Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

Similar documents
Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Halo. Thermostatic heads with built-in sensor

V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS

Installation and operating instructions

thermostatic inserts for radiators with integrated valves

Art-Line. Absolutely Brilliant Temperature control was never so good

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

Catalogue e and d price list

Data sheet Thermostatic sensors type RA 2000

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Thermostatic Actuators

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

IMI Heimeier Kit Hydroca ble

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Multilux 4-Eclipse-Set

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

EMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.

Thermostatic valve bodies

Flush individual room control for floor heating systems

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Standard. thermostatic valve body without presetting

Three-way reversing valve

Radiator Valve Program

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Regulux. Radiator lockshield with drain-off facility. To be precise.

Control valves for floor heating systems. Floor Heating Manifolds

Thermostatic valves with radiator connection systems

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Automatic balancing valves ASV-PV (new generation) DN 32-50

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Installation and User Guide eco Intelligent Radiator Thermostat

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

thermostatic valve body with stepless precision presetting

living connect, Electronic Radiator Thermostat

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Thermostatic Radiator Valves (Caleffi)

RA2000 Commercial TRVs

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Thermostatic head with wax sensor

Product overview All you need to know about choosing valves and thermostats

caleffi hydronic valves page 1 of 12

Valid from

TRV 300 RADIATOR VALVES

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

SOLUTIONS GUIDE. For total efficiency

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Mikrotherm. Manual Radiator Valves With presetting

Installation and User Guide living connect Electronic Radiator Thermostat

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

Danfoss Eco Electronic radiator thermostat

RA15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Heating Emitters. Find the right radiator for each room. Radiators Towel Warmers Towel Warmer Valves 295

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Product Announcement

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Radiators: indirect energy metering and components

TS RD 7761 RD, 7761 RD

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Thermostatic valve bodies

Energy Saving Series RADICAL

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

Radical CPD BIM.

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

VOGEL&NOOT. Convectors & heating panels. heatingthroughinnovation.

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

STRAIGHT AND ANGLED THERMOSTATIC VALVES

RA2000 Thermostatic Radiator Valves

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

2 DESCRIPTION OF SYSTEM COMPONENTS

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

Self-learning Room Temperature Controller

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Transcription:

Thermostatic heads for all thermostatic valve bodies and radiators with integrated valves To be precise.

Thermostatic heads Table of contents Page Thermostatic heads Construction Application 4 Function 4 Operation 5 Thermostatic head K with built-in sensor standard 6 with zero position 6 with anti-theft ring (public building applications) 6 with anti-theft device comprised of two screws 6 for public indoor swimming pools and medical spas 6 with anti-theft ring and staggered setting range (public building applications) 6 Thermostatic head K with remote sensor standard 7 with zero position 7 with anti-theft ring (public building applications) 7 with anti-theft device comprised of two screws 7 for public indoor swimming pools and medical spas 7 Thermostatic head DX 8 Thermostatic head D 9 Thermostatic head B public building model 10 Thermostatic head F remote dial with built-in sensor 11 remote dial with remote sensor (central adjuster) 11 Thermostatic head VDX for radiators with integrated valves 12 Thermostatic head WK angle form for radiators with integrated valves 1 Thermostatic head VK with clamp connecting for radiators with integrated valves 14 standard 14 with zero position 14 with anti-theft device comprised of two screws 14 Thermostatic heads with direct connection for valve bodies from other manufacturers for Danfoss RA thermostatic valve bodies 15 for Danfoss RAV thermostatic valve bodies 15 for Danfoss RAVL thermostatic valve bodies 15 for Danfoss RTD thermostatic valve bodies 15 for Vaillant thermostatic valve bodies 15 for Herz M 28 x 1,5 thermostatic valve bodies 15 for TA M 28 x 1,5 thermostatic valve bodies 15 Accessories 16 Dimensional data sheets 17 19 List of the CEN certified thermostatic heads and valve bodies 20 2

Thermostatic heads HEIMEIER thermostatic heads are control units for controlling the temperature in individual rooms and are available in various models. For models with a built-in sensor (see illustration), the actuator, controller, and sensor form a single unit which is the thermostat. This is filled with an incompressible liquid and has high pressure power. For thermostatic heads with remote sensors, the main part of the temperature-sensitive liquid is not found in the head itself, but rather in the remote sensor. From there the liquid acts on the corrugated pipe in the head via the capillary tube. For remote dials, the thermostatic head is separated from the valve body and acts on the corrugated pipe in the valve connecting piece via the capillary tube. Central adjusters are remote dials with additional remote sensors. The groove on the face of the thermostatic heads K, VK, WK and F serves to take up color clips or specially printed partner clips. Construction Thermolux K thermostatic valve Corrugated pipe Markings designed for the visually impaired Liquid-filled thermostat with high pressure power and precision control Safety spring Hidden stops for variable limiting and blocking CEN certified and tested in accordance with DIN EN 215 With 2 clips for marking, limiting or blocking Symbols for basic setting and nighttime set back Brief data including the most important settings Rotation direction indicator Markings designed for the visually impaired Heimeier connection technology (locking ring M 0 x 1.5)

Thermostatic heads Application HEIMEIER thermostatic heads are used to control the temperature of individual rooms using, for example, heaters, convectors, and radiators. They are designed to be mounted on all HEIMEIER thermostatic valve bodies and on radiators with integrated valves which have an M 0 x 1.5 connecting thread on the thermostatic insert. Adapters and models with direct connections enable mounting onto thermostatic valve bodies from other manufacturers. The thermostatic heads use the energy of internal and external heat sources including solar heat, the heat radiated from people and electrical devices, and other sources, in order to keep the room air temperature constant. This helps to avoid wasting energy. Thermostatic heads with built-in sensors may not be covered by curtains, radiator facings, or other obstructions, or mounted vertically or in tight niches. Otherwise it will not be possible to precisely control the temperature. In other cases, it may be necessary to install a remote sensor or remote dial. Notes on installation Correct Circulation of air around the thermostatic head is not hindered. Correct The remote sensor enables an unhindered reading of the air temperature in the room. Underfloor convector Incorrect The thermostatic head with built-in sensor may not be mounted vertically. Incorrect The thermostatic head with built-in sensor may not be covered by curtains. Built-in cabinet Function In terms of controls, thermostatic heads are seen as continuous proportional controllers (P controllers) that require no auxilliary energy. They do not need an electrical connection or other source of energy. Changes in room air temperature are proportional to changes in the valve stroke. If the temperature of the air in the room increases due to sunshine, for example, the liquid in the temperature sensor expands and affects the corrugated pipe. This chokes the water supply to the radiator via the valve spindle. If the temperature in the room decreases, the opposite process occurs. The change in valve stroke caused by a change in temperature can be quantified as 0.22 mm per K room temperature change. 4

Thermostatic heads Operation Recommended room temperatures The following temperature settings are recommended for the corresponding rooms based on heating with cost savings in mind: Setting position for thermostatic heads K, VK, and WK, for example: Setting Room temperature Recommended for Position approx. e.g. 5 28 C (82 F) Swimming pool* 4 2 1 24 C (75 F) 22 C (72 F) 20 C (68 F) 18 C (64 F) 16 C (61 F) 14 C (57 F) 12 C (54 F) Bathroom Work room or children s bedroom Living or dining rooms (basic setting) Kitchen, corridor Hobby room, bedroom All rooms at night (nighttime reduction) Stairway, vestibule 6 C** (4 F)** Basement/cellar rooms (frost protection setting) INFO 6 C 14 C 20 C 4 C * If higher temperatures are required for the swimming pool area, special thermostatic heads are available (15 C (59 F) to 5 C (95 F) setting range). ** For thermostatic heads with an auxilliary zero position, the lowest setting is 0 C (2 F). Setting the temperature The desired room temperature can be selected by turning the thermostatic head (right = cooler, left = warmer). The arrow must be pointing to the appropriate setting position (number, bar, symbol). All HEIMEIER thermostatic heads are adjusted in a climatic chamber, free of external influences such as heat build-up, sunshine, etc. The number corresponds to a temperature of approximately 20 C (68 F). The difference between each number is approximately 4 C (7 F) (thermostatic head B approx. C (5 F), from bar to bar approx. 1 C (2 F). We recommend setting at the number which corresponds to the basic setting of about 20 C (68 F) room temperature. Settings above 4 should be avoided if a lower setting satisfies the comfort level, as a 1 C (2 F) higher room temperature corresponds to an increase in energy use of around 6 %. The K thermostatic head is also available with a limited setting range (Article no. 6120-500). The lowest setting at 1 corresponds to a temperature of about 6 C (4 F) and serves as the frost protection setting. The difference between this and the next number 2 is about 2 C (4 F) and to the next number around 4 C (7 F). This means that the number corresponds to a temperature of approximately 12 C (54 F). The highest setting is configured in 1 C (2 F) steps between 15 C (59 F) and 25 C (77 F). This is achieved by turning the thermostatic head to the left, up until it stops. 5

Thermostatic head K with built-in sensor Technical data Valve stroke limiter Setting numbers 1 to 5 Frost protection chrome RAL 7016 RAL 9005 RAL 705 RAL 707 Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Markings indicate upper and lower temperature range; two energy saving clips can be used to limit settings. Temperature range is limited on both ends and can be blocked using covered stop clips. Setting indicators on the face of the head and markings designed for the visually impaired. Max. sensor temperature 50 C (122 F) Hysteresis 0.2 K Water temperature influence 0.4 K Rotation direction indicator. Symbols for basic setting and nighttime reduction. Brief data including the most important settings. White cover RAL 9016 printed with scale. Designed to be mounted on all HEIMEIER thermostatic bodies and radiators with integrated valves which have an M 0 x 1.5 thermostatic insert. Refer also to the assembly and operating instructions. E-Pro time adaptor for time-dependent room temperature control without timeconsuming programming, see page 16. Differential pressure influence 0. K Closing time 24 min Illustration Model Setting Article range no. Standard 6 C to 28 C 6000-00.500 With two economy clips. (4 F to 82 F) Standard 6 C to 28 C Cap with graduation chrome. (4 F to 82 F) 6000-00.501 Cap with graduation RAL 7016, anthracite grey. 6000-00.50 Cap with graduation RAL 705, light grey. 6000-00.504 Cap with graduation RAL 707, dust grey. 6000-00.505 Cap with graduation RAL 9005 jet black. 6000-00.507 with zero position (valve opens at approx. 0 C or 2 F). 6 C to 28 C 7000-00.500 With two economy clips. (4 F to 82 F) Public buildings model 6 C to 28 C 6020-00.500 Standard (4 F to 82 F) With zero position (valve opens at approx. 0 C or 2 F). 0 C bis 28 C 7020-00.500 Theft protection using security ring. Increased strength (2 F to 82 F) in accordance with former German army certification TL 4520-0014 Stress group 1 (for highest stress). With two economy clips. with theft protection 6 C to 28 C 6040-00.500 using 2 screws. (4 F to 82 F) With two economy clips. For public indoor swimming pools, 15 C to 5 C 6200-00.500 medical spas. (59 F to 95 F) With two economy clips. Public buildings model lowest setting 6 C 6120-...500 Theft protection using security ring. (4 F), upper setting When ordering Staggered/limited setting range. in 1 C (2 F) incre- indicate upper Setting number based on setting range 1-/1-4/1-5. ments between value, e.g. Turn all the way left for highest setting. 15 C (59 F) to enter 20 for Increased strength in accordance with former 25 C (77 F) 20 C (68 F) German army certification TL 4520-0014. 6

Thermostatic head K with remote sensor Technical data Valve stroke limiter Setting numbers 1 to 5 Frost protection Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Markings indicate upper and lower temperature range; two energy saving clips can be used to limit settings. Temperature range is limited on both ends and can be blocked using covered stop clips. Setting indicators on the face of the head and markings designed for the visually impaired. Rotation direction indicator. Symbols for basic setting and nighttime Max. sensor temperature 50 C (122 F) Hysteresis 0.2 K Water temperature influence 0. K reduction. Brief data including the most important settings. Capillary tube coil for unused capillary tube. White cover RAL 9016 printed with scale. Designed to be mounted on all HEIMEIER thermostatic bodies and radiators with integrated valves which have an M 0 x 1.5 thermostatic insert. Refer also to the assembly and operating instructions. Special models can be designed upon request. E-Pro time adaptor for time-dependent room temperature control without timeconsuming programming, see page 16. Differential pressure influence 0. K Closing time 12 min (horizontal sensor) Closing time 15 min (vertical sensor) Illustration Model Setting Capillary Article values tube length no. Standard 6 C to 27 C 1.25 m (4.1 ft) 6001-00.500 With two economy clips. (4 F to 81 F) 2.00 m (6.56 ft) 6002-00.500 5.00 m (16.4 ft) 6005-00.500 8.00 m (26.25 ft) 6008-00.500 10.00 m (2.81 ft) 6010-00.500 with zero position 6 C to 27 C 2.00 m (6.56 ft) 7002-00.500 (valve opens at ca. 0 C or 2 F) (4 F to 81 F) With two economy clips. Public buildings model 6 C to 27 C 2.00 m (6.56 ft) 6022-00.500 Theft protection (4 F to 81 F) using security ring. With two economy clips. with theft protection 6 C to 27 C 2.00 m (6.56 ft) 6042-00.500 using 2 screws. (4 F to 81 F) With two economy clips. For public indoor swimming 15 C to 5 C 2.00 m (6.56 ft) 6202-00.500 pools, (59 F to 95 F) medical spas. With two economy clips. 7

Thermostatic head DX with built-in sensor verchromt RAL 7024 RAL 705 RAL 707 Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Reduced size in length and diameter. White cover RAL 9016 printed with scale. Designed to be mounted on all HEIMEIER thermostatic bodies and radiators with integrated valves which have an M 0 x 1.5 thermostatic insert. Refer also to the assembly and operating instructions. E-Pro time adaptor for time-dependent room temperature control without timeconsuming programming, see page 16. RAL 9005 pergamon Technical data Setting range 6 C to 28 C (4 F to 82 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection 6 C (4 F) Max. sensor temperature 50 C (122 F) Hysteresis 0.4 K Water temperature influence 0.7 K Differential pressure influence 0. K Closing time 24 min Illustration Model Article no. with built-in sensor Cap with graduation RAL 9016, white 6700-00.500 Cap with graduation chrome 6700-00.501 Cap with graduation RAL 7024, graphite grey 6700-00.50 Cap with graduation RAL 705, light grey 6700-00.504 Cap with graduation RAL 707, dust grey 6700-00.505 Cap with graduation RAL 9005 jet black 6700-00.507 Cap with graduation pergamon 6700-00.506 8

Thermostatic head D with built-in sensor Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. With rotation direction indicator. Reduced size in length and diameter. White cover RAL 9016 printed with scale. Designed to be mounted on all HEIMEIER thermostatic bodies and radiators with integrated valves which have an M 0 x 1.5 thermostatic insert. Refer also to the assembly and operating instructions. E-Pro time adaptor for time-dependent room temperature control without timeconsuming programming, see page 16. Technical data Setting range 6 C to 28 C (4 F to 82 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection 6 C (4 F) Max. sensor temperature 50 C (122 F) Hysteresis 0. K Water temperature influence 0.7 K Differential pressure influence 0. K Closing time 24 min Illustration Model Article no. with built-in sensor 6850-00.500 9

Thermostatic head B for public buildings Secured model designed for public buildings. Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Infinitely variable temperature setting using a special key without having to remove the protection cap. Protection cap can be turned endlessly. Protected against theft. Flexural strength of the thermostatic head min. 1000 N. White protection cap RAL 9016. Designed to be mounted on all HEIMEIER thermostatic bodies and radiators with integrated valves which have an M 0 x 1.5 thermostatic insert. Refer also to the assembly and operating instructions. Special models upon request. Technical data Setting range 8 C to 26 C (46 F to 79 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection 8 C (46 F) Max. sensor temperature 50 C (122 F) Hysteresis 0.2 K Water temperature influence 0.9 K Differential pressure influence 0. K Closing time 24 min Illustration Model Article no. public building model 2500-00.500 10

Thermostatic head F Remote dial Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Temperature range is limited on both ends and can be blocked using covered stop clips. Setting indicators on the face of the head. Rotation direction indicator. Symbols for basic setting and nighttime reduction. Brief data including the most important settings. May be installed at an outlet box. White cap RAL 9016 printed with scale. Connection piece designed to be mounted on all HEIMEIER thermostatic bodies and radiators with integrated valves which have an M 0 x 1.5 thermostatic insert. Refer also to the assembly and operating instructions. Special models upon request. Technical data Valve stroke limiter Setting numbers 1 to 5 Frost protection With zero position (valve opens at approx. 0 C or 2 F) Max. sensor temperature 50 C (122 F) Hysteresis 0.4 K Water temperature influence 0. K Differential pressure influence 0.4 K Closing time 26 min. Illustration Model Setting Capillary Article range tube length no. Remote dial 0 C to 27 C 2.00 m (6.56 ft) 2802-00.500 with built-in sensor (2 F to 81 F) 5.00 m (16.4 ft) 2805-00.500 8.00 m (26.25 ft) 2808-00.500 10.00 m (2.81 ft) 2810-00.500 15.00 m (49.21 ft) 2815-00.500 Remote dial with 0 C to 27 C 2 x 1.50 m 2881-00.500 remote sensor (2 F to 81 F) (2 x 4.92 ft) Central adjuster 11

Thermostatic head VDX for radiators with integrated valves The HEIMEIER thermostatic head VDX combines perfected technology with contemporary design. It has been specially designed for installation on radiators with integrated valves with M 0 x 1.5 connecting threads on the thermostatic insert. Its new construction blends harmoniously with the radiator, creating a single integrated unit. Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. White printed cap and trim RAL 9016. Refer also to the assembly and operating instructions. Technical data Setting range 6 C to 28 C (4 F to 82 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection Max. sensor temperature 50 C (122 F) Application The HEIMEIER thermostatic head VDX fits, for example, on the following radiators with integrated valves: Alarko Dunaferr Manaut Biasi DURA Purmo Caradon Stelrad Ferroli Radson Cetra Finimetal Rettig Concept Hagetec Superia DEF Henrad Termo Teknik Demrad HM Heizkörper VSZ DiaNorm Kermi Zenith Dia-therm Korado Date: 02.07 Technical changes made by the radiator manufacturer must be taken into account. Depending on the particular construction, the width of the side trim needs to be considered for type 11 radiators. Illustration Model Article no. with M 0 x 1.5 connection 6740-00.500 for radiators with integrated valves 12

Thermostatic head WK Angled form for radiators with integrated valves Technical data Setting range 6 C to 28 C (4 F to 82 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection Max. sensor temperature 50 C (122 F). The HEIMEIER thermostatic head WK has been designed for radiators with integrated valves which have a thermostatic insert with an M 0 x 1.5 connecting thread. The thermostatic head WK can be turned around for mounting on the left or right of the radiator. This allows you to use a single model for either mounting position. Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Markings indicate upper and lower temperature range; two energy saving clips can be used to limit settings. Setting indicators on the face of the head and markings designed for the visually impaired. Rotation direction indicator. Symbols for basic setting and nighttime set-back. Brief data including the most important settings. White cap RAL 9016 printed with scale. Refer also to the assembly and operating instructions. Application The HEIMEIER thermostatic head WK fits, for example, on the following radiators with integrated valves: Alarko Arbonia Biasi Caradon Stelrad Cetra Concept Demrad DiaNorm Dia-therm DEF Dunafer DURA Ferroli Finimetal Hagetec Henrad HM Heizkörper Kermi Korado Manaut Prolux Purmo Radson Rettig Superia Termo Teknik VSZ Zehnder Zenith Date: 02.07 Technical changes made by the radiator manufacturer must be taken into account. It is not permitted to use adapters for mounting onto thermostatic inserts that do not have an M 0 x 1.5 connecting thread. Illustration Model Article no. Angle form with M 0 x 1.5 connection 700-00.500 for radiators with integrated valves 1

Thermostatic head VK with clamp connection for radiators with integrated valves Technical data Setting range 6 C to 28 C (4 F to 82 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection Max. sensor temperature 50 C (122 F) The HEIMEIER thermostatic head has been designed to be mounted on radiators with integrated valves. The clamp connection with locking ring enables a direct connection to thermostatic inserts which do not have an M 0 x 1.5 connecting thread. The thermostatic head VK can be mounted in several different positions, each at 90. Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Markings indicate upper and lower temperature range; two energy saving clips can be used to limit settings*). Temperature range is limited on both ends and can be blocked using covered stop clips. Setting indicators on the face of the head and markings designed for the visually impaired. Rotation direction indicator. Symbols for basic setting and nighttime set-back. Brief data including the most important settings. White cap RAL 9016 printed with scale. Refer also to the assembly and operating instructions. Application The HEIMEIER thermostatic head VK fits, for example, on the following radiators with integrated valves: Baufa De Longhi Schäfer Bemm Küpper Thermotechnik Brötje Myson Vogel & Noot Brugman Northor Buderus Ocean CICH Rio Date: 02.07 Technical changes made by the radiator manufacturer must be taken into account. Illustration Model Article no. Standard 9710-24.500 with zero position 9711-24.500 (valve opens at approx. 0 C or 2 F) with theft protection 9710-40.500 using 2 screws 14

Thermostatic heads with direct connection for valve bodies from other manufacturers Thermostatic head with direct connection to thermostatic valve bodies from other manufacturers. Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Meet all requirements of the German EnEV and DIN V 4701-10. Limiting or locking of a setting. Rotation direction indicator (except thermostatic head DX). White cover RAL 9016 with printed scale. Technical data Setting range 6 C to 28 C (4 F to 82 F) Valve stroke limiter Setting numbers 1 to 5 Frost protection Max. sensor temperature 50 C (122 F) Illustration Model Article no. Danfoss RA, Ø 20 Danfoss RAVL, Ø 26 Danfoss RAV, Ø 4 Vaillant, Ø 0 Thermostatic head VK / K For Danfoss RA With energy saving clip. VK, Standard 9710-24.500 Thermostatic head VK with VK, with zero position 9711-24.500 2 energy saving clips. VK, with theft protection 9710-40.500 using 2 screws For Danfoss RAV K 9800-24.500 For Danfoss RAVL K 9700-24.500 For Vaillant 9712-00.500 K, for series from 1987. Thermostatic head DX For Danfoss RA DX 9724-24.500 For Danfoss RTD DX 9725-24.500 Danfoss RA, Ø 20 Danfoss RTD, M 0 x 1,5 Danfoss RA, Ø 20 TA, M 28 x 1,5 Thermostatic head D For Danfoss RA D 9720-24.500 For Herz D 6850-0.500 For TA D, for series until 1999. 9722-00.500 Herz, M 28 x 1,5 15

Thermostatic heads Accessories Illustration Article no. E-Pro 1950-09.500 Time adaptor for time-dependent room temperature control. It is installed between the valve and thermostatic head. With automatic open window recognition. Optional daily or weekly program. Including 2 batteries LR 6 (AA). E-Pro Stick for transferring a time program created on the PC to the E-Pro. 1950-09.160 Theft protection 6020-01.47 for thermostatic heads K, DX, D, WK. Please also refer to the Installation and operating instructions leaflet. Connecting to products from other manufacturers Adapters for mounting all HEIMEIER thermostatic heads on thermostatic valve bodies from manufacturers listed here. Standard M 0 x 1.5 threaded connection. Refer also Thermostatic head with direct connection to thermostatic valve bodies from other manufacturers.. *) can not be used on radiators with integrated valves Manufacturer: Danfoss RA 9702-24.700*) Danfoss RAV 9800-24.700 Danfoss RAVL 9700-24.700 Vaillant (Ø 0 mm) 9700-27.700 TA (M28 x 1,5) 9701-28.700 Herz 9700-0.700 Markaryd 9700-41.700 Comap 9700-55.700 Giacomini 9700-.700 Oventrop (M0 x 1) 9700-10.700 Ista 9700-6.700 Connection to radiators with integrated valves Series 2 (20 x 1) 970-24.700 Adapters for mounting HEIMEIER thermostatic heads Series (2,5 x 1,5), 9704-24.700 with an M 0 x 1.5 connection on thermostatic since 10/98 inserts for clamping connections. Standard M 0 x 1.5 threaded connection. Exception: The thermostatic head WK is designed only for mounting on thermostatic inserts with an M 0 x 1.5 threaded connection. Spindle extension for thermostatic valve bodies. Brass nickel-plated 20 mm (0.79 inch) 2201-20.700 0 mm (1.18 inch) 2201-0.700 Plastic, black 15 mm (0.59 inch) 2001-15.700 0 mm (1.18 inch) 2002-0.700 Capillary tube coil 6001-00.15 for rolling up unused capillary tube. Removal device 6000-00.18 for graduation cap of thermostatic head K and VK and for dismounting stop clips. Please also refer to the Installation and operating instructions leaflet. Setting key 2500-00.25 for thermostatic head B. Please also refer to the Installation and operating instructions leaflet. V-exakt F-exakt hahn Luft- Universal key 050-01.4 alternative to setting key art. no. 2500-00.25 for activating thermostatic head B (temperature setting), also for V-exakt / F-exakt thermostatic valve bodies, Regulux lockshield, Vekolux double connection fittings, and radiator air vents. Hexagon key for thermostatic head B and theft protection size 2 6040-02.256 with 2 screws on thermostatic head K. Please also refer to the Installation and operating instructions leaflet. 16

Thermostatic heads Dimensions Thermostatic head K with built-in sensor ø 5 (2.09") Thermostatic head K with remote sensor 22 (0.87") ø 5 (2.09") 87.5 *) (.44") 87.5 *) (.44") Supporting surface Supporting surface Thermostatic head DX with built-in sensor Thermostatic head D with built-in sensor ø 48 (1.89") ø 48 (1.89") 80 *) (.15") Supporting surface Supporting surface Thermostatic head F Remote dial with built-in sensor 80 (.15") 81 (.19") 22 (0.87") Remote dial with remote sensor (central adjuster) 80 (.15") 59 (2.2") ø 5 (2.09") 80 *) (.15") 81 (.19") Supporting surface 59, (2.") Supporting surface 59, (2.") 17

Thermostatic heads Dimensions Thermostatic head B Public buildings model with built-in sensor ø 49 (1.9 ") Thermostatic head WK Angle form for radiators with integrated valves ø 5 (2.09 ") 85 (.55 ") Supporting surface Thermostatic head VK with clamp connection for radiators with integrated valves and for Danfoss RA valve bodies ø 5 (2.09") 101*) (.98") ø 5 (2.09") 96 *) (.78") 9*) (.66") 91.5 *) (.60") Supporting surface 44 (1.7") 71 (2.80 ") Thermostatic head VDX with M 0 x 1.5 connection for radiators with integrated valves 54 (2.1") Supporting surface 80 *) (.15") 9,9 (.70") 120,8 (4.76") 26,9 (1.06") 20 (0.79 ") Thermostatic head K for Danfoss RAV valve bodies Thermostatic head K for Danfoss RAVL valve bodies ø 5 (2.09") 4 (1.4") 26 (1.02") 18

Thermostatic heads Dimensions Thermostatic head K for Vaillant valve bodies ø 5 (2.09") Thermostatic head DX with clamp connection for radiators with integrated valves and for Danfoss RA valve bodies ø 48 (1.89") 96*) (.78") 0 (1.18") Thermostatic head D with clamp connection for radiators with integrated valves and for Danfoss RA valve bodies ø 48 (1.89") Thermostatic head D for Herz valve bodies M 28 x 1,5 ø 48 (1.89") 80 *) (.15") 92,5 *) (.64") 92,5 *) (.64") 20 (0.79 ") Thermostat-Kopf DX for Danfoss RTD valve bodies M 0 x 1,5 ø 48 (1.89") 8,5 *) 20 (0.79 ") Thermostatic head D for TA valve bodies M 28 x 1,5 ø 48 (1.89") 80 *) (.15") 19

Thermostatic heads Thermostatic heads and valve bodies Certified and tested by CEN in accordance with DIN EN 215 (Series D and F) CEN symbol approval number 6T 0006 Thermostatic heads 2500-00.500 6000-00.500 6000-00.600 6001-00.500 6002-00.500 6005-00.500 6008-00.500 6010-00.500 6001-00.600 6002-00.600 6700-00.500 6850-00.500 7000-00.500 7002-00.500 Thermostatic valve bodies, Series D NW 10 NW 15 NW 20 2201-01.000 2201-02.000 2201-0.000 2202-01.000 2202-02.000 2202-0.000 2241-01.000 2241-02.000 2242-01.000 2242-02.000 41-01.000 41-02.000 42-01.000 42-02.000 511-01.000 511-02.000 511-0.000 512-01.000 512-02.000 512-0.000 Thermostatic valve bodies, Series F NW 10 NW 15 NW 20 2215-01.000 2215-02.000 2215-0.000 2216-01.000 2216-02.000 2216-0.000 515-01.000 515-02.000 516-01.000 516-02.000 Thermostatic valve bodies NW 10 NW 15 NW 20 2272-02.000 2072-0.000 2274-02.000 2276-02.000 2206-02.000 2244-02.000 2291-15.000 2292-15.000 517-15.000 518-15.000 Prospectus 1.1 Printed on chlorine-free bleached paper. 1100-18.48 / 12.08 We reserve the right to technical modifications.