T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Similar documents
Operating instructions

Operating Instructions

Operating instructions

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Installation and maintenance instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Operating instructions

Operating instructions

Operating instructions

Operating instructions

Operating instructions

User manual. Logano GC 124 II. Gas boiler

ir-range 8G /03.15 Changes reserved.

/2010 US/CA

Operating instructions Oil condensing boiler

GREENSTAR i JUNIOR USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

VIESMANN. Operating instructions VITODENS 100-W. for the system user

Read installation manual prior to installation of this appliance! Read user manual before putting this unit in operation!

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Greenstar 12i system / 24i system

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Greenstar 12i/24i System

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

WHE 2.24 / WHE 2.24 FF

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Installation and maintenance instructions

GREENSTAR HIGHFLOW 440/550CDi

Operating instructions

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

Operating instructions

Bosch 80% AFUE Gas Furnace BGS80 Model

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

Greenstar 24i junior / 28i junior

USER GUIDE VOGUE MAX SYSTEM

WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 24i Junior/28i Junior

USER'S INFORMATION MANUAL

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

User s Information Manual Models: 45, ,000 Btu/hr

USER'S INFORMATION MANUAL

Tankless Water Heater

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Universal Fire Tube Boiler Wall Mount Models

CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

BOSCH CONDENS 5000W ZSB18-2A

USER'S INFORMATION MANUAL

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER


GREENSTAR CDi CLASSIC REGULAR ErP

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

User s Information Manual

E-COMBI EVO E-SYSTEM EVO

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

USER S INFORMATION MANUAL

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

USER'S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS FOR FLUE KIT

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

ecotec plus boiler user guide

USER'S INFORMATION MANUAL

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

GB162 Concentric Horizontal Vent Kit

24CDi, 28CDi & 35CDi II COMBI

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

TO DO IF YOU SMELL GAS

User s Information Manual

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

User s Information Manual

USER'S INFORMATION MANUAL

Mikrofill Ethos Condensing combination boiler

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

CRU-S Series Stainless Steel Condensate Recovery Unit

Residential Gas Hybrid Water Heater

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

GREENSTAR Ri ErP + User instructions UK/IE. Wall hung RSF gas fired condensing regular appliance. For central heating systems

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Connecting cable. Installation instructions (2018/04) US

Transcription:

6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G

2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols 3 2 Information about the Product 4 2.1 Product overview 4 2.2 EU Declaration of Conformity 4 2.3 Correct use 4 3 Regulations 5 3.1 oiler room 5 3.2 Quality of heating water 5 3.3 Correct fuel 6 3.4 Maintenance interval 6 4 Commissioning and operation 7 4.1 efore switching on 7 4.2 Checking the operating pressure 7 4.2.1 When should you check the operating pressure? 7 4.2.2 Checking the operating pressure (sealed systems) 7 4.2.3 Checking the fill level (open system) 8 4.2.4 Filling the heating system 8 4.3 Starting the heating system via the control panel 9 5 Shutting down the boiler 10 5.1 Shutting down the heating system 10 5.2 Shutting down the heating system because of a risk of frost 10 5.3 Emergency measures 10 6 Faults 11

Safety information and explanation of symbols 3 1 Safety information and explanation of symbols 1.1 For your safety Installation and operation Installation and commissioning must only be carried out by qualified installation engineers. Observe all instructions to ensure correct operation. Only use the boiler for its intended purpose. Maintenance Customers are advised to sign an inspection/ maintenance contract with an authorised contractor and to have the heating system serviced annually. The operator is responsible for ensuring that the heating system is safe and environmentally compliant (legislation on emissions or requirements applicable in respective country). Read and observe the safety information and codes of conduct: If you can smell gas, there is a risk of an explosion Close the gas shut-off valve. Open window(s). Do not operate electrical switches and mobile phones. Extinguish all naked flames. From outside the building: call gas supplier, authorised installer and emergency services. If you can smell flue gases, there is a risk of poisoning Switch off the heating system (page 10). Open windows and doors. Inform an authorised installer or gas supplier. Risk of poisoning due to insufficient ventilation during open flue operation Do not cover or reduce the size of ventilation openings in doors, windows and walls. If you do, the heating system must not be operated. Risk of fire from explosive and inflammable materials Inflammable materials or liquids (paper, thinners, paints, etc.) must not be used or stored in the boiler room. Warning: frost The heating system can freeze up in very cold weather if it has been switched off: Leave the heating system switched on all the time. If there is a fault: Reset the fault immediately or call an installer. Caution: system damage Keep the combustion air free from aggressive substances (halogenated hydrocarbons, for example, contained in spray cans, solvents or cleaning agents, paints and adhesives). This prevents corrosion. Prevent heavy contamination of the combustion air by dust, airborne seed, etc. Do not hang up any washing to dry in the boiler room. Caution: environmental damage from oil leaks If using oil as a fuel: Arrange immediately for an installer to investigate and rectify the cause of any oil leaks. 1.2 Explanation of symbols Safety information throughout the document is signalled by a warning triangle contained within a frame. Signal terms indicate the seriousness of the ensuing risk if measures for minimising damage are not taken. Caution means that slight material damage may occur. Warning means that minor injury or severe material damage may occur. Danger means that severe injury may occur. Very serious cases may result in death Notes are identified in the text by this symbol. They are bounded by horizontal lines above and below the text. Notes are included with important information for situations in which there is no danger for persons or equipment.

4 Information about the Product 2 Information about the Product 2.1 Product overview This boiler is a low temperature boiler that complies with DIN EN 303 for oil or gas combustion with modulating boiler water temperature control and no minimum return temperature. The main components of the are: The boiler block transfers the heat generated by the burner to the heating water. The boiler shell and insulation prevent energy loss. The control panel monitors and controls all electrical boiler components. 1 2 3 4 4 6 720 648 663-04.1T Fig. 1 boiler 1 Control unit 2 boiler block 3 Thermal insulation 4 oiler shell (casing) 2.2 EU Declaration of Conformity This product conforms in design and operation to the European Directives and the supplementary national requirements. Its conformity is confirmed by the CE designation. You can call up the Declaration of Conformity for this product on the internet or request a copy from your local osch sales office. 2.3 Correct use The boiler is intended for generating heating water. You may use any type-tested oil or gas fired burners to EN 267 or EN 676 provided their operating range meets the boiler specification. Using the boiler for any other purpose will be considered improper use. osch accepts no liability for any damage resulting as a consequence of such use.

Regulations 5 3 Regulations 3.1 oiler room Caution: oiler damage Through contaminated combustion air. Never use chlorinated cleaning agents or halogenated hydrocarbons (as, for example, contained in spray cans, solvents or cleaning agents, paints adhesives and thinners). Prevent heavy build ups of dust. Caution: System damage through water. In case of an acute risk of flooding, disconnect the boiler from its power supply and shut off the fuel supply before water enters the boiler room. After a flood, have the heating system checked by a installer before recommissioning. Ask your installer to replace any valves and control/regulating equipment that have come into contact with water. Caution: System damage through corrosion or scale formation as the result of using fill and top-up water that does not conform to the system-specific requirements. Ask your installer or water company for details of the Ca(HCO 3 ) 2 concentration (calcium hydrogen carbonate) in your supply area. The fill and top-up water will have to be treated if it does not meet systemspecific requirements. Consult your installer if this is the case. Your installer will enter the fill water level and quality in the operator's log book, which is maintained by the installer and included in the technical documentation. 3.2 Quality of heating water Water is used as the heat transfer medium in your heating system. Water is given a different term depending on its function in the system. Heating water: Water contained within your heating system. Fill water: Water used for the first filling of your system before commissioning. Top-up water: Water used to top-up your system in the event of water loss. All water contains substances, e.g. Ca (HCO 3 ) 2 (calcium hydrogencarbonate) that could affect the operation of your heating system. These can cause corrosion, scale formation or deposits. We recommend that you regularly monitor the quality of the fill and top-up water and treat it accordingly as and when necessary to ensure correct operation of the product.

6 Regulations 3.3 Correct fuel This heating system requires fuel of the correct type and grade to ensure its correct operation. Caution: System damage through unsuitable fuels. Use the specified fuel only. Follow the advice of your installer if you want to convert your heating system to another type of fuel or use fuel with a different specification. Your installer will enter in Table 2 (below) which fuel is used in your heating system. System Suitable fuels EL heating oil (to DIN 51603) for Austria: L heating oil ("Schwechat 2000" light oil) 1) Natural gas, LPG Type: Fuel used Date/ signature Tab. 1 Suitable fuels and fuel used 3.4 Maintenance interval Heating systems should be regularly maintained for the following reasons: to achieve a high level of efficiency and to operate the system economically (low fuel consumption), to achieve a high level of operational reliability, to maintain the cleanest possible combustion. Caution: System damage through a lack of, or unsatisfactory, cleaning and maintenance. Have your heating system inspected, cleaned and maintained by your installer once a year for gas and 2 for oil 1. We recommend you sign a contract covering an annual inspection and maintenance on an as-required basis. 1. If L heating oil ("Schwechat 2000" light oil) is being used, cleaning and maintenance must be carried out twice a year.

Commissioning and operation 7 4 Commissioning and operation 4.1 efore switching on efore switching on, ensure that the operating pressure and fill level are correct, the fuel supply is open and the heating system emergency stop switch is switched ON. 4.2 Checking the operating pressure 4.2.1 When should you check the operating pressure? Recently topped-up heating water loses much of its volume in the first few days because it releases gases. This causes air pockets, and the heating system will start to make a noise. After installing a new heating system, check the operating pressure daily for the first few days. If necessary top up with heating water and bleed the radiators. After a while the operating pressure will only need to be checked monthly. If necessary top up with heating water and bleed the radiators. 4.2.2 Checking the operating pressure (sealed systems) The registered installer will have set the red needle on the pressure gauge to the required operating pressure (at least 1 bar overpressure). Check that the pressure gauge needle is within the green field. Top up with heating water if the pressure gauge needle is below the green field. 1 2 3 6 720 615 362-42.2O Fig. 2 Pressure gauge for sealed systems 1 Red needle 2 Pressure gauge needle 3 Green field

8 Commissioning and operation 4.2.3 Checking the fill level (open system) The installer has set the needle on the pressure gauge to the required level. Check that the pressure gauge needle is within the red field. Top up with heating water if the pressure gauge needle is below the red field. 1 2 3 6304 4901-04.0K 6 720 615 362-42.2O Fig. 3 Pressure gauge for open systems 1 Greenneedle 2 Pressure gauge needle 3 Red field 4.2.4 Filling the heating system Filling and refilling of the heating circuit must been carried out by a method that has been approved by the Water Regulation Advisory Scheme (WRAS), for the type of heating appliances, i.e. Domestic (in-house) Fluid Category 3. Non-Domestic (other than in-house) Fluid Category 4. Depending on the Fluid Category the approved method should comprise of the following: 1. Requirements Fluid Category 3 systems (fig see right) Control valve (stop valve) including a double check valve on the mains cold water supply pipe Fig. 4 Requirements Fluid Category 3 systems Temporary connection to e removed after filling (filling loop) Control valve (stop valve) on the heating system pipework 2. Requirements Fluid Category 4 systems (fig see right) Control valve (stop valve) on the mains cold water supply pipe Strainer Verifiable ackflow Prevention Device with reduced pressure Zone(RPZ valve assembly) incorporating a Type A air gap Tundish Control valve (stop valve) on the heating system pipework Fig. 5 Requirements Fluid Category 4 systems

Commissioning and operation 9 4.3 Starting the heating system via the control panel Switch the boiler water thermostat to "AUT". Switch the ON/OFF switch on (position "I"). The entire heating system is switched ON. Check/adjust the following settings on the control panel: Automatic operating mode Required room temperature Required DHW temperature when required Required heating program when required Operating information can be found in the control panel documentation. Fig. 6 Switching on the heating system 1 oiler water thermostat 2 ON/OFF switch

10 Shutting down the boiler 5 Shutting down the boiler 5.1 Shutting down the heating system Switch the ON/OFF switch on the control panel OFF (position "0"). This switches the boiler and all its components OFF (for example the burner). Close the main fuel shut-off valve. Caution: System damage caused by frost The heating system can freeze up in very cold weather if it has been switched off. Leave the heating system switched on all the time. Drain the heating system and DHW pipework at the lowest possible point to protect the heating system against freezing whilst it is switched off. Fig. 7 Switching off the heating system 1 ON/OFF switch 5.2 Shutting down the heating system because of a risk of frost If you need to shut down the heating system for a lengthy period, during which frost might occur, the heating system must be drained. Switch the ON/OFF switch on the control panel OFF (position "0"). This switches the boiler and all its components OFF (for example the burner). Close the main fuel shut-off valve. Drain the heating system and DHW pipework at the lowest point. The automatic air vent at the highest point of the heating system or the air vent valve on the highest radiator must be open during draining. 5.3 Emergency measures In the event of an emergency, e.g. a fire, proceed as follows: Never risk your own life. Your own safety is paramount. Close the main fuel shut-off valve. Isolate the heating system from the mains power supply using the heating system emergency stop switch or the corresponding domestic fuse. Contact the emergency services

Faults 11 6 Faults Faults in the heating system are displayed on the control panel display. For further information on the fault displays please refer to the service instructions of the control panel concerned. Caution: System damage caused by frost The heating system can freeze up in very cold weather if it has been switched OFF through a fault shutdown. Rectify the fault immediately and restart the heating system. If this is not possible: Drain the heating system and DHW pipework at the lowest point. urner faults A burner fault is also indicated by the fault lamp on the burner. Caution: System damage Repeated pressing of the reset button can damage the ignition transformer on the burner. Do not press the reset button more than three times in a row (for oil urners only). If the fault does not reset after the third attempt: Try to identify the fault using the burner documentation. Contact an installer if necessary. To reset burner faults: Press burner reset button.

United Kingdom osch Thermotechnology Cotswold Way, Warndon, Worcester WR4 9SW All Enquiries: 0844 892 3004 http://www.boschthermotechnology.co.uk/ Australia Robert osch (Australia) Pty Ltd 1555 Centre Rd Clayton, VIC 3168 Phone 1300 30 70 37 Fax 1300 30 70 38 www.bosch.com.au/hotwater New Zealand Phone 0800 4 osch or 08 543 352 www.bosch.co.nz