TV2 Clean Room Monitor

Similar documents
TV2 Room Pressure Monitor Quick Start Guide

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Follett Performance Plus

LineGuard 2300 Program User Manual (FloBoss 107)

CSP-204 CSP-208 CSP-104 CSP-108

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

HOBO U14 Data Logger User Manual

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

EL-OEM-3 OEM Packaged Voltage Data Logger

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

THX-DL Data Logger USER & INSTALLATION MANUAL V

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

OPERATING INSTRUCTIONS. G214 Software - Version 4

Shanghai Xixun-----professional supplier of Led sign control system website: un.com Step2, plug u-disk into computer, open LED editor and choose upgra

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

STEMSEL Beginners Project 1: Alarm System

Ontech GSM 9040/50. Reference Manual English -1 -

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

rvm4c Installation Guide Remote Video Module

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

ProStar 325 UV-Vis Detector

Dryer Master DM510 Commissioning Guide

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

Galaxy. Galaxy Robot Sampler Page 1

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

PHD Dolphin Installation

iminiplus PDF User Guide Version 2.0

BURGLAR ALARM PANEL BS-468

FCD-wire Contents. List of Figures

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

ZSC100 Gas Detection and Alarm System Controller

Manage Alarms. Before You Begin. NTP-E57 Document Existing Provisioning CHAPTER

Manage Alarms. Before You Begin CHAPTER

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

DS7446KP. User Guide. Keypad

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Smart thermostat with Humidification/De-humidification control

Code Alert Series 30 Software User Guide

Alarm Calendar Version 1.10

Laptop / PC Programming Manual

Welcome to MultiSight TM Vision Sensor Hands-On Lab

AK-CS On Board Guide

EL-USB-1-LCD Temperature Data Logger with LCD

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

Static Pressure Control

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

Xtralis VESDA LCD Programmer Quick Reference Guide

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

Manual Supplement. Product/System Title: Premium Clean Room Monitor. Contents of this manual supplement include:

Manage Alarms. Before You Begin CHAPTER

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

Dashboard for Windows V1.1.0

PRODUCT SPECIFICATION

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Product Manual SZ1145

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Platinum Touch/Rotem One Touch

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

WeatherLink for Alarm Output Addendum

United Kingdom. Smart Thermostat 230 V Relay Installations. Guide for Professional Installers

abode Web app Functionality

Total Solution Sirius Cooling Control Unit (CCU) Sirius CONFIGURATION TOOL. (Windows -based configuration application.)

VAP304 PRO INSTALLATION & OPERATION MANUAL

Halton SAFE / 7.14 user guide and installation instructions

Product Manual SZ1009

Skipper's Mate. Sensor Testing. Version December Table of Contents

USER S GUIDE. AXIS Cross Line Detection

USRIC-8(M) USB PDF Temperature Recorder. Product User Guide. LogTag Recorders Ltd

Diagnostics and Monitoring System WEB Tool 2. User Manual

CODE ALERT Enterprise Software User Guide

SCAN200E USER S MANUAL

LogTag TICT - is0 Tag

THERMOMAX SMX 100. Microprocessor Based Refrigeration Controller Datalogger and Alarm ENGLISH.

Process & TeMPerATUre UniversAl input DigiTAl MeTers

False Alarm Management

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

Control Panel User Guide

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

169MHz Telecare Devices Sensor Controller

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

USER MANUAL USB Multi-Function Datalogger Model RHT35

Manage Alarms. Before You Begin CHAPTER

Product Manual SZ1144

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

Installing ProSeries 2005

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

Control Panel User Guide (TO BE RETAINED BY THE USER)

Sirius Technologies, Inc.

3D_ISS. Integrated Software System. User Guide Manual

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

VLT Vision Logger Temperature Recorder User s Guide

Transcription:

TV2 Clean Room Monitor 1. The Care and Use guide for your TV2 Clean Room Monitor can be downloaded here: www.e2di.com/usersguides.html Please print out the Users Guide. Although you should use the Users Guide to familiarize yourself with the TV2 installation and use, you can use the quick-start instructions below, if you are in a hurry. Your TV2 Clean room monitor comes with free software to copy the logged data from your TV2 to your computer. To download the free TView software go to www.e2di.com/pcsoftware/tview_software.html and click on TView Clean Room Monitor User Guide, copy the software to your desktop, unzip it and click on 'Setup' to install. It installs like any other windows software. Temperature/RH Sensor TV2 sensor sockets Pressure Sensor

QUICKSTART Your TV2 can be installed and operating in just a few minutes by following these simple steps. 1. Connect the USB cable to a PC or wall plug and the System Parameter display will appear. 2. Touch Up or 'Down' to select C or F and touch Enter. 3. Touch Up to select the date format (MM/DD/YY, DD/MM/YY or YY/MM/DD) and then 'Enter'. The date format defaults to the US style (MM/DD/YY). 4. Set the day, month, year, hour and minute in the appropriate field by scrolling through the possible values with 'Up' or 'Down' after moving to the appropriate field with 'Enter'. (Note: It is possible to move to another field with the Right button but your entries will not be recorded). 5. Touch Escape. You will be asked to verify that you want to erase all data. Use Right to highlight YES and touch 'Enter'. 6. Touch 'Escape' to return to the previous menu. The TV2 Clean Room Monitor is operational

Setting up sensors 1. Plug the pressure sensor into the socket next to the small green relay on the end of the TV2 display and the temp/rh sensor next to it. Position the pressure sensor so that the positive and negative clear plastic tube openings are in different rooms to see the pressure differential. 2. After a few seconds, the TV2 will recognize the first sensor and change the display to the Sensor Setup menu. Move the cursor to the Sample Data field by touching Right. 3. This is how often you want the sensor to log a pressure reading. You may scroll to any value between 1 min and 24 hrs with 'Up' or 'Down', touching 'Enter' to move to the minute and second field, or accept the default by touching 'Enter'. The default value is ten minutes (00:10:00). For pressure sensors we recommend you set it for 15 seconds (00:00:15). 4. Select the type of averaging by touching 'UP', or 'Down' and then 'Enter'. There are three possible selections. a. Fast no averaging occurs. The exact measurement at the time of sampling will be stored and displayed. (Not normally used except during calibration) b. Medium- some averaging will take place so that minor temperature fluctuations will be filtered out. (This is the default value). c. Slow additional averaging will occur. (Not normally used). 5. Set the chart display (Y axis) with Up and Down. This does not set the alarm. These setting have no effect on the alarm, what data is collected, or what is stored. It simply sets the upper and lower point of the Y-axis of the data chart shown on the TV2. Any data point that cannot be displayed on the chart because it falls outside these limits will show as a point at the top or bottom of the display. Note: These limits can be adjusted at any time without affecting your data.

Setting the sensor alarms 6. Set Alarms, if needed, by highlighting the Set Alarm button on the 'Sensor # Setup' screen with 'Left' or 'Right' and touching Enter. 7. Enable the alarm by touching 'Up' and then 'Enter'. 8. Set the trigger-alarm-time to any value between 0:00 and 99:00. This controls how long the alarm and the relay will be activated. Note: If you are using a dialer set it for at least 00:30 (30 seconds) but not longer than 06:00 (Six minutes). 9. Scroll in the upper alarm data limit and delay time and then the lower alarm limit and delay with 'Up and Down touching 'Enter' to move to each field in turn. Note: The delay time is how long the temperature must remain above (or below) the limit before the alarm occurs. 10. You do not need to enter the Calibration Menu at this time. (For calibration procedures see the document Entitled Calibration Procedures on the CD. It can also be downloaded from our website http://www.e2di.com/pdfs/calibration Procedures.pdf) 11. Touch 'Escape' until you return to the Status Screen. You are done!

Quick Check The Easy Touch display indicates the safe/unsafe condition of room pressure, temperature and humidity at all times. If all the numbers are green then all is OK, but if any of them appear red the clean room should not be used until the red condition is corrected. Condition If Green If Red Pressure OK Do not use room until positive pressure is restored Temperature OK Adjust thermostat Humidity OK Check humidity control Alarm Alarms set Enable alarms (sensor setup menu) Max/Min OK Condition was unsafe in the past Reset by touching Battery Icon Charged No action required it will charge itself If any condition (pressure, temperature or humidity) is red it is outside the safe conditions and the room should not be used. Safe limits are set in the alarm menu of each sensor.

If the Minimum pressure setting is red the pressure dropped below the safe conditions in the past. As long as the current pressure is green it is ok. Check the logged data to see what happened. If the Alarm is disabled the quick check will be unable to display red conditions. It should be enabled and alarm conditions set in the sensor setup menu.