ECL Comfort 300 / V a.c. and 24 V a.c.

Similar documents
ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

One Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition

ECL Comfort 110, application 116

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Installation Guide. ECL Comfort 310, application A Table of Contents

Weather compensated flow temperature control of heating and boiler systems

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

ECL Comfort 110, application 130

120+ Get your job done swiftly Easy selection of your application is the key. applications.

ECL Comfort 210/296/310, application A247/A347

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

OJ Waterline control system

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Temperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING. Manual

Alarm description DECS Contents

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

Corrigo E. Second generation which contains all applications and languages

The full range of Evaporator Controls from ADAP-KOOL

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

PRELIMINARY EDITION

ECL Comfort 210/296/310, application A217/A317

RVL470. Heating Controller. Use. Functions. Series B

THERMASREG TR 040 THERMASREG TR 060

KMF Environmental test chamber for constant climate

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

1. Product description

BC3250. Blowdown Controller

intelligent controls for hydronic floor heating

Controller for evaporator control AK-CC 750

english Steca Solar Thermal hot water from the sun. Solar Thermal

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

M2500 Engine Controller Installation Manual

Temperature Controllers

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

for relative humidity and temperature

ECL Comfort 210 / 296 / 310

PROMATIC WDC Heating controllers Energy under control

LC1350 Level Controller

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Constant climate chambers

Use. Functions. Key function. Other functions

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

LCF Touch (from firmware version 1.7)

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVL480. Heating Controller

On the job around the clock 24/7: Fire detection systems

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

LCF Touch Modbus Datasheet Application Security Advice Caution

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Speed and Frequency Seite 1 von 7

Danfoss gas detection units

Copyright AB Regin, Sweden, Corrigo E manual Ventilation application

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

GreenCon On/Off Room Thermostat

Alarm description DECS Contents

GreenCon On/Off Room Thermostat

Better Design, Better Control, Better Systems.

G a

Corrigo E - User Manual Ventilation

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

District heating controller

Hydronic & HVAC Control Systems

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

RVL481. Heating Controller. including d.h.w. heating

Room Temperature Controller

Duct Temperature Sensors

TR 0603mc U Solar Controller

Instructions. VX Solo II. 1.0 Table of contents

Constant climate chambers

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

HRX Technical Manual. Version 1.2

Constant climate chamber with humidity

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Constant climate chambers

SAUTER flexotron800 V2 Ventilation V3.3. manual P P

Immersion Temperature Controller


Solar controllers Energy under control

Products no longer available

Labkotec Ice Detector

Environmental simulation chamber for complex alternating climate profiles

/8 DIN Level Indicator

Constant climate chambers

PIR movement and presence detectors 10 A

SECTION LOW VOLTAGE LIGHTING CONTROLS

RVP310. Heating Controller. Building Technologies HVAC Products

Transcription:

Data sheet ECL Comfort 300 / 301 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 / 301 is an electronic temperature controller which can be loaded with selected applications by means of an ECL Card. The ECL Comfort 300 / 301 controller has triac outputs for motorized valve control and relay outputs for burner/pump/changeover valve control. It is possible to connect up to 6 Pt 1000 temperature sensors and optional plug-in modules. The enclosure is designed for wall and panel mounting. ECL Cards and applications The ECL Comfort 300 / 301 controller can be loaded with a variety of different applications by means of an ECL Card. ECL Comfort 300 with application card type C ECL Comfort 301 with application card type L The ECL Card contains information about application and factory settings. Each application has its own card with corresponding settings. Special applications and/or settings are possible on request. DH-SMT/DK VD.7C.A8.02 Danfoss 09/2006 1

Following applications can be realized together with ECL Comfort 300: Card Code no. Application type description Controller outputs (without accessories) C14 087B4824 Constant temperature control (heating/cooling) of ventilation systems. 2 x 3-point, 2 x 2-point C25 087B4770 Boiler controller with constant temperature control of hot-water circuits and weather 3 x 2-point compensated flow temperature control of systems. C35 087B4761 Weather compensated flow temperature control of systems with fixed return temperature 1 x 3-point, 2 x 2-point limitation. Constant temperature control of secondarily connected hot-water circuits with storage tank with built-in heating coil. Optional ON/OFF control of the hot-water circuit in connection with primarily connected storage tank with built-in heating coil. C37 087B4758 Weather compensated flow temperature control of systems with sliding return temperature 1 x 3-point, 3 x 2-point**) limitation. Constant temperature control of secondarily connected hot-water circuits with storage charging system or storage tank with built-in heating coil. Optional ON/OFF control of the hot-water circuit in connection with primarily connected storage tank with built-in heating coil. C47 087B4821 Weather compensated flow temperature control of systems with sliding return temperature 2 x 3-point, 3 x 2-point**) limitation. Constant temperature control of the hot-water circuits with storage charging system or storage tank with built-in heating coil. C55 087B4783 Boiler controller with constant temperature control of hot-water circuits and weather 1 x 3-point, 3 x 2-point*) compensated flow temperature control of a mixed and an unmixed heating circuit. C60 087B4756 Weather compensated flow temperature control of heating systems with sliding return 2 x 3-point, 2 x 2-point temperature limitation for two independent heating circuits. C62 087B4808 Weather compensated flow temperature control of heating systems with sliding return 2 x 3-point, 2 x 2-point temperature limitation for two independent heating circuits. C66 087B4757 Weather compensated flow temperature control of heating systems with sliding return 2 x 3-point, 2 x 2-point temperature limitation. Constant temperature control of hot-water circuits with flow system or storage tank with built-in heating coil. C67 087B4820 Weather compensated flow temperature control of heating systems with sliding return 2 x 3-point, 3 x 2-point temperature limitation for two independent heating circuits. Constant temperature control of the secondarily connected hot water circuit with storage tank with built-in heating coil. Optional ON/OFF control of hot water circuit in connection with primarily connected storage tank with built-in heating coil. C75 087B4825 Multistage boiler controller with constant temperature control of hot-water circuits and weather compensated flow temperature control of a mixed and an unmixed heating circuit. 1 x 3-point, 4 x 2-point*) *) Relay module ECA 80 is a necessary accessory. **) Relay module ECA 80 is an optional accessory (depending on heating type). Following applications can be realized together with ECL Comfort 301: Card Code no. Application type description L05 087B4870 Weather compensated flow temperature control for heat pump system (up to 2 stages), additional heating circuit and temperature control for domestic hot water circuit. Controller outputs (without accessories) 1 x 3-point, 3 x 2-point L10 087B4874 Flow temperature control for keeping areas snow and ice free. 1 x 3-point, 2 x 2-point L32 087B4854 Weather compensated flow temperature control in combined heating and cooling systems, 1 x 3-point, 5 x 2-point typically floor systems. In addition, dew point and slab temperatures are considered. L66 087B4875 Weather compensated flow temperature control of heating systems with sliding return temperature limitation and twin-pump control. Constant temperature control of hot water circuits with flow system and twin-pump control. 2 x 3-point, 4 x 2-point*) L76 087B4878 Weather compensated flow temperature control of two independent heating systems with sliding return temperature limitation. Constant temperature control of hot-water circuits with flow system and flow switch control. *) Relay module ECA 80 is a necessary accessory. **) ECL Comfort 301 with ECA 83, and Temperature monitoring and alarm module ECA 86 is an optional accessory. 2 x 3-point, 3 x 2-point, 1 x 0-10 volt **) 2 VD.7C.A8.02 Danfoss 09/2006 DH-SMT/DK

Ordering Controller and enclosure Type Designation Code no. ECL Comfort 300 Universal hardware - 230 V a.c. 087B1130 ECL Comfort 300 Universal hardware - 24 V a.c. 087B1134 ECL Comfort 300 with ECA 88 Universal hardware - 230 V a.c. with 2 additional pulse connectors for heat meter 087B1131 ECL Comfort 301 Universal hardware - 230 V a.c. 087B1834 ECL Comfort 301 with Universal hardware - 230 V a.c. with 2 additional analog 087B1836 ECA 83 inputs and 2 analog outputs ECL Comfort 301 with ECA 88 Universal hardware - 230 V a.c. with 2 additional pulse connectors for heat meter 087B1835 Socket - ECL For wall mounting 087B1149 Panel mounting kit For ECL Comfort 087B1148 Mounting kit For DIN-rail 087B1145 Pt 1000 temperature sensors Type Designation Code No. ESMT Outdoor temperature sensor 084N1012 ESM-10 Room temperature sensor 087B1164 ESM-11 Surface sensor 087B1165 ESMB-12 Universal sensor 087B1184 ESMC Surface sensor incl. 2 m cable 087N0011 ESMU-100 Immersion sensor, 100 mm, copper 087B1180 ESMU-250 Immersion sensor, 250 mm, copper 087B1181 ESMU-100 Immersion sensor, 100 mm, stainless steel 087B1182 ESMU-250 Immersion sensor, 250 mm, stainless steel 087B1183 Accessories Type Designation Code no. ECA 60 Room panel with sensor 087B1140 ECA 61 Remote control with 1 zone clock and sensor 087B1141 ECA 62 Room panel with sensors ( C and % RH) 087B1169 ECA 63 Remote control with sensors ( C and % RH) 087B1143 ECA 71 MODBUS communication module 087B1126 ECA 80 Relay module - 2 x SPCO 087B1150 ECA 82 LON - communication module 087B1152 ECA 84 M-Bus - communication module 087B1155 ECA 86 Temperature monitoring and alarm module 087B1158 ECA 87 RS 232 remote control and data log Modem cable (1.5 m) for ECA 87 PC cable (1.5 m) for ECA 87 087B1160 087B1171 087B1172 ECA 99 24 V transformer, Lübke (35 VA) 087B1156 ECA 9010 Override module (for controller time programs) 087B3081 Application example DH-SMT/DK VD.7C.A8.02 Danfoss 09/2006 3

Operation The ECL Card Controller mode Manual operation (used only at maintenance and service) Automatic operation Constant comfort temperature Constant reduced temperature Stand-by mode Circuit indicator Circuit selector Adjustment Change of display Controller mode Arrow buttons. Switch between the lines of the ECL Card. Shift button. Switch between temperatures, changeover points etc. Adjust temperatures and values etc. Circuit selector for switches between circuit I / II. Display example: C 1835 3 19 0 3 6 9 12 15 18 21 24 The display shows all status information about the system. The time and the program is shown in one of the displays which can be selected as a favourite display. The display is also used for the setting of control parameters. Functions ECL Comfort 300 / 301 has a custom-designed display with backlight for monitoring and setting. The controller can be used as master or slave in systems with master/slave controllers. A remote control or room panel can be connected to the system device bus. Optional modules can be inserted into the controller for communication via LON, RS-232, or M-Bus (heat meter). A relay module can be added to extend the performance of outputs if they are used in the selected application. The Auto Tuning function for the automatic setting of control parameters for instantaneous domestic hot water production is available with the ECL Card C66. However, Auto Tuning is only applicable with valves that are approved for Auto Tuning, i.e. the Danfoss types VB 2 and VM 2 with split characteristic as well as logarithmic valves such as VF and VFS. Motor protection, which ensures stable control and a long life of the motorized valve, is available for all ECL C Cards with the exeption of C14 and C25. General data Ambient temperature 0-50 C Storage temperature -40 - + 70 C Enclosure Wall or panel mounting Sensor type Pt 1000 (1000 ohm at 0 C) Grade of enclosure IP 41 - DIN 40050 - marking in accordance with the standards EMC-Directive 89/336/EEC, 92/31/EEC, 93/68/EEC, EN 61000-6-3 and EN 61000-6-1 Low Voltage Directive 73/23/EEC and 93/68/EEC 4 VD.7C.A8.02 Danfoss 09/2006 DH-SMT/DK

Wiring - 230 V a.c. Wiring - 24 V a.c. Supply voltage 230 V a.c. - 50 Hz Voltage range 207 to 244 V a.c. (IEC 60038) Power consumption 5 VA Load on relay outputs 4(2) A - 230 V a.c. Load on triac outputs 0.2 A - 230 V a.c. Supply voltage 24 V a.c. - 50 Hz Voltage range 21.6 to 26.4 V a.c. (IEC 60038) Power consumption 5 VA Load on relay outputs 4(2) A - 24 V a.c. Load on triac outputs 1 A - 24 V a.c. Dimensions DH-SMT/DK VD.7C.A8.02 Danfoss 09/2006 5

Cut-out for mounting Mounting in a panel (connector set, code no. 087B1148): The panel plate thickness A must not exceed 3 mm. Mounting on a wall (socket code no. 087B1149): The plate thickness B must not exceed 1 mm. 6 VD.7C.A8.02 Danfoss 09/2006 DH-SMT/DK

DH-SMT/DK VD.7C.A8.02 Danfoss 09/2006 7

8 VD.7C.A8.02 Danfoss 09/2006 DH-SMT/DK