Mounting Layout ITALIAN FOG SYSTEMS QUALITY EXPERIENCE.

Similar documents
FOG AND MISTING SYSTEMS

Mantellatura Body. Tav. 36. KP 175 Rev page 76

CABINETS ECOSTORE SUPER PREMIUM

ESP 250 ELENCO ESPLOSI RICAMBI. INVOLUCRO / Shell assy. GRUPPO FRIGORIFERO / Cooling system. EVAPORATORE / Evaporator.

Application COOLING PRINCIPLE. Fig. 2

REVISIONE PROGRAM. N.

REVISIONE PROGRAM. N.

CP 30 sc E CP 30 sc EW tavola 1 view 1 B

IT 66 ESS IT 66 EWSS tavola 1 view 1 A

Controllers for refrigeration EVBOX1

Controllers for refrigeration EVBOX1 data-logging extension

Sifoni Cromati e pilette Chrome plated siphons and waste

LAVASTOVIGLIE SOTTOTAVOLO CON ADDOLCITORE UNDERCOUNTER DISHWASHER WITH WATER SOFTENER LS5 WS / WT4 WS

CP 70 E CP 70 EW tavola 1 view 1 B

CP 315V Z EM series tavola 1 view 1 B

CP215V modello costruttivo model type SV2

I-ONE 120 INU No Part Name Descrizione Wall Mounting Frame Dima di fissaggio GR Rear Case Fondo unità interna GR Evaporator Assy

SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO

Hot Box 25/350-25/500

Dati Tecnici Technical Data

B2009 compact. Dal 1901 COD

B2009 compact. Dal 1901 COD

SP GW...B. Ventilconvettori "Hydronic Global Cassette" "Hydronic Global Cassette" Fan Coil. Parti di ricambio / Spare parts

displei studio baciocchi 2010

Ø24 Ø34 CP POLINI WITH KNOB CHOKE ELASTIC CONNECTION POLINI CP STARTER ARIA A POMELLO, ATTACCO ELASTICO

RETTANGOLO J RETTANGOLO J

CONCEPT LINE COUNTERS without TOP

ROLL IN FULL DOOR 0/+10 C ROLL IN WITH "SMART CONTROL"

Fan heater Panther 6-15 Efficient fan heater for medium size premises

NUC/ EUC/ KUC/ NUCA/ ZUCA/ FUCA/ EUCA

BLAST CHILLER/FREEZER 10GN 2/1 LENGTHWISE TOUCH LINE USA

hladnjaci Za vino 126

04/2015. Mod: CFG 202. Production code:

USER MANUAL and INSTALLATION MANUAL

ROLL IN 1600 LT Refrigerator

Installation Manual BCS 1000/1500

Fonderie Sime S.p.A. - Via Garbo, Legnago (VR) - Tel Fax PLANET DEWY 30 BFR

TERMOREGOLAZIONE THERMAL REGULATION

X-STEEL 316 A TIMELESS STYLE, A PEERLESS BEAUTY STILE SENZA TEMPO, BELLEZZA SENZA EGUALI

FORNO CONVEZIONE-VAPORE ELETTRICO 20GN1/1, 20GN2/1

EDI 5. Control Box Wash Arm. Wash Pump Rinse Assembly Rinse Aid Injector Detergent Injector Detergent Pump Optional 2009 cod.

Installation Manual BCS2000/3000

SIRENE ANTINCENDIO E EVACUAZIONE FIRE ALARM AND EVACUATION SOUNDERS

HUMIDITY AND TEMPERATURE CONTROLLER

MICROCASA A LEVA 1GR. CARROZZERIA +VARIE CASING+VARIOUS. Italian Espresso Coffee Machines

HEAVY DUTY COUNTERS "SMART"

GUIDA TASCABILE POCKET GUIDE

SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO GAS BOILING PAN WITH INDIRECT HEATING 60 L PENTOLA GAS RISCALDAMENTO INDIRETTO 60 L

Design guidelines for landscape integration in territorial transformation

LAMBDA ECHOS HE small

Gateway Bacnet Chiller NRL,NRK series

Politecnico di Torino. Porto Institutional Repository

DOX25M. Water Doser Mixer USER S INSTRUCTION MANUAL

TECHNICAL EQUIPMENTS FOR WASTE WATER TREATMENT PLANTS SOA

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS HP. Domestic Gas Boilers GENUS HP. R EN - Edition 05-12/10/2011

SPAGNOL takes care of growing things. We are designers by nature. Air-conditioning. Easyclim DESIGNED&PROJECT BY SPAGNOL SPAGNOL

SIRENE ANTINCENDIO E EVACUAZIONE FIRE ALARM AND EVACUATION SOUNDERS

R T V, 1~/PE Hz 13 A 3 kw

USER and INSTALLATION MANUAL

ENOITALIA MACCHINE ENOLOGICHE WINE PRODUCTION MACHINERY

RAUS air-cooled condensing units

VACUUM EVAPORATORS ME SERIES

Connect BASE MIX WARNINGS AND SAFETY DEVICES

rml Retractable CIP Spray Nozzles Manual Manual Installation, Operating and Commissioning ORIGINAL FILE

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

Filtro industriale Mini MJC. Per polveri chimiche

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

LDW245JMTI/A TM485A2,4 MAX 10MT SUP

Installation and use Indicazioni per l installazione e l uso MARINE TOILET SISTEMA VORTEX. level regulation 9 MADE IN ITALY

GENERATORI D ARIA CALDA PENSILI A COMBUSTIONE INDIRETTA INDIRECT COMBUSTION SUSPENDED SPACE HEATERS

Section 11. Heating and Ventilation. Heating & Ventilation Systems. 1 of 6

Cheese Caves. Chris Banker May

B COD REV.02

CLEANING SYSTEM FOR FIBRE

Catalogo ricambi Spare parts catalogue

Service part catalogue SelfCooking Center 102 validity: 10/2008

Precision Storage Vessels OIL / GAS FIRED WATER HEATERS

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

Service part catalogue

Miscelatore monocomando lavello con canna girevole abbattibile. Single-control mixer for sink with swivel and knock-down spout.

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

PART 1 - GENERAL 1.1 WORK INCLUDED

Manufacturing Innovative Cooling Solutions Since 1994

FORMENTERA CTN RTN CTFS RTFS

ESP 2000 ELENCO ESPLOSI RICAMBI. INVOLUCRO / Shell assy. GRUPPO FRIGORIFERO / Cooling system. EVAPORATORE / Evaporator

S170 - SOLAR STORAGE-TO-BOILER CONNECTION KIT WITH THERMAL INTEGRATION

Manual. Electro Plus. Use and Installation ELECTRIC TOWEL HEATER

08/2012. Mod: BCC/22TD-GR. Production code:

RICAMBI DOCCIA E IDRAULICI

SIRENE ANTINCENDIO E EVACUAZIONE FIRE ALARM AND EVACUATION SOUNDERS

THE NEW MECHATRONIC LOCK CONNECT TO SECURITY

HIGH AND LOW PRESSURE COMPRESSORS FOR PURE BREATHING AIR - NITROX AND TECHNICAL GASES CATALOGUE BOOSTER COMPRESSORS

GLUE APPLICATION SYSTEMS DESIGN AND DEVELOPMENT

MITICA. Dal 1901 COD

Supercapri GELATO PRO

NO. 1 IN PIPEWORK SYSTEMS THE MODULAR PIPEWORK SYSTEM

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

linea mini catalog parts

Transcription:

Mounting Layout ITALIAN SYSTEMS QUALITY EXPERIENCE

80 cm. Polyamide pipes line and Premium pump ALIMENTAZIONE IDRICA Schema esemplificativo installazione Linea Polyamide con pompa Premium ANTISCALE DEVICE ANTICALCARE HIGH PRESSURE FILTER FILTRO ALTA PRESSIONE DRAIN VALVE DI SCARICO EC200008 max. 250 cm. MOST COMMON PARTS FOR POLYAMMIDE LINE COMPONENTI STANDARD PER LINEA POLYAMMIDE Clamp IF400007 3/8 poly line union IF300001 10/24 0.2 Nozzle IF130209 Clamp IF400007 LINE END FINE LINEA 250 cm. 1

max. 650 cm. Schema esemplificativo di installazione ALIMENTAZIONE IDRICA IF600001 cooling fans with polyamide pipeline Ventilatori raffrescanti IF600001 con linea polyamide 1) Fans should be mounted 7 meters far from each other and no more than 10 meters 2) Fans must be mounted at 240/300 cm. height from floor 1) La distanza consigliata tra i ventilatori è di 7 metri e non deve superare i 10 metri 2) Montare i ventilatori a parete ad una altezza compresa tra 240 e 300 cm. dal suolo EC600001 FAN WITH MISTING RING VENTILATORE EC600001 CON GHIERA PORTAUGELLI BALL VALVE max. 850 cm. EC600001 FAN OSCLILLATION AREA DI AZIONE VENTILATORE EC600001 AREA COVERAGE AREA DI COPERTURA 50-60 m2 max. 850 cm. 90 Oscillation Non oscillating mode 45 Oscillation 90 Oscillation 90 Oscillation 45 Oscillation max. 650 cm. 14 mt. 21

max. 500 cm. Schema esemplificativo di installazione ALIMENTAZIONE IDRICA IF600051 cooling fans with polyamide pipeline Ventilatori raffrescanti IF600051 con linea polyamide 1) Fans should be mounted 4 meters far from each other and no more than 8 meters 2) Fans must be mounted at 240/300 cm. height from floor 3) Install misting ring with 5 mm pipe for better oscillation 1) La distanza consigliata tra i ventilatori è di 4 mt. e non deve superare gli 8 metri 2) Montare i ventilatori a parete ad una altezza compresa tra 240 e 300 cm. dal suolo 3) Utilizzare il tubo 5 mm sulle ghiere per agevolare l oscillazione 3/8" PIPE TUBO 3/8" (9.52 mm) EC600051 FAN WITH EC600003 MISTING RING VENTILATORE EC600051 CON GHIERA EC600003 max. 700 cm. EC300001 + EC300077 WATER TAP + EC300076 EC300076 5 mm PIPE TUBO 5 mm EC600051 FAN OSCLILLATION AREA DI AZIONE VENTILATORE EC600051 AREA COVERAGE AREA DI COPERTURA 28-35 m2 max. 700 cm. Non oscillating mode 45 Oscillation EC300013 + EC300077 45 Oscillation max. 500 cm. 14 mt. 3

max. 400 cm. Schema esemplificativo di installazione ALIMENTAZIONE IDRICA IF600050 cooling fans with polyamide pipeline Ventilatori raffrescanti IF600050 con linea polyamide 1) Fans should be mounted 4 meters far from each other and no more than 8 meters 2) Fans must be mounted at 240/300 cm. height from floor 1) La distanza consigliata tra i ventilatori è di 4 mt. e non deve superare gli 8 metri 2) Montare i ventilatori a parete ad una altezza compresa tra 240 e 300 cm. dal suolo EC600050 FAN WITH MISTING RING VENTILATORE EC600050 CON GHIERA PORTAUGELLI WATER TAP max. 700 cm. Ec600050 FAN AREA DI AZIONE VENTILATORE EC600050 AREA COVERAGE AREA DI COPERTURA 24-30 m2 max. 700 cm. Non oscillating mode max. 400 cm. 14 mt. 4

Schema esemplificativo di installazione EuroJet MOST COMMON PARTS FOR EUROJET COMPONENTI STANDARD PER EUROJET ALIMENTAZIONE IDRICA TUBO H.P. Clamp IF400007 10/24 0.15 Nozzle IF130159 L fitting IF300005 max. 300 250 cm. 7.70 mt. 350 cm. AREA COVERAGE AREA DI COPERTURA 40-60 m2 7.70 mt. 5

ALIMENTAZIONE IDRICA Schema esemplificativo di installazione IF600162 industrial cooling fan Ventilatore raffrescante industriale IF600162 BALL VALVE If600162 FAN WITH MISTING RING VENTILATORE EC600162 CON GHIERA PORTAUGELLI AREA COVERAGE AREA DI COPERTURA 200-250 m2 25 mt. 9 mt. 1) Fans should be mounted 25 meters far from each other 2) Fans must be mounted at 450 or more cm. height from floor 1) La distanza consigliata tra i ventilatori è di 25 mt. 2) Montare i ventilatori a parete o in sospensione ad una altezza maggiore di 450 cm. dal suolo 6

150 cm. 80 cm. Humidification polyamide pipes line Requires: TIME pump + Humidity Controller Schema esemplificativo di installazione Sistema di umidificazione in linea polyamide Necessita: pompa serie TIME + Igrostato 250 cm. HUMIDITY REGULATOR IGROSTATO 1 5 ALIMENTAZIONE IDRICA HUMIDITY PROBE SONDA IGROSTATO FOOD STORAGE / GROWING Area di stoccaggio o produzione FRUIT Frutta VEGETABLES Verdura MUSHROOMS Funghi CHEESE Formaggio WINE Vino FLOWERS Fiori PLANTS Piante TOBACCO Tabacco MOST COMMON PARTS FOR HUMIDITY SYSTEM COMPONENTI STANDARD PER SISTEMA UMIDIFICAZIONE 500 cm. Clamp IF400007 3/8 poly line union EC300002 10/24 0.2 Nozzle IF130209 Clamp IF400007 7

80 cm. 80 cm. 80 cm. 1 with multiple humidification polyamide pipelines Requires: VAR pump + Humidity Controllers Schema esemplificativo di installazione Sistema di umidificazione con linee multiple Necessita: pompa serie VAR + Igrostati SOLENOID VALVES DRAIN KIT ELETTROVALVOLE SCARICO CELLA / ROOM 1 250 cm. 5 HUMIDITY PROBE SONDA IGROSTATO HUMIDITY REGULATOR IGROSTATO ALIMENTAZIONE IDRICA SOLENOID VALVES DRAIN KIT ELETTROVALVOLE SCARICO CELLA / ROOM 2 250 cm. HUMIDITY PROBE SONDA IGROSTATO HUMIDITY REGULATOR IGROSTATO SOLENOID VALVES DRAIN KIT ELETTROVALVOLE SCARICO CELLA / ROOM 3 250 cm. HUMIDITY PROBE SONDA IGROSTATO HUMIDITY REGULATOR IGROSTATO FOOD STORAGE / GROWING Area di stoccaggio o produzione FRUIT Frutta VEGETABLES Verdura MUSHROOMS Funghi CHEESE Formaggio WINE Vino FLOWERS Fiori PLANTS Piante TOBACCO Tabacco 8

Totem and Arch with Oasis pump Schema esemplificativo installazione Totem e Arco con pompa Oasis ALIMENTAZIONE IDRICA TOTEM CHECK VALVE NON RITORNO BALL VALVE MOST COMMON PARTS FOR TOTEM/ARCH SYSTEM COMPONENTI STANDARD PER SISTEMA TOTEM/ARCO 1/8 0.3 Nozzle IF730304 ARCH ARCO Check Valve IF309020 CHECK VALVE NON RITORNO BALL VALVE 9

200 cm. Indoor Cooling with Copper or Polyamide pipes line Schema esemplificativo installazione Raffrescamento ambiente interno con linea ugelli ALIMENTAZIONE IDRICA EXTRACTING FAN VENTOLA ESTRAZIONE VALVE 30/40 250 cm. cm. OPEN WINDOWS FINESTRE APERTE EXTRACTING FAN VENTOLA ESTRAZIONE EXTRACTING FAN VENTOLA ESTRAZIONE EXTRACTING FAN VENTOLA ESTRAZIONE LINE END FINE LINEA LINE END FINE LINEA 10

Outdoor Cooling Cooling Fans Humidification Greenhouses Livestock Odor and Dust suppression Special effects ITAL EUROPE REGGIO EMILIA - ROME - ITALY info@italfog.com ITAL MENA DUBAI - JEDDAH - TUNIS mena@italfog.com