Connection of CET4-AR to safety relay PNOZ X3.10P

Similar documents
Connection of CET4-AR to safety relay PNOZ s5

Connection of CES-AP to safety relay PNOZ s4.1 Content

Connection of CET4-AP to Siemens ET 200S

Examples for Use of the MGB Inputs and Outputs

Simply safe. Transponder-coded safety switch CET with guard locking

Simply safe. Transponder-coded safety switch CET with guard locking

Multifunctional Gate Box MGB. More than safety.

More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode)

Safety Function: Single-beam Area Access Control (AAC)

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

SAFETY RELAY APPLICATION

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

MACHINERY SAFEBOOK 5. Safety related control systems for machinery. Principles, standards and implementation. (Revision 5 of the Safebook series)

ATEX Safety Switches. More than safety.

SPECIALISTS IN SAFETY ENGINEERING FOR THE PACKAGING INDUSTRY.

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Magnetically Coded Non-contact Switch (MC2)

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Highlights Solutions for you. DOLD - Our experience. Your safety.

Original operating instructions Safety switch with guard locking AC901S AC902S

Non-contact, coded safety switches PSEN

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Preventa safety modules

Operating instructions Mini Jet Ionisator. Air Line V01

Operating Guide Safe Torque Off

The EN54 Part 2 & 4 Fire System

Operating instructions

Basics of Safety Applications

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

Basics of Safety Applications

/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.

SensaGuard TM Integrated Latch Installation Instructions

ISIS SAFETY SYSTEM Installation guide

PROTECT SRB 200EXi-1A

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

One giant leap for safety: AZM400.

First of all, what is a safety-related

Machine Guarding and Safety

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Operating Guide Safe Torque Off

Original instructions Sense7-series Non-contact coded safety switch

Operating instructions

100 Series Gas Ventilation Interlock System

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly


ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

Hazard and Risk Assessment Guide for Dumpmaster bin-tipping machines

Standard package Safexpert Standard Standard package Safexpert Standard PLUS Small Standard package Safexpert Standard Plus

/ / 2018

Use of control and analytical X-ray apparatus

Important Safety Notice

Installation Instructions. devireg 700/ /752/753/754

Multifunctional Gate Box MGB. More than safety.

Be sure DC power is applied safely to terminals 3-4. Use caution during testing.

OPERATING MANUAL Enertronic Control System 2

Australian Standard. Safeguarding of machinery

Safexpert. Standards. Trainings & Seminars. Price list EUR. January 2019

Datasheet - MZM 100 ST2-1P2PWREM-A

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

Control Panel Basics Volume 1

Datasheet - MZM 100 ST-SD2PREM-A

System 800 Addressable Fire Detection & Alarm System

Dohse Aquaristik GmbH & Co. KG

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Datasheet - MZM 100 B ST2-SD2PREM-A

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Sensing light curtain as per DIN 18650/EN 16005

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants

Translation of the assembly instructions with operating instructions and technical appendix

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

WaterFurnace FX10 Application Guide Reversible Chiller

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Interfacing with the ADAM Module


Sensing light curtain as per DIN 18650/EN 16005

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

9 Standards, Regulations and Authorities

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating Manual MS220DA

Safe area; Zone 1 and Zone 2

Cooling Unit for Producing Chilled Water. Envicooler. Operation and Maintenance Instructions. Air handling with the focus on LCC

Instructions for the fan motor control system, SILVER C

ENGLISH USER S MANUAL PRE SOAKER 3600

Basically, the instruction handbook shall contain the following information:

British Standards for Machinery Guarding

DIRECTIVE NO: D-B

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

Application, Installation, Operation & Maintenance Manual

Alarm system For oil-water separator

Room Temperature Controllers

Feature Summary. I. System

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 1: Test methods

Pilz for a safe crane system

Transcription:

Connection of CET4-AR to safety relay PNOZ X3.10P Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other... 2 Functional description... 3 General... 3 Connections... 3 Safety assessment... 3 Principle circuit diagram... 4 Setting of the Reset mode for PNOZ X3.10P... 5 Manual reset... 5 Automatic reset... 5 Important note please observe carefully!... 6 AP000125-05_03/16 Page 1 of 6

Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle) Safety function Reliability figures according to EN ISO 13849 Category 4, PL e Guard locking for process protection with interlocking according to EN ISO 14119 Components/modules used EUCHNER Description Safety switches with guard locking and guard locking monitoring with transponder technology Order no./item designation 113609 / CET4-AR-CRA-CH-50X-SG-C2355-113609 Tip: More information and downloads about the above mentioned EUCHNER products can be found at www.euchner.de. Simply enter the order number into the search field. Other Description Items Safety relay PNOZ X3.10P / 777 314 AP000125-05_03/16 Page 2 of 6

Functional description General The CET4 is a guard locking device according to EN ISO 14119 using the open-circuit current principle. The two safe outputs of the CET4 are connected to a PNOZ X3.10P safety relay. Connections Designation Function Use in this example OA, OB IA, IB Safety outputs. HIGH when the safety guard is closed and locked. Inputs for series connection of AR devices from EUCHNER. Switch-off of at least one of the outputs leads to a direct switch-off of the safety contacts (13 14, 23 24, ) of the safety relay PNOZ X3.10P. Important: The actual shutdown of the energy which is causing a hazard in a machine is not shown in the example and must be supplemented. Connected to 24 V DC; function is not used. +UCM, 0V (UCM) OUT OUTD Control input for guard locking solenoid. Connect guard locking to 24 V DC to close. Monitoring output. HIGH when outputs OA and OB are switched on (safety guard closed and locked). Door monitoring output. HIGH when the actuator is within the operating distance and the CET is ready to engage guard locking (safety guard closed). Activated by switch S1. 0V (UCM) connected to GND. Important: According to EN ISO 14119, it shall be ensured that the hazard caused by a machine has disappeared before the guard locking can be released. Function not used. Function not used. RST Input for resetting the switch Connected to ground; function is not used. NC Input not connected Do not connect. Safety assessment The CET4 features complete monitoring for faults in the safety-relevant parts and in the connected cables (clock pulses at outputs OA and OB). The safety relay PNOZ X3.10P achieves up to PL e according to the manufacturer s information (see the device s operating instructions for this purpose). The wiring corresponds to the circuit Light beam device with detection of shorts across contacts via ESPE in the operating instructions of the PNOZ X3.10P. Therefore, PL e in accordance with EN ISO 13849-1 can be achieved for locking mechanism position monitoring of guard locking of the CET4. In exceptional cases in accordance with the risk assessment, guard locking can also be used for safety-relevant purposes. More detailed information about this can be found in EN ISO 14119. In this case, locking mechanism position monitoring of guard locking also meets the requirements of PL e. A safety assessment for control of guard locking is not part of this example and must be supplemented for the respective machine by the design engineer in accordance with the risk assessment. Important: Switch-off of the energy and any necessary monitoring energy switch-off (feedback loop) of the hazard are not part of this document and must be added in accordance with the risk assessment for the machine. In this example, the safety evaluation unit without feedback loop and without start button is used. Please refer to the operating instructions of the safety evaluation unit used for more information. AP000125-05_03/16 Page 3 of 6

Principle circuit diagram In the example Automatic Reset of the PNOZ X3.10P is used Figure 1 AP000125-05_03/16 Page 4 of 6

Setting of the Reset mode for PNOZ X3.10P Only with the following settings does the safety relay PNOZ X3.10P operate correctly with a CET4-AR. Manual reset Automatic reset AP000125-05_03/16 Page 5 of 6

Important note please observe carefully! This document is intended for a design engineer who possesses the requisite knowledge in safety engineering and knows the applicable standards, e.g. through training for qualification as a safety engineer. Only with the appropriate qualification is it possible to integrate the introduced example into a complete safety chain. The example represents only a part of a complete safety chain and does not fulfill any safety function on its own. In order to fulfill a safety function, the energy switch-off function for the hazard location and the software within the safety evaluation must also be considered, for example. The introduced applications are only examples for solving certain safety tasks for protecting safety guards. The examples cannot be comprehensive due to the application-dependent and individual protection goals within a machine/installation. If questions pertaining to this example remain open, please contact us directly. In accordance with Machinery Directive 2006/42/EC, the design engineer of a machine or installation is obligated to perform a risk assessment and take measures to reduce the risk. When doing this, the engineer must comply with the applicable national and international standards. Standards generally represent the current state of the art. Therefore, the design engineer should continuously inform himself about changes in the standards and adapt his considerations to them. Relevant standards include EN ISO 13849 and EN 62061. This application must be regarded only as assistance for the considerations about safety measures. The design engineer of a machine/installation is obligated to assess the safety technology himself. The examples must not be used for assessment, because only a small excerpt of a complete safety function was considered in terms of safety engineering here. In order to be able to use the safety switch applications correctly on safety guards, it is indispensable to observe the standards EN ISO 13849-1, EN ISO 14119 and all relevant C-standards for the respective machine type. Under no circumstances does this document replace the engineer s own risk assessment, and it cannot serve as the basis for a fault assessment. Particularly in case of a fault exclusion, it must be noted that this can be performed only by the design engineer of a machine or installation and requires a reason. A general fault exclusion is not possible. More information about fault exclusion can be found in EN ISO 13849-2. Changes at products or within assemblies from third-party suppliers used in this example can lead to the function no longer being ensured or the safety assessment having to be adapted. In any event, the information in the operating instructions on the part of EUCHNER, as well as on the part of third-party suppliers, must be taken as the basis before this application is integrated into an overall safety function. If contradictions should arise between the operating instructions and this document, please contact us directly. Use of brand and company names All mentioned brand and company names are property of the respective manufacturers. The use is only for clear identification of compatible peripheral devices and environment of operation in combination with our products. EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Telefon: +49 711 75 97-0 Telefax: +49 711 75 97-303 info@euchner.de www.euchner.de AP000125-05_03/16 Page 6 of 6