CELEST A. High efficiency air/water cooled chillers 8 38

Similar documents
CELEST. Air/water cooled chillers and heat pumps 6 41

CRIMSON & CRIMSON MAX

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Blue Box Epsilon Echos +

Water chillers water/water type SIGMA Technical information manual

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Galletti Water chillers and heat pumps catalogue

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

HYDRONIC RESIDENTIAL

LZA High efficiency air to water heat pumps with HP compressor

LZT High efficiency air to water heat pumps with E.V.I. compressors

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

WZH Ground source heat pumps

ZETA kw. Installation, operating, and maintenance manual. Manual B02 Issue Replaces 04.02

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Motor-driven condensing units MTE MTE R-410A

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

GEYSER kw. General information. Unique selling points

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

kw COOLING kw HEATING

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Development of an advanced control system for chillers

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Air Cooled Chillers & Heat Pumps WinPACK HE-A

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Air-to-water scroll chillers

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Ultimate energy saving technology

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

technical catalogue omicron kw Multifunctional Air/Water/Water

44,9 202,0 kw. technicalcatalogue

High temperature air-to-water heat pumps

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

GLIDER EVO GLIDER EVO. rcgroupairconditioning

LZT High efficiency air to water heat pumps with E.V.I. compressors

PYXIS U PYXIS U. rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

Conditioning your ambient, maximising your comfort.

ULTIMATE ENERGY SAVING TECHNOLOGY

pyxis u pyxis ua NEW rcgroupairconditioning

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

PRODUCT GUIDE

i-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

Aquaflair TRAC-TRAF-TRAH

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

LVN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

Transcription:

High efficiency air/water cooled chillers 8 38 General An extensive and complete range composed of twelve models, conceived and developed for providing the maximum comfort and the highest levels of environmental well-being. Configurations A: Energy efficiency class A HP: Reversible heat pump LE: For connection to remote evaporator DK: With fan, possibility for duct connection LN: Low sound level Optional pump-/tank module Quick facts Eco-friendly cooling Long-lasting reliability Extremely quiet operation Compact dimensions High performance at any temperature Efficient energy performance Fast and quick installation

INDEX Technical reatures 3 Standard equipment 3 Accessories 4 CELEST A - Technical data 6 CELEST A - Cooling capacity 9 Noise Levels - CELEST A 13 Dimensional drawing 14 Installations recommendations 23 2

TECHNICAL FEATURES CELEST A High efficiency air/water cooled chillers with axial fans. STRUCTURE Made in galvanised steel sheet and painted at 180 C with RAL 7035 polyester powder, which provides high weather resistance. The panels can easily be removed to provide full access to internal parts. COMPRESSOR Hermetic scroll type compressor, complete with thermal protection inside the electric engine, crankcase heater and rubber anti-vibration mounts. SOURCE SIDE HEAT EXCHANGER Composed of an aluminium-finned copper-tube multi-row coil with increased heat transfer surface and fin spacing sized to maximize the heat exchange and reduce the noise impact. The finned coil pack is protected by a metal mesh. FANS Helical fans coupled directly to the 6-pole electric motor with external rotor, IP 54 degree of protection. Each fan is fitted in shaped nozzles and equipped with protection grille in compliance with UNI EN 294. USER SIDE HEAT EXCHANGER Plate type heat exchanger in AISI 316 stainless steel covered with closed-cell foam which reduces the thermal loss and prevent condensation. The heat exchanger is fitted with a temperature probe for antifreeze protection, a probe for detecting the ingoing and outgoing water temperature and a vane operated flow switch supplied as standard. COOLING CIRCUIT Comprises: feeding plug on fluid and suction line, fluid sight glass, dehydrating filter, thermostatic expansion valve with pressure external equilizer, pressure transducer, high and low pressure switches and safety valve (except for sizes 6, 8, 10). ELECTRICAL PANEL With main disconnect switch, breakers for auxiliary and main power circuit protection, remote disconnect switch for compressors. The unit is controlled via microprocessor with display of the main functions. The electrical panel consists of: Automatic disconnect switch for the main and auxiliary power circuits (sizes 6.8 and 10); Main disconnect switch and fuses for main and auxiliary power circuit protection (sizes from 14 to 37) Compressor remote switch Fan speed regulator for condensate control Pump relay and remote disconnect switch (sizes from 14 to 37, versions ST1P or ST1PS) General alarm dry contacts Microprocessor to control the following functions: --Control of ingoing water temperature --Anti-freeze protection --Compressor timer --Control of high pressure pre-alarm (to avoid in many cases the unit blockage) --Alarm signals --Alarm reset --Self-adjusting control to provide proper operation when the plant water content is low --External ON-OFF digital input Display of: --Outgoing water temperature --Condensation temperature --Set temperature and differential pressure --Alarm description --Hour counter for compressor and pump operation Electric power supply 230V/1~/50Hz for sizes 6 and 8, 400V/3N~/50Hz for sizes from 10 to 37. CONTROL AND SAFETY DEVICES User water temperature control probe (on evaporator inlet) Anti-freeze probe which activates the anti-freeze alarm (with limited trip automatic reset) Manual reset high pressure controller Low pressure controller (with limited trip automatic reset) Vane operated mechanical flow switch (supplied as standard) Condensing pressure controlled by operation speed regulator with low external temperatures High pressure safety valve (except for sizes 6, 8, 10) Compressor overtemperature protection TESTING The units are factory-tested and supplied complete with oil and refrigerant. HYDRAULIC SYSTEM OPTIONS CELEST A /ST 1P unit with pump The unit consists of one circulator (sizes from 6 to 18) or a circulation pump (sizes from 21 to 37), expansion vessel, hydraulic circuit water discharge valve, safety valve calibrated at 6 bar, value corresponding to the maximum allowed operation pressure. CELEST A /ST 1PS unit with pump and tank In addition to components of the /ST 1P version, the unit has an insulated storage tank. STANDARD EQUIPMENT Dispositivo di sezionamento generale Fusibili compressori Contatore 3

Rete protezione batteria Controllo a microprocessore Controllo condensazione con regolatore di giri ventilatori Logica di regolazione auto-adattabile Flussostato (fornito a corredo) Certificazione Direttiva 97/23 CEE (PED) On/Off remoto da ingresso digitale di serie Monitore di fase ACCESSORIES REFRIGERANT CIRCUIT ACCESSORIES Fluid line valve Electronic thermostatic valve HYDRAULIC CIRCUIT ACCESSORIES Filling unit with pressure gauge Anti-freeze heater Standard version: Electric heater in the heat exchanger ST1P version: Electric heater in the heat exchanger+ heating cable on the pipes ST1PS version: Electric heater in the heat exchanger+ heating cable on the pipes+ heater at tank input ELECTRICAL ACCESSORIES Power supply 230/1/50 ( for sizes 10 and 14) Power supply 400/3/50+N (for sizes 6, 8) Phase monitor Serial interface RS485 Remote user terminal (in addition to the one installed on the machine) User interface Set point offset depending on the external air temperature Electronic soft-starter MISCELLANEOUS ACCESSORIES Rubber antivibration mounts Packaging in wooden crates BRINE KIT ACCESSORY It is applied if the evaporator output temperature is included within +3 C and -8 C. It consists in a higher thermal insulation of the exchanger and piping, a specific calibration of the low pressure switches and of the anti-freeze alarm, and dimensioning check of the mechanical thermostatic valve. If it is not included in the set-up, the Check condensation accessory must be added. ELECTRONIC THERMOSTATIC VALVE L utilizzo di questo accessorio è particolarmente indicato sulle unità che si trovano ad operare in condizioni di carico termico molto variabile o di modalità di funzionamento variabili, come nel caso della gestione congiunta di condizionamento e produzione di acqua ad alta temperatura. L impiego della valvola termostatica elettronica infatti permette di: massimizzare lo scambio termico all evaporatore minimizzare i tempi di risposta alle variazioni del carico e di condizioni operative ottimizzare la regolazione del surriscaldamento garantire la massima efficienza energetica PRESSOSTATIC CONDENSATION/EVAPORA- TION CONTROL WITH FAN REV. REGULATOR The unit microprocessor control verifies all its functioning parameters and carries out a continuous fan speed adjustment by means of a fan rev. regulator, in order to optimise the operative conditions and the unit efficiency. Moreover, this adjustment has a sound level reduction effect on the unit. In fact, the typical conditions where the control will modulate the fan speed are at night and mid-seasons. This means that every time there is a chance, the machine will reduce the fan speed and also its sound level to its minimum. SELF-ADAPTABLE REGULATION LOGIC This function allows the unit control to dynamically vary the outlet water set point according to the stop and functional cycles of the machine: in practice, by increasing and reducing the water outlet temperature, the control avoids that compressor start-ups are too close in time, decreasing the number of peaks and protecting the unit components REMOTE ON/OFF FROM DIGITAL INPUT This function is standard on all units and consists in a remote contact that allows to switch on and off the machine through a signal that can be taken inside the building by a BMS (Building Management System) system. FILLING SYSTEM WITH MANOMETER This accessory allows the automatic load of the hydraulic system, the adjustment of the correct working pressure, which can always be verified by using the manometer, and enables the continuous maintenance of such pressure, reintegrating the missing water if necessary. RS-485 INTERFACE The growing diffusion of both domotic and BMS (Building Management System) systems led to the integration of all the system components under an only supervision. To respond to this request, the unit can be equipped with a serial board that allows the correct machine integration in the building-system, by using MODBUS or CAREL communication protocols.. REMOTE CONTROL USER TERMINAL Intended for a professional user, it consists in a faithful reproduction of the control panel, from where the unit can be completely set and all its parameters visualised on the display. Insertion of passwords, which enable different access levels, are required to access the parameters. The type of terminal depends on the control installed on the unit SOFT-STARTER Blue Box units adopt all the required functioning set-ups and logics to minimise peak currents. The Soft-Starter accessory allows a further 40% reduction of normal current peaks, through an electronic control of the electric motor start-up. 4

COMPENSATION OF THE SET-POINT according to the external air temperature The unit microprocessor control can compensate the set point in a dynamic way, on variation of the external air temperature. The compensation can be positive or negative: with positive compensation, on increase of the air temperature the functioning set also increases. With negative compensation on increase of the air temperature the set decreases. Compensation can be made either on the summer set point or on the winter set point (heat pumps). By default, both summer and winter negative compensation is set, but this configuration can be modified from the microprocessor keyboard. Unless otherwise specified, default values are indicated in the graphics below. SUMMER COMPENSATION - POSITIVE WINTER COMPENSATION - NEGATIVE SET POINT 1 5 C 40 / 45 C 0 C T1 Air temperature SET POINT 2 15 C T2 35 / 40 C SET POINT 2 17 / 12 C SET POINT 1 12 / 7 C 5 C 25 C T1 35 C T2 Air temperature SUMMER COMPENSATION - NEGATIVE SET POINT 2 17 / 12 C 5 C SET POINT 1 12 / 7 C 25 C T1 35 C T2 Air temperature WINTER COMPENSATION - POSITIVE SET POINT 1 40 / 45 C SET POINT 2 30 / 40 C 5 C 0 C T1 Air temperature 15 C T2 5

CELEST A - Technical data UNIT SIZE Cooling (Gross values) Nominal cooling capacity Total power input for cooling EER Efficiency class Cooling (EN 14511 values) Nominal cooling capacity EER Efficiency class Cooling (Gross values) Nominal cooling capacity Total power input for cooling EER ESEER Efficiency class Cooling (EN 14511 values) Nominal cooling capacity EER ESEER Efficiency class Compressors Quantity/Refrigerant circuits Capacity steps Fans Quantity Air flow Evaporator Water flow rate Pressure drop Hydraulic module Available pump pressure Storage tank capacity Sound level Sound power value Sound pressure value 6 8 10 14 16 18 21 25 28 31 37 (1) kw 8,5 10,3 13,4 18,0 20,2 23,3 26,5 28,8 33,7 40,2 44,8 (1), (2) kw 2,2 2,6 3,4 4,4 4,8 5,6 6,4 7,0 8,0 9,7 10,5 (1) 3,86 3,90 3,91 4,07 4,21 4,13 4,12 4,11 4,23 4,15 4,25 A A A A A A A A A A A (1),(8) kw 8,4 10,3 13,4 17,8 20,0 23,1 26,3 28,6 33,4 39,9 44,5 (1),(8) 3,81 3,85 3,85 3,87 4,03 3,96 3,94 3,95 4,06 3,99 4,09 A A A A A A A A A A A (3) kw 6,2 7,5 10,0 13,4 14,9 17,3 19,4 21,2 25,1 29,8 33,4 (3), (2) kw 2,1 2,5 3,2 4,1 4,7 5,2 5,9 6,5 7,3 9,0 9,8 (3) 2,92 2,95 3,15 3,24 3,20 3,33 3,28 3,25 3,46 3,30 3,41 3,48 3,61 3,74 3,83 3,63 3,88 3,81 3,80 3,98 3,83 3,95 B B A A A A A A A A A (3),(8) kw 6,2 7,5 10,0 13,3 14,8 17,2 19,3 21,1 25,0 29,6 33,2 (3),(8) 2,90 2,93 3,13 3,14 3,12 3,24 3,19 3,17 3,37 3,22 3,33 (8) 3,39 3,52 3,64 3,62 3,45 3,68 3,61 3,61 3,78 3,63 3,75 B B A A A A A A A A A n / n 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 % 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-100 n 1 1 1 2 2 2 2 2 2 2 2 m3/h 3.900 3.900 3.600 7.800 7.800 7.200 14.000 14.000 13.000 18.000 17.000 (1) l/h 1.455 1.771 2.304 3.095 3.474 4.007 4.557 4.953 5.795 6.913 7.704 (1) kpa 5 5 7 51 40 45 50 44 48 50 50 kpa 60 58 53 54 55 52 100 96 62 130 110 l 40 40 40 70 70 70 110 110 110 140 140 (4) db(a) 63 65 66 68 70 70 72 73 73 74 75 (5) db(a) 32 34 35 37 39 39 41 42 42 42 43 (1) External air temperature 35 C; ingoing/outgoing water temperature 23/18 C. (2) The total capacity is represented by the sum of the power absorbed by compressors and that absorbed by fans (3) External air temperature 35 C; ingoing/outgoing water temperature 12/7 C. (3) Noise power level measured according to ISO 3744 (5) Sound pressure levels measured at 10 metres from the unit in free field and directivity factor Q=2 6 (8) Valori conformi allo standard EN 14511-3:2011 This data sheet shows the data of the basic and standard series; for further details refer to the specific documentation. The values and pictures reported in the document are purely indicative and can be modified by the Manufacturer without any prior notice. For further information refer to the specific documentation. The reproduction, even partial, is strictly prohibited.

CELEST A - Technical data H D R D D F L L L L R STANDARD VERSION E/ST1P 6 8 10 14 16 18 21 25 28 31 37 L Length mm 925 925 1.105 1.305 D Depth mm 375 375 505 505 H Height H mm 700 1.350 1.385 1.585 W Operating weight (1) kg 88 93 102 135 151 166 212 233 233 367 367 ST 1PS VERSION 6 8 10 14 D 16 18 21 25 28 31 37 L Length mm 925 925 1.105 1.305 D Depth mm 375 375 505 505 H Height L L L L R mm 1.000 1.750 1.850 2.050 W Operating weight (1) kg 172 177 186 269 285 300 410 431 589 598 598 Clearance areas 6 8 10 14 16 18 21 25 28 31 37 LL Left side (2) mm 300 300 300 300 LR Right side (2) mm 600 600 600 600 DF Front (2) mm 900 900 900 900 DR Back (2) mm 300 300 300 300 D R D F (1)The reported weight is only indicative and may be different depending on unit outfit (2)The clearance areas are reported considering as front side the side with the fans 7

COOLING +20 +15 User outgoing water temperature [ C] +12 +10 +5 0-5 -10-15 -10-5 0 +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +46 External air temperature [ C] The heat exchanger on the user side must have a thermal rise between 4 C and 7 C : the unit can operate within these values only with glycol/ water mixture on the evaporator side BASIC VERSION Maximum absorbed power Maximum absorbed current Maximum input current Additional electric heater (optional) ST1P or ST1PS VERSION Maximum absorbed power Maximum absorbed current Maximum input current Additional electric heater (optional) Standard power supply Optional power supply POWER SUPPLY 6 8 10 14 16 18 21 25 28 31 37 (1) [kw] 3,1 3,9 4,5 6,3 6,4 7,6 8,9 9,6 10,7 12,9 14,6 (2) [A] 16,7 19,7 8,7 11,5 13,3 16,5 18,4 19,4 24,4 27,0 30,0 (3) [A] 62 83 49 65 65 75 104 98 114 123 123 (37) (50) (29) (39) (39) (45) (63) (59) (69) (74) (74) (4) [kw] 3,0 3,0 3,0 6,0 6,0 6,0 6,0 6,0 6,0 9,0 9,0 6 8 10 14 16 18 21 25 28 31 37 (1) [kw] 3,3 4,1 4,7 6,5 6,5 7,7 9,3 10,1 11,2 13,8 15,5 (2) [A] 17,7 20,7 9,7 12,6 14,4 17,6 21,2 22,2 27,2 29,6 32,6 (3) [A] 63 84 50 67 67 77 107 101 117 126 126 (38) (50) (30) (40) (40) (46) (64) (61) (70) (75) (75) (4) [kw] 3,0 3,0 3,0 6,0 6,0 6,0 6,0 6,0 6,0 9,0 9,0 V/ph/Hz (4) V/ph/Hz 400/3N~/50 6 8 10 14 16 18 21 25 28 31 37 230/1~/50 400/3N~/50 230/1~/50 All reported data refer to unit with standard power supply (1) Electrical power that must be supplied by the mains to power the unit (2) Tripping current of unit internal breakers. This value is never exceeded and must be used to size the line and its protections (refer to the electric diagram supplied with the unit). (3) Maximum input current calculated considering the compressor start and the maximum current absorbed by all other devices. The value between brackets refers to the unit equipped with soft-starter (optional). (4) To be requested when ordering The values and pictures reported in the document are purely indicative and can be modified by the Manufacturer without any prior notice. For further information refer to the specific documentation. The reproduction, even partial, is strictly prohibited. 8

CELEST A - cooling capacity Model 6 8 10 To EXTERNAL AIR TEMPERATURE [ C] [ C] 25 30 35 40 43 Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 6,5 1,5 6,2 1,7 5,8 1,9 5,4 2,2 5,1 2,4 6 6,7 1,5 6,4 1,7 6,0 1,9 5,6 2,2 5,3 2,4 7 6,9 1,5 6,6 1,7 6,2 1,9 5,7 2,2 5,5 2,4 8 7,1 1,5 6,8 1,7 6,4 1,9 5,9 2,2 5,6 2,4 9 7,4 1,5 7,0 1,7 6,5 1,9 6,1 2,2 5,8 2,4 10 7,6 1,5 7,2 1,7 6,7 1,9 6,3 2,2 6,0 2,4 11 7,8 1,5 7,4 1,7 6,9 1,9 6,5 2,2 6,2 2,4 12 8,0 1,5 7,6 1,7 7,1 2,0 6,7 2,2 6,4 2,4 13 8,3 1,5 7,8 1,7 7,4 2,0 6,9 2,2 6,6 2,4 14 8,5 1,5 8,0 1,7 7,6 2,0 7,1 2,2 6,8 2,4 15 8,7 1,5 8,3 1,7 7,8 2,0 7,3 2,2 6,9 2,4 16 9,0 1,6 8,5 1,8 8,0 2,0 7,5 2,2 7,1 2,4 17 9,2 1,6 8,7 1,8 8,2 2,0 7,7 2,2 7,4 2,4 18 9,5 1,6 9,0 1,8 8,5 2,0 7,9 2,2 7,6 2,4 5 8,0 1,8 7,5 2,0 7,1 2,3 6,6 2,7 6,3 2,9 6 8,2 1,8 7,8 2,0 7,3 2,3 6,8 2,7 6,5 2,9 7 8,5 1,8 8,0 2,1 7,5 2,3 7,0 2,7 6,7 2,9 8 8,7 1,8 8,3 2,1 7,8 2,4 7,2 2,7 6,9 2,9 9 9,0 1,8 8,5 2,1 8,0 2,4 7,5 2,7 7,1 2,9 10 9,3 1,8 8,8 2,1 8,2 2,4 7,7 2,7 7,3 2,9 11 9,5 1,8 9,0 2,1 8,5 2,4 7,9 2,7 7,5 2,9 12 9,8 1,8 9,3 2,1 8,7 2,4 8,1 2,7 7,8 2,9 13 10,1 1,8 9,5 2,1 9,0 2,4 8,4 2,7 8,0 2,9 14 10,4 1,9 9,8 2,1 9,2 2,4 8,6 2,7 8,2 3,0 15 10,6 1,9 10,1 2,1 9,5 2,4 8,9 2,7 8,5 3,0 16 10,9 1,9 10,4 2,1 9,8 2,4 9,1 2,8 8,7 3,0 17 11,2 1,9 10,7 2,1 10,0 2,4 9,4 2,8 8,9 3,0 18 11,6 1,9 10,9 2,2 10,3 2,4 9,6 2,8 9,2 3,0 5 10,6 2,3 10,0 2,6 9,4 2,9 8,7 3,3 8,2 3,6 6 10,9 2,4 10,3 2,6 9,7 3,0 9,0 3,3 8,5 3,6 7 11,3 2,4 10,6 2,7 10,0 3,0 9,2 3,3 8,8 3,6 8 11,6 2,4 10,9 2,7 10,2 3,0 9,5 3,4 9,0 3,6 9 11,9 2,4 11,3 2,7 10,5 3,0 9,8 3,4 9,3 3,6 10 12,3 2,4 11,6 2,7 10,8 3,0 10,1 3,4 9,6 3,7 11 12,6 2,4 11,9 2,7 11,1 3,1 10,3 3,4 9,8 3,7 12 13,0 2,5 12,2 2,8 11,5 3,1 10,6 3,5 10,1 3,7 13 13,3 2,5 12,6 2,8 11,8 3,1 10,9 3,5 10,4 3,7 14 13,7 2,5 12,9 2,8 12,1 3,1 11,2 3,5 10,7 3,8 15 14,0 2,5 13,2 2,8 12,4 3,2 11,5 3,5 10,9 3,8 16 14,4 2,5 13,6 2,8 12,7 3,2 11,8 3,6 11,2 3,8 17 14,8 2,6 14,0 2,9 13,1 3,2 12,1 3,6 11,5 3,9 18 15,2 2,6 14,3 2,9 13,4 3,2 12,5 3,6 11,8 3,9 Pf:cooling capacity [kw] Pe:electrical power absorbed by the compressors [kw] To:evaporator outgoing water temperature [ C] 9

CELEST A - cooling capacity Model 14 16 18 To EXTERNAL AIR TEMPERATURE [ C] [ C] 25 30 35 40 43 Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 14,1 2,9 13,4 3,3 12,6 3,7 11,8 4,2 11,2 4,6 6 14,5 2,9 13,8 3,3 13,0 3,7 12,1 4,2 11,6 4,6 7 15,0 2,9 14,2 3,3 13,4 3,7 12,5 4,3 11,9 4,6 8 15,4 3,0 14,6 3,3 13,8 3,8 12,9 4,3 12,3 4,6 9 15,8 3,0 15,0 3,4 14,2 3,8 13,2 4,3 12,6 4,6 10 16,3 3,0 15,5 3,4 14,6 3,8 13,6 4,3 13,0 4,7 11 16,7 3,0 15,9 3,4 15,0 3,8 14,0 4,3 13,4 4,7 12 17,2 3,0 16,3 3,4 15,4 3,8 14,4 4,4 13,7 4,7 13 17,6 3,1 16,7 3,4 15,8 3,9 14,8 4,4 14,1 4,7 14 18,1 3,1 17,2 3,5 16,2 3,9 15,2 4,4 14,5 4,7 15 18,6 3,1 17,6 3,5 16,7 3,9 15,6 4,4 14,9 4,8 16 19,0 3,2 18,1 3,5 17,1 4,0 16,0 4,5 15,3 4,8 17 19,5 3,2 18,6 3,6 17,6 4,0 16,4 4,5 15,7 4,8 18 20,0 3,2 19,0 3,6 18,0 4,0 16,9 4,5 16,1 4,8 5 15,6 3,4 14,7 3,8 13,8 4,3 12,8 4,7 12,2 5,0 6 16,0 3,5 15,2 3,8 14,3 4,3 13,3 4,7 12,6 5,0 7 16,5 3,5 15,7 3,9 14,7 4,3 13,7 4,7 13,0 5,0 8 17,0 3,5 16,2 3,9 15,2 4,3 14,1 4,8 13,5 5,1 9 17,5 3,5 16,6 3,9 15,7 4,3 14,6 4,8 13,9 5,1 10 18,1 3,5 17,1 3,9 16,1 4,3 15,0 4,8 14,3 5,1 11 18,6 3,5 17,6 3,9 16,6 4,3 15,5 4,8 14,8 5,1 12 19,1 3,5 18,2 3,9 17,1 4,3 16,0 4,8 15,2 5,1 13 19,7 3,5 18,7 3,9 17,6 4,3 16,4 4,8 15,7 5,1 14 20,2 3,6 19,2 3,9 18,1 4,4 16,9 4,8 16,2 5,1 15 20,8 3,6 19,8 3,9 18,6 4,4 17,4 4,8 16,7 5,1 16 21,4 3,6 20,3 4,0 19,2 4,4 17,9 4,9 17,2 5,2 17 22,0 3,6 20,9 4,0 19,7 4,4 18,5 4,9 17,7 5,2 18 22,6 3,6 21,5 4,0 20,3 4,4 19,0 4,9 18,2 5,2 5 18,3 3,8 17,3 4,2 16,3 4,7 15,2 5,3 14,5 5,7 6 18,8 3,8 17,8 4,3 16,8 4,8 15,6 5,3 14,9 5,7 7 19,4 3,9 18,4 4,3 17,3 4,8 16,1 5,4 15,3 5,8 8 20,0 3,9 18,9 4,3 17,8 4,8 16,6 5,4 15,8 5,8 9 20,5 3,9 19,4 4,4 18,3 4,9 17,0 5,5 16,3 5,8 10 21,1 4,0 20,0 4,4 18,8 4,9 17,5 5,5 16,7 5,9 11 21,7 4,0 20,5 4,4 19,3 5,0 18,0 5,5 17,2 5,9 12 22,3 4,0 21,1 4,5 19,9 5,0 18,5 5,6 17,7 6,0 13 22,9 4,1 21,7 4,5 20,4 5,0 19,0 5,6 18,2 6,0 14 23,5 4,1 22,3 4,6 21,0 5,1 19,6 5,7 18,7 6,1 15 24,1 4,1 22,9 4,6 21,5 5,1 20,1 5,7 19,2 6,1 16 24,8 4,2 23,5 4,6 22,1 5,2 20,6 5,8 19,7 6,1 17 25,4 4,2 24,1 4,7 22,7 5,2 21,2 5,8 20,2 6,2 18 26,1 4,3 24,7 4,7 23,3 5,2 21,7 5,8 20,8 6,2 Pf:cooling capacity [kw] Pe:electrical power absorbed by the compressors [kw] To:evaporator outgoing water temperature [ C] 10

CELEST A - cooling capacity Model 21 25 28 To EXTERNAL AIR TEMPERATURE [ C] [ C] 25 30 35 40 43 Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 20,4 4,2 19,4 4,7 18,3 5,2 17,1 5,9 16,4 6,3 6 21,1 4,2 20,0 4,7 18,9 5,3 17,7 5,9 16,9 6,3 7 21,7 4,3 20,6 4,8 19,4 5,3 18,2 6,0 17,4 6,4 8 22,3 4,3 21,2 4,8 20,0 5,4 18,8 6,0 18,0 6,4 9 23,0 4,3 21,8 4,8 20,6 5,4 19,3 6,0 18,5 6,5 10 23,6 4,4 22,5 4,9 21,2 5,4 19,9 6,1 19,1 6,5 11 24,3 4,4 23,1 4,9 21,9 5,5 20,5 6,1 19,6 6,5 12 25,0 4,5 23,8 5,0 22,5 5,5 21,1 6,2 20,2 6,6 13 25,7 4,5 24,5 5,0 23,1 5,6 21,7 6,2 20,8 6,6 14 26,4 4,6 25,1 5,1 23,8 5,6 22,3 6,3 21,4 6,7 15 27,1 4,6 25,8 5,1 24,5 5,7 23,0 6,3 22,0 6,7 16 27,9 4,7 26,6 5,2 25,1 5,7 23,6 6,4 22,7 6,8 17 28,6 4,7 27,3 5,2 25,8 5,8 24,3 6,4 23,3 6,8 18 29,4 4,8 28,0 5,3 26,5 5,8 25,0 6,5 24,0 6,9 5 22,5 4,7 21,3 5,2 20,0 5,9 18,5 6,6 17,6 7,0 6 23,2 4,7 21,9 5,3 20,6 5,9 19,1 6,6 18,2 7,1 7 23,9 4,8 22,6 5,3 21,2 5,9 19,7 6,6 18,8 7,1 8 24,6 4,8 23,3 5,3 21,9 6,0 20,3 6,7 19,4 7,2 9 25,3 4,8 24,0 5,4 22,5 6,0 21,0 6,7 20,0 7,2 10 26,0 4,9 24,6 5,4 23,2 6,0 21,6 6,8 20,6 7,2 11 26,7 4,9 25,3 5,5 23,8 6,1 22,2 6,8 21,2 7,3 12 27,4 4,9 26,0 5,5 24,5 6,1 22,9 6,8 21,8 7,3 13 28,2 5,0 26,8 5,5 25,2 6,2 23,5 6,9 22,4 7,3 14 28,9 5,0 27,5 5,6 25,9 6,2 24,2 6,9 23,1 7,4 15 29,7 5,1 28,2 5,6 26,6 6,3 24,8 7,0 23,7 7,4 16 30,5 5,1 29,0 5,7 27,3 6,3 25,5 7,0 24,4 7,5 17 31,3 5,2 29,8 5,7 28,1 6,4 26,2 7,1 25,0 7,5 18 32,1 5,2 30,5 5,8 28,8 6,4 26,9 7,1 25,7 7,6 5 26,3 5,3 25,0 5,9 23,6 6,6 22,1 7,4 21,1 7,9 6 27,1 5,4 25,8 6,0 24,3 6,6 22,8 7,4 21,8 7,9 7 27,9 5,4 26,5 6,0 25,1 6,7 23,5 7,4 22,5 8,0 8 28,7 5,5 27,3 6,0 25,8 6,7 24,2 7,5 23,1 8,0 9 29,5 5,5 28,1 6,1 26,5 6,8 24,9 7,5 23,8 8,1 10 30,4 5,6 28,9 6,1 27,3 6,8 25,6 7,6 24,5 8,1 11 31,2 5,6 29,7 6,2 28,0 6,9 26,3 7,6 25,2 8,2 12 32,1 5,7 30,5 6,3 28,8 6,9 27,0 7,7 25,9 8,2 13 32,9 5,7 31,3 6,3 29,6 7,0 27,8 7,8 26,6 8,3 14 33,8 5,8 32,1 6,4 30,4 7,1 28,5 7,8 27,4 8,4 15 34,7 5,9 33,0 6,5 31,2 7,1 29,3 7,9 28,1 8,4 16 35,6 5,9 33,8 6,5 32,0 7,2 30,1 8,0 28,8 8,5 17 36,5 6,0 34,7 6,6 32,8 7,3 30,9 8,1 29,6 8,6 18 37,5 6,1 35,6 6,7 33,7 7,4 31,6 8,1 30,4 8,7 Pf:cooling capacity [kw] Pe:electrical power absorbed by the compressors [kw] To:evaporator outgoing water temperature [ C] 11

CELEST A - cooling capacity Model 31 37 To EXTERNAL AIR TEMPERATURE [ C] [ C] 25 30 35 40 43 Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 31,6 6,3 29,9 7,0 28,1 7,8 26,0 8,8 24,8 9,4 6 32,6 6,3 30,9 7,0 29,0 7,9 26,9 8,8 25,5 9,5 7 33,5 6,4 31,7 7,1 29,8 7,9 27,7 8,9 26,3 9,5 8 34,5 6,4 32,7 7,1 30,7 8,0 28,5 8,9 27,1 9,6 9 35,5 6,5 33,6 7,2 31,6 8,0 29,4 9,0 28,0 9,6 10 36,4 6,5 34,5 7,3 32,5 8,1 30,2 9,0 28,8 9,7 11 37,4 6,6 35,5 7,3 33,4 8,1 31,1 9,1 29,6 9,7 12 38,4 6,6 36,5 7,4 34,3 8,2 32,0 9,1 30,5 9,8 13 39,5 6,7 37,5 7,4 35,3 8,3 32,9 9,2 31,3 9,8 14 40,5 6,8 38,5 7,5 36,2 8,3 33,8 9,3 32,2 9,9 15 41,6 6,8 39,5 7,6 37,2 8,4 34,7 9,3 33,1 10,0 16 42,7 6,9 40,5 7,6 38,2 8,5 35,6 9,4 34,0 10,0 17 43,8 7,0 41,6 7,7 39,2 8,5 36,6 9,5 34,9 10,1 18 44,9 7,0 42,7 7,8 40,2 8,6 37,6 9,5 35,9 10,2 5 35,4 6,9 33,5 7,7 31,5 8,6 29,3 9,6 27,8 10,3 6 36,4 6,9 34,6 7,7 32,5 8,6 30,2 9,7 28,7 10,4 7 37,5 7,0 35,5 7,8 33,4 8,7 31,1 9,7 29,6 10,4 8 38,6 7,0 36,6 7,8 34,4 8,8 32,0 9,8 30,4 10,5 9 39,7 7,1 37,6 7,9 35,4 8,8 32,9 9,9 31,3 10,6 10 40,8 7,2 38,7 7,9 36,3 8,9 33,8 9,9 32,2 10,6 11 41,9 7,2 39,7 8,0 37,3 8,9 34,8 10,0 33,1 10,7 12 43,0 7,3 40,8 8,1 38,4 9,0 35,7 10,1 34,0 10,8 13 44,1 7,3 41,9 8,1 39,4 9,1 36,7 10,1 35,0 10,8 14 45,3 7,4 43,0 8,2 40,5 9,1 37,7 10,2 35,9 10,9 15 46,5 7,5 44,1 8,3 41,5 9,2 38,7 10,3 36,9 11,0 16 47,7 7,6 45,3 8,3 42,6 9,3 39,7 10,4 37,9 11,1 17 49,0 7,6 46,4 8,4 43,7 9,4 40,8 10,4 38,9 11,1 18 50,2 7,7 47,6 8,5 44,8 9,4 41,8 10,5 39,9 11,2 Pf:cooling capacity [kw] Pe:electrical power absorbed by the compressors [kw] To:evaporator outgoing water temperature [ C] 12

noise levels - CELEST A Model OCTAVE BAND [HZ] Total 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz [db(a)] Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 6 67,0 36,0 66,5 35,5 66,0 35,0 61,5 30,5 56,0 25,0 51,5 20,5 45,0 14,0 37,5 6,5 63 32 8 68,0 37,0 68,0 37 67,0 36 64,0 33 56,5 25,5 54,0 23 47,5 16,5 40,0 9 65 34 10 71,5 40,5 69,0 38 69,5 38,5 64,0 33 59,5 28,5 56,0 25 48,5 17,5 42,0 11 66 35 14 71,5 40,5 72,0 41 70,0 39 67,0 36 61,5 30,5 56,0 25 50,5 19,5 41,0 10 68 37 16 73,5 42,5 72,5 41,5 72,5 41,5 68,0 37 62,0 31 58,0 27 52,5 21,5 43,0 12 70 39 18 74,5 43,5 73,5 42,5 73,5 42,5 68,0 37 63,0 32 59,0 28 52,0 21 44,5 13,5 70 39 21 76,5 45,5 75,0 44 75,5 44,5 69,5 38,5 65,5 34,5 61,0 30 53,0 22 47,0 16 72 41 25 77,5 46,5 76,0 45 75,5 44,5 72,0 41 63,5 32,5 61,0 30 56,0 25 47,0 16 73 42 28 78,0 47,0 77,0 46 76,0 45 72,0 41 65,0 34 61,5 30,5 56,5 25,5 48,0 17 73 42 31 78,5 46,5 77,0 45 77,5 45,5 72,0 40 66,5 34,5 63,0 31 56,0 24 49,0 17 74 42 37 79,5 47,5 78,5 46,5 77,0 45 73,5 41,5 67,0 35 62,5 30,5 57,0 25 49,5 17,5 75 43 Lw:sound power levels measured in free field according to standard ISO 3744, under nominal operating conditions. Lp:sound pressure levels measured at 10 metres from the unit in free field under nominal operating conditions, according to ISO 3744. 13

DIMENSIONAL DRAWING CELEST A 6-10 SD00074A 14

DIMENSIONAL DRAWING CELEST A 6-10 /ST 1PS SD00078A 15

DIMENSIONAL DRAWING CELEST A 14-18 SD00075A 16

DIMENSIONAL DRAWING CELEST A 14-18 /ST 1PS SD00079A 17

DIMENSIONAL DRAWING CELEST A 21-28 SD00076A 18

DIMENSIONAL DRAWING CELEST A 21-28 /ST 1PS SD00080A 19

DIMENSIONAL DRAWING CELEST A 31-37 SD00077A 20

DIMENSIONAL DRAWING CELEST A 31-37 /ST 1PS SD00081A 21

22

INSTALLATIONS RECOMMENDATIONS LOCATION Strictly allow clearances as indicated in the catalogue. Please check that there isn t any obstructions on the suction of the finned coil and on the discharge of the fans Locate the unit in order to be compatible with environmental requirements (sound level, integrationinto the site, etc.). ELECTRICAL CONNECTIONS Check the wiring diagram enclosed with the unit, in which are always present all the instructions necessary to the electrical connections. Supply the unit at least 12 hours before start-up, in order to turn crankcase heaters on. Do notdisconnect electrical supply during temporary stop periods (i.e. weekends). Before opening the main switch, stop the unit by acting on the suitable running switches or, if lacking, on the remote control. Before servicing the inner components, disconnect electrical supply by opening the main switch. The electric supply line must be equipped with an automatic circuit breaker (to be provided by theinstaller. HYDRAULIC CONNECTIONS Carefully vent the system, with pump turned off, by acting on the vent valves. This procedure is fundamental: little air bubbles can freeze the evaporator causing the general failure of thesystem. Drain the system during seasonal stops (wintertime) or use proper mixtures with low freezing point. Incase of temporary stop periods an electric heater should be installed on the evaporator and hydraulic circuit. Install the hydraulic circuit including all the components indicated in the recommended hydraulic circuitdiagrams (expansion vessel, flow switch, strainer, storage tank, vent valves, shut off valves, flexibleconnections, etc.). Connect the flow switch, which is furnished on all units, not fitted. Follow the instructions enclosed with the units. START UP AND MAINTENANCE OPERA- TIONS Strictly follow what reported in use and maintenance manual. All these operations must be carried on by trained personnel only. 23

60220001102 CELEST A_19-08-2013