Duct Cable GYTS-144B1.3

Similar documents
Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

HELKAMA. Optical Fibre Cables

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Ø 1000 * 588 mm 50 kg

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Fibre Specification Standards

Special Provision No. 683S28 December 2017

DNVGL-CP-0402 Edition February 2016

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Fiber Optic Distribution Cables (6-144 Fibers)

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

SPECIAL ELECTRICAL AND OPTICAL CABLES

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Fiber Optic Patch Cord and Pigtails

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

This document is a preview generated by EVS

MT-RJ Optical Fiber System Field Testing

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Fibre Optic Cable. Catalogue.

industry solutions: military

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Draft ES V1.1.1 ( )

Flame Retardant Overall Screened Instrumentation Cables (multicore)

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Fibre Optic Basics FIA Summer Seminar 2014

Field Test Procedure for Optical Fibre Link Measurements

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

ETSI TS V1.2.1 ( )

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Product Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes

Catalogue Telecommunication Cables INTRODUCCIÓN

Caledonian Flame Retardant Coaxial Cables

ITU-T L.404. Field mountable single-mode optical fibre connectors

ETSI TS V1.2.1 ( )

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LC Duplex Adapter For LC Cutouts

SPECIFICATIONS - DETAILED PROVISIONS Section Fiber Optic Cabling and Components C O N T E N T S

Jan07 Rev B

WG Buried Fibre Cable Long Perimeter Detection System

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Dome Fiber Optic Closure SC-221

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

SECTION ELECTRICAL IDENTIFICATION

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Broadband System - H

Main features of the JETnet system

Tratos Railway Cables

Fibre optic media options and trends

STANDARD CONFORMANCE

Telecommunication Cables

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

/Oct/2014 Rev B

DNVGL-CP-0401 Edition February 2016

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

/Oct/2014 Rev E

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Photovoltaic Cables EN H1Z2Z2-K

INTERNATIONAL STANDARD

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Product Specification Qualification Test Report

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

ENHANCED FIRE PERFORMANCE CABLE

Apr06 Rev A

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

Clearlite Photonic Fibers

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

OPTICAL FIBER SOLUTIONS

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

Transcription:

Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved

1. Scope This Specification covers the design requirements and performance standard for the supply of optical fibre cable in the industry. XCOM ensures a stable quality control system for our cable products through several programs including ISO 9001, ISO 14001 and OHS. Cable type Application GYTS-144B1.3 Duct installation 1.1 Cable Description Optical fibres are housed in loose tubes that are made of high-modulus plastic and filled with waterproof compounds. Steel wire is applied as central strength member. Loose tubes are SZ stranded around the central strength member. The cable gel are used in and over the cable core to prevent it from water ingress. Corrugated steel tape and polyethylene sheath are applied as outer sheath. 1.2 Reference The cable offered by XCOM are designed, manufactured and tested according to the standards as follows: ITU-T G.652D Characteristics of a single-mode optical fibre IEC 60794-1-1 IEC 60794-1-2 IEC 60794-3 IEC 60794-3-10 IEC 60794-3-11 Optical fibre cables-part 1-1: Generic specification-general Optical fibre cables-part 1-2: Generic specification-basic optical cable test procedure Optical fibre cables-part 3: Sectional specification-outdoor cables Optical fibre cables-part 3-10: Outdoor cables-family specification for duct and direct buried optical communication cables Optical fibre cables-part 3-11: Outdoor cables-detailed specification for duct and directly buried single-mode optical fibre telecommunication cables 1.3 Life Time Optical fibre cables supplied in compliance with this specifications is capable to withstand the typical service condition for a period of twenty-five (25) years without detriment to the operation characteristics of the cable.

2. Optical Fibre Optical Fibres supplied in this specification meet the requirements of ITU-T G652D Parameters Specification MFD(1310nm) 9.2+/-0.4um MFD(1550nm) 10.4+/-0.5um Cladding diameter 125µm±1.0µm Fiber diameter 245+/-7um, with UV coating, and colored to : 250+/-15um Core/cladding concentricity error 0.6um Coating/cladding concentricity error 12.0um Cladding non circularity 1.0% Cut off wavelength λcc 1260nm Attenuation coefficient 1310nm: 0.36dB/km max after cabling 1550nm: 0.22dB/km max after cabling Bending-loss performance of optical fiber @1310nm&1550nm 0.05dB (100 turns around a mandrel of 50mm diameter) Polarization mode dispersion link value 0.1ps/ km Zero-dispersion wavelength 1312+/-12nm Zero-dispersion slope 0.091ps/nm 2.km 3. Optical Cable 3.1 Technical Characteristics The unique second coating and stranding technology provide the fibres with enough space and bending endurance, which ensure good optical property of the fibres in the cable Accurate process control ensures good mechanical and temperature performance High quality raw material guarantees the long service life of cable 3.2 Cross Section of Cable

GYTS-144B1.3 3.3 Fibre and Loose Tube Identification The color code of fibres and loose tubes will be identification in accordance with the following color sequence, other sequence is also available. Color Code 1 2 3 4 5 6 Blue Orange Green Brown Grey White 7 8 9 10 11 12 Red Black Yellow Violet Pink Aqua 3.4 Dimensions and Descriptions The standard structure of GYTS cable is shown in the following table, other structure and fibre count are also available according to customer requirements. Item contents Value 144 Loose tube number 12 Outer diameter (mm) 2.0 Filler number 0 Max. fiber counts per tube G.652D 12 Central strength material Steel wire member diameter (mm) 2.0

PE layer diameter (mm) 5.8 Water Blocking Material Material Cable filling gel Armor Material Steel tape Material MDPE Color Black sheath Thickness Nominal: 1.8 (mm) Cable diameter(mm) Approx. 14.6 Cable weight(kg/km) Approx. 220 3.5 Main Mechanical and Environmental Performance Item Value 144 Tensile performance(n) 1500 Crush(N/100mm) 1000 Operation temperature: -40 ~+60 Installation temperature -20 ~+50 Storage temperature -40 ~+70

4. Mechanical, Physical and Environmental Test Characteristics The mechanical and environmental performance of the cable are in accordance with the following table. Unless otherwise specified, all attenuation measurements required in this section shall be performed at 1550nm. Items Test Method Requirements Tension Crush Impact Bend Repeated bending Torsion Water Penetration Temperature cycling Other parameters IEC 60794-1-2-E1 Load: According to 3.5 Sample length: Not less than 50m. Duration time: 1min. IEC 60794-1-2-E3 Load: According to 3.5 Duration of load: 1min IEC 60794-1-2-E4 Radius: 300 mm Impact energy: 10 J Impact number: 1 Impact points: 3 IEC 60794-1-2-E11A Mandrel radius: 10*D Turns:4 Cycles:3 IEC 60794-1-2-E6 Bending radius: 20*D Cycles: 25 Load: 150N IEC 60794-1-2-E7 Cycles:10 Length under test: 1m Turns: ± 180 Load: 150N IEC 60794-1-2-F5B Time : 24 hours Sample length : 3m Water height : 1m IEC 60794-1-2-F1 Sample length: at least 1000m Temperature range: -40 ~+70 Cycles: 2 Temperature cycling test dwell time: 12 hours According to IEC 60794-1 after test after test No water leakage. The change in attenuation coefficient shall be less than 0.1 db/km.

5. Packaging and Drum 5.1 Cable Sheath Marking Unless otherwise specified, the cable sheath marking shall be as follows: Color: white Contents: XCOM, the year of manufacture, the type of cable, cable number, length marking Interval: 1±0.2% m Outer sheath marking legend can be changed according to user s requests. 5.2 Reel Length Standard reel length: 2/3 km/reel, other length is also available. 5.3 Cable Drum The cables are packed in fumigated wooden drums. 5.4 Cable Packing Both ends of the cable will be sealed with suitable plastic caps to prevent the entry of moisture during shipping, handling and storage. The inner end is available for testing.