SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

Similar documents
How can you minimize consequential damages in case of a fire?

KD Innovative extinguishing with Novec TM 1230 by 3M TM

How can I protect invaluable assets and the environment from the effects of a fire?

FIRE SUPPRESSION SYSTEM

3M Novec Fire Protection Fluid

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Fire suppression systems for server rooms and data centres

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

BOC FS125 The Fire Extinguishing Solution

GX-20/FM-200 Fire Extinguishing System

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Superior by Design The Kidde ADS TM FM-200 System

What extinguishes fires without pressure peaks?

Safe, Effective, Environment-friendly

HFC-227ea FIRE SUPPRESSION SYSTEM

Fire Protection in the Mining Industry. Garry Kwok Board Member

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

Rick Seidel Fike Corporation Regional Sales Manager

What provides highly reliable fire protection?

C L E AN A G ENT FIRE SUPPR E SSIO N S Y S T E M S

Fire Extinguishing Agents for Protection of Occupied Spaces in Military Ground Vehicles

Sinorix Silent Extinguishing Technology protecting the quiet way

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Welcome to Argonite fire protection from Ginge-Kerr

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Certificate of Conformity Certificate num. Registration date Version Valid until

PACKAGED REFRIGERATION EQUIPMENT

Water Mist Fire Suppression

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

ODS & SGG Alternatives for the Fire Protection Industry 2018

Fire Protection for Cable Tunnels

Chapter 2. Alternatives to HCFCs and their Characteristics

AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION

Solutions at every turn.

STAT X - SPECIAL HAZARD FIRE PROTECTION

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

An Overview of Extinguishing Systems for Computer Equipment

Saving Energy and the Environment with the latest developments in Heat Pipe Technology

Simple On The Outside...

Pre-Engineered Fire Suppression

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

ASSEMBLY 37TH SESSION

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Protecting Backup Generators and UPS Systems Against Risk of Fire

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Design of LPG Refrigeration System

investment in R&D, the commitment to - name.

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

FIRE SUPPRESSION SOLUTIONS

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Fire protection for buildings

Fire Protection for Servers and Telecoms

Sprinkler Solutions for Storage Applications

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Brazed Plate Heat Exchanger for CO Applications

Making equipment decisions

DECLARATION OF PERFORMANCE ref. no

Scroll Chillers Transition from HCFC-22 to HFCs

XC10 combined fire detection and extinguishing control

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

HFCs or the Old Refrigerants - what is the best Choice?

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Centrum stavebního inženýrství a.s.

Ammonia. Background on ammonia as a refrigerant

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Study of R161 Refrigerant for Residential Airconditioning

MISSION CRITICAL FIRE PROTECTION

Issue 70 June 2017 THE GLOBAL VOICE FOR PASSIVE AND ACTIVE FIRE PROTECTION

JOB THERMO BULBS PRODUCT RANGE

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

CO2 COCO GAS FLOODING SYSTEM

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

XC10 combined fire detection and extinguishing control

Centrum stavebního inženýrství a.s.

Solutions. Fire risk under control in welding fume extraction systems

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Protezione antincendio di dati e business critical assets nei Data Centers

Transcription:

SAPPHIRE Gaseous Fire Suppression Systems Delivering 3M Novec 1230 Fire Protection Fluid

SAPPHIRE Gaseous Fire Suppression Systems Delivering 3M Novec 1230 Fire Protection Fluid HYGOOD SAPPHIRE Fire Suppression System delivering 3M Novec 1230 Fire Protection Fluid is an environmentally friendly clean agent system, and the solution of choice for protecting people and high value assets. HYGOOD SAPPHIRE systems provide a proven and reliable fast acting, clean agent solution that is safe for use in occupied spaces. The system is environmentally friendly with zero ozone depletion potential (ODP) and negligible global warming potential (GWP). HYGOOD SAPPHIRE systems are specifically designed and developed based on independently witnessed fire tests. It is listed as acceptable without restrictions by the US Environmental Protection Agency s Significant New Alternatives Policy (SNAP). Every HYGOOD SAPPHIRE installation carries a 20 year environmental warranty. For more information please contact your local approved HYGOOD distributor for full details.

Protecting our world Almost every aspect of modern life has a direct or indirect effect on the environment. With increasing demand for awareness and action regarding environmental issues, HYGOOD SAPPHIRE systems help reduce environmental impact. Novec 1230 fluid has zero ozone depletion potential and a global warming potential of just one. The atmospheric lifetime is between three and five days making HYGOOD SAPPHIRE an ideal solution without compromising the environment. Playing Safe HYGOOD SAPPHIRE systems are ideal for use in occupied areas. Independent toxicity studies have established that the agent is very low in both acute and chronic toxicity with high safety margins between its normal use concentrations and the No Observable Adverse Effect Level (NOAEL). Fast acting suppression HYGOOD SAPPHIRE systems work fast and are designed to rapidly absorb heat to the point where combustion ceases. Once actuated, HYGOOD SAPPHIRE systems deliver the extinguishant within 10 seconds, stopping fires before they have the chance to spread. Most importantly when a fire is suppressed quickly, the result is less damage, lower refurbishment costs and reduced downtime. System recharging Filling and recharging HYGOOD SAPPHIRE systems is straight forward as the agent s high boiling point of 49 C means the agent can be transported in lightweight drums rather than pressurised containers. Air freighting and other transport methods are possible for transporting unpressurised HYGOOD SAPPHIRE containers. Compact low pressure technology HYGOOD SAPPHIRE systems are compact and operate at both 25 and 42 bar, and have been proven to achieve homogeneous distribution of agent at these pressures complying with international standards and meeting the requirements of approval agencies globally. Agent comparison Properties Novec 1230 HFC 125 HFC 23 HFC-227ea Ozone depletion potential (ODP) 0 0 0 0 Global warming potential 1 3,500 14,800 3,220 Atmospheric lifetime (years) 0.014 29 270 24.2 SNAP* Yes Yes Yes Yes *SNAP - Significant New Alternatives Policy (US EPA) Environmental data from 4 th Assessment report of IPCC 2007 and EPA s tables of ozone depleting substances

Trusted gaseous solutions using pioneering technology

SAPPHIRE Gaseous Fire Suppression Systems Delivering 3M Novec 1230 Fire Protection Fluid // Fast Acting // Easy to Refill // Compact Storage // Environmentally Friendly // Safe for People // International Approvals Approvals // LPCB // VdS // UL // FM // VNIIPO // GOST // CNPP 32673 SAPPHIRE

Global strength. Local expertise. At your service. Contacts Company headquarters and branch office JIHLAVA KLIKA-BP, a.s., o.z. Jihlava 8. března 4812/2a 586 01 Jihlava Czech Republic tel.: +420 567 304 221 fax: +420 567 331 418 e-mail: klika@klika.cz KLIKA-BP, a.s. - registered office V Jirchářích 148/4 110 00 Praha Czech Republic IČ (ID No.): 25555316, DIČ (VAT No.): CZ25555316 The company is registered in the Commercial Register administered by the Municipal Court in Praha, section B, file 17988 KLIKA-BP Slovakia, s.r.o. Branch office VYSOKÉ MÝTO KLIKA-BP, a.s., o.z. Vysoké Mýto Dráby 850 566 01 Vysoké Mýto Czech Republic tel.: +420 465 422 639 fax: +420 465 422 636 e-mail: lenka.karelova@klika.cz Tomášikova 30 821 01 Bratislava Slovak Republic tel.: +421 258 104 000 fax: +421 258 104 001 e-mail: klika@klika.sk IČO (ID No.): 43995888, DIČ (VAT No.): 2022582232 IČ DPH (VAT ID No.): SK2022582232 The company is registered in the Commercial Register administered by the District Court Bratislava I, section Sro, insert 50962/B www.tfppemea.com Email: marcoms-emea@tyco-bspd.com Copyright 2012 Tyco Fire Products LP. All rights reserved