BS 476: Part 6: 1989+A1:2009

Similar documents
BS 476: Part 6: 1989+A1:2009

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

BS EN ISO : 2010

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

BS EN ISO : 2010

BS EN : 2001 & IEC :2000

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : 2010

NF X : Parts 1, 2, 3, 4 & 5

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Review Fire Test Report

IMO Resolution MSC 61(67): Annex 1: Part 2

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

Fire Test Reports for Interpon D Powder Coatings

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

25 th November Title:

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

CERTIFICATE OF APPROVAL No ME 5085

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

Test Report: ICL/H18/9039 Rev 1

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Abrasion Resistance of Fluoropolymer and polyester Coatings

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report No: ICL/H17/7967

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Loss Prevention Standard

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

Exova Warringtonfire - Expert Witness Directory 2018

Classification of Fire Performance of Wall and Ceiling Lining Materials

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Report Number BTC 15450A

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

FTSG RESOLUTIONS. This document of FTSG resolutions was issued by the Company Secretary 20 July 2012.

CERTIFICATE OF APPROVAL No CF 136

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

FUNDERMAX GMBH FIRE TEST REPORT

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

GASTEC QA. Approval Requirements 136

BCTC CARPET TECHNICAL CENTRE

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

ISO INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

Public Comment No. 2-NFPA [ Section No ]

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria


Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Classification report

Analysis Report

Testing coated fabrics

Loss Prevention Standard

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

GASTEC QA. Approval Requirements 31-1

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

Coatings for protection of FRP structures with heavy rain erosion loads

TFI Report Reaction to fire test

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

Your Key to achieving C.E Marking Compliance

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

Transcription:

Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 6: 1989+A1:2009 Method Of Test For Fire Propagation For Products A Report To: Document Reference: 354660 Date: 28 th July 2015 Page 1 Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429 This report in issued in accordance with our terms and conditions, a copy of which is available on request.

Executive Summary Objective To determine the performance of the following product when tested in accordance with BS 476: Part 6: 1989+A1: 2009. Generic Description Product reference Thickness Weight per unit area or density Flame retardant grade foam material adhered to a steel substrate ThermaSmart Pro Sheet 13mm 25-35kg/m 2 * Individual components used to manufacture composite: Foam (test face) ThermaSmart Pro Sheet 13mm 25-35kg/m 3 Adhesive Thermaflex Glue 0.2mm 0.25kg/m² Substrate S235 Blank Steel 3mm 7800kg/m 3 *Determined by Exova Warringtonfire Please see page 5 of this test report for the full description of the product tested Test Sponsor, Veerweg 1, 5145 NS Waalwijk, The Netherlands. Test Results: Fire propagation index, I = 4.3 Sub index, i 1 = 2.8 Sub index, i 2 = 0.2 Sub index, i 3 = 1.3 Date of Test 24 th July 2015 Signatories Responsible Officer C. Meachin * Technical Officer Authorised S. Deeming * Business Unit Head * For and on behalf of Exova Warringtonfire. Report Issued: 28 th July 2015 This version of the report has been produced from a.pdf format electronic file that has been provided by Exova Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Exova Warringtonfire. Document No.: 354660 Page No.: 2 of 10

CONTENTS PAGE NO. EXECUTIVE SUMMARY... 2 SIGNATORIES... 2 TEST DETAILS... 4 DESCRIPTION OF TEST SPECIMENS... 5 TEST RESULTS... 6 Table 1... 7 Table 2... 8 Table 3... 8 REVISION HISTORY... 10 Document No.: 354660 Page No.: 3 of 10

Test Details Purpose of test To determine the performance of a product when it is subjected to the conditions of the test specified in BS 476: Part 6: 1989+A1: 2009, "Fire tests on building materials and structures, method for fire propagation for products". The test was performed in accordance with the procedure specified in BS 476: Part 6: 1989+A1: 2009, and this report should be read in conjunction with that British Standard. Scope of test Fire test study group/egolf Instruction to test Provision of test specimens BS 476: Part 6: 1989+A1: 2009 specifies a method of test, the result being expressed as a fire propagation index, that provides a comparative measure of the contribution to the growth of fire made by an essentially flat material, composite or assembly. It is primarily intended for the assessment of the performance of internal wall and ceiling linings. Certain aspects of some fire test specifications are open to different interpretations. The Fire Test Study Group and EGOLF have identified a number of such areas and have agreed Resolutions which define common agreement of interpretations between fire test laboratories which are members of the Groups. Where such Resolutions are applicable to this test they have been followed. The test was conducted on the 24 th July 2015 at the request of Thermaflex International, the sponsor of the test. The specimens were supplied by the sponsor of the test. Exova Warringtonfire was not involved in any selection or sampling procedure. Conditioning specimens of The specimens for testing to BS 476: Part 6: 1989+A1: 2009 together with the specimens for testing to BS 476: Part 7: 1997 were received on the 15 th July 2015. Prior to the tests, all of the specimens were conditioned to constant mass at a temperature of 23 ± 2 C and a relative humidity of 50 ± 5%. One specimen from the total sample submitted for test was selected for constant mass verification. Form in which the specimens were tested Exposed face Assembly - Fabrication of materials and/or composites that can contain air gaps. An air space was provided at the back of the product by testing over spacers of non-combustible insulation board 20 mm wide and 12.5mm thick. The foam face of the specimens was exposed to the heating conditions of the test. Document No.: 354660 Page No.: 4 of 10

Description of Test Specimens The description of the specimens given below has been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. General description Flame retardant grade foam material adhered to a steel substrate Product reference ThermaSmart Pro Sheet Name of manufacturer Thermaflex Isolatie B.V. Thickness 13mm (stated by sponsor) 15.1mm (determined by Exova Warringtonfire) Weight per unit area 23.9kg/m 2 (determined by Exova Warringtonfire) Generic type Polyolefine See Note 1 Below Product reference ThermaSmart Pro Sheet Detailed description Direct extruded polyethylene foam Name of manufacturer Thermaflex Isolatie B.V. Foam Thickness 13mm Density 25-35kg/m³ Colour reference Anthracite Trade name of flame retardant Thermabatch Generic type of flame retardant Halogen Amount of flame retardant 10% Generic type See Note 1 Below Product reference Thermaflex Glue Name of manufacturer SABA Colour reference Green Adhesive Application thickness 0.2mm Application rate 0.25kg/m² Application method Trowel Flame retardant details See Note 2 Below Curing process See Note 1 Below Generic type Steel Product reference S235 Blank Steel Name of manufacturer Wilwy Substrate Thickness 3mm Density 7800kg/m³ Colour reference Grey Flame retardant details The component is inherently flame retardant Brief description of manufacturing process See Note 1 Below Note 1: The sponsor was unwilling to provide this or further information. Note 2: The sponsor of the test has confirmed that no flame retardant additives were utilised in the production of the component. Document No.: 354660 Page No.: 5 of 10

Test Results Results A total of three specimens were tested. The laboratory record sheet relating to each of the test specimens is appended to this report (refer to Tables 1, 2 and 3). Throughout the test on each specimen careful observation was made of the product's behaviour within the apparatus and special note was taken of any of the phenomena listed in clause 9.2 of the Standard. None of the listed phenomena was observed and the test results on all three specimens tested were valid. The following test results were obtained for the product. Fire propagation index, I = 4.3 Sub index, i 1 = 2.8 Sub index, i 2 = 0.2 Sub index, i 3 = 1.3 Applicability test result of NOTE: If a suffix 'R' is included in the above fire propagation index, I, then this indicates that the results should be treated with caution. The test results relate only to the behaviour of the test specimens of the product under the particular conditions of test; they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. The test results relate only to the specimens of the product in the form in which they were tested. Small differences in the composition or thickness of the product may significantly affect the performance during the test and may therefore invalidate the test results. Care should be taken to ensure that any product which is supplied or used is fully represented by the specimens which were tested. Validity The specification and interpretation of fire test methods are the subject of ongoing development and refinement. Changes in associated legislation may also occur. For these reasons it is recommended that the relevance of test reports over five years old should be considered by the user. The laboratory that issued the report will be able to offer, on behalf of the legal owner, a review of the procedures adopted for a particular test to ensure that they are consistent with current practices, and if required may endorse the test report. This report may only be reproduced in full. Extracts or abridgements shall not be published without permission of Exova Warringtonfire. Document No.: 354660 Page No.: 6 of 10

Table 1 Laboratory Record Sheet FIRE PROPAGATION TEST - BS476:PART 6:1989+A1:2009 Specimen No. : 1 Date : 24-Jul-15 Time Specimen Calibration Sub Index mins Temperature Temperature Ts- Tc/10t Of Deg C Deg C Performance t Ts Tc 0.50 18 12 1.20 1.00 24 18 0.60 1.50 28 23 0.33 2.00 32 27 0.25 2.50 35 31 0.16 3.00 40 36 0.13 2.68 4.00 75 71 0.10 5.00 109 109 0.00 6.00 135 137 0.00 7.00 156 159 0.00 8.00 170 174 0.00 9.00 184 188 0.00 10.00 199 199 0.00 0.10 12.00 268 215 0.44 14.00 296 223 0.52 16.00 281 230 0.32 18.00 262 236 0.14 20.00 257 243 0.07 1.50 Total Index of Performance S = 4.27 SubIndex s1 2.68 SubIndex s2 0.10 SubIndex s3 1.50 Index of Performance S 4.27 Document No.: 354660 Page No.: 7 of 10

Table 2 Laboratory Record Sheet FIRE PROPAGATION TEST - BS476:PART 6:1989+A1:2009 Specimen No. : 2 Date : 24-Jul-15 Time Specimen Calibration Sub Index mins Temperature Temperature Ts- Tc/10t Of Deg C Deg C Performance t Ts Tc 0.50 19 13 1.20 1.00 26 19 0.70 1.50 30 25 0.33 2.00 35 30 0.25 2.50 38 33 0.20 3.00 41 38 0.10 2.78 4.00 77 67 0.25 5.00 109 105 0.08 6.00 133 132 0.02 7.00 150 151 0.00 8.00 164 169 0.00 9.00 176 182 0.00 10.00 184 191 0.00 0.35 12.00 201 207 0.00 14.00 284 218 0.47 16.00 305 226 0.49 18.00 275 235 0.22 20.00 253 239 0.07 1.26 Total Index of Performance S = 4.39 SubIndex s1 2.78 SubIndex s2 0.35 SubIndex s3 1.26 Index of Performance S 4.39 Document No.: 354660 Page No.: 8 of 10

Table 3 Laboratory Record Sheet FIRE PROPAGATION TEST - BS476:PART 6:1989+A1:2009 Specimen No. : 3 Date : 24-Jul-15 Time Specimen Calibration Sub Index mins Temperature Temperature Ts- Tc/10t Of Deg C Deg C Performance t Ts Tc 0.50 18 12 1.20 1.00 25 18 0.70 1.50 30 23 0.47 2.00 33 27 0.30 2.50 37 31 0.24 3.00 41 36 0.17 3.07 4.00 75 71 0.10 5.00 102 109 0.00 6.00 130 137 0.00 7.00 151 159 0.00 8.00 170 174 0.00 9.00 184 188 0.00 10.00 207 199 0.08 0.18 12.00 274 215 0.49 14.00 273 223 0.36 16.00 259 230 0.18 18.00 249 236 0.07 20.00 247 243 0.02 1.12 Total Index of Performance S = 4.38 SubIndex s1 3.07 SubIndex s2 0.18 SubIndex s3 1.12 Index of Performance S 4.38 Document No.: 354660 Page No.: 9 of 10

Revision History Issue No : Revised By: Reason for Revision: Re-issue Date: Approved By: Issue No : Revised By: Reason for Revision: Re-issue Date: Approved By: Document No.: 354660 Page No.: 10 of 10