FULL BLEED APPLICATION SHOT RENDERING
ANATOMY SLEEK & STRONG A perfectly square aluminum extrusion made of 60% recycled material provides durable functionality in an elegant compact form. CORE CAPACITY Integral 0-0V dimming driver down to 0% or % standard. Additional options include Lutron, DMX, and DALI control protocols. Integral IOTA slim W emergency battery pack provides an easy solution for egress compliance. POWERFUL PERFORMANCE High performance Nichia 80+ CRI LEDs provide an optimal light source for tailored lighting design. Dual board option for maximized light output and high ceiling applications. SEAMLESS INTEGRATION The variety of recessed mounting options promote coalescing of light and space. ELEMENTS Elements is a simplified product line comprised of 4, 8, and nominal length fixtures that can be joined to create continuous rows. 4.68 INTEGRATIONS PROPRIETARY OPTICS Tech lens technology cleanly combines optical diffusion and high performance reflector design to deliver beautifully refined light with uncompromised performance. Integrations is a comprehensive product line comprised of exact length fixtures, continuous rows, and patterns comprised of 90 illuminated corners. 4 8 R For rows over (R) fixtures will be shipped in sections. Joining hardware for field installation is provided. INTERGRATIONS+ Integrations+ is a completely custom ordering process allowing unique modifications and non-90 transitions through collaboration with Design Assist.
MOUNTING MOUNTING OPTIONS (G) Flush Gyp/Hard Lid (XP) Trim Flange (T) T-bar 9/6 (X) T-bar 5/6 (N) T-bar 9/6 Slot STANDARD PATTERNS CORNER DETAIL Welded corner (LCW) Wall to ceiling (LWW) Wall to ceiling (LW) Wall only Joining pins (LC) Ceiling only (UWW) Wall to wall to wall (UWC) Wall to ceiling to wall 4 (UW) Wall only (UC) Ceiling only (RW) Wall only 4 (RC) Ceiling only (CP) Custom pattern
ELEMENTS Ordering Code G5 Project Info Date Type Quantity Series: G5 Length: Nominal 4 Nominal 8 Nominal Nominal length 6 and over Specify length in 4 increments Output: LED standard output (5 W/ft) LED high output (0 W/ft) Dual LED standard output (0 W/ft) Dual LED high output (0 W/ft) 4 8 R LS LH DS DH Dimming: Standard 0-0 dimming Dimming to %, see technical section Lutron Eco H series (LDE) Emergency: Emergency - battery () ILB-SL-CP (00lm for 90min) Options: New York City code D D E N LED CCT: 000K 500K 4000K 0 5 40 Voltage: Universal 0V - 77V 47V U Direct Optics: Tech TM Mounting: Flush gyp / mud over flange regressed gyp / mud over flange / trim flange T-bar 9/6 T-bar 5/6 T-bar 9/6 slot 6 on center standard T-bar 9/6 6 on center slot T-bar 9/6 Housing slightly regressed G RG XP T X N T6 N6 Finish: Only on XP, T6, N6 mounting types a lightanium Satin white Satin black T W B Damp Location Rated
INTEGRATIONS Ordering Code G5 Project Info Date Type Quantity Series: G5 Length or Pattern Type: Exact Length Specify in inches to the nearest /8th e.g. M80.5 Pattern options: Specify in inches to the nearest /8th See Standard Patterns for details. L Shape flat L Wall to ceiling L Wall to adjacent wall e.g. PL0.5 x 4.00 U Shape flat U Wall to ceiling to wall U Wall to wall to wall e.g. PU0.5 x 4.00 x 0.5 Rectangle / Square flat e.g. PR0.5 x 4.00 Output: LED standard output (5 W/ft) LED high output (0 W/ft) Dual LED standard output (0 W/ft) Dual LED high output (0 W/ft) LED custom output LED CCT: 000K 500K 4000K Voltage: Universal 0V - 77V 47V Direct Optics: Tech TM M PLL PLCW PLWW PU PUCW PUWW PR LS LH DS DH C 0 5 40 U Finish: a lightanium Satin white Satin black Other Specify RAL# Dimming: Standard 0-0 dimming Dimming to %, see technical section Lutron Eco H series (LDE) Other dimming specify model/series Emergency: Emergency - circuited Emergency - battery ILB-SL-CP (00lm for 90min) Specify desired quantity of battery s Not available on fixtures < 4 length Sensors: Occupancy sensor Wattstopper FS-05 (Ø ) Photocell/Daylight sensor Wattstopper FD-0 wired for daylight harvesting. Requires 0-0V dimming Occupancy & Daylight sensor Options: Multi-circuit Submit multi-circuiting requirements New York City code Wet location Contact Design Assist MR6 LED Enter quantity. Submit MR6 addendum. MR6 Halogen Enter quantity. Submit MR6 addendum. 90+ CRI T W B O D D D EC E O P OP M N Q MRL MRH CRI Mounting: Flush gyp / mud over flange regressed gyp / mud over flange / trim flange T-bar 9/6 T-bar 5/6 T-bar 9/6 slot 6 on center standard T-bar 9/6 6 on center slot T-bar 9/6 Housing slightly regressed G RG XP T X N T6 N6 Damp Location Rated
TECHNICAL DATA LINEAR DIMENSIONS Elements - 4, 8, and nominal length individual fixtures that can be joined to create continuous row lengths. Integrations - Exact lengths to the nearest /8th of an inch available as individual fixtures or joined to create continuous row lengths, minimum fixture length is inches. Patterns comprised of 90 degree precisely welded fully illuminated corners provide a multitude of geometric options and architectural transitions. Integrations+ - Contact Design Assist for modifications to product not detailed within Elements or Integrations specification sheets. OPTICS Tech patented high efficacy extruded diffuse acrylic lens technology with integrated opaque white reflector delivers superior lumen output with optimal uniform lens surface luminance for direct distribution. LED LIGHT SOURCE Custom manufactured linear board array uses high performance Nichia LED in combination with a performance driven heat sink technology. Tested in accordance with LM79 and LM-80; L70>60,0000hr; operated at reduced output for high efficacy and lumen maintenance. 000K, 500K, and 4000K with 80+ CRI standard; other color temperatures and 90+ CRI available upon request, contact factory. LED color variation maintained at a -step MacAdam ellipse (SDCM x). LEDs are available in Low, Standard, and High outputs. Refer to photometry for delivered lumens. Custom output available in the range of 5% - 5% of high output, contact factory. LED DIMMING DRIVER Factory tuned constant current electronic 0-0V control dimming driver is standard. Specification grade dimming down to 0% standard. Contact factory if % dimming is required. Driver life of 50,000 hrs with ambient operating temperature range of -0 C to 50 C, maximum case temperature of 75 C. Electrical specifications at maximum driver load: PF >0.9, THD <0%, >85% Efficiency. Other available drivers include Lutron Eco-system H-series (LDE): Hi-lume % LED dimming driver with Soft On, Fade to Black; and DMX and DALI protocol drivers. Other Lutron and specialty drivers available, contact factory. EMERGENCY Factory installed integrated fixture LED emergency battery pack for both normal and emergency operation. Unit contains long-life Ni-Cad recyclable battery, 4 hour charger, and converter circuit. Test switch and charge indicator provided. Test button to be remote located by others in accordance with local code. Emergency mode provides constant power to a nominal W LED load for a period of 90 minutes, delivering 00 lumens of unwavering illumination throughout the full 90 minute emergency duration. Unless otherwise specified, the emergency battery pack will illuminate one foot end of the fixture in the direct portion of the fixture. Emergency circuiting provided as a separate circuit from normal power circuit according to NEC requirements, specify circuit length and location. CONTROLS Low-profile integral occupancy and daylight sensors are available to deliver high performance control in an architecturally pleasing package. Integral occupancy sensor - the sleek Wattstopper FS-05 modular plug-in system utilizes a RJ45 connector, low voltage cord, and power pack. Automatic on/off passive infrared (PIR) occupancy sensing control covers a range of 00 square feet for a specified 0 second to 0 minute time delay with an optional ambient daylight sensing function to hold lights off when specified adequate daylight level is sensed. Factory default time delay of 0 minutes and 0fc light level. Settings can be adjusted at the factory or easily in the field. Integral daylight sensor - the sophisticated Wattstopper FD-0 is a low voltage controller using 0-0VDC input to automatically dim the electric lighting system based on daylight contribution in a 70 field of view to achieve a target illuminance using a sliding setpoint algorithm. This single zone closed loop daylight harvesting control system utilizes a RJ45 connector, low voltage cord, and power pack. One () LSR-0-S setup remote control to adjust target let levels is provided per order. Combined occupancy and daylight sensing is achieved using both the FS-05 and FD-0 for more versatile control functionality including automatic on/off occupancy and daylight dimming response. Other manufacturer controls may be available for product integration, contact factory. MOUNTING Common recessed mounting options available. Contact factory for applications regarding modified recessed mounting conditions. Flush Gypsum Flange. Raw aluminum flange is attached to blocking (by others), then mudded over and/or painted by installing contractor to provide a flangeless fixture appearance in recessed ceiling/wall applications. Trim Flange. / wide visible powder coated flange, specify finish requirement. Fixture is mounted to structure using threaded rod (by others) or ceiling tie wires (provided). Use of a-clamp secures fixture trim and housing around ceiling/wall material. Use for any gypsum or hard ceiling/wall that requires a minimal flange covering the ceiling cut-out edge. T-Bar/Grid Ceiling. 9/6 or 5/6 standard T-Bar or 9/6 slot ceiling. Raw aluminum flange sits on T-Bar and is concealed from view. 4 Armstrong Techzone / USG Logix or other 4 Utility Systems. 9/6 or 5/6 standard T-Bar or 9/6 slot ceiling. Suitable for use in 4 on-center standard or slot T-Bar systems. Approximate wide visible side flanges create a seamless 4 slot condition, specify finish requirement. STRUCTURE Robust, high quality 60% recycled aluminum extruded housing. 0.040 thick aluminum internal gear trays. Flat or flanged aluminum end caps. Aluminum joiner brackets. 4 lbs/ft approximate fixture weight. FINISH Electrostatically applied powder coat finish. Standard finish options include alightanium, satin white, and satin black. Other colors and custom finish options available, specify RAL# or contact factory regarding custom finish requirement.
TECHNICAL DATA LISTING UL/CUL rated for Damp Locations. Tested in accordance with UL 598 and certified to CEC/CSA C., NEC, ANSI/NFPA 70, and NOM-00-SEDE. UL Wet location label available. Complies with UL definition of wet locations to prevent accumulation of water on live parts, electrical components, or conductor not identified for use in contact with water through the provision of weep holes. Neoprene gaskets provided at end caps to prevent ingress of liquids. For continuous fixture runs, wet location joiner blocks are provided. Waterproof connector to be provided by others. Installing contractor responsible for properly sealing and waterproofing all field drilled and power feed locations. WARRANTY Limited defect-free manufactured equipment warranty provided under normal use and proper storage for a period of one () year. LED products (LED boards and drivers) will be covered for a period of five (5) years. Wet location fixtures are not recommended for extreme wet weather conditions and must be installed according to factory drawings; there is a modified warranty for LED components installed in applications not in accordance with factory recommendations/drawings. Please refer to full terms and conditions on our website. MR6 MODULES Heavy-duty, milled aluminum plate module contains recessed cutouts for flush mounting of LED module (supplied) or halogen MR6 lamp (by others). Specification and layout of modules and lamping per MR6 SPECIFICATION ADDENDUM