USER'S INFORMATION MANUAL

Similar documents
USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

TO DO IF YOU SMELL GAS

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

Cast Iron Commercial Hot Water Or Steam Boiler

User manual. Logano GC 124 II. Gas boiler

User s Information Manual

User s Information Manual Models: 45, ,000 Btu/hr

USER'S INFORMATION MANUAL

/2010 US/CA

USER'S INFORMATION MANUAL

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

User s Information Manual Models:

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

Tankless Water Heater

USER S INFORMATION MANUAL

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Multi Boiler Guide. Kit #

User Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown

ProLine XE Combi Boiler

Connecting cable. Installation instructions (2018/04) US

95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER

Universal Fire Tube Boiler Wall Mount Models

and/ or User s Information Manual

User s Information Manual Models:

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL (2,4)SG13B

User s Information Manual

ENVI Boiler Controller

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Residential Gas Hybrid Water Heater

AFUE 95% Heating Input 50,000 to 200,000 Btuh

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

USER S INFORMATION MANUAL

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

and/ or User s Information Manual WARNING

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

User s Information Manual Models:

Marquis User s Manual

User s Information Manual

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

USER'S INFORMATION MANUAL

User s Information Manual

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

User s Information Manual

MC Series Gas-Fired Heating Appliance

User s Information Manual

Operating instructions

USER S INFORMATION MANUAL

User s Information Manual

Operating instructions

Elite. User s Information Manual. Elite and Elite VWH* All Models

User s Information Manual Models:

WARNING FOR YOUR SAFETY

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

User s Information Manual

User s Information Manual Models:

HWX GAS BOILERS USER S INFORMATION MANUAL

User s Information Manual Models:

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

Operating instructions

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

USER S INFORMATION MANUAL

COMMERCIAL GAS WATER HEATERS

User s Information Manual

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

User s Information Manual Models:

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

prestige Control Application Supplement - Type 5 MCBA WARNING

USER S INFORMATION MANUAL

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

EL195UHE SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING

Control manual and troubleshooting guide

User s Information Manual

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD.

User s Information Manual Models: WH

GOLD. User s Information Manual. Water Boiler Series 4

WHAT TO DO IF YOU SMELL GAS

User s Information Manual Models: 400, 500, 600, 725, & 850

ARM SERIES Switching Relays With Priority

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

EL195DFE SERIES GAS FURNACE WARNING

Transcription:

USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Information and specifications outlined in this manual in effect at the time of printing of this manual. Manufacturer reserves the right to discontinue, change specifications or system design at any time without notice and without incurring any obligation, whatsoever. P/N 240008847, Rev. B [06/2011]

1 - GENERAL 1.1 General This boiler has few user serviceable parts. Maintenance and Service must be completed by qualified agency. WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper maintenance and service could result in death or serious injury. Read this manual and understand all requirements, including use of qualified agency where directed. 1.3 What To Do Should Overheating Occur Do not turn off or disconnect electrical supply to pumps. Shut off gas supply at location external to appliance. 1.4 What To Do If Boiler Or Any Part Has Been Under Water Do not use boiler if any part has been under water. Immediately call a qualified service technician to inspect boiler and to replace any part of control system and any gas control which has been under water. 1.2 Become familiar with symbols identifying potential hazards. This is the safety alert symbol. Symbol alerts you to potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death.! DANGER Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury! WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.! CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Used to address practices not related to personal injury. 2

2 - OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING! WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights burner. Do NOT try to light this burner by hand. Before operating smell all around appliance area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle to the floor. Use only your hand to turn the gas shutoff valve. Never use tools. If valve will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in fire or explosion. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect appliance and to replace any part of control system and any gas control which has been under water.! CAUTION WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. 2.2 TO TURN OFF GAS TO APPLIANCE Set thermostat to lowest setting. Turn "OFF" all electric power to appliance if service is to be performed. Remove front jacket panel. Turn gas shutoff valve handle clockwise to closed position. Handle should be perpendicular to gas pipe. Replace front jacket panel. 2-1 Gas Shutoff Valve 2.1 OPERATING INSTRUCTIONS Stop! Read Safety information above. Set thermostat to lowest setting. Turn " OFF" all electrical power to appliance. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light burner by hand! Remove front jacket panel. Turn gas shutoff valve clockwise to closed position. Handle should be perpendicular to gas pipe. Wait 5 minutes for any gas to clear. Smell for gas, including near floor. If you smell gas, STOP! Follow instructions on this page: What To Do If You Smell Gas. If you do not smell gas, go to next step. Turn gas shutoff valve counter clockwise to the open position. Handle should be parallel to gas pipe. Replace front jacket panel. Turn " ON" electrical power to appliance. Set thermostat to desired setting. If the appliance will not operate, follow instructions TO TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier. OPEN POSITION CLOSED POSITION Gas Shutoff Valve 3

3 - CONTROL MODULE 3.1 Introduction Boiler is equipped with a programmable electronic control and user interface module. Operation with LCD character display module 3.2 Operation Key Description - Manual Lockout Reset - Enter/Exit user menu - Go to previous screen - Select a menu item - Confirm new parameter value - Scroll up to next menu item - Increase value - Scroll down to next menu item - Decrease value 3.3 Status Indication The following status screens can be displayed: Boiler Status Indicator F = Flame Detected SERVICE Reminder P = Central Heating/System Pump On B = Combustion Air Blower On S = Safety Relay Check G = Gas Valve Open D = DHW Pump On Combustion Air Blower Speed Indicator Service Reminder Indicator Boiler in Standby Mode Boiler Supply Water Temperature Indicator Boiler Running in Central Heat mode Boiler Running in DHW mode Lockout Alarm Indicator Error code and short text description displayed. Press Reset key for manual reset. Blocking Error Error code and short text description displayed. Boiler automatically returns to Standby Mode when condition eliminated. 4

3 - CONTROL MODULE 3.4 Sequence of Operation Operational State User Interface Display Explanation Ready for Operation Boiler operates in standby mode until demand for Central Heat (CH) or Domestic Hot Water (DHW) detected. Call for heat. Thermostat Starts Call for Heat CH/System or DHW pump turned ON based on type of heating demand. Heat Exchanger Pump also turned ON. (CH demand illustrated) Pre-Purge Combustion Air Blower energized. Combustion Air Blower speed modulates to prepurge setting for 15 seconds. Trial for Ignition Igniter energized to start sparking sequence. Gas Valve energized to deliver air/fuel to burner. Igniter de-energized. Normal Operation Thermostat Ends Call for Heat Post-Purge Ready for Operation Boiler runs provided all operational and safety devices within limits. Control Module adjusts firing rate to match heating demand. Call for heat ends. Post purge cycle for 30 seconds. Combustion Air Blower modulates to post purge setting. CH/System Pump, DHW pump, and Heat Exchanger Pump operate. Boiler returns to Standby Mode. 5

3 - CONTROL MODULE 3.5 Theory of Operation User Interface Display Explanation STANDBY S t a n d b y : N o D e m a n d 7 5 F Boiler operates in standby mode until Central Heat (CH) or Domestic Hot Water (DHW) demand detected. Access User Menu by pressing Menu key on user interface. User Menu User Menu structure. Use scroll keys to move to desired menu, and press Enter. User Menu M E N U B o i l e r S t a t u s S e t t i n g s C a s c a d e S t a t u s Boiler Status submenu Settings submenu View CH, DHW supply water set point and select control language. Cascade Status submenu Boiler set to function as part of multiple boiler installation; submenu used to view runtime parameters. See Multiple Boiler Manual. B O I L E R S T A T U S C u r r e n t S u p p l y S e t p o i n t 1 6 0 F Supply Temperature set point displayed. CH set point displayed if boiler running in CH mode. Note: Value may change in proportion to outdoor temperature when running in Outdoor Reset mode. DHW supply set point displayed if boiler is running in DHW mode. Boiler Status B O I L E R S T A T U S S u p p l y 1 4 0 F R e t u r n 1 2 0 F D H W S t a t O p e n B O I L E R S T A T U S S y s t e m N. C. F l u e 1 3 2 F O u t d o o r 3 6 F Water Temperature leaving boiler. Water Temperature entering boiler. DHW Thermostat (open or closed) System Water Temperature (if used) Vent System Temperature Outdoor Temperature (if used) B O I L E R S T A T U S B o i l e r P u m p O f f C H / S y s t e m P u m p O f f D H W P u m p O f f Heat Exchanger Pump status (On or Off) CH/System Pump status (if used, On or Off) DHW Pump status (if used, On or Off) 6

3 - CONTROL MODULE User Interface Display Explanation S E T T I N G S C e n t r a l H e a t i n g S e t p o i n t F Setting Range: 104 F to 195 F (40 C to 91 C) Default Value: 140 F (60 C) S E T T I N G S Adjust CH set point to hydronic system design while in Operating in CH Mode = 0 (CH with Thermostat) or 3 (Permanent Demand). In CH Mode = 1 (CH with Thermostat and Outdoor Reset) or 2 (CH with Full Outdoor Reset). Display will change to OD Reset Setpoint and cannot be changed. Control Module calculates set point based on outdoor temperature. Settings D H W S e t p o i n t F Setting Range: 104 F to 195 F (40 C to 91 C) Default Value: 180 F (82 C) DHW set point determines supply water temperature set point when operating in DHW mode. Contact qualified agency to make changes. S E T T I N G S C h a n g e T e m p e r a t u r e U n i t s F a h r e n h e i t F Select temperature unit of measure. Fahrenheit F or Celsius C. S E T T I N G S Select user interface language. C h a n g e L a n g u a g e English E n g l i s h 7

4 - TROUBLE SHOOTING 8

5 - MAINTENANCE! WARNING Asphyxiation hazard. Contact qualified agency if condensate trap is not filled with water. FIGURE 5-1 Condensate Drain Perform general housekeeping and maintenance as specified below. 5.1 Continuous Keep boiler area free from combustible materials, gasoline and other flammable vapors and liquids. Keep combustion air and vent terminations (outside building) free from trash, vegetation and other items capable of blocking flow. FIGURE 5-2 Safety Relief e Valve Discharge Piping Safety Relief Valve 5.2 Monthly Inspect combustion air, vent, and condensate drain piping for deterioration, leaks or sagging. Contact qualified agency, as necessary. Inspect condensate drain trap inside boiler. Follow instructions TO TURN OFF GAS TO APPLIANCE. See section 2. Inspect condensate drain trap for sediment or blockage. Contact qualified agency if cleaning required. Inspect system piping for leaks. Contact qualified agency, as necessary. Check air vent(s) for leakage. Follow OPERATING INSTRUCTIONS to return to normal operation. 5.3 Check According to Manufacturer's Instructions Safety Relief Valve - Refer to manufacturer's instructions.! WARNING Burn and scald hazard. Verify Safety Relief Valve discharge piping run to safe discharge location before conducting maintenance procedure. Contact qualified agency to correct improper piping. System Supply FLOOR Check Local Codes For Maximum Distance To Floor System Return 9 5.4 Annually or Beginning Each Heating Season Contact qualified agency to perform maintenance and cleaning per Installation, Operation and Maintenance manual. Inspection will include examining all flue product carrying areas, vent system, burner and heat exchanger. Will also include filling boiler with water if drained as part of End of Heating Season procedure.

5.5 End of Heating Season, if boiler not used for domestic hot water. Follow instructions to TURN OFF GAS TO APPLIANCE. See section 2. Contact qualified agency to drain heating system (if system does not use antifreeze) and condensate trap if heating system is exposed to freezing temperatures while out of service. 5 - MAINTENANCE 10

6 - USER SERVICE NOTES 11

Installer Information Name: Address: Phone: Email: