INSTRUCTION MANUAL HS-208REVI

Similar documents
INSTRUCTION MANUAL HS-229G

Series B Inverted Bucket Steam Traps

Installation and Testing of Inverted Bucket Steam Traps Manual

Installation and Maintenance "L" and "LS" Series

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Clean Steam Generators

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

INSTRUCTION MANUAL MM-226D

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

MaxLite LED MICRO-T PANEL

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

TrueClean ToteCleaner

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

TrueClean ToteCleaner

INSTALLATION, OPERATION AND MAINTENANCE

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Compact Equipment Warranty Policy

Duct Mount. Installation Instructions

XT Series Thermostats

ion Genesis Pump Controller

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

Ace Heaters LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

Humidistat-Thermostat

Installation, Operation, and Maintenance Manual

STEAM WALLPAPER STRIPPER MODEL HTW5

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

Industrial Vacuums, Inc

INSTALLATION AND OPERATING MANUAL

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

US 11/2005. Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3. Instruction manual

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Heater Installation Kit

Series 1140 and 1141 Temperature Regulators

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

INSTALLATION AND OPERATING MANUAL

Ace Heating Solutions, LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

Desiccant Air Drying System

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

INSTALLATION AND USER INSTRUCTION GUIDE. Electric Fire With Remote Control. Model: WM-3522CF. Please read all instructions carefully and

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

MaxLite LED High Bay Fixtures

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

BLT-999W-2 Item # 60757

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

DBF 4XL Dryer Booster Fans

- User Brochure Programmable Thermostat 510

Light Construction Equipment Consumer Warranty Policy

55-Gallon Dispenser Package

1 HP Air Mover. Owner s Manual

COMBUSTION AIR SYSTEM

Desiccant Air Drying System

WIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

Installation Instructions PP-AS20 Anti-Scale System

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Smart IR Sensor. Installation and Operation Manual PNEG Date: PNEG-1640

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

Flat Line Spray Systems Kits

IMPORTANT SAFETY INFORMATION:

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

PROPANE CONSTRUCTION HEATER

GTS. User Manual. Gas-to-Steam Humidifier. Affix product label here.

YOUR PORTABLE AIR PURIFIER

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Owner s Manual. PIR-1 IR Learner

PROPANE CONSTRUCTION HEATER

WM-50 INSTALLATION AND OPERATING INSTRUCTIONS ELECTRIC FIREPLACE. Edition)

Patent Pending invent for New Construction

Pressurized Filter Up to 1250 gallons

VP17A BUNN OPERATING & SERVICE MANUAL

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

WHOLE HOUSE FILTER &

55-Gallon Dispenser Package

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

MN908 No. 282C Replaces 282B LB7013

FOR EASY, FAST INSTALLATION AND FOR RESULTS

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

INTERMEDIATE GUIDE BRACKET

IMPORTANT SAFETY INFORMATION:

Transcription:

INTRUCTION MANUAL H-208REVI 510900

WARNING CAUTION! WARNING efore using product, read and understand instructions. ave these instructions for future reference. All work must be performed by qualified personnel trained in the proper application, installation, and maintenance of steam systems in accordance with all applicable codes and ordinances. To prevent serious burns, wear heat resistant gloves when opening and closing steam valves, or handling hot equipment. To prevent serious personal injury from steam pipe blow down, connect a temporary pipe between the steampipe opening and a drain, or stand at least 100 ft. (30m) from the pipe opening. To prevent property damage, personal injury, or death, cap off the gate valves if they are not connected to a drain and when they are not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury or death. IMPORTANT: To prevent system damage from water hammer or sudden shock, open supply valves slowly. If you are uncertain about the product s adaptability for your application, please call the factory or authorized representative before using the product. The trap seat rating (stamped on the nameplate) must be equal to or greater than the maximum pressure differential across the trap. 2

OPERATION UCKET TRAP EAT I OPEN TO VENT AIR OR DRAIN CONDENATE During start-up, air is vented through the bleed hole, at the top of the bucket, into the return line. leed Hole Cover Open eat Condensate entering the trap will flow around the bucket and drain through the open seat. Inlet Outlet ody ucket UCKET TRAP EAT I CLOED TO RETAIN LIVE TEAM As steam flows into the bucket trap it collects at the top of the bucket. The buoyancy of the steam raises the bucket and closes the seat. The bucket remains full of steam until more condensate enters the trap. The cycle is then repeated. Inlet leed Hole Cover Closed eat Outlet ucket ody team ubbles Through Water UCKET TRAP WITH OPTIONAL THERMAL VENT FOR FATER AIR VENTING Models with an optional factory installed thermal vent in the bucket allow faster air venting during start-up. Inlet Outlet Thermal Vent 3

INTALLATION eries 0, 1, 2, 3 & 4 Inverted ucket Traps 1. Determine where to install the trap, based on the following requirements: a. The trap must be located as close as possible and below the equipment to be drained. b. The trap must be in a straight run of horizontal pipe and pitched to allow condensate to flow into the trap inlet and away from the trap outlet. Refer to the Typical Piping Diagrams at the right. c. Plenty of space around the trap is needed for servicing, which may include removal of the body or cover. tatic Head Tee Fitting tatic Head Tee Fitting TYPICAL PIPING DIAGRAM Trap Draining to Open Drain Equipment Drain Point Inlet Pipe hut-off Valve Y trainer Dirt Pocket Pipe Union ucket Trap Gate Valve For low Down To Drain Outlet Pipe Trap Draining to Gravity Return Line Equipment Drain Point Inlet Pipe hut-off Valve Dirt Pocket Y trainer Pipe Union Gate Valve For low Down Pipe Elbow hut-off Valve Tee Fitting ucket Trap hut-off Valve To Return Line Pipe Elbow To Drain Gate Valve For Test & Pressure Relief Gravity Return To Vented Receiver Trap Draining to Overhead Return Line or Pressurized Return Line tatic Head Equipment Drain Point Inlet Pipe hut-off Valve Pipe Union ucket Trap Tee Fitting Check Valve hut-off Valve Return Line tatic Head Against Discharge 1 /2 psi/ft. (.035 bar per.3m) Tee Fitting Dirt Pocket Y trainer Gate Valve For low Down To Drain Gate Valve For Test & Pressure Relief Pressurized Return Line 4

2. Install near trap piping: a. Install a shut-off valve (A) on the inlet pipe (). b. Install a Hoffman pecialty Y trainer (C) on the inlet pipe (). A c. Install a gate valve for blow down (D) by connecting it to the Y trainer drain tapping (C). C D d. Cap off the outlet pipe (X). e. lowly turn steam on with full pressure for (5) five minutes to blow down the inlet pipe (). f. Turn off steam and allow pipe to cool. g. Remove cap from the outlet pipe (X).! WARNING To prevent serious personal injury from steam pipe blow down, connect a temporary pipe between the steam pipe opening and a drain, or stand at least 100 ft. (30m) from the pipe opening. Failure to follow this warning could cause property damage, personal injury, or death. D X Pipe Opening! CAUTION To prevent serious burns, the internal pressure of the trap must be 0 psi (0 bar) before servicing. Failure to follow this caution will cause personal injury. h. Close the gate valve (D). If it is not connected to a drain, install a cap (E) on the outlet pipe (F). Note: Remove the cap (E) when the gate valve (D) is used for test or pressure relief. Recap when the test or pressure relief is complete.! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. F E D 5

i. Install a pipe union (G) on the inlet pipe (). G 3. Position the bucket trap so that the cover (J) is on top and the inlet pipe () will connect with the IN tapping on the body (H). J H 4. Install the bucket trap (K) on the inlet pipe () as positioned in tep 8. K For Applications with a Return Line 5. Install a tee fitting (L) on the return line (K) near the trap outlet (H). K L H 6a. Install a gate valve (M) on the outlet pipe (N) for test or pressure relief. b. Close the gate valve (M). N M 6

7. If the gate valve (M) is not connected to a drain, install a cap (P) on the outlet pipe (N). Note: Remove the cap (P) when the gate valve (M) is used for test or pressure relief. Recap when the test or pressure relief is complete. N M P! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. For Applications with a Gravity Return, Pressurized Return or Return Line Above the Trap Discharge 8. Install a check valve (R) on the return line (K). K R For All eries 0, 1, 2, 3 & 4 Applications 9. Install a shut-off valve () on the return line (K). K 7

10. Depending on your application, complete one of the following steps: a. Connect the return line (K) to a drain (T) T K OR b. Add a gravity return line (U) U OR c. Add a pressured return (V) or a return line above the trap discharge (W). A check valve (R) (see tep 8) must be installed for pressurized returns and return lines above trap discharge. R W V 11. Prime the bucket trap as follows while the equipment is operating: a. Close the shut-off valve () on the return line (K) for (1) one minute. b. lowly open the shut-off valve () on the return line (K). K INTALLATION COMPLETE 8

ERIE 6 INVERTED UCKET TRAP 1. Determine where to install the trap, based on the following requirements: a. The trap must be located as close as possible and below the equipment to be drained. b. The trap must be in a straight run of vertical pipe. Refer to the Typical Piping Diagram at the right. c. Plenty of space around the trap is needed for servicing, which may include removal of the body or cover. TYPICAL PIPING DIAGRAM Trap Draining to Main Return Line Above or elow Trap Discharge tatic Head Equipment Drain Point Gate Valve For Test & Pressure Relief afety Cap Inlet Pipe Pipe Elbow Pipe Union Check Valve Return Line ucket Trap Main Return Line hut-off Valve tatic Head Against Discharge 1/2 psi/ft. (.035 bar per.3m) Main Return Line hut-off Valve Pipe Union Inlet Pipe Tee Fitting Dirt Pocket Y trainer Gate Valve For low Down Pipe Elbow 2. Install near trap piping: a. Install a shut-off valve (A) on the inlet pipe (). b. Install a Hoffman pecialty Y trainer (C) on the inlet pipe (). A c. Install a gate valve for blow down (D) by connecting it to the Y trainer drain tapping (C). C D 9

d. Cap off the outlet pipe (X). e. lowly turn steam on with full pressure for (5) five minutes to blow down the inlet pipe (). f. Turn off steam and allow pipe to cool. g. Remove cap from the outlet pipe (X).! WARNING To prevent serious personal injury from steam pipe blow down, connect a temporary pipe between the steam pipe opening and a drain, or stand at least 100 ft. (30m) from the pipe opening. Failure to follow this warning could cause property damage, personal injury, or death. D X Pipe Opening! CAUTION To prevent serious burns, the internal pressure of the trap must be 0 psi (0 bar) before servicing. Failure to follow this caution will cause personal injury. h. Close the gate valve (D). If it is not connected to a drain, install a cap (E) on the outlet pipe (F). Note: Remove the cap (E) when the gate valve (D) is used for test or pressure relief. Recap when the test or pressure relief is complete. F E D! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. i. Install a pipe union (G) on the inlet pipe (). G j. Install a pipe elbow (H) on the inlet pipe (). H 10

3. Position the bucket trap so that the cover (J) is on top and the inlet pipe () will connect with the bottom inlet tapping (K). J K 4. Install the bucket trap (L) on the inlet pipe () as positioned in tep 9. L 5. Remove the 1/2" (15mm) pipe lug (L) on the trap cover (J). L J 6. Connect an outlet pipe (M) on the tapping where the pipe lug was removed. M N P 7. Install pipe elbows (N) and (P) on the outlet pipe (M). M 11

8a. Install a gate valve (Q) on the outlet pipe (M) for test or pressure relief. b. Close the gate valve (Q). Q M 9. If the gate valve (Q) is not connected to a drain, install a cap (R) on the outlet pipe (M). Note: Remove the cap (R) when the gate valve (Q) is used for test or pressure relief. Recap when the test or pressure relief is complete. Q R M! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. 10. Install a return line () in the trap outlet tapping (T). T 11. Install a pipe elbow (U) on the return line (). U 12

12. Install a pipe union (V) on the return line (). V 13. Install a check valve (W) on the return line (). W 14. Install a shut-off valve (X) on the return line (). X 13

15. Depending on your application, install a pipe elbow to the trap return line () and connect it to: Y a. A main return above the trap discharge (Y). OR Z b. A main return below the trap discharge (Z). 16. Prime the bucket trap as follows once the equipment is operating: X a. Close the shut-off valve (X) on the return line () for (1) one minute. b. lowly open the shut-off valve (X) on the return line (). INTALLATION COMPLETE 14

COMMERCIAL WARRANTY Warranty. For goods sold to commercial buyers, eller warrants the goods sold to uyer hereunder (with the exception of membranes, seals, gaskets, elastomer materials, coatings and other wear parts or consumables all of which are not warranted except as otherwise provided in the quotation or sales form) will be (i) be built in accordance with the specifications referred to in the quotation or sales form, if such specifications are expressly made a part of this Agreement, and (ii) free from defects in material and workmanship for a period of one (1) year from the date of installation or two (2) years from the date of manufacture, whichever shall occur first, unless a longer period is specified in the product documentation (the Warranty ). Except as otherwise required by law, eller shall, at its option and at no cost to uyer, either repair or replace any product which fails to conform with the Warranty provided uyer gives written notice to eller of any defects in material or workmanship within ten (10) days of the date when any defects or non-conformance are first manifest. Under either repair or replacement option, eller shall not be obligated to remove or pay for the removal of the defective product or install or pay for the installation of the replaced or repaired product and uyer shall be responsible for all other costs, including, but not limited to, service costs, shipping fees and expenses. eller shall have sole discretion as to the method or means of repair or replacement. uyer s failure to comply with eller s repair or replacement directions shall terminate eller s obligations under this Warranty and render the Warranty void. Any parts repaired or replaced under the Warranty are warranted only for the balance of the warranty period on the parts that were repaired or replaced. eller shall have no warranty obligations to uyer with respect to any product or parts of a product that have been: (a) repaired by third parties other than eller or without eller s written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or physical damage; (c) used in a manner contrary to eller s instructions for installation, operation and maintenance; (d) damaged from ordinary wear and tear, corrosion, or chemical attack; (e) damaged due to abnormal conditions, vibration, failure to properly prime, or operation without flow; (f) damaged due to a defective power supply or improper electrical protection; or (g) damaged resulting from the use of accessory equipment not sold or approved by eller. In any case of products not manufactured by eller, there is no warranty from eller; however, eller will extend to uyer any warranty received from eller s supplier of such products. THE FOREGOING WARRANTY I EXCLUIVE AND IN LIEU OF ANY AND ALL OTHER EXPRE OR IMPLIED WARRANTIE, GUARANTEE, CONDITION OR TERM OF WHATEVER NATURE RELATING TO THE GOOD PROVIDED HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIE OF MERCHANTAILITY AND FITNE FOR A PARTICULAR PURPOE, WHICH ARE HEREY EXPRELY DICLAIMED AND EXCLUDED. EXCEPT A OTHERWIE REQUIRED Y LAW, UYER EXCLUIVE REMEDY AND ELLER AGGREGATE LIAILITY FOR REACH OF ANY OF THE FOREGOING WARRANTIE ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND HALL IN ALL CAE E LIMITED TO THE AMOUNT PAID Y THE UYER FOR THE DEFECTIVE PRODUCT. IN NO EVENT HALL ELLER E LIALE FOR ANY OTHER FORM OF DAMAGE, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONEQUENTIAL, PUNITIVE, EXEMPLARY OR PECIAL DAMAGE, INCLUDING UT NOT LIMITED TO LO OF PROFIT, LO OF ANTICIPATED AVING OR REVENUE, LO OF INCOME, LO OF UINE, LO OF PRODUCTION, LO OF OPPORTUNITY OR LO OF REPUTATION. LIMITED CONUMER WARRANTY Warranty. For goods sold for personal, family or household purposes, eller warrants the goods purchased hereunder (with the exception of membranes, seals, gaskets, elastomer materials, coatings and other wear parts or consumables all of which are not warranted except as otherwise provided in the quotation or sales form) will be free from defects in material and workmanship for a period of one (1) year from the date of installation or two (2) years from the product date code, whichever shall occur first, unless a longer period is provided by law or is specified in the product documentation (the Warranty ). Except as otherwise required by law, eller shall, at its option and at no cost to uyer, either repair or replace any product which fails to conform with the Warranty provided uyer gives written notice to eller of any defects in material or workmanship within ten (10) days of the date when any defects or non-conformance are first manifest. Under either repair or replacement option, eller shall not be obligated to remove or pay for the removal of the defective product or install or pay for the installation of the replaced or repaired product and uyer shall be responsible for all other costs, including, but not limited to, service costs, shipping fees and expenses. eller shall have sole discretion as to the method or means of repair or replacement. uyer s failure to comply with eller s repair or replacement directions shall terminate eller s obligations under this Warranty and render this Warranty void. Any parts repaired or replaced under the Warranty are warranted only for the balance of the warranty period on the parts that were repaired or replaced. The Warranty is conditioned on uyer giving written notice to eller of any defects in material or workmanship of warranted goods within ten (10) days of the date when any defects are first manifest. eller shall have no warranty obligations to uyer with respect to any product or parts of a product that have been: (a) repaired by third parties other than eller or without eller s written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or physical damage; (c) used in a manner contrary to eller s instructions for installation, operation and maintenance; (d) damaged from ordinary wear and tear, corrosion, or chemical attack; (e) damaged due to abnormal conditions, vibration, failure to properly prime, or operation without flow; (f) damaged due to a defective power supply or improper electrical protection; or (g) damaged resulting from the use of accessory equipment not sold or approved by eller. In any case of products not manufactured by eller, there is no warranty from eller; however, eller will extend to uyer any warranty received from eller s supplier of such products. THE FOREGOING WARRANTY I PROVIDED IN PLACE OF ALL OTHER EXPRE WARRANTIE. ALL IMPLIED WARRANTIE, INCLUDING UT NOT LIMITED TO THE IMPLIED WARRANTIE OF MERCHANTAILITY AND FITNE FOR A PARTICULAR PURPOE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF INTALLATION OR TWO (2) YEAR FROM THE PRODUCT DATE CODE, WHICHEVER HALL OCCUR FIRT. EXCEPT A OTHERWIE REQUIRED Y LAW, UYER EXCLUIVE REMEDY AND ELLER AGGREGATE LIAILITY FOR REACH OF ANY OF THE FOREGOING WARRANTIE ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND HALL IN ALL CAE E LIMITED TO THE AMOUNT PAID Y THE UYER FOR THE DEFECTIVE PRODUCT. IN NO EVENT HALL ELLER E LIALE FOR ANY OTHER FORM OF DAMAGE, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONEQUENTIAL, PUNITIVE, EXEMPLARY OR PECIAL DAMAGE, INCLUDING UT NOT LIMITED TO LO OF PROFIT, LO OF ANTICIPATED AVING OR REVENUE, LO OF INCOME, LO OF UINE, LO OF PRODUCTION, LO OF OPPORTUNITY OR LO OF REPUTATION. ome states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. ome states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. To make a warranty claim, check first with the dealer from whom you purchased the product or call +1-847-966-3700 for the name and location of the nearest dealer providing warranty service. Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379 www.bellgossett.com ell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. 2016 Xylem Inc. H-208REVI January 2016 Part No. 510900