XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Similar documents
LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Download the BEA DECODER app for a quick overview of settings

Download the BEA DECODER app for a quick overview of settings

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

DDS-A / DDS-B HYBRID SENSOR

Motorised Infrared Optical Beam Smoke Detector. User Guide

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Motorised Infrared Optical Beam Smoke Detector. User Guide

Sensing light curtain as per DIN 18650/EN 16005

/ / 2018

FIRERAY 5000 range USER GUIDE

Sensing light curtain as per DIN 18650/EN 16005

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

SCHMIDT LED Measured Value Display MD Instructions for Use

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Detector switch - Dual Tech SCS

Instructions for the fan motor control system with integrated wiring terminals SILVER C

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Class 1 laser beam sensor safe for your eyes

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Apollo Intelligent Auto Aligning Beam Detector. User Guide

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Class 1 laser beam sensor safe for your eyes

Quick Start Guide. 4MP Vandal Dome Fixed Lens IP Camera O4D1

COMPACT FLAME CONTROLLER CFC 100

Original operating instructions Safety switch with guard locking AC901S AC902S

BODYGUARD-T USER S GUIDE

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Secure WANDERING INSTALLATION AND USAGE GUIDE

SCS motion sensors Surface/wall mounting - PIR

Laser Distance Sensor Type M Analog-Output

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Snifter ATEX22 VERSION. User Manual. Distributor

Laser Collimated Beam Sensor

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Snifter. User Manual. Distributor

Class 1 laser beam sensor safe for your eyes

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Customers must fill in and mail the warranty card in order to activate the warranty.

SICK AG WHITEPAPER. safehddm TM THE NEW SCANNING TECHNOLOGY FOR SAFETY LASER SCANNERS

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

ISIS SAFETY SYSTEM Installation guide

English. Italiano. Português. Françias. Español

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

3kW 6kW, QUBE Fiber Lasers

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

AO Annunciator Module

Instruction manual EN

Instructions for the fan motor control system, SILVER C

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

E3M-V. Mark Sensor. Applications

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Detector switch - Dual Tech

S304 and S305 Dust Emission Monitors. User Manual. Distributor

G4 Pulsed Fiber Laser

Important Safety Notice

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

SensaGuard TM Integrated Latch Installation Instructions

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

DD205RF/TX Detector Installation Sheet

D-Tect 2 GJD300 Quad PIR Movement Detector

COMPACT FLAME CONTROLLER CFC 1000

HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0

Open-area Smoke Imaging Detection (OSID)

RS Pro Infrared Temperature Sensor

End To End Optical Beam Smoke Detector. Additional Information

Forced draught gas burner

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

HLS-2C Active Hearing Loop Panel

MANUAL Overflow sensor NVF-104/34-PF

64 Max IR Thermometer

FEC403EN Installation Manual

Optical laser distance sensors. Dimensioned drawing

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Instruktions manual. At skræmme fugle med laser!

Transcription:

EN XGUARD-0/-5 LASER SCANNERS for industrial doors XGUARD-0: max. detection range of 9.9 m x 9.9 m XGUARD-5: max. detection range of 5.0 m x 5.0 m User s Guide for product version 0600 and more

SAFETY The device contains IR and visible laser diodes. IR laser: wavelength 905nm; max. output pulse power 75W (Class according to IEC 6085-) Visible laser: wavelength 650nm; max. output CW power mw (Class R according to IEC 6085-) The visible laser beams are inactive during normal functioning. The installer can activate the visible lasers if needed. Caution! Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not look into the laser emitter or the visible red laser beams. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Only trained and qualified personnel may install and adjust the sensor. Test the good functioning of the installation before leaving the premises. The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 006/4/EC. Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer. The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor. INSTALLATION AND MAINTENANCE Avoid extreme vibrations. Do not cover the front screens. Avoid moving objects and light sources in the detection field. Avoid the presence of smoke and fog in the detection field. Avoid condensation. Avoid exposure to sudden and extreme temperature changes. Avoid direct exposure to high pressure cleaning. Do not use aggressive products to clean the front screens. Wipe the front screens regularly with a clean and damp cloth. Keep the sensor permanently powered in environments where the temperature can descend below -0 C.

DESCRIPTION 4 5 6 7 8 9 0. laser sweep emission. laser sweep reception. LED-signal (4) 4. screw for position lock () 5. connector 6. protection cover 7. visible laser beam () 8. notch for tilt angle adjustment () 9. adjustable bracket 0. cable conduit (4) LED-SIGNAL 4. Detection LED: relay - optional field. Detection LED: relay - safety field. Error LED 4. Power LED LED flashes quickly LED flashes DETECTION LEDs ERROR LED POWER LED detection error power LED flashes slowly no detection no error no power LED is off TIP! All LEDs can be switched off and on again by remote control: SYMBOLS CAT CAT According to Not according to Caution! Laser radiation Remote control sequence Possible remote control adjustments Factory values EN ISO 849-:008 Pl «d» / CAT

MOUNTING 0 cm Use the adhesive mounting template to position the sensor correctly. The grey area indicates the detection range. Drill 4 holes as indicated on the mounting template. Make a hole for the cable if possible. Pass the cable +/- 0 cm though the cable opening. If drilling an opening is not possible, use the cable conduits on the back side of the bracket. 4 5 6 Position the bracket and fasten the 4 screws firmly in order to avoid vibrations. Open the protection cover, plug the connector and position the cable in the slit. Close the protection cover and fasten it firmly. 7 8 Position the housing on the bracket. Turn the sensor until the two triangles are face to face. 4

WIRING GREEN BROWN WHITE YELLOW PINK VIOLET Power Supply + Power Supply - Relay - OPTIONAL FIELD Relay - SAFETY FIELD RED BLUE WHITE/RED WHITE/BLUE Test + Test - Not used Door control without test: connect red and blue wires to power supply (no polarity) POSITIONING Unlock the sensor and activate the visible laser beams. The visible laser beams indicate approximately the postion of curtain C and limit the angle of the detection field. The visible laser beams stay activated for 5 minutes or can be turned off the same way they were activated. C C C C4 Adjust the lateral position of the detection field. Adjust the tilt angle of the detection field with the hex key. Lock the position of the mounting bracket to avoid malfunctioning in case of extreme vibrations. CAT CAUTION! The distance between the inner curtains of the sensors must be max. 0 cm. 5

4 MOUNTING SIDE Stay outside of the detection field to avoid disturbances. Select the corresponding mounting side. The sensor learns its environment and automatically determines the detection field(s). Both RED LEDs flash slowly and the visible laser beams automatically light up during 0 seconds. CAT CAT left right left right centre with background The sensor memorizes the floor as reference point and signals a fault when its orientation is changed. without background No reference point, no signal. 5 SAFETY FIELD DIMENSIONS XGUARD-0 XGUARD-5 WIDTH HEIGHT no field MIN MAX MIN MAX - - 0.5 m 9.9 m no field 0.5 m 5.0 m 5.0 m - - 0.5 m 9.9 m 0.5 m 5.0 m 5.0 m EXAMPLE for a field width of 6. m IMPORTANT: Test the good functioning of the installation before leaving the premises. TEACH-IN Launch a teach-in after changing the sensor position or when new objects are added to or changed in the detection zone. The detection field should be free of snow buildups, heavy rain, snowfall, fog or other moving objects. Wait for the sensor to learn its environment or lock it by remote control. s max. 0 s During teach-in, the sensor learns its surroundings and adapts the detection field shape to these. Objects in the detection field will be cut out. 6

REMOTE CONTROL ADJUSTMENTS (OPTIONAL) C C C C4 DETECTION CURTAINS X X X X CURTAIN C C C C4 deactivate curtain on both fields activate curtain only on optional field activate curtain only on safety field activate curtain on both fields EX: C + C active on optional field only C + C4 active on safety field only C active on both fields C+C active on safety field only C4 deactivated All curtains active on both fields The distances between the curtains depend on the mounting height and side. When mounted on the left, the distance between the first and the last curtain is approximately 0 cm for every meter (mounting height). Example: at 5 m the distance is 50 cm. UNCOVERED ZONE 5 0 5 0 5 cm CAT CAT Increase in case of snow, dead leaves, etc. Immunity filter indoor outdoor low outdoor med outdoor high indoor outdoor low outdoor med LZR -I00 LZR -I0 CAT CAT CAT CAT outdoor high Increased immunity to rain, snow, fog... Increased sensitive (detection of black objects,...) MIN. OBJECT SIZE (approximate values) off 5 0 5 0 cm CAT CAT OUTPUT ACTIVATION DELAY (approximate values) The outputs are triggered after a constant detection time of x ms (ex. value = 00 ms). off 00 00 00 400 500 600 700 800 900 ms DETECTION FIELD REDIRECTION R optional optional or safety R safety safety OUTPUT CONFIGURATION R A - NO P - NC P - NC A - NO A = active P = passive R R R P - NC A - NO P - NC A - NO NO = normally open NC = normally closed FACTORY VALUES Rx = RELAY OUTPUT 7

OPTIONAL FIELD CONFIGURATIONS Make sure the white and yellow wires are connected to the corresponding inputs before you choose one of the following two configurations. virtual push button Install or virtual push buttons as activation zone(s) to open the door «manually». Apply the vitual push button sticker(s) within the opening field. Launch a PB teach-in to configure the detection zone(s). Launch a new PB teach-in each time the sensor position is changed or new objects are added to or changed in the detection zone. ATTENTION! This PB teach-in is different from the safety field teach-in. When the red LED flashes very slowly after seconds, hold your hand in front of the sticker to learn the detection zone. The green LED flashes x to confirm the selection. When the red LED flashes again, learn a second (max. ) detection zone or wait until the LED switches to green. s Change the output redirection if needed. In order to cancel the virtual push button function, you have to launch a new PB teach-in without any movement in the detection field. Only then the safety-during-opening can be configured. OR SAFETY-DURING-OPENING Configure a second detection field to secure the door during opening. After setting the mounting side, the safety and the optional field will have the same dimensions. Adjust the size of the field by remote control. Change the output redirection if needed. 8 WIDTH HEIGHT same as safety field no field XGUARD-0 XGUARD-5 - - 0.5 m 9.9 m same as 0.5 m 5.0 m safety field - - 0.5 m 9.9 m no field 0.5 m 5.0 m

HOW TO USE THE REMOTE CONTROL After unlocking, the red LED flashes and the sensor can be adjusted by remote control. If the red LED flashes quickly after unlocking, you need to enter an access code from to 4 digits. To end an adjustment session, always lock the sensor. Adjusting one or more parameters Checking a VALUE x 4 = field width: 4. m = field width is defined by teach-in RESTORING TO FACTORY VALUES teach-in SAVING AN ACCESS CODE The access code is recommended for sensors installed close to each other. DELETING AN ACCESS CODE Enter the existing code 0 minutes after last use, the sensor locks the access to the remote control session. Cut and restore power supply. The remote control session is accessible again during 0 minutes. x x = number of flashes = value of the parameter 9

TROUBLESHOOTING No blue LED There is no power. Check cable and connexion. The polarity of the power supply is inverted. Check the polarity of the power supply. Only the blue LED is on. The detection LED remains green. All LEDs have been deactivated by remote control. The test input is not connected. The detection field is too small or deactivated. The object size is too small. Activate the LEDs by remote control. Check wiring. The RED and BLUE cable have to be connected to the test input or the power supply. Check the size of the fields. Launch a teach-in. Decrease the min. object size. The detection LED remains red. Someone or something is in the detection field. Step out of the field and/or remove the any object(s) from the field. The orange LED is flashing and the detection LEDs are red. The field is touching the floor, the wall or the door, which leads to detection. No background (reference point) is found. Activate the red beams and check if the position of the sensor is correct. If not, adjust the hex screws. Verify the field size. Launch a teach-in. Check the position of the sensor. Check the mounting side setting. If there is no background, set the mounting side to value to 5. Launch a new teach-in. The sensor is masked. Verify and clean the front screens with a damp cloth. The orange LED is on. The power supply voltage is exceeding the acceptable limits. Check the power supply voltage. The sensor exceeds its temperature limits. Verify the outside temperature where the sensor is installed. Eventually protect the sensor from sunlight using a cover. Internal error Wait a few seconds. If the LED remains ON, reset the power supply. If the LED turns on again, replace the sensor. The sensor does not respond to the remote control. 0 minutes after last use of the remote control, the sensor locks the access to the remote control session. Cut and restore power supply. The remote control session is accessible again during 0 minutes. The batteries in the remote control are not installed properly or dead. Verify or replace the batteries. The remote control is badly pointed. Point the remote control towards the sensor, but with a slight angle. The RC should not be pointed in a right angle in front of the sensor. The sensor does not unlock. A reflective object is in close proximity to the sensor. You have to enter an access code or the wrong code was entered. Avoid highly reflective material in proximity to the sensor. Cut and restore power supply. No code is required to unlock during the first minute after powering. 0

TECHNICAL SPECIFICATIONS Technology: Detection mode: Max. detection range: Remission factor: Angular resolution: Min. detected object size (typ.): (in proportion to object distance) Testbody: Emission characteristics: IR laser: Red visible laser: Supply voltage: Power consumption: Peak current at power-on: Cable length: Response time: Output: Max. switching voltage: Max. switching current: Switching time: Output resistance: Voltage drop on output: Leakage current: Input: Max. contact voltage: Voltage threshold: Response time monitoring input: LED-signal: Dimensions: Material: Colour: Mounting angles on bracket: Rotation angles on bracket: Tilt angles on bracket: Protection degree: Temperature range: Humidity: Vibrations: Pollution on front screens: Expected lifetime: Norm conformity: laser scanner, time-of-flight measurement motion and presence (EN 45 Typ. E) XGUARD-0: 9.9 m x 9.9 m; XGUARD-5: 5.0 m x 5.0 m > % 0,56 XGUARD-0:, cm @ m ;,5 cm @ 5 m ; 7 cm @ 0 m XGUARD-5:, cm @ m ;,5 cm @ 5 m 700 mm x 00 mm x 00 mm (testbody A according to EN 445) wavelength 905 nm; max. output pulse power 75 W (CLASS ) wavelength 650 nm; max. output CW power mw (CLASS R) 0-5 V DC @ sensor side < 5 W.8 A (max. 80 ms @ 5 V) 0 m typ. 0 ms; max. 80 ms (+ output activation delay) electronic relays (galvanic isolated - polarity free) 5 V DC / 4 V AC 80 ma (resistive) t ON =5 ms; t OFF =5 ms typ 0 Ω < 0.7 V @ 0 ma < 0 µa optocouplers (galvanic isolated - polarity free) 0 V DC (over-voltage protected) Log. H: >8 V DC; Log. L: < V DC < 5 ms blue LED: power-on status orange LED: error status bi-coloured LEDs: detection/output status (green: no detection; red: detection) 5 mm (D) x 9 mm (W) x 70 mm (H) (mounting bracket + 4 mm) PC/ASA black or white -45, 0, 45-5 to +5 (lockable) - to + IP65-0 C to +60 C if powered; -0 C to +60 C unpowered 0-95 % non-condensing < G max. 0 %; homogenous 0 years 006/95/EC: LVD; 00/95/EC: RoHS; 004/08/EC: EMC; 006/4/EC: MD; EN 45:000 chapter 5...6, chapter 5.5. Safety device E; EN 978:009; EN ISO 849-:008 Pl d / CAT; EN 6059:00; IEC 6085-:007; EN 60950-:005; EN 6000-6-:005; EN 6000-6-:006; IEC 6496-:009; EN 6496-:008 ESPE Type ; EN 606:005 SIL ; DIN 8650-:00 Chapter 5.7.4 Specifications are subject to changes without prior notice. All values measured in specific conditions.

BEA Original instructions 4.8058 / V - 07. Please keep for further use Designed for colour printing FAAC S.p.A. - Via Calari, 0 40069 Zola Predosa - Italia - tel. +9 05 674 - fax. +9 05 75858 - www.faacgroup.com BEA hereby declares that the FAAC XGUARD-0/-5 is in conformity with the basic requirements and the other relevant provisions of the directives 006/95/EC, 00/95/EC, 004/08/EC and 006/4/EC. Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 0, 454 D-Essen Angleur, July 0 Pierre Gardier, Authorized representative and responsible for technical documentation For EC countries: according to the directive 00/96/EC for Waste Electrical and Electronic Equipment (WEEE) Manufactured by: BEA SA - LIEGE Science Park - Allée des Noisetiers 5-40 Angleur - Belgium - T + 4 66565 - F + 4 6858 - info@bea.be - www.bea.be