OPERATION AND MAINTENANCE BOOK. Glycol Deck 250 PREAMBLE

Similar documents
IMI CORNELIUS CHILLER

Power Pack Service Manual

Power Pack Service Manual

CH250 AND CH251 CHILLERS

POWER PACK SERVICE MANUAL

Power Pack Service Manual

POWER PACK SERVICE MANUAL

Operator s Manual. IP-100 Immersion Probe Cooler

Frosty Factory of America, Inc.

CH750, CH751 & CH951 CHILLERS

CHILLER. Model CH3000. Operator s & Installation Manual

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Operator s Manual. Histology Bath

INSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY

Horizontal Bottle Cooler Installation and Operation Manual

ThermoSaver TM Hot Gas Defrost System

Installation, Operation & Service Manual

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

CHILLER MODEL: CH1500, 2000 AND 3000

Installation, Operation and Maintenance Manual

BEFORE FIRST USE: TABLE OF CONTENTS

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

ion Genesis Pump Controller

MOD. 605 E. Made in Italy INSTRUCTION MANUAL

AUTOMATIC GRANULAR ICE FLAKER

INSTALLATION and OPERATION INSTRUCTIONS

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

UPUTSTVO ZA RAD USER INSTRUCTIONS GEBRAUCHSANWEISUNG ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ И СОДЕРЖАНИЮ

INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

INSTRUCTION AND MAINTENANCE MANUAL

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Beverage Air IMPORTANT

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

CHILLER. Operator s & Installation Manual

MODULAR AUTOMATIC GRANULAR ICE FLAKER

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TMEF Series. SKOPE Vertical Freezer. User Manual

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

OPERATOR S MANUAL. Cooling Unit LMK 1.3D/U. manufactured by: LAURI S.r.l. Via G. Di Capi, 11/A MANTOVA ITALY

USERS MANUAL FOR GAS BOILERS

MODEL: TD1000X 10 SHEET CROSS CUT SHREDDER

Read these instructions before using and keep them available at all times!

VALUE SERIES SLIMLINE MULTIDECKS

AUTOMATIC MODULAR ICE FLAKER

Instructions for use. WT 40 Wine Cooler

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

Owner s Manual for Swimming Pool Heat Pump

CAREL IR33+ CONTROLLER

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

XC Portable Air Conditioning

AUTOMATIC MODULAR ICE-CUBE MAKER

T-Series Air Conditioner T53 Model

CHILLERS. Operator s & Installation Manual

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

MACH N-407 Heat Pump Air-Cooled Chiller

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

AUTOMATIC ICE-CUBE MAKER

EC3-X33 Stand-alone Superheat Controller Technical Data

PURESTREAM. ACW Air Cooled Fluid Cooler User and Maintenance Manual AMBIENT FLUID COOLER BY FRIULAIR

Superdryer Dehumidifiers

NON-SUBMERSIBLE WATER PUMP

Surna 25-Ton Chiller Operating & Maintenance Manual

High Output Vacuum/Pressure Pump

Dear Valued Customer:

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS for HOAM and VOAM Open Air Merchandisers

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

TCW 2000 Ice liner refrigerator and freezer PIJ

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

TTV 4500 / TTV 4500 HP / TTV 7000

OWNE R S MA N UA L. Made in USA. September 2015

Carmen. Operating Instructions. 1

PREP TABLES AND UNDERCOUNTER REFRIGERATION INSTRUCTION MANUAL

VF Series. User Manual. SKOPE Vertical Freezer. MAN10521 Rev. 3.3 Jun VF1000

Instruction Manual Reach-In Refrigerators & Freezers

NESLAB CB 60/CB 80 Cryobaths. Operation. Product Service Information, Applications Notes, MSDS Forms, .

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i

MASTERCOOL (MIC, MICH)

T-Series Air Conditioner T20 Model

User and maintenance manual

REFRIGERAT A OR USE DF1-15 F ridge

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Transcription:

OPERATION AND MAINTENANCE BOOK Glycol Deck 250 Document Code: 0150GLDECEN.000 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties without our authorization. serial number: PREAMBLE The present handbook must be considered as integral part of the equipment, and it must always be available to the persons operating with the unit; this manual must always stay with the equipment, also in case the unit is transferred to another owner. The operators must carefully read this handbook and follow all instructions herein contained, because VINSERVICE will not be liable for any damages occurred to persons and/or things, or suffered by the equipment itself, whenever any conditions here in described are not respected. Customers has the obligation of respecting the industrial trade secret, according which the following literature and its enclosures could not be altered, edited or sold to third parts, without the explicit authorization of VINSERVICE. VINSERVICE s.r.l. Via G. Falcone, 26/34 24050 ZANICA (BG) Italy Phone: +39 035.672361 Fax: +39 035.672699 www.vinservice.it e-mail: info@vinservice.it 1

TABLES OF CONTENTS REV 300113 PREAMBLE...1 RECCOMENDATIONS, SUPPLY CONDITIONS...3 GENERAL INFORMATION, TECHNICAL SPECIFICATION...4 TRANSPORTATION, ACCIDENT PREVENTION AND RESIDUAL RISKS,...5 INSTALLATION AND ADJUSTMENT...5 HYDRAULIC CONNECTIONS, THERMOSTAT REGULATION...6 THERMOSTAT REGULATION...7 MAINTENANCE, TROUBLESHOOTING...8 TECHNICAL DRAWINGS...9 EXPLODED VIEW...10 NOTE...11 DECLARATION OF CONFORMITY...12 2

1. RECOMMENDATIONS This instruction manual should be read in its entirety before using the equipment. Complete knowledge of the information contained herein is essential to the proper functioning and operation of this equipment. The equipment has been designed and built with mechanical safety devices suitable to protect the skilled operator from physical damage. The skilled operator must be fully aware of the operation mechanisms of the equipment and it is the buyer s responsibility to make sure that only competent personnel are allowed to operate it. The use of original spare parts is essential to the optimization of the equipment s potential and any modifications carried out are the sole responsibility of the skilled operator. The skilled operator is responsible for all the operations necessary to maintain the equipment in good working order. CAUTION Always disconnect the equipment s electrical socked from the mains before accessing its internal part. Do not remove protective covers or safety grids during operation. Keep hands away from moving part. 2. SUPPLY CONDITIONS VINSERVICE will not be held liable for any failure to comply with the standards governing correct. VINSERVICE will not be held liable for any loss in production, unless expressly shown in the purchase order. VINSERVICE will not be held liable for any defects or malfunction arising from; improper use of the equipment, alterations due to the transportation or peculiar environmental conditions, lack off or improper maintenance, manhandling or improper service; operation by unqualified personnel and the use of product accessories not belonging to the equipment. VINSERVICE will not be held liable for damages arising from inappropriate or imprudent operations not conforming to those described within this manual and in the attached documentation performed by both expert and inexpert personnel. Since it is not possible to foresee all the installations and environments in which this equipment will be installed, therefore customer must check the following: -Environmental conditions where the equipment is installed; -Beverage feeding and pushing systems; -The capacities of the personnel entrusted with the installation and/or use of the machine. N.B. Manufacturer accepts liability for commercial parts. If in doubt, ask for documentation. VINSERVICE will not be held liable for the disposal of equipment parts or materials needed to operate the machine: coolant gas, compressor or under pressure container, condensers, etc Please remember that this is an electrical equipment and thus its components must be disposed in compliance with the regulations enforced in its country of installation. 3

3. GENERAL INFORMATION 3.1. Equipment Description This equipment is composed of a refrigerating unit assemble between a metal plate and a glycol bath. 3.2 Appropriate Uses This equipment is intended for the cooling of well insulated and carefully configured trunk lines. In operation, cold food grade liquid propylene glycol is pumped through cooling lines that are parallel to and in contact with the product line. 3.3 Inappropriate Uses This equipment is not intended for use other than that described above. This equipment has not been designed to operate in adverse environmental conditions, including excessive humidity and explosive atmosphere. 3.4. TECHNICAL SPECIFICATION Cooling Distance 250 Feet, 76.2 m Compressor 1/2 Hp Refrigerant R 134 A Charge 0.275 Kg, 9.7 Oz Voltage 115 V 60Hz Current 7 Amp Temperature control Digital Pump 184 Watt Bath Capacity 50 Liters, (13.2 Gallons) Foam Insulation 1 inch Inlet Barb 3/8 Outlet Barb 3/8 Dimensions. H x L x W 712 x 473 x 451 mm 28 x 18.6 x 17.75 Box Dimensions 750 x 610 x 650 mm 4

4. TRANSPORTATION 4.1 Packaging The equipment is usually shipped in a cardboard box packaging, adequately protected on all its edges. The packaging in its dry and integral state is self-supporting and sturdy enough for machine lifting and handling. If packaging is in a wet state, pay attention while lifting and make sure lifting bands are placed in the centre. 4.2 Transportation and handling Stacking of equipment over another is only allowed when packaging is in its integral and dry state. Equipment should be lifted one at a time. The lifting equipment (ropes, polyester belts, chains) must be designed to bear the weight of the machines: the opening angle must be the same as or less than 50-60 in order to avoid crashing or damaging the packaging and/or the bodywork sheet metal. 5. ACCIDENT PREVENTION AND RESIDUAL RISKS Although this equipment has been manufactured under the strictest safety regulations, however for obvious reasons it is not possible to foresee all the installations and environments in which this equipment will be installed. Therefore it is pertinent that customer should inform the manufacturer of peculiar installation conditions. The instructions set out in this manual do not replace the safety instructions and technical data on installation and operation of the equipment. It neither replaces common sense nor the safety regulations enforced in the country of installation. Operators must be given correct information. They must therefore read and follow the technical information set out in the manual and in the attached documentation. VINSERVICE will not be held liable if installation instructions are not followed. The equipment has been designed under strictest energy saving regulations enforced in the manufacturing country therefore customer should avoid unnecessary energy waste. 6. INSTALLATION AND ADJUSTMENTS 6.1 Installation After removing the machine from its packaging, check that: A -The area where the machine is to be installed is solid and perfectly level; B -The cooler is positioned far from heat or humidity sources. C -The condenser and the grills are free. It is recommended to leave a 20-30 space cm from wall to grant a good air circulation in the condenser. 6.2 Filling of the glycol bath After settling the cooler as indicated proceed with bath filling. Remove the equipment s top cover and then fill the bath with a glycol water solution without added addictives up to 1 from the bath top. After filing, replace the top cover. Connect a plastic hose to the overflow pipe and then to the nearest drain. We recommend the use of food grade propylene glycol, mixed in a ratio of 25 % glycol and 75 % water. We also recommend the use of a refractometer to check the mixing ration. The correct mixing ratio should be 16 BRIX. This control operation should be done every 2 months. In the case of values lower than 16, mixing ratio should be corrected by adding more propylene glycol. 5

6.3 Hydraulic connection A. Connect one line from isolated trunk line to pump outlet; B. Connect second circulation line to the inlet of the tub. C. Make sure all re-circulation lines are properly connected and turn the pump motor on. D. Liquid level will drop until circulation lines are full; E. Refill with water approximately 1 from cover. F. Temperature will slowly drop to 30 F on thermostat/outlet gauge; 6.4 Regulating the thermostat FRONT PANEL DESCRIPTION KEYS DESCRIPTION P 1.Key : Used for setting the Set point and for programming the function parameters. 2.Key / Aux: Used for selecting the parameters and for decreasing the values to be set. 3.Key / : Used for selecting the parameters and for increasing the value to be set. Also used for activating manual defrost. 4.Key : Used for visualizing the read temperatures. LED INDICATORS 5.Led OUT: Indicates the compressor or temperature device output status. Led on= (ON), Led off = (OFF), Led blinking = (INHIBITED) 6.Led DEF: Indicates defrost status. Led on= DEFROSTING IN PROGRESS. Led blinking= DRIPPING. 7.Led FAN: Indicates fan status. Led on = (ON), Led off = (OFF) Led blinking = DELAYED AFTER DEFROSTING. 8.Led AUX: Indicates AUX output status. Led on = (ON), Led off = (OFF), Led blinking = (INHIBITED). SETTING THE SET POINT P Press and release it and SP1 or SP2 will be visualized on display depending on the active set. Use and to modify. P Press to exit the set mode or press no key for 15 seconds. SETTING CONFIGURATION PARAMETERS: Switch on the cooler and make sure no procedure is running. To access function parameters; TO SELECT A PARAMETER GROUP 9.Led AL: Indicats the alarm status. Led on = (ON), Led off = (OFF), Led blinking = (SILENCED or MEMORIZED). 10.Led SET: Indicates access to programming mode and programming level of parameters. It also indicates standby status. 11.Led - : when (ON), it indicates that a low temperature alarm is in progress. When (BLINKING), it indicates that a low temperature alarm has been memorized. 12.Led OK: Indicates that no alarms are in progress 13.Led +: when (ON), it indicates that a high temperature alarm is in progress. When (BLINKING), it indicates that a high temperature alarm has been memorized. SETTING CONFIGURATION PARAMETERS: TO SELECT A PARAMETER Using and to select the desired parameter. TO MODIFY A PARAMETER When the display shows the parameter you would like to modify P Press to memorize new value and display will only show the abbreviation of the selected parameter. P Keep pressed for about 5 seconds, after which the Led SET comes on and SP is visualized on display. Press and to select the parameters group to be modified. P Press and the code that identifies the parameter in the selected group will be visualized. 6

6.4 Regulating the thermostat REV 300113 SETTING CONFIGURATION PARAMETERS: TO MODIFY OTHER PARAMETERS Use and to select and modify other parameters, and repeat steps as earlier described. TO QUIT THE PROCEDURE Keep and pressed until programming mode is exited or leave no key pressed for about 20 seconds. THERMOSTAT PROGRAMABLE PARAMETERS -6 C 21.20 F -6 C 21.20 F -6 C 21.20 F -5 C 23 F -5.5 C 22.1 F FLAT COLDER -5 C 23 F NTC OFF 2.5 0 OFF 1 OFF 7

7. MAINTENANCE 7.1 Ordinary maintenance Keep liquid level constant in glycol reservoir. A. Check liquid monthly. If level is low, fill with water. B. If ice builds up, remove one gallon of water and replace with glycol. Clean the equipment monthly as it may have sucked in dust and filaments that may overhear motor or cause faulty operation. 7.2 Extraordinary maintenance A. Glycol should be changed every year except in very hot areas where it should be changed every six (6) months. B. Keep condensing unit free of foreign matter and clean every six (6) months. 7.3 Storing, dismantling and disposal If the equipment remains unused for long periods, disconnect the power plug, hydraulic and electric systems; empty and clean it; sanitize and wash the coils. Allow cleaned parts to dry, plug and then store the equipment in its original packaging if available. 8. TROUBLESHOOTING If the control system does not function properly, verify that the unit is wired, configured and set properly. If the problem persists, use the following procedures to determine the cause of the problem: PROBLEM CAUSE SOLUTION (S) 1- Compressor does not start (no hum), but the fan motor runs. 2 - Compressor starts and continues to run until freeze up and will not cut off. A - Compressor relay or capacitor malfunction B - Inadequate voltage C - Compressor failure A -Thermostat control failure B - Freon Leak A - Replace compressor relay, overload or capacitor B - Measure voltage across common and run terminal on compressor. Voltage must not drop below 90% of rated voltage. C - Replace compressor A - Replace thermostat B - Repair leak and recharge 3 - Compressor does not run but hums. A- Inadequate voltage B - Starting relay malfunction C - Compressor malfunction A - Measure voltage across common and run terminal on compressor. Voltage must not drop below 90% of rated voltage. B - Replace starting relay. (Be sure to use correct relay. Failure to do so will cause compressor failure.) C - Replace compressor 8

A A TECHNICAL DRAWINGS REV 300113 438mm - 17.2 In 727 mm - 28.6 In 279mm-11In 450 mm - 17.7 In SEZIONE A-A SCALA 1 : 6 473mm - 18.6 In 9

Exploded view REV 300113 10

NOTE REV 300113 11

Machines 2006/42/CE Low tension 2006/95 CE EMC 2004/108 CE Glycol Deck HE 40-60 - 90-100 - 120-140 - 150-250 - 600 250 28 02/05/2011 Gen. 2010 RICCARDO GUADALUPI GRADUATE OENOLOGIST 12