Water Mist in Care Homes & Hospitals in the Nordic Territory. Henrik Johansson

Similar documents
Additional Requirements for Watermist Systems Protecting High-rise Buildings

Case study: EconAqua water mist sprinkler system

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Water Mist Fire Suppression

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

Fire protection for buildings

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Approval of water mist systems in buildings

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Sprinkler System Installer Level 2

Watermist Applications and Approvals

PLAN REVIEW CHECKLIST

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Protecting Backup Generators and UPS Systems Against Risk of Fire

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

Report on First Revision November 2013 NFPA 750

WATER MIST CONVENTION AND EXHIBITION

Sprinklers in Europe known problems and misconceptions. Alan Brinson

Sprinkler Permit Applications

European Sprinkler Campaigns. Edinburgh, 20 January 2010 Alan Brinson

VELMIST. System Mgły Wodnej Niskociśnieniowej

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Appendix A: US Fire Statistics Tables

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

HIGH PRESSURE WATER MIST SYSTEM Application: High Rise Building Bindreiter Michael London,

MORE THAN JUST FIRE PROTECTION

Fire Protection Systems Operation and Maintenance 3 PDH / 3 CE Hours

Installation and Maintenance Requirements

The Science Behind Water Mist Protection of Typical Building Hazards

Aircraft Hangars DESCRIPTION. A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

Moving Target: A Case Study in Providing Fire Protection Below a Reconfigurable Concert Hall Seating System. Part 1: Concept Design

The Energy Mist System

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

Update on European Standardization Work

Fire Protection in High-rise Buildings

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Fire Curtains and Radiation Attenuation

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

and Sprinkler System in Resalat Tunnel of Tehran

Fire Protection Coffee Break Training August 2016

Performance Based Fire Protection With Water Mist

Fire fighting with fast deployment units. CRISTANINI Spa Via Porton 5, Rivoli Veronese, ITALY

Fire fighting excellence. HI-FOG water mist fire protection

Water Mist v Sprinklers

Compliance w/ the 2012 Life Safety Code

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Fire fighting excellence. HI-FOG water mist fire protection

Agency for Health Care Administration

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Large Family Daycare Guideline

Center for Life Safety Education

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

An Overview of Extinguishing Systems for Computer Equipment

Minifog EconAqua Water mist sprinkler systems

Aircraft Hangers. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Nessie High Pressure Water Mist Components for Fire Fighting

Association of Irish Risk Management An Introduction to Sprinklers 12th September 2012

CHAPTER 7 ALTERATIONS LEVEL

Material Design for Central Chutes

What is HI-FOG? The natural enemy of fire

Report on First Revisions with Statement June 2014 NFPA 101

Watermist Fire Protection of Plant Rooms

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Residential Based Care Facility Guidelines

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Fire fighting excellence. HI-FOG water mist fire protection

Fire fighting excellence. HI-FOG water mist fire protection

Agency for Health Care Administration

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

Florida Building Code 2010

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

For additional information regarding R-3.1 residential care facilities please contact (951)

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

FOREFRONT AT THE OF PROTECTION

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Residential Care Facilities Requirements

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Fixed fire protection solutions

Established /10/2015. Doran Pruisner Dan Wood

6 th Pipeline Technology Conference 2011

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

Transcription:

Water Mist in Care Homes & Hospitals in the Nordic Territory Henrik Johansson

AquaMist AquaSonic Twin Fluid Technology 7 Bar Atomizer: a Super Sonic Generator creating droplets 20 50 times smaller than conventional systems and with 70 % lower water consumption than a HP Water Mist Special Hazard Applications, FM approved 2

AquaMist AquaFog High Pressure Water Mist Systems 50-70 bar Open and closed head nozzles Special Hazard applications, FM approval 3

AquaMist ULF Low Pressure Water Mist System 7 16 bar Standard sprinkler components, except for the nozzles FM/NFPA LH, EN-12845 OH 1, Residential 4

Care Homes & Hospitals Hospital - normally OH 1 Care Homes - INSTA 900-1 and OH 1 Adapted Housing for Disabled People - Insta 900-1 and OH 1 Legislations drives the installation of Automatic Extinguishing systems in above applications New group of customers New demand and requirements Fear of water, little experience and lack of knowledge influence the decisions and choice of solution 5

Solutions Types of Automatic Extinguishing Solutions and when they can be installed: Standard Sprinkler - Always Residential Sprinkler - When the type of occupancy allows Easily mountable automatic extinguishing systems For use in single family dwellings and apartments with high risk people - not standards are applicable Water mist When the specification or AHJ allows the system as an equivalent to Standard Sprinklers 6

Cost, Benefit & Value Total cost System, Installation, Maintenace Codes & Standards Performance Density, Duration, Pressure, Coverage Customer Benefit

Standard Sprinkler Standard Sprinkler (CEN 12845) OH 1; 5 mm/min/m 2 Advantages: Robust and proven technology Various of design options Easy to combine with other Hazard Classifications Low cost solution - when water reservoir is not needed Low pressure Low maintenance cost Disadvantages: High water demand and flux density 8 Higher cost when water reservoir is needed

Residential Sprinkler Residential Sprinkler (INSTA 900-1) Building Type 1: 2.04 mm ; 1-2 spk; 10 min duration One and two family dwellings Row houses having three levels above ground including the attic, and one basement level; or Residential buildings with not more than 4 dwelling units up to a maximum of three stories in height and one basement level Building Type 2: 2.04 mm ; 1-4 Spk; 30 min duration Buildings arranged as residential occupancies up to a maximum of four stories in height and one basement level, excluding any building arranged to permanently house people who need assistance exiting the building Building Type 3: 4 mm; 4 Spk; 30 min duration Buildings, or parts of buildings, arranged to house people who need assistance exiting the building Buildings of 5 stories in height or more, arranged as residential occupancies. 9

Residential Sprinkler Residential Sprinkler (INSTA 900-1) Building type 3; 4 mm/min/m 2 Advantages: Designed to save life Various of design options Easy to combine with other Hazard Classifications Low cost solution - when water reservoir is not needed Very low pressure Low maintenance cost Disadvantages: High water demand and flux density 10 Higher cost when water reservoir is needed

Water Mist High Pressure Water mist OH 1; 1,5 2 mm/min/m 2 Advantages: Low water demand and flux density Smaller piping offers esthetical exposed pipe installations Disadvantages: High cost solution High maintenance cost Limited design variations Hard to combine with other Hazard classifications 11

Water Mist Low Pressure Water mist OH 1; 1,5 2,5 mm/min/m 2 Advantages: Low water demand and flux density Often a cost effective solution when a sprinkler solution requires a water reservoir or pump Maintenance cost equal to standard sprinkler Standard off the shelf material, except for the nozzles Disadvantages: Almost always need of a pump Limited design variations Limitations to combine with other 12

Kolding Sygehus (Hospital) - Denmark OH 1 500 pcs Aquamist nozzles ULF AM 27 & AM 29 Value for the customer New Technology Environmental friendly profile low water consumption & energy consumption 13

Home for Elderly People, Lahti - Finland OH 1 400 pcs Aquamist nozzles ULF AM 27 & AM 29 Value for the end user Limited water resource (City main), no water resvoir needed 14

Vasa Sjukhus (Hospital) Finland OH 1 (small areas OH 2) 2500 pcs nozzles New installation and retrofit OH 2 protected with deluge sprinkler system Value for the end user Limited water resource (City main), no water resvoir needed 15

Why water mist When the water source is below what a Standard Sprinkler system require depending on which Water Mist system a Water Mist solution may be an cost effective solution When a water reservoir is required depending on which Water Mist system a Water Mist system may be cost effective solution In occasions when the water density from a Standard Sprinkler system may give significantly more water damage than a Water Mist system. These occasion are lot less than the perception of what many people believe. 16

Thank You