LED Spotlight 15 W. Information Sheet. Features. ISALUX 15 series

Similar documents
WZ-T8-W18 T8 LED Tube Light

LED Seamless VaporProof Fixture Installation Instruction

Dimmable LED Retrofit Kit

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Product Specifications

LED Panel Light E830J

HIGH LUMINOUS EFFICIENCY

LUXCOMFO TM LED Flood Light Datasheet

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

E10 & L9 Low Wattage Light Cone Data

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

LED ROUND MINI PANELS

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

Vocare Ledlight SPECIFICATION. Product Name: LED Flood Light VL-FL-P200-P/WW. Part No: Approval No: OF 9. V2.

LED Shoplight fixture

Technical Application Guide for UP-SHINE LED Spotlight

HIGH POWER LED RETROFIT MODULE

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Technical Application Guide for UP-SHINE LED Track Light

110 lm w STANDARD SERIES

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

TG-Light Optoelectronic Ltd.

JEDI. Powerful recessed linear LED projector. Views

Vaya Linear LP, White & Mono

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Product Specifications

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

T8 LED LIGHTING TUBE (LUX V.)

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

Product Specifications MaxLumen MRI LED Diffused Lighting

SUBSTITUBE T8 CONNECTED TUBE

Industrial high bay projector PREMIUM LUX 12LED RECESSED IP43

Beautiful Light Technology Corp,.

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

AOD LED Panel Light AL-PL

5W LED Energy Saver PIR Bulkhead

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Technical Application Guide for UP-SHINE LED Ceiling light

JEDI. Powerful recessed linear LED projector. Views

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

PRODUCT LYNC IoT 37. PRODUCT: LYNC IoT

Technical Application Guide for PHILIPS LED Lamps

Technical Application Guide for UPSHINE LED Ceiling light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

Technical Application LED Pendant Light LUZ-PL W-W

LED Lamp 6W MR16. A New Experience in Light

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

LED Edge-Lit Flat Panels

UTILIZATION: INTERNAL COLOURS MATERIALS MEASURES BULBS DEVICE SPECIFICATIONS

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

The Commercial LED Lighting Specialist

Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design.

Sylproof Superia LED G2

700 Watt LED GROW LIGHT

ipanel LED Panel Light

LED Outdoor Wall Light Series

Product Specifications MaxLumen MRI LED Diffused Lighting

High Lux Performance White LED MR16 Lamp

LED Tri-proof Light. LED Tri-proof Light SPEC. Microwave Motion Sensor. Option: Remote control. Suitable for a variety of scenes

Product Specifications MaxLumen MRI LED Diffused Lighting

Ultra Energy Efficient

Inset Kit LED. Inset Trend Swing REF+ V2 5W 40 WH WW PRODUCT OVERVIEW

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

A low energy alternative to halogen which provide energy savings of around 90%

LED Golf Light B2C Frosted E14 40W

User Manual 120/240/300 Outdoor Motion Detector

LED Panel Light Specification List

Technical Application Guide for UP-SHINE LED Frameless Panel Light

lumen & ecoluz sustainable lighting by eco:d 1

FDV BA- Lighting AS BA24-CL76-8WD

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Urbanlite. We light your world IK08 IP

Flame Simulator User Manual. Publication Rev. A

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S

LINKABLE UNDERCABINET

IDOO.PENDANT POWER OVER ETHERNET (PoE) SUSPENDED LUMINAIRE

OLUX LED IN-GROUND OSRAM. Datasheet

Flow LED robust and streamlined

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Flow LED robust and streamlined

Technical Application Guide for UP-SHINE LED Panel Light

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

ENERGY EFFICIENT LED SOLUTIONS

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

PRODUCT CODE FIXTURE COLOR OPTICS WATTAGE COLOR TEMP + HOUSING DRIVER VOLTAGE

150W Explosion Proof LED Light - 5' Tall Base Stand Mount - 24" Stand - Class I Div 1 C&D V

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

VDS2510 Installation Manual

USER MANUAL Table of Contents

Transcription:

LED Spotlight 15 W Fullwat has unique products in ISALUX 15 series LED spotlight s. It uses high power LED including 15 W LED light source series products. It has excellent features like long lifetime (min. 20,000 hrs), high luminous efficacy and reduces environmental pollution. he ISALUX spotlight can suitable for 100-240V AC. It can be used for spotlight, security lighting and surveillance system. Features Indoor and outdoor use Comparable with mercury lamps 150 W Power factor > 0.9 for 115V AC; Power factor > 0.8 for 230V AC High power driver efficiency > 80% High luminous efficacy LED NO UV or IR radiation Compliance with safety standard: EN60598, EN61347-1+EN61347-2-13, EN55015+EN61547, EN60825-1, FCC Part 18 Cool light prevents heat buildup and associated heat degeneration Energy saving and environment friendly IP65 (without sensor type) / IP54 (with sensor or CCD type) dust and water proof

Specifications Item No. ISALUX15-BCXX-001 ISALUX15S-BC60-001ISALUX15-BFXX-001 ISALUX15S-BF60-001 ISALUX15C-BF60-001 CCT (Typical) Typical Power Consumption Luminou s Flux (lm) Inpu t Voltage Input AC Current (Max.) Operation Temp. Range Typical Luminou s Efficac y CRI Beam Angle Warranty Appli cation s 3000 K 6000 K 20 W 21 W 20 W 21 W 650 lm 950 lm 100-240V AC 115V AC / 1.5A ; 230V AC /1A -20 C ~ +40 C 33 lm/w 31 lm/w 48 lm/w 46 lm/w >80 >75 30 /60 60 30 /60 60 1 Year Indoor and Outdoor Lighting/ Architectural Lighting/ Landscape Lighting/ Spot Lighting/Public Place Lighting/ Security Lighting/ Surveillance System Outline Dim 185*175*130 185*260*140 185*175*130 185*260*140 Net Weight Package 1.2 (Kgs) 1.3 (Kgs) 1.2 (Kgs) 1.3 (Kgs) 6 Boxes / Carton Box Dimension / Weigh t Without sensor: L=195*148*190 / 1.6 (Kgs) With sensor: L=285*197*148 / 1.8 (Kgs)

Sensor (optional) Sensor Style Automatic infrared heat detector Sensing Coverage 4-15 meters. Center-horizontal moving Detection Range 90 110 Ligh t Up Time 7 seconds to 12 minutes Operating 24 hrs Protection Device Inlaid with 220 V / 10A 5 x 20 mm fuse CCD (opt ional) Image Pick-up Device Sony 1/3" color CCD Gamma Characteristic 0.45 Lens Furnished Board lens 3.6 mm / f2.0 Video Outp ut 1 vp-p composite video / 75 ohms S/N Ratio S/N More than 48 db Gain Control Automatically Sign al 24H 1Vp-p video signal output Horizontal Resolution 380TVL (optional 480TVL / 540TVL ) Work Frequenc y 60Hz(110V) / 50Hz (220V)

Candle Power Distribution Curve ( 15 W / 3 M) ISALUX15-BF60-001 / ISALUX15S-BF60-001 / ISALUX15C-BF60-001 ISALUX15-BC60-001 / ISALUX15S-BC60-001 ISALUX15-BF30-001

ISALUX15-BC30-001 Dimensions 1. ISALUX15 185.0 mm 130.0 mm 175.0 mm 2. ISALUX15S 185.0 mm 140.0 mm 260.0 mm

3. ISALUX15C 185.0 mm 140.0 mm 260.0 mm Energ y Saving & CO 2 Reduction Comp arison Table Item Life Time Typical Power Consu mption Typical Power Consu mption per year (12hrx3 65day/KWh)*A=B CO 2 Quanti ty (Kgs/ year) (0.637*B=D) Energ y Saving Rate (Compare with Merc ury Lamps) GL-SP-15CW (6000 K) Merc ury Lamps 20,000 hrs 3,000 hrs 20 W 150 W 87.6 KW 657 KW 39 Kgs 291 Kgs 86% CO2 calculation reference 0,44 kg Co2 / kwh UNESA year 2007

~ ~ ISALUX 15 series User Manual Thanks for your choice of LED ISALUX 15 series products. Please ensure that you install and use the product according to the below directions to enable the correct implementation and normal functioning of the LED product. Should you not follow these directions, you will not be compensated in accordance with the warrantee. We will not take any responsibility from the improper use and implementation of the product, and for any associated damage caused by such irresponsible and negligent actions. CAUTION 1. The Warranty Period is two one (2) (1) years. year. We will warrant free repair or replacement services if the product fails or becomes defective during normal use within the prescribed warrantee period. Please send back the product to our company or contact your local distributors for further directions. 2. Do not change or tamper with any internal electric circuits or add in any wires or cables for any reason. 3. Do not change the mechanical design, circuit specifications, or components; do not add any other devices as this may cause the product to short circuit or may create other unforeseen risks. 4. Keep the lamp set in a dry environment in order to avoid any electricity leakage. 5. To avoid electrical shocks and possible malfunction, please do not insert objects of any nature into the LED product. 6. For further information, please contact us. CAUTION CLASS 2 LED LIGHT DO NOT STARE INTO THE BEAM Installation process Please get professional installation personnel to set up the fixture. 1. Before installation, please turn off the power switch for the existing bulb. 2. Please make sure that the specifications of the power connector and the output voltage are compatible to the LED fixture used. 3. At the rear side of the LED fixture, please connect the Live (L) and Neutral (N) terminal are used for connecting to power output. Please follow the standard process to connect them accordingly and do insulation on both terminal respectively. 4. Screw the LED fixture tight onto a wall or a stand and adjust the angle in accordance with individual needs. 100V-240V~ 50-60Hz AC wire (L) black or brown AC wire (N) white or blue AC wire (L) black or brown Ground wire green AC wire (N) white or blue Ground wire green 5. Please plug the unit into an appropriate power socket and turn the power on. If the lamp does not work, please repeat steps 1-4 until it does work. Best Position Pick a vantage point based on the directions of human and car traffic Install the sensor at a location within 10 ~ 15 meter radius of the vantage point, 2.5 ~ 3 meter high and at an angel of adjustable sensor is up / down 10 ~ 30 (best at 90 degree) Make sure the sensor is firmly screwed Indicators on the bottom of the sensors Best sensing effects, Longest sensing range Installation height and sensing angle are proper (Lateral Moving) 3 ~ 5 m 90 ~ 100 10 m 15 m 2.5 m 3 m 3 m 30 ~ 35 10 m ~ 15 m SENS LUX TIME Worst sensing effects Insufficent range due to low sensing angle (Straightline moving forward) Short sensing range and prone to false detections due to high sensing angle 1. SENS: The intensity of sensing. + indicates strong sensing. - indicates weak sensing. 2. LUX: The brightness of the environment. Moon mark (>3 lux) indicates night sensing; effective when human entering the sensing area in low illuminations. Please avoid strong light resource because it may lead sensor to false detections. Sun Mark indicates 24-hour sensing regardless day or night. It is effective. 3. TIME: The light up time of sensing. From 7 seconds to 12 minutes.