Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

Similar documents
Installation plan. Washer disinfector. en AU, NZ PG 8583 CD. M. Nr

Installationsplan / Installation plan PG 8059

Installationsplan / Installation plan PG 8056

Installation plan: PG Mat. no Version 00 US

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation plan PG 8581 PG 8582 PG en - US

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installationsplan / Installation plan PW 6161 EL

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Installation plan Commercial Washing Machine PW 413 PW 418

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

Tumble dryer PT 5136 PT en - GB. Installation plan

Installation Plan Washing Machine PW 811 PW 814 PW 818

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 04

Installation plan Heat pump dryer PT 8203 SL WP

for relative humidity and temperature

for relative humidity and temperature

Installation manual Washer extractor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Product data sheet AIRWIN additional modules Accessories AIRWIN

Combisteamer (electric)

Plant growth chambers

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

INSTALLATION INSTRUCTIONS

KMF Environmental test chamber for constant climate

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

VADA - Rain2Main Automatic Rainwater Controller

INSTALLATION GUIDE NZ AU D

INSTALLATION AND INITIAL OPERATING INSTRUCTIONS

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Technical information for installation and operation

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

1. Description. 2. List of Accessories included

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

Marco Beverage Systems Ltd.

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501

VERSAFLOW VORTEX Supplementary instructions

Getinge 8666/8668 Washer Disinfectors

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Data Sheet. >>AMTAX inter 2

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

Kitchen Water Dispenser

Installation and instruction manual SOLAR STATION

Model KBF 240 Constant climate chambers with large temperature / humidity range

Your Health, our Technology AWD655. Instrument Washer Disinfector

DEKO 260 Washer - Disinfector - Dryer

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

LOGIC CONTROLLED DEKO 25 EASE OF USE

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Constant climate chambers

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Retrofit an evacuated tube collector to an existing cylinder Updated

Mix Boiler & Font Range ( #, #, #, , )

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Mains Power Filter 970MF10 970MF20. Installation Instructions

Room Temperature Sensors

Model KBWF 240 Growth chambers with light and humidity

For the heating engineer. Installation manual. Interface 0-10V VR34

Infrared Flame Detectors

Closomat Lima Vita installation & user guide

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Autofill Wall Mount Boilers

Infrared Flame Detectors

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

aquaconcept Cold water

SCHWAN INSTALLATION GUIDE

Constant climate chambers

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

PG 8535 Perfect Reprocessing

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Operating instructions Washer-disinfector for laboratory glassware and laboratory utensils PG 8583

MIX Boiler & Font Range Service Manual

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Drying Cabinet Installation and Operating Manual

FLOW HEATER 32E X 2R IMPORTANT GENERAL INFORMATION: SPECIFICATION. Instruction Manual. Article number: 045a-105 Electric heating capacity:

Installation, Operating and Servicing Instructions

INSTALLATION MANUAL. FlexFuison PLATINUM ELECTRIC COMBI FPE-615 FPE-621 FPE-115 FPE-121 FPE-215 FPE-221

Constant climate chambers

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Winterhalter UC Energy Series

Your Health, our Technology AWD655. Instruments Washer Disinfector

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Technical data LA 60TU

INSTALLATION GUIDE NZ AU C

G 7804 Lavabor. Ideal for a wide variety of glassware types and applications

G 7824, G 7825, G Miele Professional Medium Capacity Washer-Disinfectors for Medical Device Reprocessing from SiC

Zenith HydroTap. Filtered Chilled drinking water for residential kitchens and tea rooms. Affix Model Number Label Here NZ

Environmental simulation chamber for complex alternating climate profiles

Copper convection heaters:

Transcription:

Installation plan: PG 8581 PG 8583 Mat. no. 10 390 400 Version 02 GB, IE, AU, NZ

Technical data sheet Washer-disinfector PG 8581-8583 Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection optional or required, depending on model GB, IE GB, IE GB, IE AU, NZ AU, NZ AU, NZ Voltage (standard version) V/Hz AC 230 V/50 Connected load kw 6.3 Fuse rating A 1 x 30-32 Connection cable, min. cross-sectional area mm² 3 x 4 Voltage (convertible) V/Hz 3N AC 400/50 Connected load kw 9.3 Fuse rating A 3 15/16 Connection cable, min. cross-sectional area mm² 4 2.5 Voltage (convertible) V/Hz AC 230 V/50 Connected load kw 3.3 Fuse rating A 1 x 15 /16 Connection cable, min. cross-sectional area mm² 3 x 1.5 Voltage (standard version) V/Hz 3N AC 400/50 Connected load kw 9.3 Fuse rating A 3 15/16 Connection cable, min. cross-sectional area mm² 4 2.5 Voltage (convertible) V/Hz AC 230 V/50 Connected load kw 6.3 Fuse rating A 1 x 30-32 Connection cable, min. cross-sectional area mm² 3 x 4 Voltage (convertible) V/Hz AC 230 V/50 Connected load kw 3.3 Fuse rating A 1 x 15 /16 Connection cable, min. cross-sectional area mm² 3 x 1.5 We recommend connecting the washer-disinfector to the electrical supply via a plug and socket so that electrical safety checks, can be carried out easily. The plug and socket must be easily accessible after installation. A hard wired is possible. It must be made in accordance with local and national safety regulations: - IEE (IET) Wiring regulations BS 7671: 2008 (for GB and IE) - Australian / New Zealand Wiring Rules AS/NZS 3000 Splash protection class IP21 Installation plan PG 8581 PG 8583 M.-Nr. 10 390 400 / 02 Date created: 11.03.2016 Page 2 / 4

Equipotential bonding and protective earth conductor There is a screw point at the back of the washer-disinfector, to which equipotential bonding can be connected if required. Connect equipotential bonding and protective earth conductor! External dispensing (optional) (note machine model) Network/ printer (optional) Connection for up to two dispensing units for liquid agents on the back panel. Optional machine interface for transmission or process data output Communication module (not supplied) Ethernet module or RS232 module (install electrical sockets near machine if required) Connections/installation must comply with: - IEC 60950 - AS/NZS 60950 (for AU and NZ) Cold water Hot water (PG 8581 note machine version) Two cold water s are required for models with a steam condenser (DK). The second cold water hose can be connected using the Y-piece provided. Maximum temperature C 20 Max. water hardness mmol/l dh 12.6 70 Minimum flow pressure kpa 200 Minimum flow pressure with extended water intake kpa 100 Maximum pressure kpa 1,000 Flow rate l/min 7.5 On-site threaded union in accordance with (flat seal): - DIN 44991 - AS 3688 (for AU and NZ) Inch 3/4" male thread Length of cold water inlet hose m Approx. 1.7 Length of steam condenser hose m Approx. 1.7 Connection to a drinking water supply in the UK requires the installation of an additional WRAS approved non-return device. For Australia and New Zealand: This machine must be connected to the potable water supply via the non-return valve (dual check valve) supplied with the machine. Maximum temperature C 65 Max. water hardness mmol/l dh 12.6 70 Minimum flow pressure kpa 200 Minimum flow pressure with extended water intake kpa 40 Maximum pressure kpa 1,000 Flow rate l/min 7.5 On-site threaded union in accordance with (flat seal): - DIN 44991 - AS 3688 (for AU and NZ) Inch 3/4" male thread Length of hot water inlet hose m Approx. 1.7 Connection to a drinking water supply in the UK requires the installation of an additional WRAS approved non-return device. For Australia and New Zealand: This machine must be connected to the potable water supply via the non-return valve (dual check valve) supplied with the machine. Installation plan PG 8581 PG 8583 M.-Nr. 10 390 400 / 02 Date created: 11.03.2016 Page 3 / 4

Demineralised water (PG 8581 note machine version) Maximum temperature C 65 Minimum flow pressure (AD pressure resistant) kpa 200 Minimum flow pressure with extended water intake kpa 30 Maximum pressure (AD pressure resistant) kpa 1,000 Flow rate l/min 7.5 On-site threaded union in accordance with (flat seal): - DIN 44991 - AS 3688 (for AU and NZ) Inch 3/4" male thread Length of demin. water inlet hose m Approx. 1.7 For Great Britain and Ireland: Connection to a drinking water supply requires the installation of an additional WRAS approved non-return device. For Australia and New Zealand: The demineralised water supply system must meet local and national regulations and include a backflow prevention device at first point on entry when connected to potable water. PG 8583 only: Model with feed pump for unpressurised demineralised water (ADP) Minimum flow pressure (AD unpressurised) kpa 8.5 Maximum pressure (AD unpressurised) kpa 60 Machine nipple (outer dia. x l) mm 6 x 30 Hose from supply container to machine to be fitted on site Waste water Drainage temperature C 93 Length of drain hose m Approx. 1.4 Max. drain hose extension m Approx. 4.0 Max. drain pump head height from base of machine m 1.0 Max. transient flow rate l/min 16 On-site sleeve for drain hose (dia. x length) mm 22 x 30 It is advisable to lay the drain hose in a curve min. 600 mm above floor level to the drainage point. Machine feet Height-adjustable mm -0/+60 Machine foot diameter mm 35 Machine foot socket M 8 Heat dissipation rate to installation site Heat dissipation through heat radiation kwh/h 0.35 Load heat dissipation on removal kwh/h 0.40 Machine data Undercounter height mm 820 Height incl. lid mm 835 Width mm 598 Depth mm 598 Door height mm 622 Net weight kg 74 Floor load in operation N 1,200 Min. access width, incl. transport pallet mm 670 Min. access depth incl. transport pallet mm 740 Min. access height, incl. transport pallet mm 920 Installation conditions Permissible ambient temperature C 5-40 Maximum relative humidity % 80 Max. installation above sea level m 1,500 It is essential to observe the installation instructions when installing the washer-disinfector. In order to reduce the risk of steam damage, the area around the washer-disinfector should be limited to furniture and fittings that are designed for use in commercial environments. Installation should only be performed by qualified fitters in accordance with valid regulations, relevant standards and health and safety codes! All rights reserved! Measurements in mm Installation plan PG 8581 PG 8583 M.-Nr. 10 390 400 / 02 Date created: 11.03.2016 Page 4 / 4