_"RETURN. s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _[_SUPPLY

Similar documents
Installation Instruction

Installation Instructions

Fig. 1--Typical Coil Installation

Installation Instructions

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Installation Instructions

Installation Instructions

Installation Instructions

PL Series Premier Indoor Plenum Coils

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Installation Instructions

INSTALLATION INSTRUCTIONS

UPFLOW/DOWNFLOW COILS

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions

C7 Series Split System Uncased Indoor Coils

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Owner s Information Manual

Installation Instructions

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Installation Instructions

Residential Piping and Long Line Guideline

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

INSTALLATION INSTRUCTIONS

Installation Instructions

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Fig. 1 - Unit PHD4 and WPH4

Installation Instructions

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Installation Instructions

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Installation Instructions Part No , Part No Part No

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

Installation Instructions

Installation Instruction

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

Installation Instructions

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

Installation Instructions

INSTALLATION INSTRUCTIONS FOR RCQD COILS

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

Owner s Information Manual

Installation Instructions

EL SERIES INSTALLATION INSTRUCTIONS

Evaporator Coil. Installation Instructions GENERAL

INSTALLATION INSTRUCTIONS

Installation Instructions

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

Evaporator Coil. Installation Instructions GENERAL

Fig. 1 - Unit PGD4, PGS4, WPG4

INSTALLATION INSTRUCTIONS

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Upflow/Downflow A-Coil Specifications

Transcription:

Installation Instructions Upflow--Downflow CC5A Uncased Coil HeatingmCooling CD5A, CD5P Cased Coil CC5A CD5A/CD5P U "RETURN s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _L [_SUPPLY A_2_ Fig. 1--Typical Installation Cased Coils NOTE: Read the entire instruction manual before starfng the installation. This symbol --) indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, t-_-e,electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and National Electrical Codes (NEC) for special requirements. It is important to recognize safety information. This is the safety-alert symbol z_ When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING. and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. z_ WARNING: Before installing or servicing system, always turn off main power to system. There may be more than one disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death. Z_ CAUTION: This coil contains Nitrogen prscharge of 15 PSI. Release of this pressure through the center of the rubber plugs is required before removing the plugs. IMPORTANT: Nitrogen can leak out through the hole that the needle pierced in the plugs. This does not indicate a leaking coil nor warrant return of the coil. Form: IM-CC5A-09 Cancels: IM-CC5A-08 Pdnted in U.S.A. 8-02 Catalog No. 63CC-5A7

Table1_oil MountingPositionin UpflowFieldFabricatedPlenum CCSA COIL FIELD SUPPLIED PLENUM WIDTH (IN./ COIL MOUNTING HEIGHT ABOVE FLANGES (IN.) FURNACE 12-1/2 0 A018, A024, A030 15-13116 3-3/4 15-13/16 0 W024, 2030, A036 19-5/16 3-3/4 19-5/16 0 W036, A042, C048 2_13/16 3-3/4 W042, A060. W048 22-13/16 0 W060 29_/8 0 Coil supportchannelsare mountedon furnace flanges. DiSCardwhen field-fabncated adapters are used. INTRODUCTION Use this instruction manual to install CC5A or CD5A/CD5P indoor coils on upflow or downflow furnaces. (See Fig. 1.) Do net install coil in horizontal position. Models CD5MCD5P are enclosed in a casing. Model CC5A is an unenclosed (bare) coil that requires a field-fabricated or accessory enclosure. IMPORTANT: Some coils are rotated 90 degrees. See Table 2 and Table 3 for lists of the sideways coils. PROCEDURE 1--INSPECT EQUIPMENT File claim with shipper ff equipment is damaged or incomplete. PROCEDURE 2--SELECT INSTALLATION PROCEDURE For uncased coils (CC5A) follow: INSTALLATION a. Upflow CC5A Uncased Coil Installation. See Table 3 for dimensions and accessory part numbers. For cased coils (CD5A) in upflow application follow: b. Upflow CD5A Cased Coil Installation. See Table 2 for dimensions and overhang options. Note instructions for placement of coil easing on furnace. For cased coils (CDSA) in downfiow application follow: c. Dowrdlow CD5A Cased Coil Installation. PROCEDURE 3---INSTALLATION OF FURNACE COILS a. Upflow CC5A Furuace Coil Installation (1.) Mount factory coil support (shipped with coil) directly on furnace flanges to support the coil. IMPORTANT: If uncased coil overhangs furnace refer to Table 1. If table indicates that coil mounting height is zero, use factory supplied coil supports. If table indicates that coil mounting height is other than zero, use field supplied coil supports, at specified height, and block off any bypass air as shown in Fig. 2. (2.) Slide coil into plenum opening. (3.) Cover plenum opening with field supplied front panel. (4.) When installing uncased coil into pro-installed accessory coil casing, use Table 3 to verify correct match. -"> b. Upflow CDSAJCD5P Cased Coil Installation NOTE: The cased coil is designed to fit furnaces of the same width and the next narrower size with no field fabricated adapters. (1.) Set coil in place on upfiow furnace discharge air opening. (2.) Ensure coil is level for proper condensate drainage. Do not tip coil toward condensate drain. Coil casing need not be fastened or screwed to furnace. (3.) When installing narrow coil on wide furnace, create field fabricated adapter. (See Fig. 3.) ---> c. Downflow CD5A/CD5P Cased Coil Installation IMPORTANT: Installing "A" coils rotated 90 degrees from the front of the furnace in downflow applications can cause water blowoff or coil freeze up. This is due to the concentration of air on one coil slab or lack of air on the opposite coil slab. If the airflow is high due to ductwork or other causes, and there is a chance for water blowoff, it is recommended that a 3-in. field-supplied adapter be placed between the coil and the furnace to allow the air to distribute evenly to both coil slabs. (See Fig. 5,) (1.) Set cased coil on supply duct opening. (2.) Place field fabricated 3 in. adapter on coil casing. Adapter should be tapered to fit coil/furnace combination when one of them is larger than the other. (See Fig. 5.) (3.) Set furnace on adapter. NOTE: In downflow installation with a 4-way multipoise furnace, break off perforated duct flanges on furnace. See furnace installation instructions. 2--

(FIELD SUPPLIED) 12) FURNACE A88576 Fig. 2--Adapter Installation When Field Fabricated Plenum Overhangs Furnace NOTE: When removing a coil from its casing in the downflow position, support the coil enclosure with field supplied bracing. (See Fig. 4.) PROCEDURE 4_CONNECT REFRIGERANT PIPING Use accessory tubing package or field-supplied tubing of refrigerant grade, see Product Data information for ordering. Suction tube must be insulated. Do not use damaged, dirty, or contaminated tubing because it may plug refrigerant flow-control device. ALWAYS evacuate the coil and field-supplied tubing before opening outdoor unit service valves. PROCEDURE 5--CONNECT REFRIGERANT, LIQUID, AND SUCTION LINES For matched and mismatched systems, use line sizes recommended in outdoor unit Installation Instructions. The coil can be connected to outdoor units using accessory tubing packages or field-supplied tubing of refrigerant grade. Always evacuate tubing and reclaim refrigerant when making connections or flaring tubing. Leak check connections before insulating entire suction line. Z_ CAUTION: To avoid valve damage to the refrigerant control device while brazing, service valves must be wrapped with a heat-sinking material such as a wet cloth. a. Suction Line Suction line is designed for field sweat comaection. Line is plugged to keep out moisture and dirt. Remove the plugs only when ready to make the connection. A_, CAUTION: If unit is to be installed on system with a thermostatic expansion valve, removal of the indoor coil piston is required. The following section applies to only the CC5A and CD5A coils: b, System Refrigerant Control A refrigerant control device (bypass type piston) is factory supplied with coil. (See Table 2 and Fig. 6.) The piston has a refrigerant metering hole through it, and is field replaceable. The piston shipped with the indoor coil may be different from the piston shipped with the outdoor condensing unit. If this is the case, you must replace the indoor piston. Always use the piston shipped with the outdoor condensing unit. c. Liquid Line (1.) Replace piston if required. Check the piston size stamped into side of brass hex nut. (See Fig. 73 If this piston number does not match required piston shown on outdoor unit rating plate, replace indoor piston with piston shipped with outdoor unit. (2.) When the piston is replace, hand tighten the brass hex nut, then tighten with wrench 1/2 turn. (3.) Remove rubber plug. (4.) Liquid line is designed for sweat connection. CAUTION: Remove Teflon seal during brazing. Replace when fitting has cooled. z_ CAUTION: DO NOT BURY MORE THAN 36 IN. OF REFRIGERANT TUBING IN GROUND. If any section of tubing is buried, there must be a 6 in. vertical rise to the valve connections on the outdoor unit. If more than the recommended length is buried, refrigerant may migrate to cooler buried section during extended periods of unit shutdown, causing refrigerant slugging and possible compressor damage at start-up. NOTE: Wrap a wet cloth around rear of fitting to prevent damage to factory-made joints. --3--

i MIN" FURNACE * CAUTION: Do not mount coil lower than 3 in. minimum or furnace failure may result, A00193 Fig. 3_Adapter Instaliation When Coil Casing Underhangs Furnace A02031 Fig. 4--Coil Enclosure Bracing

DOWNFLOW FURNACE WITH ADAPTER WHEN REQUIRED f / A00192 Fig. 5--Downflow -- High Airflow MODEL NUMBER CDSAA018014 CDSAA024014 CD5AA030014 CDSAW024017 CD5AW030017 CDSAA036017 CDSAW036021 CDSAA042021 CD5AA048021 CD5AC048021 *CDSAW042024 *CD5AW048024 *CD5AA060024 *CD5AW060031 *CDSP060024 *Sideways Coils Table 2----CD5A/CD5P Coil Information METERING DEVICE TONNAGE FLUSH NT TO FURNACE WIDTH (IN,) Pis_n No TV I-1/2 2 2-1/2 2 2-112 3 3 3 1/2 4 4 3-1/2 4 5 5 5 52 59 67 59 67 70 70 78 84 84 78 84 90 90 -- EA36YDI54 14-3/16 14-3/16 14-3/16 17-1/2 17-1/2 17-1/2 21 21 24-1/2 21 24-1!2 24-1/2 24-1/2 31 24-1/2 FITS NET SMALLER FURNACE Equal Ove_g Fac_ Supplied Table 3_CC5A Coil Information MODEL NUMBER TONNAGE METERING DEVICE PISTON NO. MATCHED FURNACE WIDTH (IN.) ACCESSORY CASING CCSAA018014 1-1/2 52 14-3116 KCAKC 1212ECC CCSAA024014 2 59 14-3/16 14-3/16W 19H 21D CCSAA030014 2-1/2 67 14-3/16 12 Ca.sing/Pallet CC$AW024017 2 59 17-1/2 KCAKCI312ECC CCSAW030017 2-1/2 67 17-1/2 17-1/2W 20-1!2H 21D CCSAA036017 3 70 17-1/2 12 Caging/Pallet CCSAW036021 3 70 21 KCAKC 1408ECC CU5AA042021 3-1/2 78 21 21W 22H 21D CUSAC048021 4 84 21 8 Casing/Pallet *CCSAW042024 3-1_ 78 24-1/2 KCAKC 1508ECC *CCSAW048024 4 84 24-1/2 24-I_W 22H 21D *CCSAA060024 5 90 24-1/2 8 Ca._ing/Pallet, KCAKC 1604ECC *CCSAW060031 5 q0 31 31-1/2W 22H 21D 4 C_ing/Pallet *Sideways Coils PROCEDURE 6--MAKE CONDENSATE DRAIN LINE CONNECTION The coil is designed to dispose of accumulated water through built-in condensate drain fitting. Two 3/4 in. female threaded pipe connections are provide in each coil. Install a trap in condensate line of coil, as close to die coil as possible. Make trap at least 3 in. deep and not higher than bottom of unit condensate drain opening. (See Fig. 8.) Pitch Condensate line to open drain or sump. --5 m

13/16-1N. '-BRASS HE /-- STRAINER / NUT / p,_,t,-_,, s-- DISTRIBUTOR j-- PISTON / jr- io _l,_,[ PLUG STAMPED INTO SIDE OF NUT HE BODY \ --+ COPPERTUBE A96248 Fig. 6_Refrigerant Control Device Components for CC5A/CDSA TV PLUG \ B I _-- - -- _COPPER TUBES DISTRIBUTOR -..) Fig. 7--Refrigerant Control Device Components for CD5P NOTE: If unit is located in or above a living space where damage may result from condensate overflow, a field-supplied, external condensate pan should be installed under the entire unit, and a secondary condertsate line (with appropriate trap) should be rtm from the unit into the pan. Any condensate in this external condensate pan should be drained to a noticeable place. As an alternative to using an external condensate pan, some localities may allow the running of a separate 3/4 in. condensate line (with appropriate trap) per local code to a place where the condensate will be noticeable. The owner of the structure must be informed that when condensate flows from secondary drain or external condensate pan, the unit requires servicing or water damage will occur. NOTE: To avoid drainage problems, test the primary drain line by slowly pouring water into the pan. Check piping for leaks and proper condensate drainage. Using the secondary drain as explained in the previous note provides future protection against overflow due to a clogged primary drain. A01446 -Jo--

ENCLOSURE DRAIN TO OPEN DRAIN OR SUMP 3" MIN t Fig. 8--Condensate Trap A88571 --?--

O 2002 CAC/BDP 7310 w+ Mords St., IndianapOlis, IN 46231 imccsa09 --8-- Catalog No. 63CC-5A7