Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC).

Similar documents
LOW PRESSURE SYSTEM INSTALLATION GUIDE

To dismantle and reassemble domestic Gas Geyser i.e. Gas Water Heater

Installation Instructions for. OmniFount

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Installation Instructions for. OmniFount

Installation Instructions

Installation Instructions for. OmniFount

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

INDIRECT SYSTEM FOR FROST LOCATIONS

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Copper convection heaters:

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Enzo Concealed Shower Mixing Valve

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

OVATION 56 EGG INCUBATORS CLEANING / SERVICE GUIDE

INSTALLATION INSTRUCTIONS For The "North" Wood Burning Cook Stove energy saving Hot Water Kit

For our present, For their future. Version 11.04

Hoshizaki America, Inc.

HE120, HE160 Humidifier Installation Kit

ALPHA HEATING & SOLAR NZ LTD (AHS)

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Hoshizaki America, Inc.

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

ADVANCE ELECTRIC THERMAL STORE

Retrofit an evacuated tube collector to an existing cylinder Updated

Hoshizaki America, Inc.

MIX Boiler & Font Range Service Manual

The instruction to installers for a. 150 lt split direct pumped EVT retrofit system

Installation Instructions for. CattleMaster Series Fountains

Installation & User Guide

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

The instruction to installers for a. Satchwell HOTFLO Integral EVT cistern type system

GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual. for the. GT 120 Family and GT 330

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Mix Boiler & Font Range ( #, #, #, , )

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

CENTRA-COIL QUALITY HOT WATER SERVICE

SUPPLEMENTARY INSTRUCTIONS

Installation Instructions for. DairyFount Series Fountains

Avensys Avensys FIN EST SLO RUS UAE

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

SAN JUAN FRESH WATER COOLING SYSTEMS

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Thermostatic Concealed Shower Valve

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

General System Layout Sketch

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

SCN60 Residential Nugget Ice Machine

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

If you are a beginner please feel free to contact us at any time regarding our electroplating course for beginners.

SUN EQUINOX HEATING SYSTEMS

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Patio Heater Model No. GM and GM

Spare Parts Guide & Price List

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Avensys Avensys FIN EST SLO RUS UAE

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Model LF-310 Air Operated

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

CalMag Filter Installation Instructions

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE AccessPRO Right Height Elongated 2-piece Toilet Model 215AG Series

SPLIT WALL-MOUNTED AIR CONDITIONER

Pro-Clean Stratified Tank scope of delivery:

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

General System Layout Sketch

Operation / Installation Manual

HOME INSPECTION CHECKLIST

64 Beverage dispensing

Installation. S Series Navigator Thermostatic Mixing Valve

Installation & Operating Instructions

CIRCO 6 Solar Circulation Unit

INSTALLATION, OPERATION AND REPAIR MANUAL GAS KETTLE KGL-T KET-07 (216) CLEVELAND RANGE INC East 179th St. Cleveland, Ohio U.S.A.

Repair Parts List DISHWASHER MODEL NUMBER DW871UQA. When requesting service or ordering parts, always provide the following information:

Five reasons to buy a solar water heater:

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER ANSWER SCHEDULE

Instructions for CO 2 Cold Trap System. Part No

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Fountain Classic. Installation and Owner s Manual. Page 16

Bottled Water Dispenser

Handshower, Hose & Handshower Accessories

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

Telo Shower Mixing Valve TL10016CP

SERVICE MANUAL UBER FONT

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

Installation Instructions

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Installation Manual Thermosiphon - Indirect

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

Transcription:

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC). Please follow the installation instructions carefully, AND check the final installation according to the instructions. The Xstream VACUSTREAM HWC is a cistern-fed (open to air) dual-tank hot water system. These dual-tank systems consist of a cistern tank ( Supplystream ) which is a feeder tank that is positioned on top of the hot water storage tank ( Vacustream ). Vacu in this context refers to the solar heating, or absorption component - in this case low pressure, 47 mm diameter vacuum tubes. These low pressure tubes work on a convection principle - the tubes are connected directly to the hot water storage tank and through convection transfer the heat that builds up inside the tubes to the storage tank. From here the hottest (lightest) molecule rises to the top. This process repeats itself. These tubes are freeze protected to -6 ºC and therefore ideally suited for frostprone areas. The Vacustream tank is made of a corrosion free material. No sacrificial anodes are used. The tubes used with the Vacustream solar system are hail resistant. Model: Vacustream (Non electrical) Installation procedure: Position the frame on a flat surface, pointing north. (Photo 1: completed installation). Lift the rear end of the frame and fasten the uprights onto rear flat frame. Secure with supplied bolts and nuts. Install the rear support. Attach the four swivel feet. (Photo 2). Should the installation be done on a sloped roof, the rear legs of the frame can be shortened, and the swivel feet re-positioned (8 mm holes are to be drilled in the new position). Ensure that the Vacustream is in all instances installed at 90 degrees to horizontal to ensure the proper operation of the hot water draw-off and the float valve in the Supplystream. Place the Vacustream on the flat area of the erected frame. Secure the tank by fastening the stainless steel straps, positioned as shown in photo 3 line up the straps to be centrally located between holes 2 and 3 both ends of the Vacustream tank. (Photo 3) Position the tube-end piece at the bottom of the frame and hand tighten bolts - do not fasten - just keep the end frame in position. (Photo 4)

Place the tube-end caps into the tube-end piece. (Photo 5). Insert the silicon rubbers into the Vacustream tank, tapered end facing outwards. (Photo 6) Insert the tubes into the silicon rubbers inside the tank immerse the tube in a soapy solution before it is pushed into the rubber. Push the tube deeper into the Vacustream, lifting the bottom over the end piece at the bottom, and then slide it back, securing it into the end cap holder. (Photo 7). Ensure that the bottom piece of the tube rests securely inside the end cap. (Photo 8) Once in place properly fasten and secure tube-end plate. Position the cistern tank (Supplystream) on top of the Vacustream tank. (Photo 9). Connect the supplied plumbing between the cistern tank (Supplystream) and the Vacustream, using two spanners to keep the rear end in position. Connect the incoming cold line to the cistern tank inlet - support the pipe. Connect the Supplystream tank-outlet to the Vacustream inlet. Do not remove these fittings, simply apply the necessary torque to ensure a proper seal on the supplied compression ring. (These fittings are factory prepared). Connect the hot water supply line to the outlet of the Vacustream: Place the Supplystream cover over the cistern tank and connect the vent pipe from the Vacustream to the Supplystream. Secure the Supplystream lid with two (shorter) stainless steel straps and buckles. (Photo 10,11,12 and 13) Check all fittings for leaks, and ensure all supply lines are properly fastened and secured to fastening points; thereby minimizing strain on the fittings attached to the Supplystream tank and Vacustream. Fasten all the joining points on the frame. Connect the overflow from the Supplystream. Never remove the supplied copper fittings from the Vacustream. Keep the tubes cool by shading them from the sun before the cold (main) supply is opened to prevent damage to the tubes (thermal shock). Maintenance: Float valve The float valve used in the system may require cleaning of the inline sleeve from time to time, depending on the water quality. Remove the top lid from the Supplystream, and inspect the water inlet from the float valve. If needs be, remove the sleeve (located inside the inlet connection of the valve, clean it and replace. Re-connect the water supply.

Tubes The tubes may form a scale built-up over time depending on water quality. Remove the tubes, and using an extended bottle brush and any type of descaler/white vinegar solution, clean the inside of the tube. Rinse with clean water and replace. Plumbing Inspect the plumbing connections from time to time to ensure no dripping from fittings. Fasten if required. Safety issues The hot water supply from these systems may reach very high temperatures and it is therefore advisable to connect an inline tempering valve, securing a constant temperature at preset temperatures. Working components Float valve: A valve regulating the flow and water level inside the Supplystream feeder tank. Drain valve: Situated at the bottom of the Vacustream storage tank to allow for draining of the tank. Refer to various pictures included. Other information supplied with the system (applied onto Vacustream tank) FREEZE RESISTANT HAIL RESISTANT Manufacturer of geyser: Trade name: Trade mark: Working pressure: Model: Hail resistant: Freeze resistant: Tube material: Energy rating: Aperature area: System Information Xstream Solar Hot Water Cylinders (Pty) Ltd Xstream Vacustream 0 kpa Vented Vacustream 12/47/1500 YES / NO YES / NO Glass 2mm thickness Q-factor: 12.983 1m² (1.75m x 0.047m x 12) Please contact our Service Desk on +27 21 872 0900 if any further assistance is required. Think Energy Think Energy Saving Think Xstream Hot Water Cylinders ENJOY THE HOT WATER SUPPLIED BY YOUR XSTREAM VACUSTREAM HOT WATER CYLINDER!

Tel: +27 21 872 0900 Fax: +27 21 872 8604 E-mail: info@xstream.co.za Website: www.xstream.co.za Distillery Road Paarl 7646 PO Box 3132 Paarl 7620 Serial number prefix: 2B