflow outside max ARI airflow of 450 cfm/ton on 024-154 sizes. Airflow above 400 cfm/ton on 060-070 sizes. Airflows in this region could result in condensate blowing off coil or splashing out of drain pan. MINIMUM CFM AND MOTOR PEED ELECTION IZE HEATER KW 3 5 8 9 10 15 18 20 24 30 024 700 700 700 700 775* 036 1050 970 970 970 920 1040 048 1400 1400 1400 1400 1400 1400 1400 1400 060 1750 1750 1750 1750 1750 1750 1750 1750 *Indicates medium speed (blue). All other motor speeds at low tap. FACTORY -INTALLED ACCEORY FILTER TATIC PREURE DROP (IN. WC) UNIT IZE CFM 400 600 800 1000 1200 1400 1600 1800 2000 024 0.044 0.075 0.110 036 0.072 0.100 0.130 048 0.092 0.120 0.152 060 0.120 0.152 0.187 6

ELECTRIC HEATER TATIC PREURE DROP (IN. WC) 024 --- 036 048 --- 060 HEATER ELEMENT KW EXTERNAL TATIC PREURE CORRECTION HEATER ELEMENT KW EXTERNAL TATIC PREURE CORRECTION 0 0 +.02 0 0 +.04 1 3, 5 +.01 2 8, 10 +.02 2 8, 10 0 3 9, 15 0 3 9, 15.02 4 20.02 4 20.04 6 18, 24, 30.10 The airflow performance data was developed using fan coils with 10---kW electric heaters (2 elements) in the 024 and 036 size units and 15---kW heaters (3 elements) in the 048 and 060 size units. For fan coils with heaters of a different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PREURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY -TO -WET COIL) IZE CFM 500 600 700 800 900 1000 1100 1200 1300 1350 1400 1500 1600 1700 1800 1900 2000 024 0.035 0.051 0.066 0.080 0.091 036 0.073 0.081 0.091 0.098 0.102 048 0.066 0.073 0.080 0.086 0.091 060 0.051 0.057 0.063 0.069 0.073 NOTE: ubtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. GRO COOLING CAPACITIE (MBH) UNIT 024 036 048 060 EVAPORATOR AIR CFM AND BF 600 0.05 700 0.06 875 0.08 800 0.05 900 0.06 1100 0.07 1300 0.09 1200 0.05 1400 0.06 1600 0.07 1750 0.08 1300 0.03 1600 0.05 1750 0.05 2000 0.06 COIL REFRIGERANT TEMPERATURE ( F)* 35 40 45 50 55 Evaporator Air Entering Wet---Bulb Temp ( F) 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 39 33 27 36 29 23 31 24 18 27 19 15 21 14 12 19 20 22 17 19 20 15 16 17 13 14 15 11 12 12 42 35 29 38 31 25 34 27 20 29 21 17 23 16 14 20 22 24 18 20 22 17 18 20 15 16 17 13 14 14 47 39 32 42 35 28 38 30 23 32 24 20 26 18 17 22 25 28 21 23 26 19 21 23 17 19 20 15 16 17 53 43 35 48 38 29 41 31 23 34 25 18 27 18 15 25 27 28 23 24 25 20 21 22 17 19 18 15 16 15 58 47 38 52 41 32 45 34 26 37 27 20 29 19 16 27 30 31 25 27 28 22 24 25 19 21 20 16 17 16 65 54 43 58 47 36 51 39 29 43 31 24 33 22 20 31 34 36 28 31 33 25 28 29 22 24 24 19 20 19 71 59 48 64 51 41 56 43 33 47 35 27 37 25 22 34 38 41 31 35 37 28 31 32 25 28 27 21 23 22 83 69 56 75 61 48 66 52 39 56 41 32 45 30 26 39 43 46 36 39 42 32 35 37 28 31 32 24 26 26 90 75 61 82 66 53 72 57 43 61 45 36 49 33 30 42 47 51 39 43 47 35 39 42 31 34 36 27 29 30 95 79 65 87 71 56 77 60 47 66 48 40 52 36 33 45 51 55 42 47 51 38 42 46 34 38 40 29 32 33 99 83 68 90 74 59 80 63 50 69 51 42 55 37 35 47 53 59 44 49 54 40 45 49 36 40 42 31 34 35 91 74 60 81 65 51 72 55 41 60 44 31 48 31 26 43 46 48 39 41 43 35 37 38 30 32 31 25 27 26 104 85 69 94 76 59 83 64 47 70 51 38 55 37 31 49 53 57 45 49 51 40 44 45 35 38 38 30 32 31 109 91 73 99 80 63 87 68 51 74 54 41 58 39 33 52 57 61 47 52 55 43 47 49 38 41 41 32 35 33 117 97 80 106 86 68 94 74 56 80 59 45 64 43 38 56 62 67 51 57 61 46 51 54 41 45 45 35 39 38 CFM - Cubic Ft. per Minute EWB - Entering Wet Bulb (_F) LWB - Leaving Wet Bulb (_F) TC - Gross Cooling Capacity 1000 Btuh HC - Gross ensible Capacity 1000 Btuh BF - Bypass Factor MBH - 1000 Btuh 7

NOTE: 1. Contact manufacturer for cooling capacities at conditions other thanshownintable. 2. Formulas: Leaving db = entering db ---sensible heat cap. 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (h lwb ) h lwb =h ewb ---total capacity (Btuh) 4.5 x CFM where h ewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. HC is based on 80_F db temperature of air entering coil. Below 80_F db, subtract (Correction Factor x CFM) from HC. Above 80_F db, add (Correction Factor x CFM) to HC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. BYPA FACTOR HC CORRECTION FACTOR ENTERING AIR DRY-- BULB TEMPERATURE (_F) 79 78 77 76 75 Under 75 81 82 83 84 85 Over 85 Correction Factor 0.10.098 1.96 2.94 3.92 4.91 Use 0.20 0.87 1.74 2.62 3.49 4.36 formula shown 0.30 0.76 1.53 2.29 3.05 3.82 below Interpolation is permissible. Correction Factor = 1.09 x (1 --- BF) x (db --- 80) ACCEORY ELECTRIC HEATER HEATER PART NO. KW @ VOLT/ TAGE (KW INTERNAL CIRCUIT FAN COIL IZE HEATING CAP.** 240V PH OPERATING) PROTECTION UED WITH @ 230V KFCEH0401N03 3 230/1 3 None 018 024 9,400 KFCEH0501N05 5 230/1 5 None 018 060 15,700 KFCEH0801N08 8 230/1 8 None 018 070 25,100 KFCEH0901N10 10 230/1 10 None 018 070 31,400 KFCEH1601315 15 230/3 5, 15 None 036 070 47,100 KFCEH2001318 18 230/3 6, 12, 18 None 042 070 56,500 KFCEH2401C05 5 230/1 5 Circuit Breaker 018 060 15,700 KFCEH2501C08 8 230/1 8 Circuit Breaker 018 070 25,100 KFCEH2601C10 10 230/1 10 Circuit Breaker 018 070 31,400 KFCEH2901N09 9 230/1 3, 9 None 036 070 28,200 KFCEH3001F15 15 230/1 5, 15 Fuse 024 070 47,100 KFCEH3101C15 15 230/1 5, 15 Circuit Breaker 024 070 47,100 KFCEH3201F20 20 230/1 5, 20 Fuse 030 070 62,800 KFCEH3301C20 20 230/1 5, 20 Circuit Breaker 030 070 62,800 KFCEH3401F24 24 230/3* 8, 16, 24 Fuse 048, 060, 070 78,300 KFCEH3501F30 30 230/3* 10, 20, 30 Fuse 048, 060, 070 94,100 * Field convertible to 1 phase. { Fieldconvertibleto3phase. } ingle point wiring kit required for these heaters in Canada. ** Blower motor heat not included. ETIMATED OUND POWER LEVEL (dba) CONDITION OCTAVE BAND CENTER FREQUENCY* IZE Ext tatic CFM Pressure 63 125 250 500 1000 2000 4000 024 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 036 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 048 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0 060 2000 0.25 70.0 66.0 62.0 59.0 57.0 55.0 51.0 * Estimated sound power levels have been derived using the method described in the 1987 AHRAE HVAC ystems & Applications Handbook, Chapter 52, p. 52.7. FAN COIL ELECTRICAL DATA (UNIT WITHOUT ELECTRICAL HEAT) BRANCH CIRCUIT IZE VOLT (1 PHAE) FLA MIN CKT AMP Min Wire ize Fuse Amps Awg* 024 208/230 1.8 2.3 14 15 036 208/230 2.7 3.4 14 15 048 208/230 4.3 5.4 14 15 060 208/230 5.4 6.8 14 15 *Usecopperwireonly.Use75_C only in this application. When using non---metallic (NM) sheathed cable, wire size required should be based on that of 60_C conductors, instead of wire sizes shown in table above per NEC Article 336---26. FLA --- Full Load Amps NOTE: If branch circuit wire length exceeds 100 ft, consult NEC 215---2 to determine maximum wire length. Use 2% voltage drop. 8

ACCEORY ELECTRIC HEATER ELECTRICAL DATA HEATER PART NO. KW P H A E INTERNAL CIRCUIT PROTEC- TION ingle Circuit HEATER AMP 208/230V Dual Circuit ingle Circuit Min Ampacity 208/230V** Dual Circuit 240v 208v L1,L2 L3,L4 L1,L2 L3,L4 Min Wire ize (AWG) 208/230V ingle Circuit Dual Circuit L1,L L3,L 2 4 BRANCH CIRCUIT ingle Circuit Min Gnd Wire ize 208/230V Dual Circuit L1,L L3,L 2 4 Max Fuse/Ckt Bkr Amps 208/230V ingle Circuit Dual Circuit ingle Circuit Max Wire Length 208/230V (Ft) Dual Circuit L1,L2 L3,L4 L1,L2 L3,L4 KFCEH0401N03 3 2.3 1 None 10.9/12.0 15.9/17.3 12/12 12/12 20/20 67/68 KFCEH0501N05 1 5 3.8 1 None 18.1/20.0 26.0/28.4 10/10 10/10 30/30 66/66 KFCEH0501N05 2 5 3.8 1 None 18.1/20.0 31.2/33.5 8/8 10/10 35/35 85/88 KFCEH2401C05 1 5 3.8 1 Ckt Bkr 18.1/20.0 26.0/28.4 10/10 10/10 30/30 66/66 KFCEH2401C05 2 5 3.8 1 Ckt Bkr 18.1/20.0 31.2/33.5 8/8 10/10 35/35 85/88 KFCEH0801N08 8 6.0 1 None 28.9/32.0 44.7/48.5 8/8 10/10 45/50 59/60 KFCEH2501C08 8 6.0 1 Ckt Bkr 28.9/32.0 44.7/48.5 8/8 10/10 45/50 59/60 KFCEH2901N09* 9 6.8 1 None 32.8/36.0 49.5/53.5 8/6 10/10 50/60 54/87 KFCEH2901N09 * 9 6.8 3 None 18.8/20.8 32.0/34.5 8/8 10/10 35/35 83/85 KFCEH0901N10 10 7.5 1 None 36.2/40.0 53.8/58.5 6/6 10/10 60/60 78/80 KFCEH2601C10 10 7.5 1 Ckt Bkr 36.2/40.0 53.8/58.5 6/6 10/10 60/60 78/80 KFCEH3001F15* 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFCEH3101C15* 15 11.3 1 Ckt Bkr 36.2/40.0 18.1/20.0 53.8/58.5 22.7/25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76 KFCEH1601315 15 11.3 3 None 31.3/34.6 47.7/51.8 8/6 10/10 50/60 56/90 KFCEH2001318 18 13.5 3 None 37.6/41.5 55.5/60.4 6/6 10/8 60/70 76/77 KFCEH3201F20* 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFCEH3301C20* 20 15.0 1 Ckt Bkr 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59 KFCEH3401F24 * KFCEH3501F30 * 24 18.0 3 Fuse 50.1/55.4 71.2/77.8 4/4 8/8 80/80 94/95 24 18.0 1 Fuse 86.7/95.5 116.9/127.9 1/1 6/6 125/150 115/116 30 22.5 3 Fuse 62.6/69.2 86.8/95.0 3/3 8/8 90/100 97/98 30 22.5 1 Fuse 109.0/120.0 144.8/158.5 0/00 6/6 150/175 117/150 FIELD MULTIPOINT WIRING OF 24 -AND 30 -KW INGLE PHAE HEATER PART NO. HEATER AMP MIN AMPACITY MIN WIRE IZE (AWG) KW MIN GND MAX FUE/CKT BKR AMP MAX WIRE LENGTH PHAE 208/230V 208/230V** 208/230V WIRE IZE 208/230V 208/230V (FT) 240V 208V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 208/230V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 KFCEH3401F24 * 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFCEH3501F30 * 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 * Heaters are Intelligent Heat capable when used with the FE, FK and FV fan coils and corporate 2---speed programmable thermostat (TTATCCP201---B), Thermidistatt Control (TTATCCPRH01---B), or Comfort Zone II. { Field convertible to 1 phase, single or multiple supply circuit. } Field convertible to 3 phase. ** Includes blower motor amps of largest fan coil used with heater. {{ Copper wire must be used. If other than uncoated (non---plated), 75_C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANI/NFPA 70). }} Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. NOTE: 1. For fan coil sizes 018---036. 2. For fan coil sizes 042---060 and all FK4D, FV4B sizes. 3. ingle circuit application of F15 and F20 heaters requires single---point wiring kit accessory. 9

ELECTRIC HEATER INTERNAL PROTECTION* HEATER KW PHAE FUE QTY/IZE CKT BKR QTY/IZE{ 3 1 5 1 1/60 8 1 1/60 10 1 1/60 15 1 2/30 2/60 2/60 20 1 4/60 2/60 24 1/3 6/60 30 1/3 6/60 9 1/3 15 3 18 3 * 5 ---, 8 ---, 10 ---kw factory ---installed heat has no internal protection. 15 ---kw factory ---installed heat is internally protected with fuses. { Circuit breakers are 2 pole. 10

ACCEORIE ITEM ACCEORY PART NO.* FAN COIL IZE UED WITH 1. Disconnect Kit KFADK0201DC Cooling controls and heaters 3--- through 10--- kw KFACB0101CFB 024 2. Downflow Base Kit KFACB0201CFB 036 KFACB0301CFB 048, 060 3. Downflow Conversion Kit KFADC0201LP lope Coil Units 024, 036 KFADC0401ACL A--- Coil Units 048, 060 4. ingle--- Point Wiring Kit KFAP0101PK Only with 15 --- and 20 --- kw Fused Heaters KFAFK0212ML 024 5. Filter Kit (12 Pack) KFAFK0312MED 036 KFAFK0412LRG 048, 060 6. PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 7. Air Cleaner 240--- volt Conversion Kit KEAVC0201240 All 8. Downflow/Horizontal Conversion Gasket Kit KFAHD0101LP All 9. Horizontal Water Management Kit (25 pack) KFAHC0125AAA All * Factory authorized and listed, field---installed. Accessory Kits Description uggested and Required Use. 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. UGGETED UE: Units for 3 - through 10 -kw electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1 -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap -free seal with the floor. REQUIRED UE: This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. eparate kits are available for slope coils and A -coils. REQUIRED UE: This kit must be used whenever fan coils are used in downflow applications. 4. ingle Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy -gauge, high -voltage wires into the fan coil rather than 4 light-gauge, high -voltage wires. UGGETED UE: Fan coils with 15 - and 20 -kw fused heaters only. 5. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. UGGETED UE: To replace filters in fan coils. REQUIRED UE: All units unless a filter grille is used. 6. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. UGGETED UE: All fan coils. 7. Air Cleaner 240 -volt Conversion Kit The AIRA electronic air cleaner comes ready for 115 -v operation. REQUIRED UE: This kit is required when running 240 -volt circuit to air cleaner. 8. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED UE: Fan coils in either downflow or horizontal applications. 9. Horizontal Applications - Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. UGGETED UE: All fan coils. 11

Copyright 2006 Carrier Corp. 7310 W. Morris t. Indianapolis, IN 46231 Printed in U..A. Edition Date: 05/06 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: --- L1PD Replaces: New 12