ELECTROMAGNETIC COMPATIBILITY OF SMART INSTALLATIONS

Similar documents
Electromagnetic Compatibility of Alarm Systems

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

The New EMC Directive 2004/108/EC

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

INTERNATIONAL STANDARD

EMC Regulatory Requirements: What you need to know for the EU, EAEU & Australia. Dr Alex Martin

REA 105 Arc Protection Module. Operator s Manual

The New EMC Directive 2004/108/EC

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Flame detector. The QRA4.U is for use with the following types of burner control:

STS Directory Accreditation number: STS 0009

This second part of the lesson & is dedicated to EMC legal aspect and standards.

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Operation and use. Functions and characteristics

This document is a preview generated by EVS

AUGUST 2016 CONTENTS:

EMC Emissions in the Machine Industry

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

for relative humidity and temperature with calibration certificates

Provläsningsexemplar / Preview TECHNICAL REPORT PUBLICATION FONDAMENTALE EN CEM BASIC EMC PUBLICATION. Electromagnetic compatibility (EMC)

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ANSI-ASQ National Accreditation Board/ACLASS

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

On Electromagnetic Compatibility

Flame detector. The QRA4.U is for use with the following types of burner control:

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

CENELEC GUIDE 24. Electromagnetic Compatibility (EMC) Standardization for Product Committees concerned with apparatus. Edition 3,

INTERNATIONAL STANDARD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

INTERNATIONAL STANDARD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Security, Efficiency and Comfort with KNX

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

This document is a preview generated by EVS

INTERNATIONAL STANDARD

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

C 271/32 Official Journal of the European Union

EMI/RFI Filters. Motor Protection

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

C-Bus Neo Range Installation Instructions. 5050NL Series

ISO INTERNATIONAL STANDARD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

INTERNATIONAL STANDARD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

DD15 Interface Module Product Guide

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ISO INTERNATIONAL STANDARD. Road vehicles Alarm systems for buses and commercial vehicles of maximum authorized total mass greater than 3,5 t

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

Electromagnetic compatibility (EMC)

C-Bus Reflection Range Installation Instructions

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

TECHNICAL SPECIFICATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

Design of Microwave Anti-theft Alarm Based on Microcontroller

INTERNATIONAL STANDARD

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Gas meters - Conversion devices - Part 1: Volume conversion

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

INTERNATIONAL STANDARD

3kW 6kW, QUBE Fiber Lasers

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

INTERNATIONAL STANDARD

EMC Bayswater Pty Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

PIR-100B User Manual

CE marking & your legal obligations

Rules for Classification and Construction Additional Rules and Guidelines

INTERNATIONAL STANDARD

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Guideline No.: S-02(201510) S-02 Navigation Light and Signal Light Controllers. Issued date: October 20,2015. China Classification Society

CE Marking and Technical Standardisation

EU Declaration of Conformity

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Audible warning devices for external alarm

Transcription:

POZNAN UNIVE RSITY OF TE CHNOLOGY ACADE MIC JOURNALS No 81 Electrical Engineering 2015 Dorota TYPAŃSKA* Wojciech MACHCZYŃSKI* ELECTROMAGNETIC COMPATIBILITY OF SMART INSTALLATIONS The paper presents the problem of protection of smart houses against electromagnetic disturbances. The technology associated with intelligent buildings was explained in detail. Attention was drawn to possibility of using specific technologies installed in different places. Electromagnetic disturbances that may affect the operation of sensitive electronic of intelligent building were characterized. The spread way of these disturbances and their methods of reduction were described. KEYWORDS: electromagnetic compatibility, intelligent building, electromagnetic disturbances, KNX, smart installations 1. INTRODUCTION Rapid technological developments observed since the second half of the twentieth century contributed to a significant increase in the number of electrical appliances used by humans in everyday life. The variety of modern equipment caused that the electrical installation in buildings has become more expanded and thus complicated. There are currently on the market many electrical systems that allow one to control, inter alia, heating, lighting, ventilation, air conditioning, blinds etc. [3]. Using the term "intelligent building", we mean the object that has the ability to control the aforementioned systems independently. In addition, it allows easy expansion or reconfiguration of further systems got in the future. It is a specific combination of the latest technological developments and minimization of the cost of exploitation of the building. Intelligent building is a house, equipped with a large amount of electronic devices sensitive to electromagnetic disturbances. Therefore, it is necessary to protect these devices from damage or malfunction. It is also important to check whether the installation does not interfere with other devices which are working close. * Poznan University of Technology.

96 Dorota Typańska, Wojciech Machczyński 2. INTELLIGENT BUILDING Intelligent building, also known as smart house, is it a highly technically advanced building with automatic, very flexible management system. Intelligent building has a system of sensors and detectors, and a single integrated system management of all located in the building installations. With the information from different parts of the system, it allows the reaction to changes in the environment inside and outside the building. It also allows to maximize functionalism, comfort and safety and to minimize operating costs and modernization. An exemplary diagram of the smart house is shown in Fig. 1. Fig. 1. Scheme of intelligent building [6] The most widespread is the KNX system, which is based on the experiences and solutions used in computer networks. The intelligent system is a decentralized control system used for switching, regulation and supervision of technical equipment in the building. In traditional electrical system to realize each function it is required the conduct of a separate cable and each control system has its own separate network. Separation of controlling and monitoring occurs in KNX system.

Electromagnetic compatibility of smart installations 97 The most commonly used is the SELV network (Safety Extra Low Voltage) with nominal voltage 24V DC, which is a source of information and power for systems operating in the KNX system and responsible for signal transmission. Each element is equipped with its own microprocessor electronic system that allows to implement distributed intelligence functions [1]. Fig. 2. Construction of KNX system [8] The devices connected to the bus can be divided into sensors and actors. Such division is shown in Fig. 2. Sensors are responsible for detecting changes in certain physical quantities occurring in the building, and actors perform the tasks assigned to them on the basis of instructions from the sensors. Sensors can be devices such as buttons on-off control, power controllers, sensors, light intensity, temperature, humidity and control elements for example temperature controller or visualization panel [1]. 3. ELECTROMAGNETIC COMPATIBILITY OF INTELLIGENT INSTALLATIONS Designing intelligent building installation, it is important to take into account the electromagnetic compatibility. Electronic devices and systems, especially with a high degree of integration, have a low immunity against electromagnetic disturbances [4]. A system is electromagnetically compatible with its environment if it satisfies three criteria [6]: 1. It does not cause interference with other systems. 2. It is not susceptible to emissions from other systems. 3. It does not cause interference with itself.

98 Dorota Typańska, Wojciech Machczyński Designing for EMC is not only important for desired functional performance; the device must also meet legal requirements in virtually all of the world before it can be sold. The legal aspects are regulated by Electromagnetic Compatibility Directive [2] and the standards summarized in Table 1. Table 1. Condensed statement of standards for electromagnetic compatibility Type of standard Electromagnetic emissivity Electromagnetic immunity Title of standard IEC 55022 - Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement. IEC 61000-4-2- Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test. IEC 61000-4-3 - Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test. IEC 61000-4-4 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test. IEC 61000-4-5 - Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test. IEC 61000-4-6 - Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields. IEC 61000-4-8 - Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test. IEC 61000-4-9:1998 - Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Pulse magnetic field immunity test. In the considerations relating to the electromagnetic compatibility both intelligent electrical installation and the traditional, the important issue are the methods of the spreading of electromagnetic disturbances. These include [5]: conduction along the wires connecting the device to the environment, direct capacitive coupling, direct inductive coupling, radiation by electromagnetic fields. Basic types of coupling mechanisms are shown exemplary in Fig. 3, for case of two current circuits [5]. Galvanic coupling between the two circuits occurs when the currents flow through the common impedance. While the cause of the presence of capacitive coupling, are the parasitic capacitance and of the inductive coupling circuit

Electromagnetic compatibility of smart installations 99 condition is the presence of parasitic magnetic flux. The cause of the impact of radiation are electromagnetic waves emitted from the power circuit. All types of electromagnetic disturbances shown in Fig. 3 can occur in the intelligent buildings. Hence, it is very important to test each intelligent system separately, in the installation site, primarily for immunity to electromagnetic disturbances. Fig. 3. Basic types of coupling mechanisms [5] 4. CONCLUSIONS All electrical and electronic equipment put on the European market must be tested and certified (CE mark) by certified EMC laboratories. However, the certification of individual devices does not guarantee that the fully complete, mounted installation is electromagnetically compatible. This is due to the fact that each installation operates in specific conditions, and is exposed to various disturbances (it is possible that more than one disturbance influence the device

100 Dorota Typańska, Wojciech Machczyński at the same time). Particularly sensitive to the electromagnetic interference are intelligent systems, for example presented in the second chapter, the KNX installation equipped with electronic systems. At the moment, electromagnetic compatibility tests of mounted installations in buildings are not carried out. The EMC Directive [2] requires the testing of such systems, however, it does not specify how this should be done. At the moment only electromagnetic disturbances reduction using for example groundmass installations, electromagnetic compatibility filters and electromagnetic shields is in use. REFERENCES [1] Brylińska A.: Intelligent building (in Polish), Master of science thesis, 2006. [2] Directive 2004/108/WE - Electromagnetic compatibility. [3] Holuk M.: Intelligent building - Home control capabilities in the XXI century (in Polish), Scientific Bulletin of Chełm, Section of Technical Sciences,No. 1/2008. [4] Kachel L., Kelner J., Laskowski M., Przybysz A. : EMC problem in an intelligent building (in Polish), Telecommunication overview vintage LXXXII and telecommunication news vintage LXXVIII (in Polish), no. 8-9/2009. [5] Machczyński W.: Introduction to electromagnetic compatibility (in Polish), Poznan University of Technology publishing house, Poznan 2010. [6] Paul C.: Introduction to electromagnetic compatibility, published by John Wiley and Sons, Inc., Hoboken, New Jersey, 2006. [7] http://www.iqsystem.net.pl/grafika/int.inst.bud.jpg [8] http://www.energoelektronika.pl/do/shownews?id=2220