AIR COOLED CONDENSING UNITS

Similar documents
SEMI-HERMETIC SCREW COMPRESSORS

AIR COOLED CONDENSING UNIT

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - OEMs, Europe. Over

Refrigerated Compressed Air Dryers

Technical Bulletin (TB-0037)

EN-CV: LHCb SciFi Common chiller. Martin Doubek September 25, 2017

Air-cooled Screw Chillers Model RTAF G Process

Water-cooled chillers with High Speed Centrifugal Compressors

Environmentally friendly refrigeration systems for industrial use

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Refrigerant Glide and Effect on Performances Declaration

COMPRESSED AIR TREATMENT

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

New Bitzer factory: Higher precision with air conditioning

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

We optimize performance.

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

Refrigerated Compressed Air Dryers

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

CO 2 transcritical FTE System Full Transcritical Efficiency

DANFOSS OPTYMA PLUS INVERTER UNITS

New Refrigerants & Selecting Capital Equipment

Refrigerants and lubricants

ingersoll rand refrigerated air dryers

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Test Results from the AHRI Low GWP AREP (Alternative Refrigerant Evaluation Program) Bus Air-Conditioning

Optimize your HVAC/R application with the right Danfoss components

Tube-in-tube heat exchanger Type HE

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Advantages of R290 (Propane) and other hydrocarbons

Ingersoll Rand. Refrigerated Air Dryers

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Industrial cooling systems LT

SUSTAINABILITY WITH HIGH DANISH QUALITY

Semi-hermetic GEA Bock Compressors. Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

SUBCRITICAL & TRANSCRITICAL SYSTEMS

DRYPOInt RA. Drying. The concept determines the efficiency. DRYPOINT RA, the most economic way to dry compressed air

Ingersoll Rand. Refrigerated Air Dryers. mb air systems ltd

Process glycol chillers

Air to Water Heat Pump Utilising Natural Refrigerant C02

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

PACKAGED REFRIGERATION CONDENSING UNITS

Emerson Superheat Control. The smart solution for your application

GP SERIES Packaged Chillers

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

R-404A Alternative with Low Compressor Discharge Temperature

BURAN BURAN. Refrigeration Compressed Air Dryers for volume flows from 20 to 850 m³/h

NATURAL REFRIGERANT SYSTEMS

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Low GWP Refrigerants for Air Conditioning Applications

REFRIGERANT CHANGEOVER

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

DC Inverter Smart VRF Products(R410A)

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

CONDOR-H (horizontal) / CONDOR-V (vertical)

F Series - Refrigeration dryers

TRIDENT GS SERIES Central Chiller

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Match your application needs every time

XStream Water-cooled screw chillers and Water/Water Heat pumps

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

R-407A R-448A R-449A

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Air-Cooled Condensing Units with Compact Screw Compressors

Case 8 Basic Performance of Screw Compressor

Pressure Enthalpy Charts

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

Maneurop reciprocating compressors MT / MTZ

PACKAGED REFRIGERATION CONDENSING UNITS

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

EN aquatech.piovan.com

50 barg refrigeration dryers PoleStar Smart HP

Air Cooled Condenser Bitzer

Optyma High Ambient 52 Pack The Cool Outsider, for better Food Preservation

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

PROCESS AND CLIMATE COOLING

Refrigerants & Cooling in renovation buildings

Alternative Refrigerants For Household Refrigerators

BRA FACT FINDER Number 19

REFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Buran DC DC 1175 AES / WB Air cooled / water cooled Refrigeration Dryers

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements

Match your application needs every time

Transcription:

AIR COOLED CONDENSING UNITS 50 Hz // ECOLITE ADVANCED SERIES

BITZER ECOLITE air-cooled condensing units The new ECOLITE air-cooled condensing units for coercial refrigeration perfectly complement BITZER s proven standard LHE and premium ECOSTAR series. It is the ideal solution for cost-conscious customers who are looking for a sustainable and easy to install product made of approved BITZER components. Highly efficient BITZER ECOLINE compressors with capacity control combined with system-optimized condensers and speed-controlled fans make all seven unit models suitable for low and medium temperature applications as standard. Comprehensive equipment and a smart BITZER controller form a comfortable plug and play concept allowing simple implementation in the cooling system and constant monitoring of operating parameters and settings. The ECOLITE series is available for all coon refrigerants, including HFO blends, and fully complies with the EU Ecodesign Product Regulation 2015/1095. Due to its versatility and future-proof design, this new series is a state of the art, affordable line of condensing units featuring the latest BITZER technology. BITZER air-cooled condensing units range Medium temperature t 0 = -10 C, t amb =32 C, t oh =20 C ECOLITE ECOSTAR LHE Low temperature t 0 = -35 C, t amb =32 C, t oh =20 C LHE ECOSTAR ECOLITE 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Cooling capacity [kw] for R449A according to EN 13215 2

Application limits R134a R513A R448A/R449A t amb [ C] 90 70 50 LHL5E/4FES-3Y 30 10 LHL5E/4CES-6Y -10 t = 20 C oh -30-40 -30-20 -10 0 t o [ C] 20 t o t amb t oh Evaporating temperature [ C] Ambient temperature [ C] Suction gas superheat [K] Explanation of model designation Example: L H L 3 E / 2 D E S 2 Y Condenser type 3 = Small housing 5 = Large housing Oil charge Y = ester oil Tentative data Compressor type 3

SYSTEM-OPTIMIZED CONDENSER // Mini channel condenser with high heat transfer rate and low refrigerant charge SPEED-CONTROLLED FANS // Low power consuming fan motor with variable speed controller COMPREHENSIVE EQUIPMENT // Liquid receiver // Sight glass // Filter dryer // High and low pressure switches and transmitters // Oil heater // Suction, discharge and ambient temperature sensors 4

CONTROLLER WITH DISPLAY // Controller including dedicated software created by BITZER with key parameters monitoring // BEST SOFTWARE connectivity for entire system monitoring // Automatic emergency operation PRE-WIRED SWITCH BOARD // Simple coissioning through Plug and Play concept // Main power service switch for fast and easy maintenance SOUND PROOF DESIGN // Unit housing and compressor compartment developed for maximum sound protection BITZER ECOLINE COMPRESSOR // Highly efficient BITZER ECOLINE compressor with VARISTEP capacity control (50% to 100%) Start unloading // Suitable for a wide range of refrigerants including HFO blends with lower GWP (Global Warming Potential) 5

Performance data based on 20 C suction gas temperature with 1K liquid subcooling. Cooling capacity and COP at 32 C ambient temperature. SEPR according to EN 13215. Efficiency ECOLITE Medium Temperature application, Dew point -10 C Low Temperature application, Dew point -35 C R134a R404A R407A R407C R407F R448A R449A R450A R513A R404A R407A R407F LHL3E/2EES-2Y 2,59 3,40 3,30 3,32 3,26 3,30 2,53 2,59 1,40 1,21 1,23 1,24 LHL3E/2DES-2Y 2,53 3,20 3,14 3,17 3,09 3,13 2,50 2,53 1,92 1,22 1,23 1,24 LHL3E/2CES-3Y 3,50 2,96 2,95 3,00 2,89 2,93 2,47 3,49 1,91 1,23 1,69 1,72 LHL5E/4FES-3Y 3,54 3,46 3,32 3,35 3,29 3,33 3,42 3,58 1,85 1,61 1,62 1,66 LHL5E/4EES-4Y 3,71 3,21 3,19 3,24 3,14 3,17 3,63 3,72 1,92 1,67 1,69 1,73 LHL5E/4DES-5Y 3,61 3,05 3,07 3,13 3,02 3,06 3,55 3,61 1,91 1,68 1,70 1,74 LHL5E/4CES-6Y 3,49 2,80 2,86 2,93 2,81 2,84 3,49 3,47 1,89 1,69 1,70 1,74 R448A R449A COP at 32 C SEPR Cooling Capacity Q 0 [kw] ECOLITE Medium Temperature application, Dew point -10 C Low Temperature application, Dew point -35 C R134a R404A R407A R407C R407F R448A R449A R450A R513A R404A R407A R407F LHL3E/2EES-2Y 3,66 5,99 5,29 5,21 5,61 5,49 3,21 3,88 1,90 1,26 1,35 1,37 LHL3E/2DES-2Y 4,32 6,74 6,01 5,89 6,36 6,22 3,79 4,56 2,22 1,49 1,60 1,62 LHL3E/2CES-3Y 5,22 8,12 7,34 7,18 7,76 7,58 4,59 5,49 2,83 1,95 2,08 2,10 LHL5E/4FES-3Y 5,76 9,79 8,91 8,21 9,30 9,09 5,04 6,11 3,26 2,33 2,39 2,42 LHL5E/4EES-4Y 7,44 11,89 10,64 10,00 11,25 11,00 6,53 7,83 4,05 2,74 2,93 2,96 LHL5E/4DES-5Y 8,47 13,34 11,85 11,37 12,52 12,24 7,44 8,93 4,63 3,06 3,27 3,31 LHL5E/4CES-6Y 10,23 15,74 14,43 13,88 15,23 14,87 9,01 10,74 5,52 3,98 4,24 4,28 R448A R449A Optional equipment // Enhanced capacity control from 10% to 100% for LHL5E (second VARISTEP) // Oil seperator with check valve // Oil level monitoring // Start unloading // Liquid receiver with 2 sight glasses and connection for pressure relief valve // Cold room temperature sensor // BEST interface converter for connection to BEST SOFTWARE Tentative data 6

Technical Data Model Weight Fan (s) Receiver volume Compressor Max. power consumption Air flow condenser Max. operating current kg kw m 3 /h dm 3 A LHL3E/2EES-2Y 163 0,12 3000 7,8 6,56 LHL3E/2DES-2Y 163 0,12 3000 7,8 8,06 LHL3E/2CES-3Y 163 0,12 3000 7,8 9,66 LHL5E/4FES-3Y 222 0,24 6000 15,0 10,06 LHL5E/4EES-4Y 222 0,24 6000 15,0 12,76 LHL5E/4DES-5Y 222 0,24 6000 15,0 15,06 LHL5E/4CES-6Y 222 0,24 6000 15.0 18.26 Dimensional Drawing 11 M8x30 (max.) 4 11 ØB M8x30 (max.) 1 ØA X Y C 446 46 459 648 648 80 12 M20 13 12 63 F 403 449 5 1253 Connections 1 Refrigerant inlet (suction gas line), SL 4 Refrigerant outlet, DL 11 Load suspension points 12 Plug for srewed cable gland 13 Cable bushing (for cables 9 17) Type ØA ØB C F X LHL3E/2EES-2Y.. LHL3E/2CES-3Y 22 12 830 334 520 575 Y LHL5E/4FES-3Y.. LHL5E/4CES-6Y 28 16 1230 332 520 575 Example shows LHL5E/4FES-3Y.. LHL5E/4CES-6Y Tentative data 7

BITZER Kühlmaschinenbau GmbH Eschenbrünnlestraße 15 // 71065 Sindelfingen // Germany Tel +49 (0)70 31 932-0 // Fax +49 (0)70 31 932-147 bitzer@bitzer.de // www.bitzer.de Subject to change // 80112101 // 07.2018