technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Similar documents
technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

TABLE OF CONTENTS RMXS-E8V1B

Air Conditioners. Technical Data FTXS-G

Daikin air conditioners for shops, restaurant and offices

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

EEDEN technical data ERHQ AA. Altherma. Altherma

Air conditioners, heating & cooling for shops,restaurants and offices

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

Daikin air conditioners for your home, shops, restaurants and offices

Air conditioners, heating & cooling for the retailmarket and offices

TABLE OF CONTENTS ERSQ-AAY1

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

technical data air conditioning systems RZQ B8W1B Split Sky Air

Air Conditioning Technical Data RZAG-MV1

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioning Technical Data RZASG-MV1

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

w w w. d a i k i n. e u ATXS-E

TABLE OF CONTENTS ERHQ BAV3

AIR CONDITIONERS, HEATING & COOLING for your home

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

Air Conditioners Technical Data

Daikin air conditioners for your home

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN RXS-F8

Digital Inverter 4 series 8 & 10HP

Daikin air conditioners for your home

for your home FLXS-B Flexi type unit air to air heat pumps

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

for small rooms in multi application

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

for the retail market, hotels, restaurants and offices

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

EDUS Heat Pump - D-Series

Concealed ceiling units

Air Conditioners Technical Data

Air Conditioner SVC MANUAL(Exploded View)

Daikin air conditioners for shops, restaurants and offices

EEDEN technical data ERHQ AA

DESIGN & TECHNICAL MANUAL

SiE Service Manual. Split System Air Conditioners SkyAir R-407C Super Inverter 70 D Series. [Applied Models] SkyAir : Inverter Heat Pump

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

Daikin air conditioners for your home

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

Air Conditioning Technical Data AZAS-MY1

Concealed ceiling unit with medium ESP

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air Conditioners. Technical Data RZQG-L

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Compact 4-way Cassette ( ) Type

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Fully Flat Cassette Design & Genius in one

DESIGN & TECHNICAL MANUAL

EEDEN technical data EKRTR. Altherma. Altherma

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

FXZQ-M 4-Way Ceiling Mounted Cassette Unit (2' 2')

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

DESIGN & TECHNICAL MANUAL

SiBE39-402A. Service Manual. R-410A Heat Pump 50Hz

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Air Conditioners Heating & Cooling

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

DESIGN & TECHNICAL MANUAL

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

MUH-24RV - MSH-30RV -

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioners Heating & Cooling

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU

Transcription:

technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air

Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE03-/2 03/2003 Prepared in Belgium by Goekint Graphics

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV TABLE OF CONTENTS FHYKP-B Features... 2 2 Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications Electrical specifications 3 Dimensional drawings... 6 4 Piping diagrams... 7 5 Wiring diagrams... 8 6 Sound level... 9 Sound level data Sound pressure spectrum 7 Air flow patterns... 0 8 Accessories... 4 Standard accessories Optional accessories 9 Control systems... 7 0 Safety device settings... 8 Installation... 8 For capacity tables, please refer to part II: outdoor units Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV Features + Specially designed for rooms with shallow ceiling voids (unit height: only 2.5cm) + Leaves maximum floor and wall space for furniture, decoration and fittings + Fits flush into each ceiling + Extremely quiet in operation both indoors and outdoors + Automatic air flow director ensures uniform air flow and temperature distribution + Choice between downward air discharge, frontal air discharge or a combination of both + For equal distribution in larger rooms, up to 4 indoor units can be connected to outdoor. They are operated from remote control. + Up to 5 indoor units can be connected to Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room. + The wired remote control has a programmable timer + Centralised control of several units can be achieved via 3 wired controls centralised remote control unified ON/OFF control schedule timer 2 3 q 5 Optional Optional Optional 2 steps 6 r 8 x 6 ) ( 2 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 NOMINAL INPUT Cooling kw 0.92 0.0 0.23 Heating kw 0.59 0.67 0.90 2 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 OUTDOOR UNITS - - - RP7L7V/W-RP7B7T CAPACITY (3) Cooling kw 7.0 NOMINAL INPUT Cooling kw 2.63/2.56/2.62 EER 2.70/2.77/2.7 Twin/triple/double twin application only ENERGY LABEL Cooling D/D/D ANNUAL ENERGY CONSUMPTION Cooling kw/h,35/,280/,30 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 OUTDOOR UNITS - - - RYP7L7V/W CAPACITY (3) Cooling kw 7.0 Heating kw 8.00 NOMINAL INPUT Cooling kw 2.66/2.53 Heating kw 2.63/2.49 EER 2.67/2.8 Twin/triple/double twin application only COP 3.04/3.09 ENERGY LABEL Cooling D/C Heating D/D ANNUAL ENERGY CONSUMPTION Cooling kw/h,330/,265 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 OUTDOOR UNITS - - - RYEP7L7V/W CAPACITY (3) Cooling kw 7.0 Heating kw 8.00 NOMINAL INPUT Cooling kw 2.63/2.62 Heating kw 2.72/2.65 EER 2.70/2.7 Twin/triple/double twin application only COP 2.94/3.02 ENERGY LABEL Cooling D/D Heating D/D ANNUAL ENERGY CONSUMPTION Cooling kw/h,35/,30 Split - Sky Air Indoor Units 3

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 2 Specifications 2 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 DIMENSIONS Unit H mm 25 W mm,0,30 D mm 70 Decoration panel H mm 70 W mm,240,440 D mm 800 WEIGHT Unit kg 30 3 33 Decoration panel kg 8.5 9.5 MATERIAL Unit Galvanised steel plate COLOUR Decoration panel White SOUND LEVEL Sound pressure () high db(a) 40 42 low db(a) 34 35 37 Sound power (2) high db(a) 50 52 FAN Air flow rate (cooling/heating) low db(a) 44 45 47 high m 3 /min 2/2 7/7 low m 3 /min 9/9 0/0 4/4 Speed steps 2 steps Type Sirocco fan Qty x motor output W x 20 x 25 x 45 HEAT EXCHANGER Type Cross fin coil (Multi louver fins and N-hiX tubes) Rows x stages x fin pitch mm 2 x x.75 3 x x.75 Face area m 2 0.86 0.226 AIR FILTER Resin net (with mold resistant) PIPING CONNECTIONS liquid (flare) mm φ6.4 φ9.5 gas (flare) mm φ2.7 φ5.90 drain I.D. mm φ25 drain O.D. mm φ32 INSULATION MATERIAL Heat insulation Both liquid and gas pipes Sound absorbing insulation Foamed polystyrene/foamed polyethylene For outdoor units only: Pair application See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D 4 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 2 Specifications ELECTRICAL SPECIFICATIONS For indoor units only: FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 CURRENT Nominal running current cooling/heating A See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D Maximum running current cooling/heating A See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D 2 For combination indoor units + outdoor units: FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 - - - RP7L7V/W-RP7B7T CURRENT Nominal running current cooling A Maximum running current cooling A Twin/triple/double twin application only See chapters RP-L7/B7 Starting current cooling A For combination indoor units + outdoor units: FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 - - - RYP7L7V/W CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A Twin/triple/double twin application only See chapters RYP-L7 Starting current cooling/heating A For combination indoor units + outdoor units: FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 - - - RYEP7L7V/W CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A Twin/triple/double twin application only See chapters RYEP-L7 Starting current cooling/heating A For indoor units only: FHYKP35BV7 FHYKP45BV7 FHYKP60BV7 FHYKP7BV7 POWER SUPPLY V V V V NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 50 50 50 Voltage V 230 230 230 230 4D028059B NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20 CDB * outdoor temperature: 7 CDB/6 CWB * refrigerant piping length: 7.5m * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 The sound pressure level is measured at.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions). Split - Sky Air Indoor Units 5

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 3 Dimensional drawings 3 FHYKP35-45B Model FHYKP35v45B ja 6.4 jb 2.7 Required space unit (mm) 500 mm or more 20 mm or more 200 mm or more 200 mm or more Fresh air intake position 760 (Ceiling opening) (Suspension position) 4 - M4 hole 4 - M4 hole 50 (Suspension position) 200 (Ceiling opening) front discharge duct connection position Suspension bolt Notes:. Location of unit s name plate + For main body: bottom part of fan hausing inside of air discharge + For decoration panel: service lid face inside of air suction grille Liquid pipe connection - flare ja 2 Gas pipe connection - flare jb 3 Drain pipe connection V.P.25 4 Wire intake 5 Wire intake for remote control cord 6 Grounding terminal (M4 in switch box) 7 Air discharge grille 8 Air suction grille 9 Long life air filter 0 Suspension bracket 000 mm or more Required space 3D027409 FHYKP60-7B Model FHYKP60v7B ja 9.5 jb 5.9 Required space unit (mm) 500 mm or more 20 mm or more 200 mm or more 200 mm or more Fresh air intake position 760 (Ceiling opening) (Suspension position) 4 - M4 hole 4 - M4 hole 350 (Suspension position) 400 (Ceiling opening) front discharge duct connection position Suspension bolt Notes:. Location of unit s name plate + For main body: bottom part of fan hausing inside of air discharge + For decoration panel: service lid face inside of air suction grille Liquid pipe connection - flare ja 2 Gas pipe connection - flare jb 3 Drain pipe connection V.P.25 4 Wire intake 5 Wire intake for remote control cord 6 Grounding terminal (M4 in switch box) 7 Air discharge grille 8 Air suction grille 9 Long life air filter 0 Suspension bracket 000 mm or more Required space 3D027408 6 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 4 Piping diagrams FHYKP35-7B Indoor heat exchanger Model Gas Liquid FHYKP35-45BV7 6.4 2.7 FHYKP60-7BV7 9.5 5.9 4 Field piping φ A C220T-0 Field piping φ B C220T-0 To outdoor unit Indoor unit 4D024085A Split - Sky Air Indoor Units 7

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 5 Wiring diagrams 5 FHYKP35-7B Wired remote control In case of simultaneous operation system. To outdoor unit Indoor unit (master) Indoor unit (slave). D : Terminal F, H : Connector F : Field wiring b : Protective earth (screw) 2. : Field wiring 3. In case of using central remocon, connect it to the unit in accordance with the attached instruction manual 4. Remote controller model varies according to the combination system, confirm technical materials and catalogs, etc. before connecting. 5. Symbols show as follows: RED: red, BLK: black, WHT: white, YLW: yellow, GRN: green, GRY: gray, BLU :blue, ORG: orange 6. Confirm the method of setting the selector switch (SS) by installation manual and engeneering materials, etc. To outdoor unit Switch box -RED, 2-WHITE, 3-BLACK 33A Limit switch (swing flap) 33H Float switch AP Printed circuit board A2P Printed circuit board (Transformer) 230V/6V) CR Capacitor (MF) HAP Light emitting diode (service monitor green) HBP Light emitting diode (service monitor green) MA Motor (swing flap) MF Motor (indoor fan) MP Motor (drain pump) QF Thermo switch (MF embedded) RT Thermistor (air) R2T Thermistor (coil) RyA Magnetic relay (MA) RyF-4 Magnetic relay (MF) RyP Magnetic relay (MP) SS Selector switch (emergency) XM Terminal strip X2M Terminal strip? Signal receiver circuit. Signal transmission circuit Wired remote control RT Thermistor (air) SS Selector switch (main/sub) Connector for optional parts X30A Connector (interface adapter for sky air series) X33A Connector (adapter for wiring) X35A Connector (group control adapter) X40A Connector (ON/OFF input from outside) 3D027407 NOTES Line voltage wiring Control circuit wiring 2 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. 3 Use copper conductors only. 4 See wiring diagrams for details. 5 Install fuse and mainswitch for safety. 6 All field wiring and components must be provided by a licensed electrician. 7 The unit shall be grounded in compilance with the applicable local and national codes. 8 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. 9 Never share a common power supply with other equipment. V, Model Power supply 50Hz 220V-240V W, Model Power supply 3N 50Hz 380V-45V T, Model Power supply 50Hz 230V Main switch Main switch Main switch Fuse Fuse Fuse H05VV U4G 4D00992A 8 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 6 Sound level 6- Sound level data Sound pressure level Sound power level 50Hz-230V Model H L Measuring location H L cooling/heating cooling/heating cooling/heating cooling/heating 6 6- FHYKP35BV7 40/40 34/34 Location of microphone 50/50 44/44 FHYKP45BV7 40/40 35/35 50/50 45/45 FHYKP60BV7 42/42 37/37 52/52 47/47 FHYKP7BV7 42/42 37/37 52/52 47/47 6-2 Sound pressure spectrum FHK35BZV7 FHYKP35BV7 FHK45BZV7 FHYKP45BV7 Octave band sound pressure level H (230V) Octave band sound pressure level H (230V) L (230V) L (230V) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D027876 Octave band center frequency (Hz) 4D027875 Octave band center frequency (Hz) FHK60BZV7 FHYKP60-7BV7 Octave band sound pressure level H (230V) NOTES approximate threshold hearing for continuous noise L (230V) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Sound levels are valid at nominal operation conditions. 4D027877 Octave band center frequency (Hz) Split - Sky Air Indoor Units 9

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 7 Air flow patterns 7 FHYKP35-45BV7 Cooling - air velocity distribution Air flow direction: 30 (downward) Cooling - air temperature distribution Air flow direction: 30 (downward) 4D028539 0 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 7 Air flow patterns FHYKP35-45BV7 Heating - air velocity distribution 7 Air flow direction: 65 C (downward) Heating - air temperature distribution Air flow direction: 65 C (downward) 4D028540 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 7 Air flow patterns 7 FHYKP60-7BV7 Cooling - air velocity distribution Air flow direction: 30 (downward) Cooling - air temperature distribution Air flow direction: 30 (downward) 4D028543 2 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 7 Air flow patterns FHYKP60-7BV7 Heating - air velocity distribution 7 Air flow direction: 65 C (downward) Heating - air temperature distribution Air flow direction: 65 C (downward) 4D028544 Split - Sky Air Indoor Units 3

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 8 Accessories 8 8-8- Standard accessories Name j Clamp j2 Paper pattern for installation j3 Drain hose Insulation for fitting Quantity pc. pc. pc. of each Shape j4 For gas pipe j5 For liquid pipe Name Quantity Sealing pad of each Shape j6 Large j7 Small Name j0 Installation guide j Washer for hanging bracket j2 Clamp Quantity 2 each 8 pcs. 7 pcs. Shape Screws x 4 Name j3 Insulation for hanging bracket j4 Air outlet blocking pad Quantity 4 pcs. pc. (Other) + Installation manual Shape + Operation manual + Screws for fixing panels are attached to the decoration panel. 4 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 8 Accessories 8-2 Optional accessories Name of option Remark FHYKP-BV7 35 45 60 7 Decoration panel BYK45FJW BYK7FJW Panel spacer KPBJ52F56W KPBJ52F80W Air discharge blind panel KDBJ52F56W KDBJ52F80W Replacement long-life filter Resin net KAFJ52F56 KAFJ52F80 Discharge grille KDGJ52F56W KDGJ52F80W Flexible duct with shutter KFDJ52F56 KFDJ52F80 Remote control Wired type BRCD57 Infrared type Heat pump BRC4C6 Cooling only BRC4C63 Central remote control DCS302B5 Unified ON/OFF control DCS30B5 Schedule timer DST30B5 Option PCB for external electrical heater, humidifier and/or hour meter EKRPB2 Adapter for wiring (interlock for fresh air intake fan) KRPB5 Group control adapter KRP4A5 Interface adapter for Sky Air series DTA02A52 Remote sensor KRCS0- Remote ON/OFF, forced OFF EKRORO 8 8-2 DU423-900B Split - Sky Air Indoor Units 5

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 8 Accessories 8 8-2 8-2 Optional accessories Specifications EKRORO Wire specifications Connector (White) connect to indoor PCB (X40A) White connect to on/off switch AWG24 0.22mm 2 White Operating method ON* Switch Unit Input Remote control Standard setting: forced off Alternative setting: on/off OFF ON OFF ON OFF ON OFF * Input ON = closed contact. Forced off Input on stops operation + disables control Input off enables control On/off operation Input off on: starts operation, remote control is still enabled. Input on off: stops operation, remote control is still enabled. Selection of FORCED OFF and ON/OFF operation Setting Mode NO First code NO Second code NO Forced off 2 (22) 0 On/off operation 02 4TW2394-6 Split - Sky Air Indoor Units

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 9 Control systems 9- Wired remote control BRCD57 9 9-5 x 0 (Round end slit) 6.5 x 9 (Round end slit) Cover closed 5 x 7 (Round end slit) HoleJ5 Cover open 3TW2365-2 Split - Sky Air Indoor Units 7

Ceiling Mounted Corner Cassette R-407C FHYKP35-7BV 0 Safety device settings 0 FHYKP-BV7 Model Safety devices 35 45 60 7 Fuse Fan motor thermal fuse ( C) Fan motor thermal protector ( C) OFF: 20±5 ON: 05 or less OFF: 20±5 ON: 05 or less OFF: 20±5 ON: 05 or less OFF: 20±5 ON: 05 or less DU423-90H Installation Names and functions of parts ja Indoor unit jb Outdoor unit jc Infrared remote control jd Inlet air je Discharged air jf Air outlet jg Air flow flap (at air outlet) jh Refrigerant piping, connection electric wire ji Drain pipe j Air inlet The built-in air filter removes dust and dirt. jk Ground wire Wire to ground from the outdoor unit to prevent electrical shocks. jl Drain pumping out device (built-in) Drains water removed from the room during cooling 8 Split - Sky Air Indoor Units