ozti PASTA COOKER Model : OMFG 4090 S & OMFG 8090 S USER AND TECHNICAL MANUAL GAS TYPE/PRESSURE Natural gas Propan gas

Similar documents
USER AND TECHNICAL MANUAL

ozti DISHWASHERS USER S MANUAL PRODUCTION YEAR: SERIAL NO :

User Manual. 600mm, 700mm & 900mm Gas Cooktops Model No. CF6GS, CF6GW, CF7GS, CF9GS

GAS STOVE TOP.

Group. Virtus Group GmbH Hüserstraße Hamm / Germany. Virtus s.r.l. via Milano 95/e Casteggio (PV) / Italy

INSTRUCTION AND MAINTENANCE MANUAL

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

INSTRUCTION MANUAL GAS COOKTOPS IL**604, IL**775, IL**905 (** = BV, WV and SS models)

Installation and Operating Instructions

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18

Contents. 1. Instructions for safety and use 20

FLAME HEATER PYRAMID CLFH-10SS OPERATION INSTRUCTIONS

USER MANUAL. 60cm, 3 burners, Hob AKC 630

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

Gas Fire Patio Heater Q9

Table Top Patio Heater

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

Contents authorised persons

USER MANUAL Gas Countertop Charbroilers

Gas Fire Patio Heater Lhotse-817

F900 SERIES BOILING PAN G9781. User, installation and servicing instructions. Read these instructions before use T REV.

installation & operating instructions

installation and operating instructions OG63XA Cooktop

USER MANUAL AKC cm 4 Burners, Stainless Steel Hob

BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set.

BUILT-IN / TABLE TOP HOB GAS COOKER USER MANUAL

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Proline GAS HOB Model TCG40IX Instruction Book

Porter & Charles OPERATION MANUAL. Gas Cooktop CG60S, CG76S, CG90S, CG60W, CG90W

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCES. This equipment is design engineered for commercial use only

Owner s Guide Installation & Operation

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200

PC 640 GB. Built-in cooking tables 60 Instructions for installation and use

TERRACE AND PATIO HEATER

Owner s Guide Installation & Operation

TERRACE AND PATIO HEATER

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

PRO SERIES GAS FRYERS OWNER S MANUAL

INSTRUCTION MANUAL BUILT-IN HOBS CIR900X

PATIO HEATER OPERATING & MAINTENANCE INSTRUCTIONS MODEL No. PHT3. Stainless

GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

USER MANUAL ART cm Deluxe Gas Hob

FRANKE DESIGNER GAS COOKTOP 90CM

OG7302 Salamander Grill

GAS FR25 IR FRYERS. Grande Carte SPECIFICATIONS CONSTRUCTEUR. Part A: Technical characteristics Part B: Technical instructions for installation

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

Dashley Outdoor Fire Table

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

QUANTUM. gas heater. makes life easier. New fold up design. 3 Ceremic plates. Piezo electric ignition. Model: W KW

CBO-750 HYBRID-R OVEN Instructions Manual

GC2-43N GC2-43P GC2-48N GC2-48P GC1-28N GC1-28P

ASSEMBLY INSTRUCTIONS HOODED GAS GRILL Model: UC375SBPSS

Dovre 250 Cast Iron Gas Stove

BUILT-IN GAS HOB THE BEAUTY OF SIMPLICITY USER MANUAL BATTERY IGNITION. Model:

PARAGON GAS FRYER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL : PDGF/PDGFP

COMMERCIAL TYPE FILTERED COFFEE MACHINE USER MANUAL

Gas burners Induction. Ceramic Hob Plancha GAS CHARGRIL ELECTRIC CHARGRILL LAG 010 CKG LAE 010 CKG. Hob top option

SHAHI TANDOOR GAS- FIRED (NAT & LPG) From The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

COMMERCIAL ELECTRICAL AND SAND COFFEE COOKER USER MANUAL

Pizza Oven with Stand

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

Built-in Gas Hob. Important - Please read these instructions fully before using. Operating Instructions -Please keep for future reference

INSTALLATION & OPERATION MANUAL

Area Heater AH100 Series

Gas Countertop Fryer lb Model lb Model NG and LPG Models

Flame Heater PH08 SERIES

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT

STAR-MAX PROPANE GAS GRIDDLE

Stone Hearth Pizza Dome Oven

Installation, Operating and Servicing Instructions

INSTRUCTIONS FOR HOBS PISL1CZI PISL20ZI PISL40ZI PISL40Z* PISL4CZI PISL904CZI PISL1004CZI PISL1163CZI PISF4CZI PISF904CZI PISF1004CZI PISF1163CZI

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

Installation and Operating Instructions

Affix Stamp Dear Customer,

LP GAS PIZZA OVEN USER MANUAL

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592

CYLINDER NOT INCLUDED

Stoneridge Fire Pit High Dining Table Assembly Instruction

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

Gas Fire Patio Heater Kongur-500

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

OPERATING, INSTALLATION, SERVICE & PARTS MANUAL FOR MEDIUM DUTY GAS CHAR BROILERS MGB-A SERIES

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

EGT7828CK EGT7838CK EGT9229CK EGT9239CK EGT9239CKB. User Manual. EN Gas Cooktop. Fj oms113"01u. TH 1cnL.ls:nou01rns. VI Bếp gas âm

Viking Installation Guide

These instructions are for your safety. Please read them thoroughly before use and retain them for future reference

GAS COOKER GAS OVEN SERIES. Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Transcription:

ozti PASTA COOKER Model : OMFG 4090 S & OMFG 8090 S USER AND TECHNICAL MANUAL GAS TYPE/PRESSURE Natural gas Propan gas PRODUCTION YEAR: SERIAL NR: MANUFACTURER : ÖZTİRYAKİLER MADENİ EŞYA SAN. VE TİC A.Ş. Adress: Cumhuriyet Mh. Eski Hadımköy Yolu No:37- Büyükçekmece Istanbul/TURKEY Phone: 0090 212 886 78 00 (8 Lines) Fax : 0090 212 886 66 29 Web : www.oztiryakiler.com e-mail: export@oztiryakiler.com.tr PUBLISHED ON : : 07.12.2006 VERSION. 06 1/19

TABLE OF CONTENTS PAGE TOPICS 1 2 3 4 5 COVER PAGE TABLE OF CONTENTS INTRODUCTION TECHNICAL SPECIFICATIONS (TECHNICAL MANUEL) MAIN DIMENSIONS 6 SAMPLE DATA PLATE AND WARNING NOTICES 7 TRANSPORTING AND MOVING 8-9-10 INSTALLATION OF THE APPLIANCE 11 SETTING AIR ADJUSTER AND MINIMUM GAS RATE 12 POSSIBLE FAILURES AND WAYS OF ELIMINATING 13-14-15-16 OPERATION OF THE APPLIANCE (USER MANUEL) 17 18 19 CLEAN-UP AND MAINTENANCE SUMMARY OF SAFETY DETAILS TERMS OF WARRANTY 2/19

INTRODUCTION Dear User, Thank you for purchasing our appliance and for your reliance upon our company. Our appliances are used in professional kitchens in 90countries. Our appliances are produced in compliance with Gas Appliances Directive. Important notice: Please read this user s manual in order to achieve the desired performance in line with your expectations and to use your appliance for long years. Please take the warnings mentioned above into consideration before calling for service... Please read and ensure that your operation person also reads this user s manual carefully before putting into service and using the appliance. If the appliance is operated other way than written in this manual, the appliance will not be covered by the warranty. The manual contains information about installation, usage and maintenance of our product you purchased should be read carefully. Please ensure that gas connection to the appliance must be installed by qualified technician according to national regulations. If you are confused or you don t have enough information please get in touch with authorized service by phone. Please keep in mind that, if the service technician is delayed at your site, related expenses and delay costs will be charged to you on hourly basis. We hope that you will get the best performance from our product 3/19

TECHNICAL SPECIFICATIONS MODEL NAME APPLIED STANDARD ΣQn (HEAT INPUT H i ) (Btu/h) BURNERS ΣCONSUMPTION GAS CONNECTION GAS PRESSURE BURNER NOZZLES DIAMETER PILOT NOZZLE ( only for oven) PRIMARY AIR DISTANCE (X) (fixed by the manufacturer see fig.6) TYPE OF FLUE AIR REQUIREMENT FOR COMBUSTION+VENTILATION (at least 2 m³/kw in one hour) ANSI Z83.11a-2004, CSA 1.8a-2004; Addenda A:2004, Issue 2002/07/01 Natural gas:1,615 m³/h Propan:1,482 kg/h Natural gas 7 WC Propan gas 11 WC Natural gas: Ø 2,25 mm Propan gas: Ø 1,45 mm Open OMFG 4090 S 61416 2 1/2 ISO 7-1:1982 Ø0.35mm Not designed for compulsory connection to any extraction system min. 30 m³/h Open OMFG 8090 S ANSI Z83.11a-2004, CSA 1.8a-2004; Addenda A:2004, Issue 2002/07/01 122832 4 Natural gas:3,23 m³/h Propan:2,96 kg/h 3/4 ISO 7-1:1982 Natural gas 7 WC Propan gas 11 WC Natural gas: Ø 2,25 mm Propan gas: Ø 1,45 mm Ø0,35mm Not designed for compulsory connection to any extraction system min. 60 m³/h The data plate is located behind of front panel and back side of appliance. 4/19

MAIN DIMENSIONS AND WARNING NOTICES MODEL OMFG 4090 S HOT SURFACE 2,25 mm SAMPLE LABEL Figure 1 : Main dimensions 5/19

SAMPLE DATA PLATE & WARNING NOTICES 2,25 mm Figure 2: Sample data plate These appliance can only be used in destiny country(s) indicated on the data plate by codes and on the applicabel gases on correct pressure! This appliances shall be installed in conformity with the current regulations and used only in a well ventillated location. Consult the instruction before installing and using this appliance 6/19

TRANSPORTING AND MOVING Figure 3: Transportation CHANGING THE LOCATION; Appliances installed by an authorized technician CANNOT BE MOVED ELSEWHERE, CONNECTION HOSES CANNOT BE EXTENDED OR REPLACED except by an authorized technician. The appliances can be moved with supplementary vehicles like fork lift Feets of the fork lift should be placed under the appliances. During the transportation, the machine should be moved slowly and the appliances should be fixed on the palette or supported in order to prevent jolt. Do not hit or drop the appliance when moving. 7/19

INSTALLATION OF THE APPLIANCE If this appliances located near to any wall, separation, kitchen furniture, decorative coating etc. the distance in between should be at least 20 cm. And if those are coated with fireproof heat insulating material, the distance should be also at least 10 cm. It is strongly recommended that local fire safety protection instructions are observed. All of the items mentioned below in connection with the installation of the appliances should be carried out by authorized technician. All of the gas supply connections of the appliances should be comply with ISO 7-1:1982 8/19

INSTALLATION OF THE APPLIANCES Remove the appliance from the packaging. Remove all plastic adhesive film from parts before installing the appliance. Clean parts thoroughly to remove all adhesive residue.(do not use abrasive substances) GAS LEAKAGE CHECKING Bebre putting into service, ensure that there are no gas leakages from the gas system of appliance.use brushing soapy water over the unions and couplings; leaks are detected by the appearance of bubbles. WARNING: Never use open flames to detect gas leakages. GAS PRESSURE CHECKING Measure gas pressure by means of a water type pressure gauge (e.g. a U-type pressure gauge with 0.1 mbar minumum resolution). Remove the pressure gauge test point screw A on the inlet gas pipe (fig.4) Connect the U-type pressure gauge. Read the gas pressure. Note: If the pressure value is not within the specified limits (see technical specifications ), do not use the appliance under any circumtances.inform the gas supplying company immediately. After pressure cheching, remove the pressure gauge and tighten the screw.with applicabel seals. 9/19

INSTALLATION OF THE APPLIANCES gas inlet Figure 4: Gas pressure checking Nominal power of the device cannot be changed upon customers request. Any modificationsmade on valves and injectors are very dangerous and, leaves the device out of warranty coverage. Don t use not originally produced spare parts.installing spare parts not supplied by our company, will leave the device out of warranty coverage. 10/19

SETTING AIR ADJUSTER AND MINIMUM GAS RATE There are adjustable primary air unit and minimum gas rate srew on every gas value THE ADJUSTABLE PART OF THE PRIMARY AIR UNIT, AND MINUMUM GAS ADJUSTER FIXED (B)AND SIGNED. PLEASE KEEP THIS SETTINGS DURING OPERATION. NOT NECESSARY FOR THESE MODELS Figure 5: minumum gas flow adjuster screw (B)fixed and signed on valve 11/19

POSSIBLE FAILURES AND WAYS OF ELIMINATING NO 1 2 3 4 5 POSSIBLE FAILURES Appliance valve is open, but no gas is running. Appliance valve is open, gas is running, but burner does not work Ignition is OK in the oven the valve in pilot position, the flame goes out. The temperature of the oven can not be controlled. Main valve is open, appliance valve is closed,smelling gas METHOD OF ELIMINATION 1.Check the main valve that is probably or closed. 2.Main valve or appliance valve can be damaged,call the service. 1.Check the pilot burner position of the oven. 2.In case of thermocouple failure call service 1.The flame control system work. 2.Call the service 1.Call the service. does not 1.You have to control all gas connections by gas leakage checkhing. 2.In case of any leakage call the service 12/19

OPERATION OF THE APPLIANCE A. GENERAL 1. Pasta cooker is used to cook pasta at tourism facilities, fast food restaurants, sandwich bars, coffee houses, bakeries, restaurants, homes etc. 2. Clean the instrument exterior and the water container before use for the first time using a cloth wetted but not soaked with luke warm soap water. 3. Place the instrument under an aspirator with filter connected to an air ventilation system. 4. Add water or replace it completely at certain intervals depending on the frequency of use. Please read related FOOD LEGISLATION on the subject. NOTE : Please do not use other than its intended purpose. The instrument must be used by a person who knows the safety and technical conditions of use and who has read the manual for use. B. USE OF THE INSTRUMENT ATTENTION 1. Put water of the amount specified in the table for technical specifications based on the model of the instrument. * the level of water must not be below the specified level. Water level below that does not provide optimum cooking. * The level of water must not be above the maximum level specified. There is a risk of over boiling of water at levels above that. * Do not operate when there is no water in it. 2. IGNITING PILOT BURNER Turn safety valve to pilot position (*) (figure 8) and hold it pressed for awhile,(at initial use wait for 20-25 second, allawing the air in the gas pipes to exhaust and gas to flow inside) allowing gas to come at the pilot. Then light the pilot using igniter by types with igniter and using another saurce of fire (like lighting stripe or match) by types without igniter. Pilot flame can easly be monitored.(figure 6 D)Due to the flame control set up, the valve is pressed further (maximum 20 seconds) to ensure the continuity of the pilot fire.if pilot flame does not go off after the safety valve is released, please stop pressing it. 3. IGNITING MAIN BURNER(S) : Turn safety valve max. or min. Position (figure 9) The main burners will be light on during this position. 4. After the safety valve turned max. Position the water will start to heat up. 5. After the tempereture of the water reaches the reguired level of temperature, pasta s may be put into the basket and dipped into the cooker. 13/19

OPERATION OF THE APPLIANCE 6. After the completion of the cooking cycle,(approx 4-11 min) the basket is hanged above the water level for dripping. 7. After dripping, the baskets are taken out of the pasta cooker and pasta s out of the baskets and served. Cooking process can be continued like this. 8. For continuous use (depending on the material to be cooked and freguency of processing)water is exchanged at certain intervals or water maybe added. (figure 6 B) 9. After cooking is finished, water is emptied trough the tap underneath.water will be hot there fore almost care is reguired during the process of discharging of the water in pasta cooker. (figure 6 E) 10. Turning off the pasta cooker If the pasta cooker will bnot be operate for a short period of time, turn safety gas valve to the pilot position (*)(figure 8), that only the pilot burner will operate. In order to turn the pasta cooker off entirely, turn safety valve to off position.(figure 7) Turning off network gas connections or gas valve is recommendet to avoid danger. FLAME CONTROL DEVICE: If for any reason the pilot flame goers out, when the instrument is still on, the system will shut itself down automatically. Turning off supply of gas may take up to 60 seconds. 14/19

OPERATION OF THE APPLIANCE 900 SERİE A B C D A- FILLING FRESH WATER TAP B- FILLING FRESH WATER CONTROL KNOB C- SAFETY VALVE CONTROL KNOB D-FLAME MONITOR PANEL E-WATER DISCHERGE TAP CONTROL KNOB FIGURE 6 E 15/19

OPERATION OF THE APPLIANCE 900 SERİE FIGURE 7 SAFETY GAS VALVE OFF POSITION FIGURE 8 SAFETY GAS VALVE ON POSITION FIGURE 9 SAFETY GAS VALVE ON MAX POSITION FIGURE 10 SAFETY GAS VALVE ON MIN POSITION FLAME CONTROL SETUP FOR OVEN If accidentally pilot flame goes out for any reason, when the appliances is on, the system will close itself automatically to avoid dangeraus gas accumulotion in the oven.you can try to restart the system again after more than 60 seconds. 16/19

CLEAN-UP AND MAINTENANCE 1. CLEAN-UP: Before first use of the appliances, and before and after subsequent uses, complete outer surface with a sponge and liquid detergent. Do not use CHEMICAL CLEANING AGENTS like hydrochloric acid etc. during cleaning. 2. MAINTENANCE (Can be done by authorized service personel) Periodic maintenance should be carried out by technical service personnel. Depending on using frequency, maintenance period should be at least 6 months. Expenses of maintenance carried out by our authorized service personnel must be met by the customer even within the warranty period. Please follow the instructions below: a. Injectors: Injector opening should be completely clean. c. Pilot: Pilot flame should be proper and touching the thermocouples. d. Gas burner: Gas passing pipes and openings should be clean and not clogged. e. The parts dismantled during the clean-up should be installed back by the technical service personnel and after the installation gas leakage should be checked with soap bubble method. LIFE OF USE Appliancess life of use is 10 year if it is used under recommended conditions. 17/19

SUMMARY OF SAFETY DETAILS If the appliances is operated from LPG gas cylinder, the distance between the appliances and gas cylinder should be at least 50 cm. Any kind of flammable solid and liquid material (cloths, alcohol and derivatives, petrochemical products, wooden and plastic materials, cutting blocks, curtains etc.) should never be hold near the appliances. Do not clean up the appliances with pressurized water This appliances is designed for industrial use and should only be operated by trained person according to this manual. The appliances should only be repaired by the manufacturer or authorized service personel In case of fire or flame in the area where the open every window and door appliances is operated, act without panic, close all gas valves, turn off the power switches and use a fire extinguisher. Never use water to extinguish the fire, water will cause the fire to spread more faster. 18/19

TERMS OF WARRANTY 1- Documents without sales date, factory and sales company approval on, are not valid. In order to benefit from the warranty, warranty document should be presented. 2- If the appliance is installed and operated following the instructions in the installation, maintenance and user's manual, it is warranted for failures sourcing from materials and workmanship. 3- The failures within the scope of warranty, how and where these will be eliminated, and the way and place of maintenance is determined by... 4- The warranty is only valid provided that the warranty terms and the instructions in the installation, maintenance and user's manual are fully complied with. The warranty is only valid for the warranted appliance, and no other right or compensation for some other thing may be claimed. 5- If the information about the kind and the type of the appliance, serial numbers printed on the warranty document are scraped, rubbed or changed, then the warranty is not valid. 6- The warranty covers only maintenance and repairing of material or workmanship failure within the valid warranty period. Failures and parts within the scope of the warranty are repaired and replaced without any charge. Replaced parts belong to... 7- The failures occurring in the appliance may only be handled by service personnel authorized by... If people who are not authorized handle the appliance, it will not be covered by the warranty. 8- Installation should be carried out by authorized service personnel and the service should be informed about the location change of the appliance. 9- When any failure occurs during operation, authorized service dealer should be contacted. 10- Warranty does not cover failures and damages resulting from loading, unloading and shipping, which are outside the responsibility of... Similarly, failures and damages resulting from external factors are not covered. 19/19