Hudevad P5. Technical datasheet

Similar documents
Hudevad Plan. Technical datasheet

P r o d u c t c a t a l o g u e

P r o d u c t c a t a l o g u e

PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

T6 - Centrally Connected & VONOPLAN T6.

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

Heating. Our range of designer radiators and towel rails, brings fashion and function together beautifully. By Style

Metropolitan high output natural and powered trench heaters

LOW SURFACE TEMPERATURE RADIATORS

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Environmental and oil cabinets The optimum storage area for liquids

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Type CODE Speed Heating Cooling

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATOR

CASSETTE UNIT. Comfort Circle

2 DESCRIPTION OF SYSTEM COMPONENTS

Heating Emitters. Find the right radiator for each room. Radiators Towel Warmers Towel Warmer Valves 295

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Radiators, Towel Warmers and Trench Heating

Commercial Heating Domestic Heating

Cooling Strip Model SPB

Convectors Steam / Hot Water November, 2009

VERTICAL VONOVA & VERTICAL VONOPLAN. 20 VERTICAL VONOVA & VERTICAL VONOPLAN PANEL RADIATORS. VERTICAL VONOVA Type 20. VERTICAL VONOPLAN Type 20.

Presentation new platform products

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

[ KoRALIne. FRee StAnDInG ConVeCtoRS (natural convection)

ALTO DRAWER SYSTEMS .hafele.com.au Dimensions in mm 2018 www

DC340 Rack and pinion door closer with guide rail or link arm

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

Sovereign Double CC/DD

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

Electric Cast Iron Radiators

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

TC MODULE (FFD) (with Gas Hob)

UK 01/2014 BEAMS COLLECTION VASCO ALUMINIUM RADIATOR

PLAN KLASIK LINE KLASIK

Passive chilled beams

Floor Heating & Heated Towel Rails Product Catalogue

Installation instructions Page 12. Multi-temperature wine cabinet EWTdf 1653 / 2353 / 3553

Pleated blinds, free hanging units FS, FK, FE Description

Optimal work climate with open doors. Industrial air curtains Model IndAC

Sill Line Perimeter Casing. Warmline Trench Heating. Vectair Natural Convectors. Spirally Wound Gilled Tube

Heat Emitter Supplement To the Domestic Heating Design Guide

enviroblinds external blinds & shutters the secret to low carbon comfort

shower panel specification manual 2008

Units for suspended ceilings

07/ OUR COLLECTION OF DESIGNER RADIATORS AND TOWEL RAILS INSPIRE WARMTH AND ELEGANCE IN ANY BATHROOM. HEATING20. guarantees unless otherwise stated

MEGABAND * MICA INSULATED BAND HEATERS. Construction overview Clamping mechanisms Termination styles Construction styles Watt density information

Thermostatic valves with radiator connection systems

at in Bathroom radiators are where fashion and function come together in perfect harmony. With everything

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Kenya s Official Distributor of GutterFlow Products

ECOLEC PANEL HEATERS GENERAL NOTES.

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

Trench Heating. Katherm NK

ALTO DRAWER SYSTEMS. exclusively Brought to you by Häfele.

CR A-F-A-E-HQQE 3x400/ HZ

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

Phoenix Thermal Supply

UNDERSTANDING SAFETY CABINETS

Installation, Operation & Maintenance Instructions Document Ref:

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

Multilux 4-Eclipse-Set

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Cast Iron Radiators. General Information 2. Block make up 6.

Twin Wall Installation Instructions And Maintenance Guide

Linea Plus. Freestanding. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Polaris-I-60. active chilled beam. the future of space conditioning

Varsity Concealed Shower System

COMPONENT SOLUTIONS for the lighting industry

onlinecomponents.com 144

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

SLIM-LINE RC FAN CONVECTOR.

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

Providing Natural Solutions to Heating

OPTIMIZED CONVECTION. unique heating technology. Catalogue

DC200 Rack and pinion door closer with link arm

Mineral Insulated Band Heater

DESIGNER RADIATORS.

Automatic balancing valves ASV-PV (new generation) DN 32-50

planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

1. Description. 2. List of Accessories included

Equihunter Horseboxes, Felbridge Show Centre, Copthorne Road, Felbridge, East Grinstead, West Sussex, RH19 2NU. m: +44 (0)

doc.m rimless super pack

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

INDUSTRIAL AIR CURTAIN. IndAC 2

Transcription:

Technical datasheet

Key benefits Kundenedfald Grøn energi Minimalistic Scandinavian design Matches any architecture Sikkerhed Energi Water-filled front panel High quality 2 mm Swedish steei for the best output and construction Fully welded solution No removable parts making it highly durable and completely tamper-proof Fully customisable Large range of sizes, tapping options, colours, infill panels, angles, and closed ends 2

Index Description... 4 Illustrations... 5 Dimensions... 6 Height and length...6 Tapping distances...7 Build-in dimensions... 8 Position of rails...9 Built-in valves...9 UR Flex... 12 Output... 17 Options... 18 Angled radiators... 18 Horizon infill panel... 19 Accessories... 20 Brackets...20 Adjustable PR feet... 21 Console feet...23 Tappings... 23 UR Flex tappings...24 3

Description Hudevad P5 is the embodiment of clean design and reliable output. The look and feel of the P5 radiator, or any of its variants, is Scandinavian simplicity at its finest. The P5 radiator has a high output, is sturdy, stable and is truly an asset as an architectural tool. The P5 has a smooth, flat rebated front plate with solid top and bottom and pressed steel vertical waterways. Water circulates directly behind the front plate. The P5K has convector fins welded on to the rear side of each plate. Material Front plate: 2.00 mm steel to EN 10051 Rear plate: 1.25 mm steel to EN 101 P5K convector fins: 0. mm steel to DIN 239 Test pressure 10 bar Max. operating pressure 7.7 bar in accordance with EN 442 Max. operating temperature 95 C Surface treatment Length Height Depth Pretreatment: Degreasing and passivation Priming: Primed with water based paint in pale grey Surface treatment in accordance with DIN 55900 and EN 442 P5/P5K and P5D/P5KD: 0-00 mm, in increments of 33.33 mm Radiator lengths above 20 mm are with open ends P5/P5K and P5-D/P5K-D: 0, 0, 0, 600, 700 and 1000 mm P5: mm / height 1000 mm: 43 mm P5K: 58 mm P5D: 105 mm / height 1000 mm: 108 mm P5KD: 123 mm Tappings 1/2 standard, adapter for 3/4 Installation Optional extras Wall or floor mounted Brackets are included Air vents and plugs are included Console feet FH PR feet Adjustable brackets Closed ends (standard with UR-flex) Colour Powder-coated white RAL 9010, gloss 70 Option: Painted in other standard RAL and BS colours 4

Illustration Hudevad P5 P5 single P5 single without convector, rear view P5 single with convector (P5K), rear view P5 double P5 double (P5D) without convector, rear view P5 double with convector (P5KD), rear view 5

Dimensions Hudevad P5 Height and length 1000 700 600 0 0 0 0-00 Depth and profile view P5 P5K P5D P5KD 58 105 123 6

Tapping distances Hudevad P5 Side tappings ABCD P5 single and double, front view H N A B C D N H Radiator height H, mm Centre distance N, mm 0 200 0 0 0 0 600 0 700 600 1000 900 Centre distance N is calculated as: Radiator height H - 100 mm Underside tappings EF/FE P5 single and double, front view G H E F NP L Centre distance P is calculated as: Radiator length L - 100 mm Underside tappings EE/FF P5 single and double, front view 2E EE FF 2F Note: Always connect flow to the outermost tapping. Where P5 radiator lengths exceed 10 mm, and same-end tappings are required (AB or CD), P5 is factory-fitted with a rear return tube to ensure optimum water flow. Forced water circulation does not change the standard tapping designations. 7

Build-in dimensions Hudevad P5 Profile view P5 /70 23 /43 10 / P5, H:1000 mm 53/73 26/46 10/ P5K 68 /88 43 /63 10 / 143 113 90 143 113 90 P5D P5D, H: 1000 mm P5KD 115/ 135 23/ 43 10/ 118/138 26/46 10/ 135/155 43 /63 10/ 143 113 90 242 212 189 143 113 90 242 212 189 8

Position of straps 100 B A L Rear view B A 100 If the no. of brackets is 3 or more and the no. of sections is uneven, the strap in the middle is displaced 17 mm towards tapping A. Note: B = 2 mm at flow/return side on radiators with built-in valve and with EE and FF tappings. Position of rails and no. of brackets Radiator length L, mm No. of sections No. of brackets / spacers / straps A, mm B, mm 0-0 12-15 2/2/1 - - 533-1800 21-2/2/2 L-366 183 1833-3800 51-74 3/3/3 (L-366)/2 183 3833-00 75-114 4/4/4 (L-366)/3 183 Note: Also applies to all adjustable brackets. P5 radiators shorter than 0 mm have one strap. Built-in valve Application Tappings Dimensions For use where a thermostatic valve is to be integrated within the radiator, where discreet pipework is required or for the ease of installation. On P5K the number of convector fins is reduced to accommodate the built-in valve, resulting in a total output loss of approx. - Watts depending on the height. The thermostatic sensor of the valve is passed through a hole in the front of the radiator (type1) or through the end of the radiator (type 3). Type 1 and 3 valve radiators have underside 1/2 tappings. Tapping combinations EE, FF or EF/FE can be ordered. Air vent opposite the valve can be ordered. UR-flex tappings are available for concealed pipework. Minimum radiator length for built-in valve is 15 sections. In terms of heat output, integrated valves take up 2 sections. Built-in valve Type 1 valves are supplied with spindle extenders for depths 105, 108 and 123. Type 3 valves are supplied with spindle extenders for all depths. Note: Spindle extender to be dismounted for presetting. P5 with built-in valve type 1 (front) and type 3 (side/end) 9

Built-in valve type 1 Tappings EE/FF Tappings EF/FE 2E E F 67 P Centre distance P is calculated as: Radiator length L - 100 mm Profile view P5 with built-in valve type 1 P5 with built-in valve type 1, H:1000 P5K with built-in valve type 1 /70 53/73 10/ 68/88 10/ 43/63 26/46 43/63 P5D with built-in valve type 1 115/135 P5D with built-in valve type 1, H:1000 118/138 10/ P5KD with built-in valve type 1 133/153 10/ 43/63 26/46 43/63 10

Built-in valve format 3 Tappings EE/FF Tappings EF/FE 2E E F P Centre distance P is calculated as: Radiator length - 100 mm Profile view P5 with built-in valve type 3 P5 with built-in valve type 3, H:1000 P5K with built-in valve type 3 70 73 70/90 10/ 43 46 43/63 P5D with built-in valve type 3 135 P5D with built-in valve type 3, H:1000 138 P5KD with built-in valve type 3 135/155 10/ 43 46 43 /63 11

UR-flex Description P5 with UR-flex embraces a simple, timeless design through a unique connection method that conceals all pipework. The radiators can be supplied for opposite end or same end tappings. Flexhoses made of high density armored medical silicone are included from the factory. Extremely easy to clean due to the flat front, convector tubes and concealed pipework. The tappings and the UR-flex hoses are concealed behind the extended front plate. Only the air vent and the built-in valve are visible on the front. Note: The standard version of P5 with UR-flex is fitted with closed ends. Please see sketches below. Advice, etc. Available for Wall distance Installation A return pipe is fitted, if same end tappings and lengths > 1200 mm are required. 0 mm high radiators can only be supplied with diagonal tappings. All models mm The UR-flex hoses (provided by Hudevad) are installed between the concealed radiator tappings and the wall outlets/pex sockets fitted by the SHAP installer. The radiator can then be mounted using the usual wall brackets. The UR-flex radiator types are also available without valves, to facilitate central valve location in an installations room, etc. P5 with UR-flex, built-in valve type 1, profile view P5 with UR-flex, built-in valve type 3, profile view P5 with UR-flex, no valve, profile view P5 with UR-flex, built-in valve type 4, profile view 12

Built-in valve type 1 Model references and dimensional sketches for wall outlet/pex socket location. 175 200 80 35 UR 1 175 200 UR 2 1 175 Built-in valve format 1, left, same end tappings, prepared for EE pipework. If same end tappings are required, the max. radiator length is 1200 mm. UR 3 175 200 35 80 Built-in valve format 1, left, diagonal tappings, prepared for EF pipework. UR 4 175 175 1 1 200 175 1 175 Built-in valve format 1, right, same end tappings, prepared for FF pipework. If same end tappings are required, the max. radiator length is 1200 mm. Built-in valve format 1, right, diagonal tappings, prepared for EF pipework. 13

Built-in valve type 3 Model references and dimensional sketches for wall outlet/pex socket location. 60 60 200 200 35 UR 5 UR 6 1 Built-in valve format 3, left, same end tappings, prepared for EE pipework. If same end tappings are required, the max. radiator length is 1200 mm. Built-in valve format 3, left, diagonal tappings,prepared for EF pipework. UR 7 35 UR 8 1 1 1 60 60 1 200 1 200 190 1 190 190 1 1 Built-in valve format 3, right, same end tappings,prepared for FF pipework. Built-in valve format 3, right, diagonal tappings,prepared for EF pipework. If same end tappings are required, the max. radiator length is 1200 mm. 14

No valve Model references and dimensional sketches for wall outlet/pex socket location. 200 35 UR 9 1 200 60 175 60 UR 10 No valve, same end tappings, prepared for EE pipework. If same end tappings are required, the max. radiator length is 1200 mm. No valve, diagonal tappings, prepared for EF pipework. UR 11 35 UR 12 1 175 175 200 1 60 175 200 60 60 1 60 No valve, same end tappings, prepared for FF pipework. If same end tappings are required, he max. radiator length is 1200 mm. No valve, diagonal tappings, prepared for EF pipework. 15

Built-in valve type 4 Model references and dimensional sketches for wall outlet/pex socket location. 200 35 12 0 235 UR 13 200 235 UR 14 0 1 Built-in valve format 4, left, same end tappings, prepared for EE pipework. If same end tappings are required, the max. radiator length is 1200 mm. UR 15 200 235 35 1 Built-in valve format 4, left, diagonal tappings, prepared for EF pipework. 12 0 UR 16 235 175 200 1 0 1 175 Built-in valve format 4, same end tappings, prepared for FF pipework. If same end tappings are required, the max. radiator length is 1200 mm. Built-in valve format 4, right, diagonal tappings, prepared for EF pipework. 16

Output Hudevad P5 P5 single P5 Height, mm W/metre 75 /65 /20 Output W/metre 55 /45 /20 W/metre 90 /70 /20 Water content litres/ metre Weight 0 317 165 1 0.8 9.0 kg/ metre 0 416 216 526 1.0 11. 6 0 514 267 649 1.3 14.2 600 611 318 772 1.5 16.8 700 707 368 893 1.7 19.4 1000 990 512 1253 2.5 26.7 P5K Height, mm W/metre 75 /65 /20 Output W/metre 55 /45 /20 W/metre 90 /70 /20 Water content litres/ metre Weight kg/ metre 0 413 216 521 0.8 11. 0 0 548 285 692 1.0 14.6 0 681 353 862 1.3 18.3 600 815 422 1031 1.5 22.0 700 949 488 12 02 1.7 25.6 1000 1345 685 1711 2.5 36.5 P5 double P5-D Height, mm W/metre 75 /65 /20 Output W/metre 55 /45 /20 W/metre 90 /70 /20 Water content litres/ metre Weight kg/ metre 0 5 278 684 1.7 18.0 0 706 363 895 2.1 23.2 0 868 447 110 0 2.5 28.4 600 1029 5 14 2.9 33.6 700 1188 612 1 6 3.4 38.7 1000 1656 848 2103 4.9 53.3 P5K-D Height, mm W/metre 75 /65 /20 Output W/metre 55 /45 /20 W/metre 90 /70 /20 Water content litres/ metre Weight kg/ metre 0 767 381 985 1.7 22.0 0 996 497 1276 2.1 29.2 0 1218 608 1561 2.5 36.6 600 1436 717 18 2.9 44.0 700 1651 829 2112 3.4 51.2 1000 2280 115 0 2 911 4.9 73.0 17

Options Hudevad P5 Angled radiators Description Output calculation Installation P5 and P5K radiators can be supplied angled. Tapping designations etc. follow the same principles as for straight radiators. Same as P5 and P5K (advisory calculation). Wall or floor mounted. External angle E Internal angle L1 V L1 L2 L2 V E Internal angle L1 L2 V E 18

Horizon infill and end panels Application Design Lengths Height Depth Used to connect several radiators installed in a line or as a dummy next to a radiator. Creates a continuous appearance where several radiators are connected. May also be used to cover pipework and electrical installations. Wall mounted. Can be dismounted for access to installations behind. Available as infill panels for installation between 2 radiators, as end panels for installation between radiator and wall, or to finish a string of radiators. Moreover end panels can be ordered with closed ends if used to finish a string of free, wall mounted radiators. Smooth, flat rebated front plate with solid top and bottom and pressed steel vertical waterways. With folded edge to conceal gap between radiator and Horizon infill or end panel. Mounted on wall brackets. Brackets with screws and dowels are included. Horizon infill panels: 200-20 mm in increments of 1 mm Horizon end panels: 200-20 mm in increments of 1 mm Same as radiator. Same as radiator. Optional extras Horizon end panels (can be ordered with closed ends to finish a string of free, wall mounted radiators), hole for valve, hole for socket, tamper proof fixing, angled infill and end panels. Horizon system, front view End panel Radiator Infill panel Radiator End panel Horizon system, top view Wall mounting - Horizon infill and end panels Min. distance above radiator Wall mounting - Horizon infill and end panels with brackets and spacers, with tamperproof fixing. Min. distance above radiator 25 Min. 133 75 Min. 19

Closed end, profile Closed end, profile Horizon infill panel with tamper proof fixing Accessories Brackets *Bracket BP10/ Adjustable spacer for bracket 35 9 35 76 23 57 Adjustable brackets *Optional wall distance: 10 or mm to rear of radiator UR-flex: Wall distance mm 20

Adjustable console feet PR Profile view P5 with PR feet P5 with PR feet, H: 1000 P5K with PR feet M M M K K K 3 3 P P P5D with PR feet P5D with PR feet, H: 1000 P5KD with PR feet M M K K 3 3 P P 3 P 3 P M K Distance K, M and P for foot plate Depth, mm K, mm M, mm P (low/high), mm 13 105-1 or 180-320 43 36 16 105-1 or 180-320 58 22 31 105-1 or 180-320 105 7 13 105-1 or 180-320 108 3 16 105-1 or 180-320 123-11 31 105-1 or 180-320 21

Radiator with 2 feet Radiator with 3 feet P P 160 L 320 160 0-1800 160 L 320/2 L 320/2 160 1833-00 * If the no. of feet is 3 and the no. of sections is uneven, the foot in the middle is displaced 17 mm towards tapping A. Note: Hudevad advises not to use feet for heights > 700 mm, measured from upper floor surface to upper edge of radiator, unless the radiator is additionally secured at the top. PR feet, low - for P5 single and double PR feet, high - for P5 single and double P = 105-1 mm P = 180-320 mm Hole dimensions: 20.5 x 35.4 mm 114 80 10 L x W: 124 x 103 mm L x W: 70 x mm 90 22

Console feet FH Console feet FH (optional extras for all depts and heights) Tappings 001 001 002 003 005 007 008 37 Built-in valve type 1 Built-in valve type 1 Built-in valve type 3 038 039 0 041 Built-in valve type 3 Built-in valve type 1 Built-in valve type 1 Built-in valve type 1 042 0 051 052 Built-in valve type 1 Built-in valve type 3 Built-in valve type 3 Built-in valve type 3 053 070 071 072 Built-in valve type 3 073 23

UR Flex tappings UR 9 UR 10 UR 11 UR 12 UR1 UR 2 UR 3 UR 4 UR 5 UR 6 UR 7 UR 8 UR 13 UR 14 UR 15 UR 16 24