TROUBLESHOOTING VANGUARD

Similar documents
ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

MODELS: TJ45 TJ90 Operator s Manual

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

Installation Manual CARBONATOR With Plain-Water Booster

Product Manual. Scotsman. Models: 10150, and 10250

ICE/BEVERAGE DISPENSER

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

STARBUCKS UC100 PROGATE

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

Installation/Service Manual SENTRY III-A GLYCOL COOLING UNIT (R-134A REFRIGERANT)

Installation/Service Manual VANGUARD 245 POST-MIX OVERCOUNTER DISPENSER

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

Attached is Supplement three for service manual We suggest you file this with your Manual for reference.

Automatic Ice Maker. Service Manual VT ICEMAKER 15

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

INDEX. Granita Machine. Operation a nd Instruction Manual

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

Norcold Repair Guide for Ice Maker

owner s manual & parts list

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

Owner s Manual Window Air Conditioner

CP-2000-R-UC Owner s Manual

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

Installation Manual UNDER COUNTER GYLCOL REMOTE COOLING UNIT

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Glass Door Undercounter and Countertop Freezers

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

- 1 - Updated on 18 March, 2010

Room Air Conditioner Service and Parts Manual

TRAINING OUTLINE POST-MIX DAILY MAINTENANCE

Trouble Shooting Guide RAA, 1-phase (D3627)

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Trouble Shooting Guide PAA, 1-phase (D3731)

SCN60 Residential Nugget Ice Machine

R100 Oil-Less Refrigerant Recovery Unit

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

User Manual

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Trouble Shooting Guide PWA, 3-phase (D10571)

Trouble Shooting Guide FAA, 3-phase (D3631)

INSTALLATION & SERVICE BOOKLET. Juice Machine - Postmix JM 6 JM 7

- 1 - Updated on 18 March, 2010

ICE DISPENSER. Installation/Service Manual

Hoshizaki America, Inc.

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

T-Series Air Conditioner T15 Model

COUNTER ELECTRIC & NON- CARBONATED POST-MIX DISPENSERS

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

CABINET PARTS. For Models: GR2SHWXPQ00, GR2SHWXPT00, GR2SHWXPB00, GR2SHWXPS00, GR2SHWXPL00 (White) (Biscuit) (Black) (Stainless) (Stainless VCM)

T-Series Air Conditioner T53 Model

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

INSTALLATION AND SERVICE MANUAL FOR DELTA II REMOTE RECIRCULATING UNIT LANCER SERIES 9100

Drying Tumblers. Troubleshooting. 120 Pound Capacity 170 Pound Capacity. Refer to Page 5 for Model Numbers. Part No August 2007

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Part 3 Troubleshooting

INSTALLATION AND SERVICE MANUAL FOR THE SLIMLINE II, JUICE DISPENSER

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

VANGUARD 245 POST-MIX DISPENSER

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

INSTALLATION & SERVICE MANUAL QUANTUM SERIES

CABINET PARTS For Models: GT2SHMXMS04 (Stainless Steel)

CABINET PARTS For Model: KBLC36FMS02 (Stainless Steel)

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

CABINET PARTS. For Models: KBLC36FMS00 (Stainless Steel) 9 05 Litho In U.S.A. (kdj) Part No " BOTTOM MOUNT BUILT IN REFRIGERATOR

Instruction Manual Item No.: V~, 60Hz

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Installation Instructions

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Installation Guide. Tower and Draft Arm Dispenser System

TABLE OF CONTENTS FOR YOUR SAFETY

T-Series Air Conditioner T20 Model

NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-30A KM-35A KM-50A KM-75A MODEL SERVICE MANUAL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

2323 Drop-in Dispenser with MVU

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Transcription:

TROUBLESHOOTING VANGUARD IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring. WARNING: Disconnect electrical power to the Unit to prevent personal injury before attempting any electrical repairs to the internal components. If repairs are to be made to one of the syrup systems, disconnect syrup supply from the system, then bleed system pressure before proceeding. If repairs will be made to the CO 2 or the carbonated water system, disconnect electrical power to the carbonator, shut off CO 2 and plain water supplies, then bleed systems pressures before proceeding. TROUBLESHOOTING UNIT Trouble WATER-TO-SYRUP RATIO TOO LOW OR TOO HIGH. A. Dispensing valve syrup flow regulator not properly adjusted. A. Adjust Water-to-Syrup Ratio as ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT INCREASE TO DESIRED WATER-TO-SYRUP RATIO Syrup Tanks System. B. CO 2 gas pressure to syrup tanks insufficient to push syrup out of tank. Bag-In-Box System. CO 2 gas pressure to syrup pumps insufficient to operate pumps. A. No syrup supply. Syrup Tanks system. B. Syrup tanks CO 2 regulator out of adjustment. Syrup Bag-In-Box System. B. Adjust CO 2 regulator for syrup tanks as Adjust syrup pumps CO 2 regulator as A. Replenish syrup supply. B. Adjust CO 2 regulator for syrup tanks as Syrup pumps CO 2 regulator out of adjustment. C. Dispensing valve syrup flow control or syrup line restricted. F. Tapered gasket inside tube swivel nut connection distorted from being overtightened restricting syrup flow. 1 Adjust syrup pumps CO 2 regulator as C. Sanitize syrup system as D. Improper syrup Baume. D. Replace syrup supply. E. Inoperative dispensing valve syrup flow control. E. Repair dispensing valve syrup flow control. F. Replace tapered gasket. Make sure it is properly seated. TP00732

ADJUSTMENT OF DISPENSING VALVE SYRUP REGULATOR DOES NOT DECREASE TO DESIRED WATER-TO-SYRUP RATIO. CARBONATION TOO LOW. COMES OUT OF DISPENSING VALVE CLEAR BUT FOAMS IN CUP OR GLASS. A. Dirty or inoperative dispensing valve syrup flow control. A. Carbonator CO 2 regulator out of adjustment for existing water conditions or temperature. A. Disassemble and clean dispensing valve syrup flow regulator. A. Adjust carbonator CO 2 regulator (Reference manual provided with carbonator). B. Air in carbonated water tank. B. Vent air out of carbonated water tank by dispensing from dispensing valve to make carbonator water pump motor cycle on. C. Water, oil, or dirt, in CO 2 supply. A. Oil film or soap scum in cup or glass. B. Ice used for finished drink is subcooled. C. Remove contaminated CO 2. Clean CO 2 system (lines, regulator, etc.) using a mild detergent. Install a clean CO 2 supply. A. Use clean cups and glasses. B. Do not use ice directly from freezer. Allow ice to become wet before using. (Refer to following NOTE.) NOTE: Crushed ice also causes dispensing problems. When finished drink hits sharp edges of ice, carbonation is released from dispensed drink. PRODUCES FOAM AS IT LEAVES DISPENSING VALVE. A. Recovery rate of refrigeration unit exceeded, ice bank depleted. A. Allow ice bank to recover. CAUTION: The refrigeration assembly condenser coil must be cleaned every 30-days. Excessive accumulation of dust, lint, and grease on the condenser coil will restrict cooling air flow through coil and cause refrigeration system to overheat. Operating refrigeration system in an overheated condition will eventually lead to refrigeration compressor failure and will automatically void the factory warranty. B. Condenser coil plugged. B. Clean condenser coil as C. Carbonator CO 2 regulator pressure too high for existing water conditions or temperature. D. Dispensing valve restricted or dirty. C. Reduce carbonator CO 2 regulator pressure setting. D. Sanitize syrup system as TP00732 2

PRODUCES FOAM AS IT LEAVES DISPENSING VALVE. (cont d) NO PRODUCT DISPENSED FROM ALL DISPENSING VALVES. ONLY CARBONATED WATER DISPENSED. E. Tapered gasket inside carbonated water line swivel nut connector distorted restricting carbonated water flow. E. Replace tapered gasket. Make sure it is properly seated. F. Dirty water supply. F. Check water filter. Replace cartridge (see NOTE). NOTE: If water supply is dirty, be sure to flush lines and carbonator carbonated water tank completely. It may be necessary to remove lines to the carbonated water tank, invert the tank, then flush tank and all inlet lines to remove any foreign particles or dirt. A. Unit power switch (60-Hz Unit) in OFF position. B. Dispensing valves keyed lock-out switch in OFF (horizontal) position. A. Place power switch in ON position. B. Place dispensing valves keyed lock-out switch in ON (vertical) position. C. No electrical power to Unit. C. Plug in Unit power cord or check for blown power fuse or tripped circuit breaker. (Note: Fuse or circuit breaker are not part of Unit.) D. Disconnected dispensing valves power cord. E. Disconnected or broken wiring to dispensing valve. F. Inoperative 115 /24 VAC transformer. D. Connect dispensing valves power cord. E. Connect or replace wiring. F. Replace transformer. A. Out of syrup A. Replenish syrup supply as B. Inoperable dispensing valve. B. Repair dispensing valve. C. Dispensing valve syrup flow control not properly adjusted. D. Dispensing valve syrup flow control or syrup lines restricted. ONLY SYRUP DISPENSED. A. Plain water inlet supply line shutoff valve closed. C. Adjust dispensing valve syrup flow control (Water-to-Syrup Ratio ) as D. Sanitize syrup system as A. Open plain water inlet supply line shutoff valve. B. Carbonator not operating. B. Refer to manual provided with the carbonator. 3 TP00732

TROUBLESHOOTING REFRIGERATION SYSTEM COMPRESSOR DOES NOT A. Ice bank sufficient. A. Refrigeration not called for. OPERATE. B. Unit power cord unplugged, Unit power switch (60-Hz Unit) in OFF position, or drop-in refrigeration assembly power cord unplugged. B. Plug in power cord or place Unit power switch in ON position. COMPRESSOR DOES NOT OPERATE. (cont d) COMPRESSOR WILL NOT STOP AFTER SUFFICIENT ICE BANK IS PRODUCED. C. No power source (blown fuse or tripped circuit breaker). D. Inoperative Unit power switch (60-Hz Unit) or Unit power cord unplugged. C. Replace fuse or reset circuit breaker. (Note: Fuse or circuit breaker are not part of Unit.) D. Replace power switch or plug Unit power cord into electrical outlet. E. Low voltage. E. Voltage must be at least 103 volts at compressor terminal when compressor is trying to start. F. Loose, disconnected, or broken wiring. G. Overload protector cut out; overheated compressor. Condenser fan motor not operating as required. F. Tighten connections or replace broken wiring. G. Compressor will cool enough to restart. Do not overdraw cooling capacity of Unit. Refer to CONDENSER FAN MOTOR NOT OPERATING in this section. H. Inoperative overload protector H. Replace inoperative part. or start relay. I. Inoperative ice bank control. I. Replace ice bank control. J. Inoperative compressor. J. Call Service Person. A. Ice bank control cap tube kinked or broken. B. Ice bank control stuck in closed position. A. Replace ice bank control. B. Replace ice bank control. TP00732 4

COMPRESSOR OPERATES CONTINUOUSLY BUT DOES NOT FORM SUFFICIENT ICE BANK. CONDENSER FAN MOTOR NOT OPERATING. AGITATOR MOTOR NOT OPERATING. AGITATOR MOTOR NOT OPERATING. (cont d) A. Cooling capacity is exceeded by over-drawing. B. Unit located in excessively hot area or air circulation through condenser coil is restricted. A. Reduce amount of drinks drawn per given time. B. Relocate Unit or check and if necessary, clean condenser coil filter as NOTE: Ice bank freezes from bottom of evaporator upward. A refrigerant leak or insufficient charge might show an ice bank at bottom and not at the top of evaporator. NOTE: If overload protector cuts out compressor, condenser fan motor will continue to operate; otherwise; troubleshooting condenser fan motor problems is same as for COMPRESSOR DOES NOT OPERATE paragraph plus the following: A. Jumper cord loose or disconnected from motor or terminal block. Broken wire in cord. B. Inoperative condenser fan motor. A. Unit power cord or refrigeration assembly power cord unplugged. B. No power source (blown fuse or tripped circuit breaker). A. Tighten connections or replace cord. B. Replace condenser fan motor. A. Connect power cord(s). B. Replace fuse or reset circuit breaker. (Note: Fuse or circuit breaker are not part of Unit.) C. Agitator motor propeller C. Remove obstruction. obstructed. D. Low voltage. D. Voltage must be at least 103 VAC at compressor terminals when compressor is trying to start. E. Loose, disconnected, or broken wiring. E. Tighten connections or replace broken wiring. F. Inoperative agitator motor. F. Replace agitator motor. 5 TP00732

TROUBLESHOOTING AURORA TOWER IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to carbonated water system, disconnect electrical power to Cooling Unit, shut off plain water and CO 2 supplies, and relieve the carbonated water system pressure before proceeding. If repairs are to be made to syrup system, remove quick disconnects from applicable syrup tank, then relieve the system pressure before proceeding. If repairs are to be made to CO 2 system, stop dispensing, shut off CO 2 supply, then relieve the system pressure before proceeding. If repairs are to be made to an existing Remote Condensing unit, disconnect the power to the condensing unit before proceeding TROUBLE COMMON TO ALL MODELS Trouble WATER TO SYRUP RATIO TOO LOW OR TOO HIGH. A. Dispensing valve syrup flow regulator not properly adjusted. B. CO 2 gas pressure to soft drink tanks insufficient to push syrup out of tanks. A. Adjust Water to Syrup Ratio as B. Adjust soft drink tanks CO 2 regulator or check CO 2 supply and replenish. ADJUSTMENT OF A. No syrup supply. A. Replenish syrup supply. DISPENSING VALVE SYRUP FLOW REGULATOR DOES B. Quick disconnects not secure B. Secure quick disconnects. NOT INCREASE TO DESIRED on soft drink tanks. WATER TO SYRUP RATIO C. Soft drink tanks CO 2 regulator out of adjustment. C. Adjust soft drink tanks CO 2 regulator. ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT DECREASE TO DESIRED WATER TO SYRUP RATIO. D. Dispensing valve syrup flow regulator, soft drink tank quick disconnect, or syrup line restricted. D. Sanitize syrup system. E. Improper Baume of syrup. E. Replace syrup supply. F. Dirty or inoperative piston or spring in dispensing valve syrup flow regulator. G. Tapered nylon washer inside tube swivel nut connector distorted from being overtightened. A. Dirty or inoperative piston or spring in dispensing valve syrup flow regulator. F. Disassemble and clean dispensing valve syrup flow regulator. G. Replace nylon washer and make sure it seats properly. A. Disassemble and clean dispensing VALVE SYRUP FLOW REGULATOR. TP00732 6

CARBONATION TOO LOW. COMES OUT OF DISPENSING VALVE CLEAR BUT FOAMS IN CUP OR GLASS. PRODUCES FOAM AS IT LEAVES DISPENSING VALVE. A. Carbonator CO 2 regulator out of adjustment for existing water conditions. A. Adjust carbonator CO 2 regulator. (Refer to manual provided with carbonator). B. Air in carbonator tank. B. Vent air out of carbonator tank through relief valve. Dispense carbonated water to make carbonator pump cycle on. C. Water, oil, or dirt, in CO 2 supply. A. Oil film or soap scum in cup or glass. B. Ice used for finished drink is sub cooled. C. Remove contaminated CO 2, Clean CO 2 system (lines, regulators, etc.) using a mild detergent. Install a clean CO 2 supply. A. Use clean cups and glasses. B. Do not use ice directly from freezer. Allow ice to become wet before using. (Refer to following NOTE.) NOTE: Crushed ice causes dispensing problems. When finished drink hits sharp edges of ice, carbonation is released from dispensed drink. A. Recovery rate of refrigeration unit or cold plate exceeded. B. Carbonator CO 2 regulator pressure too high for existing water conditions or temperature. C. Syrup over carbonated with CO 2 as indicated by bubbles in inlet syrup lines leading to unit. D. Dispensing valve syrup flow regulator restricted or dirty. E. Tapered nylon washer inside carbonated water line swivel nut connector distorted restricting carbonated water flow. A. Allow refrigeration unit or cold plate to recover. (Check cold plate for ice supply). B. Reduce carbonator CO 2 regulator pressure setting. C. Remove soft drink tanks quick disconnects. Relieve tank CO 2 pressure, shake tank vigorously, then relieve tank CO 2 pressure as many times as necessary to remove carbonation. D. Sanitize syrup system. E. Replace nylon washer. Make sure it is properly seated. F. Dirty water supply. F. Check water filter. Replace cartridge. (see NOTE). NOTE: If water supply is dirty, be sure to flush lines and carbonator completely. It may be necessary to remove lines to carbonator tank, invert tank, and flush tank and all inlet lines to remove any foreign particles or dirt. 7 TP00732

ONLY CARBONATED WATER DISPENSED. A. Quick disconnects not secure on soft drink tanks. A. Secure quick disconnects on soft drink tanks. B. Out of syrup. B. Replenish syrup supply. C. Soft drink tanks CO 2 regulator not properly adjusted. C. Adjust soft drink tanks CO 2 regulator. D. Inoperable dispensing valve. D. Repair dispensing valve. E. Dispensing valve syrup flow regulator not properly adjusted. F. Dispensing valve syrup flow regulator, soft drink tank quick disconnect, or syrup lines restricted. ONLY SYRUP DISPENSED. A. Water inlet supply line shutoff valve closed. B. Carbonator power cord unplugged from electrical outlet. C. Carbonator CO 2 regulator not properly adjusted. TROUBLESHOOTING UNIT WITH ELECTRIC DISPENSING VALVES NO PRODUCT DISPENSED. A. Dispense stop key lock switch turned to OFF position. B. No electrical power to transformer. C. Dispensing valve wiring harness power cord disconnected from transformer outlet. E. Adjust Water to Syrup Ratio of dispensed product. F. Sanitize syrup system. A. Open water inlet supply line shutoff valve. B. Plug carbonator power cord into electrical outlet. C. Adjust carbonator CO 2 regulator (Refer to manual provided with carbonator). A. Turn key lock switch to ON position. B. Plug transformer power cord into electrical outlet. C. Connect dispensing valve wiring harness power cord to transformer. D. Inoperative transformer. D. Replace transformer. NO PRODUCT DISPENSED A. Broken or disconnected wiring. A. Repair or connect wiring. FROM ONE DISPENSING VALVE. B. Inoperative solenoid coil. B. Replace solenoid coil. C. Inoperative electronic Portion Control. C. Replace Portion Control. TP00732 8

IMPORTANT: TROUBLESHOOTING ICE DISPENSERS WARNING: Disconnect electrical power to unit to prevent personnel injury before attempting any internal maintenance. Only qualified personnel should service internal components or electrical wiring. TROUBLESHOOTING ICE DISPENSER Trouble BLOWN FUSE OR CIRCUIT BREAKER. GATE DOES NOT OPEN. AGITATOR DOES NOT TURN. A. Short circuit in wiring. A. Find electrical short, then repair wire. B. Defective gate solenoid. B. Replace gate solenoid. A. No power. A. Install power to unit. B. Defective dispensing switch. B. Replace defective switch. GATE DOES NOT OPEN OR IS SLUGGISH. AGITATOR TURNS C. Bent depressor lever (does not actuate switch). A. Excessive pressure against gate slide. B. Defective gate solenoid. C. Shape (bend) lever so it will actuate switch A. Adjust gate slide to reduced pressure B. Replace defective solenoid. GATE OPENS. AGITATOR DOES NOT TURN. ICE DISPENSES CONTINUOUSLY. C. Weak gate spring. C. Replace gate spring. A. Ice solidified in hopper. A. Separate ice junks in hopper (break apart) B. Defective agitator motor. B. Replace defective agitator motor. C. Defective capacitor (TJ90). C. Replace Defective capacitor. A. Stuck or bent depressor lever (does not release switch). A. Shape (bend) lever so it will release actuated switch B. Defective dispensing switch. B. Replace defective switch. C. Improper switch installation. C. Adjust switch. SLUSHY ICE. WATER IN A. Blocked drain. A. Clear drain of obstruction. HOPPER. B. Unit not level. B. Adjust unit using carpenters level. C. Poor ice quality due to water C. Replace water filters. quality or icemaker problem. D. Improper use of flake ice. D. Use cubed ice in this dispenser. 9 TP00732

IMPORTANT: TROUBLESHOOTING PROGATE W/PORTION CONTROL ICE DRINK WARNING: Disconnect electrical power to unit to prevent personnel injury before attempting any internal maintenance. Only qualified personnel should service internal components or electrical wiring. If repairs are to be made to CO 2, syrup, or water systems, shut off CO 2 and plain water supplies, discount carbonator power cord, disconnect syrup tanks, and bleed systems pressures before proceeding TROUBLESHOOTING POST MIX SYSTEM Trouble WATER TO SYRUP RATIO TOO LOW OR TOO HIGH. ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW CONTROL DOES NOT INCREASE TO DESIRED WATER TO SYRUP RATIO. A. Dispensing valve syrup flow control not properly adjusted. B. CO 2 gas pressure to syrup tanks insufficient to push syrup out of tanks. A. No syrup supply. B. Syrup tank quick disconnects not secure. C. Syrup tanks secondary CO 2 regulator out of adjustment. A. Adjust Water to Syrup Ratio as B. Adjust secondary CO 2 regulator for syrup tanks as A. Replenish syrup supply as instructed B. Secure quick disconnects. C. Adjust syrup tanks secondary CO 2 regulator as D. Dispensing valve syrup flow control, syrup tank quick disconnect, or syrup line restricted. D. Sanitize syrup system as ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW CONTROL DOES NOT DECREASE TO DESIRED WATER TO SYRUP RATIO. CARBONATION TO LOW. E. Improper Baume of syrup. E. Replace syrup supply. F. Dirty or inoperative dispensing valve syrup flow control. G. Tapered nylon washer inside tube swivel nut connection distorted from being overtightened restricting syrup flow. A. Dirty or inoperative dispensing valve syrup flow control. A. Carbonator primary CO 2 regulator out of adjustment for existing water conditions or temperature. F. Disassemble and clean dispensing valve syrup flow control. G. Replace nylon washer. Make sure it seats properly. A. Disassemble and clean dispensing valve syrup flow control. A. Adjust carbonator primary CO 2 regulator (Reference manual provided with carbonator). B. Air in carbonator tank. B. Vent air out of carbonator tank through relief valve. Activate dispensing valve No. 1 to make carbonator pump cycle on. TP00732 10

CARBONATION TO LOW. (con t) COMES OUT OF DISPENSING VALVE CLEAR BUT FOAMS IN CUP. PRODUCES FOAM AS PRODUCT LEAVES DISPENSING VALVE. C. Water, oil, or dirt, in CO 2 supply. A. Ice used for finished drink is subcooled. B. Insufficient ice supply in dispenser ice bin. C. Remove contaminated CO 2. Clean CO 2 system (lines, regulator, etc.) using a mild detergent. Install a clean CO 2 supply. A. If using purchased ice allow ice to melt slightly before using. B. Replenish ice supply as C. Oil film or soap scum in cups C. Use clean cups. A. Carbonator primary CO 2 regulator CO 2 pressure set to high for existing water conditions or temperature. B. Syrup over carbonated with CO 2 as indicated by bubbles in inlet syrup lines leading to dispenser. C. Dispensing valve restricted or dirty. D. Tapered nylon washer inside carbonated water line swivel nut connector distorted restricting carbonated water flow. A. Reduce carbonator CO 2 regulator setting. B. Remove syrup tanks quick disconnects. Relieve tank CO 2 pressure, shake tank vigorously, then relieve tank CO 2 pressure as many times as necessary to remove over carbonation. C. Sanitize syrup system as D. Replace nylon washer. Make sure it is properly seated. E. Dirty water supply. E. Check water filter. Replace cartridge. Note: If water supply is dirty, be sure to flush lines and carbonator completely. It may be necessary to remove lines to carbonator tank, invert tank and flush tank and all inlet lines to remove any foreign particles or dirt. NO PRODUCT DISPENSED FROM ALL DISPENSING A. Dispenser rocker type power switch in OFF position. A. place power switch in ON position. VALVES. B. No electrical power to dispenser. B. Plug in dispenser power cord, or check fuse or circuit breaker. C. Disconnected or broken wiring C. Connect or replace wiring. to dispensing valves. D. Loose ground connection. D. Have ground connection repaired. E. Inoperative dispenser E. Have transformer replaced. transformer NO PRODUCT DISPENSED A. Broken or disconnected wiring. A. Connect wiring or have repaired. FROM ONE DISPENSING B. Inoperative dispensing valve. B. Have dispensing valve repaired. VALVE. C. Inoperative portion control. C. Replace portion control cover. 11 TP00732

A. Quick disconnects not secure on syrup tanks. ONLY CARBONATED WATER DISPENSED. A. Secure quick disconnects on syrup tanks. B. Out of syrup. B. Replenish syrup supply as C. CO 2 regulator for syrup tanks not properly adjusted. C. Adjust syrup tank CO 2 regulator as D. Inoperable dispensing valve. D. Have dispensing valve repaired. E. Dispensing valve syrup flow control not properly adjusted. F. Dispensing valve syrup flow control, syrup tank quick disconnect, or syrup lines restricted. ONLY SYRUP DISPENSED. A. Plain water inlet supply line shutoff valve closed. B. Carbonator power cord unplugged from electrical outlet. C. Carbonator CO 2 regulator not properly adjusted. DISPENSING VALVE WILL NOT DISPENSE ANY A. Portion control not properly adjusted. PORTION CONTROL SIZE DRINK. B. Portion control cover electrical wiring disconnected. E. Adjust dispensing valve syrup flow control (Water to Syrup Ratio ) as F. Sanitize syrup system as A. Open plain water inlet supply line shutoff valve. B. Plug carbonator power cord into electrical outlet. C. Adjust carbonator CO 2 regulator (Reference manual provided with carbonator). A. Adjust all portion sizes on dispensing valve as B. Connect portion control cover electrical wiring. C. Inoperable portion control. C. Replace portion control cover. NO RESPONSE FROM ONE OF THE PORTION CONTROL SWITCHES OR THE CANCEL/POUR SWITCH. A. Inoperable portion control. A. Replace portion control cover. TROUBLESHOOTING ICE DISPENSING SYSTEM Trouble NO ICE DISPENSED A. Ice bin cover not in place. A. Install ice bin cover. B. Insufficient ice supply in ice bin. B. Replenish ice supply as C. Ice in ice bin bridged (stuck C. Gently tap on ice to break it loose. together). D. No electrical power to dispenser. D. Plug in dispenser power cord, or check fuse or circuit breaker. E. Insufficient or no CO2 supply E. Restore CO2 supply to dispenser. to dispenser. F. Inoperative ice portion F. Replace ice portion controller. controller. G. Inoperative ice agitator motor. G. Replace ice agitator motor. H. Inoperative gate cylinder. H. Replace gate cylinder. I. Inoperative gate solenoid I. Replace gate solenoid. TP00732 12