These instructions detail procedures to follow in order to avoid damage to equipment.

Similar documents
D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Addressable NAC Output Module D327A

FMR Installation Instructions. Addressable Fire System Controller

F220-B6PS/M. Installation Guide. Addressable Detector Bases

D7052. Installation Instructions Multiplex Dual Input Module

D7044. Installation Instructions Multiplex Single Input Module

D250A/D253/D261AW/D280A/D290 Series

Multiplex Eight Input Remote Modules

D7053. Installation Instructions Multiplex Input/Output Module

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Notification Appliance Circuit Module

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

DS7465i. Installation Instructions. Input/Output Module

Control Relay Modules

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

SIGA-CC1 Single Input Signal Module Installation Sheet

Booster Power Supply Manual

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Print Specification. Publication. Instructions. Specific requirements. General requirements

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

FireNET Plus Wiring Instructions

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Remote NAC Power Supply D7038

PSN-1000 & PSN 1000(E) Installation Manual

Fire Control/Communicator

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Public Safety DAS Annunciator Panel

GEMC-FW-SLC FIRE SIGNALING LINE CIRCUIT MODULE INSTALLATION INSTRUCTIONS

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Filtrex A Smoke Detector for Difficult Environments

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Signature Series Auto-Sync Output Module (CC1S)

IDP-Zone-6 Six Zone Interface Module

SECTION FIRE ALARM SYSTEMS

June 10, 2002 DF C S2424

Installation Instructions Model HZM

MMF Six Zone Interface Module

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

AL600ULADA. NAC Power Extender. Installation Guide

Operation and Installation Guide. Zone Expansion Module D8125

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Duct and Rough Service Carbon Monoxide Sensor

MR-2602 Two Zone Fire Alarm Control Panel

/5121/5122 TrueAlert Power Supply Installation Instructions

TrueAlarm Analog Sensing

DCP-FRCME - FAST RESPONSE CONTACT MODULE

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

good things in small packages

Operation and Installation Guide. Fire Alarm Control Panel

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

AU MX Digital Loop Card Installation Instructions

AL800ULADA. NAC Power Extender. Installation Guide

30.45 Electric Release PDRP-2001

Addressable Detectors & Bases

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

1400 Direct Wire Ionization Smoke Detector

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Installation Guide. Control/Communicator

TECHNICAL DATA OBSOLETE

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

LifeAlarm Fire Alarm Control Panels

D2071A. Operation & Installation Guide Fire Alarm Control Panel

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

Independent Zone Control (I.Z.C.)

ECC-50/100(E) Emergency Command Center

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

Fire Alarm Control/Communicator

Instruction Manual EVA-S6 Base

Conventional Fire Alarm Systems

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

July 14, 1999 DF C-100.

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model 17A00 Expansion Enclosure

D2071A Fire Control/Communicator Digital Alarm Communicator Transmitter (DACT)

Battery charger modules

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

Duct smoke housings, 4-wire D341/D341P and D342/D342P

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

LifeAlarm Fire Alarm Controls

Interface and EOL Modules 8

Multiple Input and Output Modules

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

MBCE-110/230FR Flame Sensor Module

SP-1000X. Panic Device Power Controller Installation Guide. Rev

INSTALLATION MANUAL: IDC-6 INITIATING DEVICE CIRCUIT EXPANDER

Duct smoke housing, 2-wire D340/D340P

Transcription:

D326A, D334A, D339A Point Contact Modules Installation Guide 1.0 Notice These instructions are for the installation of the D326A, D334A and D339A Point Contact Modules in an analog system controlled by a Fire Alarm Control Panel (FACP) using an advanced digital communications protocol. These modules provide a Class B initiating device circuit. They allow the panel to supervise their circuits for contact closure, contact opening, or wiring fault. The D326A, D334A and D339A modules are compatible with the D8024, D9024, D10024 Radionics Analog Fire Alarm Control Panels (FACP). Installing detection devices in an analog system consists of: Addressing the Devices. Wiring the Modules to the FACP. Wiring the Devices to the Module. Installing the Module in a Back Box. These instructions detail procedures to follow in order to avoid damage to equipment. 2.0 Installation Standards Install, test, and maintain these devices according to these instructions, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these instructions may result in failure of the device to initiate a proper response. Radionics is not responsible for improperly installed, tested or maintained devices. 3.0 Point Contact Modules Table 1: D326A, D334A, D339A Specifications Model # Description Voltage Range Idle Current Polling Current Alarm Current D326A 4 module on plate 17-41VDC, 24VDC Nominal 350µA 22mA ± 20% 28mA D334A remote module 17-41VDC, 24VDC Nominal 350µA 22mA ± 20% 28mA D339A remote module 17-41VDC, 24VDC Nominal 350µA 22mA ± 20% 28mA 4.0 LED Functions All three point contact modules have an LED that flashes green when the module is active, indicating that they have been correctly programmed and learned into the system. When a device is polled, the LED flashes once every 18 seconds. The LED will flash red when an input circuit is faulted. 5.0 Device Descriptions The D326A, D334A and D339A are single ID addressable device input modules. They provide a point for connection of a two-wire dry contact closure device input loop with the FACP. All are UL Listed for fire alarm initiating device and supervisory device applications. The address is set by programming an EEPROM microchip. The D326A module mounts on a plate that attaches directly to a UL Listed four-inch square back box having a minimum depth of 2-1/8 inches. A cover plate leaves the status LED visible. The D326A has a response time of 2 seconds. The D334A module is mounted in a plastic enclosure that attaches to the inside of a back box and is normally out of view. The D334A has a response time of 2 seconds. The D339A is part of the D325A Manual Fire Alarm Box. The D339A will allow a Fire Alarm Control Panel (FACP) to recognize an activation within 2 seconds. This module can be mounted into any gang back box. 37098D 12/98 Page 1 1998 Radionics, Inc. All rights reserved.

6.0 Addressing the Devices The device address must be set before the cover plate is attached. When using the back box enclosure, the address must be set before the module is placed in the enclosure. Each detector device or module in an analog system has a specific address that is set by programming an EEPROM microchip. Each polling circuit can support up to 126 addresses. It is not necessary to wire the devices in any particular order in the circuit. 6.1. Using the D5070 Analog Device Programmer The D5070 Analog Device Programmer must be used when programming addresses on the D326A, D334A and the D339A. Make sure the battery is connected prior to programming. Module Programming Jack Receptacle Twist on sensor head here Non-polarized plug To Remote Programming Jack Programming Buttons Radionics Display Modular Programming Adapter Figure 1: D5070 Analog Device Programmer and Module Programming Adapter D5070 Programming Buttons See Table 2 for a description of the three programming buttons on the D5070 Analog Device Programmer. Table 2: D5070 Programming Buttons Programming Button Left Gray Button Right Gray Button Red Button Description Power On. Automatically reads the address of a sensor. Subsequent operations will advance the device by ten. Power Off. Advances the device address by one. Stores the displayed address to the device, and is used to read analog levels. Polarity must be observed for proper address setting. 1998 Radionics, Inc. All rights reserved. Page 2 37098D 12/98

Setting the Address The following steps explain how to set an address using the D5070 Analog Device Programmer. See Figures 1-3 for more details. 1. To program the address on the D326A or D334A, insert the non-polarized plug on the Programming Adapter into the address programming pins on the D326A/D334A module. Plug the remote programming jack on the Programming Adapter into the remote programming jack receptacle on the D5070 Analog Device Programmer (See Figure 2). 2. Press the left gray button to turn the D5070 on. A battery check message will appear followed by the device s address. 3. Set the required address by pressing the left and right gray buttons until the desired address is reached (the display will show three red flashing dots if the address being programmed is different than the device s current address). 4. When the desired address is displayed, press the red button to store that address. The three red dots on the display will no longer be present. 5. To program the address on the D339A, the black and red wires that extend from the Programming Adapter must be wired to the terminal strip on the D339A module (See Figure 3). Plug the remote programming jack on the Programming Adapter into the remote programming jack receptacle on the D5070 Analog Device Programmer, and then follow steps 2 through 4 as described above. Figure 2: D326A/D334A Programming Connections Figure 3: D339A Programming Connections 37098D 12/98 Page 3 1998 Radionics, Inc. All rights reserved.

Reading Analog Value Install the module and power the D5070 up as previously described. Press the red button. An A will appear on the display followed by the analog value. This value will be continuously updated for 3 minutes or until the unit is turned off. See Table 3 for device address information. Table 3: Address Information Data Table Device Standard Pre-Alarm Threshold Standard Fire Threshold Just Calibrated Range Normal Reading Fault Input Fire D322A Heat Detector 113 F (45 C) 142 F (61 C) 136 F - 149 F (58 C - 65 C) D323A Photoelectric Detector 2.5 % 3%.1%.5% - 4% D324A Ion Detector 1% 1% 1% N/A D325A Manual Station 16 64 D326A Point Contact Module 16 44 64 D327A NAC Output Module 16 44 D328A Addressable Relay Module 16 D334A Point Contact Module 16 44 64 D339A Point Contact Module 16 44 64 Display Messages See Table 4 for a description of the display messages that may appear on the D5070 Analog Device Programmer. Table 4: Display Message Descriptions Display Message bat E0 E1 E2 E3 E4 E5 Description Battery Check. Displayed upon power up, and when the battery is low. A low battery is good for up to 3,000 address setting operations. Address past 127 will not be recognized by the panel. Attempting to program an address with no device connected. Cannot find the device after power up or replace device. Replace detector. Cannot find the device to program. Device read error. E6 7.0 Wiring the Modules to the FACP Replace detector. Analog Polling Circuits connect to the FACP over two-wire cable. The circuit resists interference from most types of EMI and RF generated noise, and no special wiring requirements are required other than attention to wire gauge. Under extremely noisy conditions, use twisted pair wire to reduce interference. If EMI is a problem, use shielded cable, being careful to ground the drain wire to the E terminal on the FACP Control Module. See the Control Panel Installation Guide for details. 7.1 Circuit Configuration Polling circuits connect to the FACP in either a Class A or a Class B circuit. T tapping is acceptable in Class B circuits only. For specific Class A and B circuit installation requirements, see NFPA 72. See the Installation Instruction for the FACP for instruction on connecting the polling circuit to the panel. 1998 Radionics, Inc. All rights reserved. Page 4 37098D 12/98

7.2 Device to Circuit Wiring Wire the D326A, D334A or the D339A in the polling circuit by connecting the Data/Power Positive (+) and Data/Power Common (-) terminals as shown in Figure 3. Disconnect all power to the FACP before installing this module. 7.3 Circuit Length Data Circuit Length is the distance over the circuit wire from the connection at the FACP to the most distant device and back to the FACP. Data Circuit Length must include the distance to any device connected to the circuit in a T tap. The screw terminals will accept 14 AWG (1.5 mm) but this will reduce the allowable length of the circuit. Figure 4: Point Contact Module to Circuit Wiring Table 4: Polling Circuit Length/Wire Gauge Polling Circuit Length Up to 4,000 ft. (1,219 m) Up to 7,200 ft. (2,195 m) Up to 6,800 ft. (2,073 m) Wire Gauge 18 (1.1 mm) 16 (1.3 mm) 14 (1.5 mm) 37098D 12/98 Page 5 1998 Radionics, Inc. All rights reserved.

Data/power Positive Return Earth Ground for Shield Cable Drain Data/power Common Return Data/power Positive Out + - E + - LOOP 2 + - E + - LOOP 1 Data/power Common Out D9067 POLLING CIRCUIT MODULE D9067 POLLING CIRCUIT MODULE Figure 5: E Terminal Location 7.4 Shielded Cable If shielded cable is used, and the cable is of good quality, then it should not have a significant effect on the polling circuit length. Good quality shielded cable will allow 1µfd of capacitance, 1mH of inductance and 50 ohms resistance. Connect the drain wire for shielded cable to the E terminal of the Data Terminal Block at the FACP. See Figure 5 for details. Unless the shielded cable is properly grounded, it may aggravate rather than eliminate noise problems. The shield must be reconnected each time the cable is cut to install a device. 8.0 Wiring Devices to the Point Contact Module (Initiating Device Circuit) The Initiating Device Circuit may use any number of UL-listed Normally Open (N/O) contact closure devices. Do not mix fire alarm initiating and supervisory devices on the same module. Device circuit wiring shall not exceed 50 ohms. Install contact closure devices according to the manufacturer s installation instructions. All wiring shown is supervised and inherently power-limited. 10K ohm UL Listed EOL Device (P/N: 0400-01044) Figure 6: NFPA 72 Style B Initiating Device Circuit 1998 Radionics, Inc. All rights reserved. Page 6 37098D 12/98

9.0 Installing Point Contact Modules in the Back Box Wiring for the D326A, D334A and D339A is identical. Refer to the following sections for specific installation instructions regarding the D326A, D334A and the D339A. 9.1 D326A Installation The D326A module mounts on a plate which attaches to a 4-inch square electrical box at least 2-1/8 deep. A cover plate conceals the address programming pins and leaves the LED visible. After wiring the module to the FACP and connecting the initiating device circuitry as shown in Figure 6, attach the Point Contact Module plate to the back box as shown in Figure 7. Install the cover plate. 9.2 D334A Installation Figure 7: Mounting Plate Installation for the D326A Set the D334A address before wiring the module and installing it in the back box. Once the D334A is installed in the back box, setting or changing the address will involve removing the device and removing and opening the module case. The D334A mounts in a single gang back box behind the device and is secured with a Velcro patch. A retrofit installation in a manual pull station is a typical application of the D334A. Connect the module to the FACP and to the initiating device as shown in Figure 9. Set the module in the enclosure back and snap the enclosure top closed over it. Attach the enclosure to the Velcro patch in the back. See Figure 8 for more details. Install the initiating device. Distribuidor Autorizado: Segurança Industrial Equipamentos Fone/Fax: (41) 4063-9687 ou 3287-1364 www.segind.com.br - cml@segind.com.br 37098D 12/98 Page 7 1998 Radionics, Inc. All rights reserved.

9.3 D339A Installation The D339A can mount in any single gang back box, and it is part of the D325A Manual Fire Alarm Pull Box. The D339A attaches to the back box with a Velcro patch. See Figure 8 for back box installation details. Figure 8: Point Contact Module Installation Remove AC and standby power from the FACP before connecting or disconnecting any devices. 6 1 Initiating Device Circuit Data/Power Positive In Data/Power Common Out Data/Power Positive Out Figure 9: D334A Wiring Data/Power Common In Distribuição: Segurança Industrial Equipamentos Fone/Fax: (41) 4063-9687 cml@segind.com.br - segindbr@hotmail.com www.segind.com.br