TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

Similar documents
TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Technical documentation DTR

Technical documentation

Technical documentation: S1 S2 S3 S4

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

Technical documentation DTR. Farmer HCF in EPP casing

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

PRICE LIST VALID FROM 1st October 2017

HEATING AND COOLING DEVICE AGC

Reventon Group [Ltd.] 3B Montażowa Street, Bielsko-Biała, Poland VAT ID tel.

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

1.1 VTS: number 1 in the world pillars of success

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

Gas heaters and convectors ROBUR

USERS MANUAL FOR GAS BOILERS

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Oil Filled Radiator. Model: SH60010 (all colours) Help line: This product is only suitable for well insulated spaces or occasional use

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CNBOP-PIB Standard Fire Protection

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

How to install and use your storage heater

ATM Lighting sp. z o.o

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

High temperature air-to-water heat pumps

TTV 4500 / TTV 4500 HP / TTV 7000

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Air curtain.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

WHE 2.24 / WHE 2.24 FF

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

200W Frostwatch Radiant Heater Operation Manual

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

OIL COOLER INSTRUCTION HANDBOOK

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

TSL hand dryer. installation + maintenance

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

CAW Ceiling-mounted fan heaters for hot water

Roof top SPACE RPC 450Z R407C M011

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Instruction FH-CWP Thermostat

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

1300W Pressure Washer RACHP133A

O P E R A T O R S M A N U A L M O D E L S PR 32 / 98 TRANSLATION OF THE ORIGINAL MANUAL

ATM Lighting sp. z o.o

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

with insulated heating elements for water heaters INSTALLATION AND USER MANUAL WARRANTY CARD

Specification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

THERMASREG TR 040 THERMASREG TR 060

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Drying Ovens Models F3 - F6 - F9

INDIRECT WATER HEATERS

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

floor convectors PRACTIC floor convectors

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

No. 1 in Europe New on offer air curtain GUARD

The guarantee on this appliance is valid for 12 months from the first day of installation.

Drying Ovens for Fluxes Models F100 F200 - F400

DH-Direct Fired Poultry Farm Diesel Heater

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

USER S GUIDE UTE202NP SERIES NON PROGRAMMABLE ELECTRONIC THERMOSTAT

INSTRUCTIONS AND WARRANTY

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

INSTALLATION AND OPERATION MANUAL

Air-Water heat pump Small GT

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Transformer oil coolers BETA & CETA

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

BSK-RPR Fire Damper. Additional operating instructions according to

Transcription:

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

ENG Technical documentation Table of contents 1. INTRODUCTION 1.1 PRECAUTIONS 1.2 TRANSPORT 1.3 PACKAGE CONTENT 1.4 USE AND PRINCIPLE OF OPERATION 2. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL DATA 2.1 CONSTRUCTION 2.2 DIMENSIONS 2.3 TECHNICAL DATA 3. ASSEMBLY 4. INSTALLATION INSTRUCTIONS 5. PRECAUTIONS & WARNINGS 6. CONTROLS 7. CONNECTION SCHEMES 8. TERMS OF WARRANTY 8.1 WARRANTY CARD 8.2 WARRANTY FORM 8.3 SERVICE FORM Axial blowing fan: protective grid made of steel wire galvanized, metal blades. The motor has got the safety degree IP 54. Rate current 0,42A- 0,82A. 1-phase device, 1-stage fans. Rotating mounting bracket: made of steel, element for mounting the device on the wall or ceiling. Solid and durable construction, possible to assemble device in parallel on the angle 60. Possible rotation horizontally. Fixed holders: made of steel, element for mounting the device on the wall or ceiling. Solid and durable construction, possible to assemble device in parallel on the angle 60 and 45. 2.2 DIMENSIONS 1. INTRODUCTION Thank you very much for purchasing Reventon Group device. We would like to congratulate you on excellent choice. 1.1 PRECAUTIONS The buyer and the user of the device should read carefully the following instructions and proceed to the content recommendations. Proceeding due to the following instruction guarantees the correct usage and safety. In case of any doubts please contact the producer. The producer reserves the rights to make changes to the technical documentation without previous notice. The producer is not responsible for the damages which occur due to improper installation, not keeping the device in repair or using the device out of line. The installation should be carried out by the professional installers, who possess the qualifications to install these types of devices. The installers are responsible for making the installation as instructed in the technical data. Regulations and safety rules must be followed. During the installation, use, service and periodical inspections all regulations and safety rules must be followed. In case of unserviceable please plug out the device and contact with the authorized person or the producer. 1.2 TRANSPORT During the acceptance of goods, it is needed to check the device to exclude any damages. During the transport, it is needed to use the proper equipment, it is necessary to carry the device by two people. In case of any damages please fill in the damage report in presence of the supplier. 1.3 PACKAGE CONTENT - Air water heater - Operation and maintenance manual and warranty card 1.4 USE AND PRINCIPLE OF OPERATION Devices Reventon Group S series are used to heat spaces such as: production halls, warehouses, commercial room, service spaces, garages, workshops, greenhouses, tents, shops, malls, shopping malls and churches. Air water heaters must be connected to central heating system. Application of modern technologies in Reventon Group devices guarantees high effectiveness and comfort of the consumption. Original colors of the devices match to every interior. The device is made very precisely and will work smoothly for many years. * The product has got the two years of warranty. 2. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL DATA 2.1 CONSTRUCTION - Casing - Air stators - Heating coil - Axial blowing fan - Rotating mounting bracket 2.3 TECHNICAL DATA TECHNICAL DATA Nominal heating capacity water 90/70 C and inlet air temperature 0 C. Heating power range Maximum airow. Maximum range of air stream Number of rows in heater Weight including water/ without water Capacity of water Unit of measure kw kw m³/h m number dm³ Air temperature rise. * C Maximum temperature of heating agent C Maximum operating pressure Rated current Power supply voltage Motor power Motor speed MPa A V/Hz Motor IP - Ferrules diameter Rev./min S1 S2 S3 16,7 29,4 52,1 59,3 7-17 13-29 23-52 26-59 10-12 1743 2973 2973 4430 10-18 10-18 10-25 1 2 3 2 kg 15,5/15 22,3/21 24,9/23 29/27 W 0,5 1,3 1,9 2 26,7 27,5 48,7 37,5 110 110 110 110 1,6 1,6 1,6 1,6 0,42 0,66 0,66 0,82 230/50 230/50 230/50 230/50 80 150 150 180 1400 1400 1400 1400 54 54 54 54 3/4 3/4 3/4 3/4 * Temperature rise according to parameters: water 90/70 C and inlet air temperature 0 C. ** The measurement at 5 m from the unit Casing: made of galvanized steel casing, powder painted in RAL 9005 color. Air stators: made of galvanizes steel, powder painted in RAL 7048 color. It is possible to adjust manually the air stators to achieve the needed direction of the air flow. Heating coil: made of aluminum and copper. The temperature of the heating factor is 110 C; maximum pressure 1,6 MPa; headers diameter ¾. Depending on the water heater model we offer 1, 2 and 3 heating coils. Waga

S1 S1 S1 90/70 80/60 70/50 22,2 19,4 16,7 14,2 11,7 19,6 16,9 14,3 11,8 9,4 17,1 14,4 11,9 9,44 7,09 12,8 19,8 26,7 33,4 40 9,1 16 22,8 29,5 36,1 5,3 12,2 19 25,6 32,2 0,98 0,85 0,74 0,62 0,52 0,86 0,74 0,63 0,52 0,41 0,75 0,63 0,52 0,41 0,31 33 26 22 16 11 27 23 17 12 9 23 17 12 10 6 S1 S2 S2 50/30 90/70 80/60 12 9,45 7,03 4,69 2,44 38,8 34 29,4 24,9 20,7 34,5 29,8 25,3 20,9 16,8-2,3 4,5 11,2 17,8 24,2 13,7 20,6 27,5 34,2 40,8 9,9 16,8 23,6 30,3 36,8 0,52 0,41 0,31 0,2 0,11 1,71 1,5 1,29 1,1 0,91 1,52 1,31 1,11 0,92 0,74 13 10 6 5 2 24 19 14 11 7 20 15 11 8 5 S2 S2 S3 70/50 50/30 90/70 30,2 25,6 21,1 16,9 12,8 21,4 17 12,8 8,7 4,71 68,9 60,3 52,1 44,3 36,8 6,2 13 19,7 26,4 32,8-1,4 5,3 12 18,4 24,7 39,8 44,3 48,7 52,9 56,9 1,32 1,12 0,92 0,74 0,56 0,93 0,74 0,55 0,38 0,2 3,04 2,66 2,29 1,95 1,62 16 11 8 5 3 9 6 3 2 1 52 41 31 23 16 S3 S3 S3 80/60 70/50 50/30 61,5 53 45 37,4 30,1 54 45,8 37,9 30,5 23,3 38,9 31,1 23,6 16,3 9,23 33,3 37,8 42,1 46,3 50,2 26,8 31,3 35,5 39,5 43,4 13,8 18 22 25,9 29,3 2,7 2,33 1,98 1,64 1,32 2,36 2 1,66 1,33 1,02 1,69 1,35 1,02 0,71 0,4 43 33 24 17 12 35 26 18 12 7 20 13 8 4 1 90/70 80/60 70/50 78,6 68,7 59,3 50,3 41,7 69,9 60,2 51 42,2 33,8 61,1 51,7 42,7 34,1 25,8 26 31,9 37,5 43 48,3 21 26,7 32,3 37,7 72,9 15,8 21,5 27 32,3 37,5 3,46 3,03 2,61 2,22 1,84 3,07 2,64 2,24 1,85 1,48 2,67 2,26 1,87 1,49 1,13 38 29 22 16 12 31 23 17 12 8 24 18 13 8 5 50/30 43,4 31,1 25,8 17,6 9,5 5,4 18 16,3 21,5 26,4 1,88 1,35 1,12 0,76 0,41 13 13 5 3 1

3. ASSEMBLY Air water heaters Reventon Group S series can be assembled on the wall or ceiling via rotating mounting brackets. The drawings below show the ways of assembly. In the bigger accommodation, it is recommended to assemble more than one device. Follow the parameters which are provided on the drawings. - Before plugging the electric supply check the leak tightness. - The device does not consist of the anti-frost protection. The temperature in the room should not go below 0 C. In such case please empty the device out of water. - It is recommended to check the electric installation before the first start. - It is recommended to use the external current deferential protection. - After the turn off, the elements of device may be warm. - After operating time of the device, please utilize it concerning the local norms and regulations. It is recommended to clean the device periodically: źheating coil blow through by compressed air, źfan casing and blades clean form the dirt. - If the device is not used for a longer time disconnect the voltage supply. - The device is transported with the closed air stators. It is essential to open them in 30 % before first start. Not keeping to the following recommendation may cause the damages of the fan. Reventon Group devices can be assembled on the wall or ceiling via rotating mounting bracket. It is possible to assemble the device in parallel on the angle 60. Please follow the parameters as shown below. - Opening the air stators must be made by two hands in parallel. Not keeping to the following recommendation may cause the damages of the air stators. REGULACJA STOPNIA NACHYLENIA PRZY UŻYCIU UCHWYTÓW MONTAŻOWYCH 4. INSTALLATION INSTRUCTIONS The installation should be made by the qualified staff, who possess the needed rights to install electrical devices, as instructed in the following documentation. The duct size for air water heaters Reventon Group S should be chosen by the designer. 5. PRECAUTIONS & WARNINGS All works concerning electrical installation should be made by the qualified staff, who possess the qualifications due to the domestic and local norms. These recommendations include service and disassembly as well. Not following to the recommendations may cause electrocution, device damages or its incorrect work. - Before service or exchange of the device it is obligatory to cut off the current supply. - Do not cover the inlet and outlet of the device. While plugging the device to the water installation do remember to hold its stub pipes by pipes spanner, not keeping to the recommendation may cause the damages of the heating coil. Outlet Inlet - Do not use the device in room with high moisture or close to the water basin. - Do not install, service the device with wet hands or barefoot. - Do not use the device in room with flammable fumes, gas and high concentration of dust. - The device should be kept out of reach of children and animals. - During the assembly use the filter on the hydraulic supply. - The device should be secured against pressure increase in the water installation.

6. CONTROLS To make easier the usage of the Reventon Group devices we also offer the additional controls: Fan speed controller HC 0,6A 5 control levels: 0-70-85-105-145-230V Allowable current output: 0,6 A Protection: wyłącznik termiczny Dimensions: 118mm x 78mm x 55mm Weight: 0,7kg Fan speed controller HC 1,2A 5 control levels: 0-70-85-105- 145-230V Allowable current output: 1,2 A Protection: thermal switch Dimensions: 126mm x 176mm x 56mm Weight: 1,3kg Fan speed controller HC 3A Fan speed controller HC 11A 5 control levels: 0-80-120-140-170-230V Allowable current output: 11 A Maximum ambient temperature 40 C Maximum temperature controller 70 C, limited motor protection. Dimensions: 240 mm x 190 mm x 125 mm Weight: 8,1 kg Fan speed controller HC 14A 5 control levels: 0-80-120-140-170-230V Allowable current output: 14 A Maximum ambient temperature 40 C Maximum temperature controller 70 C, limited motor protection. Dimensions: 240mm x 190 mm x 125 mm Weight: 10,2kg Two-way valve with actuator ¾ Power: 230V 50/60 Hz Total current: <0,25A Input: <0,015 (3,35VA) Auxiliary microswitch: 5A Maximum operating temperature: 60ºC Class of insulation: double Degree of protection: IP40 Closing time: 5-6 min Adjustment stroke: 3,6 mm 5 control levels: 0-70-85-105- 145-230V Allowable current output: 3 A Protection: thermal switch Dimensions: 126mm x 176mm x 56mm Weight: 1,3kg Obudowa w stopniu ochrony : IP 54 Module relay RM-16A Relay module RM-16A opens and closes the circuit to affect the work of other devices. It can be used to connect a receiver with higher power than the relay in the controller allows. Maximum rated current is 16A. Fan speed controller HC 5A 5 control levels: 0-80-120-140-170-230V Allowable current output: 5 A Maximum ambient temperature 40 C Maximum temperature controller 70 C, limited motor protection. Dimensions: 125 mm x 175 mm x 100 mm Weight: 3,8 kg Fan speed controller HC 7A przeznaczony do zmiany prędkości obrotowej wentylatorów jednofazowych sterowanych napięciowo w przemysłowych systemach nawiewnych i grzewczych. Power supply: 230 V AC Maximum rated current: 16 A Input NO/COM Input SL Connection of a regulator with the voltage relay 230 V Dimension [mm] W-47 H-47 D-2 Programmable room thermostat HC Number of temperature levels: 1 Hysteresis: 0,50 /1ºC Power: 2 baterie AA Switching: 230 VAC/50Hz 5(3) A Operating temperature range: 0-40ºC Temperature control range: 5-30ºC Accuracy of temperature: 0,2ºC Number of programs: 9 5 control levels: 0-80-120-140-170-230V Allowable current output: 7 A Maximum ambient temperature 40 C Maximum temperature controller 70 C, limited motor protection. Dimensions: 240 mm x 190 mm x 125 mm Weight: 6,4 kg Manual thermostat HC Thermostat is a device that is designed to maintain a pre-set room temperature. Operating temperature: 0-40ºC Temperature control range: 10-30ºC Accuracy of temperature: 1ºC Number of programs: 1 Rated current: 3A COOPERATION WITH EQUIPMENT Model REVENTON S1 REVENTON S2 REVENTON S3 REVENTON HC 0,6 A 1 0 0 0 HC 1,2 A HC 3 A HC 5 A HC 7 A HC 11 A HC 14 A 2 7 11 16 26 33 1 4 7 10 16 21 1 4 7 10 16 21 1 3 6 8 13 17 RM-16A 38 24 24 19

7. CONNECTION SCHEMES b) Defects through: - improper usage and service; - using the device in the improper conditions (too high humidity, too high or too low temperature, impact of the surrounding, sun etc.); -modified equipment that has been modified or repaired without written agreement of the producer; - connecting additional equipment, which is not recommended by the producer or inconsistent with the technical documentation; - improper power supply. c) Elements which wear and tear such as discolor or using. VI.All changes in record in the warranty terms or any constructive modifications, independent service outside the Reventon Group Sp. z o.o. service or use, uncaring, makes the warranty not valid. VII.To obtain the service it is needed to send to the producer warranty card with the signature, document confirming the purchase, (copy of the invoice) and correctly filled the warranty form. VIII. Not following to any of warranty regulations makes the warranty not valid. A IX.All correspondence, returns, complains should be send to the following address: Reventon Group Sp. z o.o. 3B Montazowa Street, 43-300 Bielsko-Biała, Poland or e-mail: serwis@reventongroup.eu The producer reserves the rights to make changes to the technical documentation without previous notice. PE- protective earthing, duct yellow-green colour; N- neutral, duct black-black colour; L- phase duct, duct brown colour; Empty clamp, duct blue-black colour. 8. TERMS OF WARRANTY I.Reventon Group Sp. z o.o. [Ltd.] 3B Montazowa Street, 43-300 Bielsko- Biała,Poland, is the producer of the Reventon Group brand. The warranty concerns the following devices and it is valid for 2 (two) years: - air water heater Reventon S1 17kW 230V - air water heater Reventon S2 29kW 230V - air water heater Reventon S3 52kW 230V - air water heater Reventon 59kW 230V II. Warranty is valid in the European Union. III.The terms of warranty are valid from purchasing the device (the date issuing a document confirming the purchase of the device) but not further than 30 (thirty) months from leaving the producer s warehouse. IV.The defects revealed during the warranty period will be removed free of charge in 14 working days. The service will be done by the installation company due to the terms included in warranty card. The elements will be supplied by the Reventon Group Sp. z o.o. during the warranty period. V.Warranty does not cover the parts of the device subject to normal maintenance and the cases as below: a) Mechanical defects, damages from the impact of the improper transportation or damages through improper storage.

Warranty card : : : : : Reventon Group [Ltd.] 3B Montazowa Street, 43-300 Bielsko-Biała, Poland

Reventon Group Sp. z o.o., ul.montażowa 3B, 43-300 Bielsko-Biała, Polska, www.reventongroup.eu