LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Distributed By: M&M Control Service, Inc Building Technologies

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

Complete Boiler Management in a Compact, Affordable System

STEAMPAK Series BurnerPAK BMS Burner Management Systems

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Revitalize Building Mechanical Systems (4619)

Complete burner management in a compact, affordable system

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Control Products & Systems OEM

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

WATER-TUBE POOL HEATERS

Complete burner management in a compact, affordable system

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

FINNED WATER-TUBE POOL HEATERS

Section 1 Overview. Introduction 1-1

FLEXCORE SERIES MASTERSPEC

Product Range Overview

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

DIVISION FINNED WATER-TUBE WATER HEATERS

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

Indirect gas-fired air heater

HAWK INTEGRATED BOILER CONTROL SYSTEM

HCLEARFIRE. High-efficiency, modular steam boiler HP

LOW NOx MODULATING GAS BURNERS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

AFUE 95% Heating Input 50,000 to 200,000 Btuh

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Honeywell SLATE ICM Platform

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Direct Gas-Fired Make-Up Air

KN2/4 SERIES MASTER SPECIFICATION

Triton Series High Efficiency Boiler

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Project Name: Location: Engineer: Contractor: I. GENERAL

LFL Series Burner Flame Safeguard Control

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

SECTION HEATING BOILERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

TABLE OF CONTENTS BRADFORD WHITE BOILERS

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

Indirect Gas-Fired Make-Up Air

PROFIRE BMS Controller

E340 BOILER CONTROL INSTALLATION MANUAL

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

RS /E-EV C01 SERIES

Burner Management System

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Sola Hydronic Control. An Eco-Friendly Solution.

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

STR-Series Indirect-Fired Air Turnover Units

Date: Project #: Engineer: Prepared By: Bid Date:

Basic unit with integrated air-fuel ratio control for forced draft burners

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

USER'S INFORMATION MANUAL

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Suggested Specifications Prestige Excellence 110

HIGH EFFICIENCY COMMERCIAL BOILERS

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

ClearFire - Hydronic Startup Report

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

RS /E-EV C01 SERIES

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water.

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

USER'S INFORMATION MANUAL

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

OPERATING AND MAINTENANCE MANUAL

Steam Fundamentals. (in heating & processing applications)

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Q - Series Boiler. Troubleshooting Manual

Transcription:

Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480, Fax: 620-421-0948 Web Site: www.powerflame.com E-Mail: CSD@ powerflame.com Copyright Power Flame Incorporated 2006 NVC0803 Rev. 0406

Suggested Specification for Power Flame NCV Gas Burners to 42,000 MBtu/hr) A. General Requirements 1. Furnish and install NVC14-G-30 Low NOx natural gas burners. The burner and burner installation shall meet all applicable code requirements. B. Low-NOx Burner Description 1. The burners shall be Power Flame NVC forced draft surface stabilized burners with a removable gas head for rapid switch over to fuel oil operation. Each burner shall have a maximum fired duty of 42,200 MBTU/hr. Gas pressure at the burner gas train supply connection shall be a minimum of 5.0 PSI 2. NOx emissions shall be guaranteed to be less than or equal to (9) ppm, corrected to 3% O 2, and CO emissions shall be guaranteed to be less than or equal to 50 ppm, over the full range of burner operation. 3. The burner shall operate with flue gas recirculation (FGR) with natural gas as fuel maintain combustion a 4-4 1/2 % 0 2 4. Burner turndown from maximum heat input shall be a minimum of 3.0:1. 5. Combustion head shall be of high temperature stainless steel all metal construction. Surface stabilized combustion head and be provide with refractory blanket boiler mounting plate. 6. All combustion air shall be supplied by a blower mounted integral to the burner. The blower wheel shall be of the forward curved centrifugal design and shall be directly driven by a 40 hp 3450 RPM 460 volt, 60 Hz, 3 phase motor. A dual blade damper assembly located on the inlet side of the blower wheel shall meter the combustion air flow. Design shall permit disconnecting and locking of either damper if firing rate is near minimum burner input rating. 7. The burner assembly shall be of welded steel construction and have a baked on powder coat finish. C. Approval Codes 1. Each burner shall adhere to UL NFPA-85-01 design guidelines. Each burner shall be designed and constructed as an integrated combustion system package and shall be factory fire tested. D. Ignition System 1. The burner ignition system shall utilize either natural gas as the fuel source. The gas pilot system components shall include spark ignited pilot assembly, 6000 volt ignition transformer, Dual pilot solenoid valve, pilot gas pressure regulator, pilot normally open vent valve with locking shutoff cock, pilot gas strainer, gas pressure gauge and manual gas shutoff valve. The flame proving system shall incorporate a Ultra-Violet flame detector which will monitor both the pilot and main flames. The pilot assembly shall fit within the confines of the burner/pilot assembly front mounting plate. E. Fuel/Air Control System 1. Main on-off gas supply shall be controlled by a motorized gas valve. 2. A modulating motor shall control the positioning of the air inlet dampers. Gas flow control shall be achieved by use of a proportional fuel-air ratio controller referenced to combustion air flow (Siemens or equivalent). The position of the modulating motor shall be controlled by a 135 Ohm, or 4-20 milli-

amp, or 0-10 VDC, modulating type (temperature) (pressure) controller. When the operating control is satisfied the burner shall shutoff and return to the low fire start position. The modulating motor shall provide and electrical interlock to insure a guaranteed low fire start position prior to the pilot trial for ignition sequence. F. Gas Control Trains 1. The gas train shall contain the following: a. Manual pressure lubricated shutoff cock b. Main gas pressure regulator c. Automatically operated main motorized gas valve with proof of closure interlock switch d. Automatically operated auxiliary gas valve with proof of closure interlock switch e. Normally open vent valve with locking shut off gas cock f. Manual reset Low and High gas pressure switches g. Manual pressure lubricated leakage test cock. h. Burner manifold gas pressure gauge i. (2) ¼ leak test cocks j. Main gas line strainer G. Burner Operating Controls 1. The On-Off operation of the burner shall be controlled by a (pressure) (temperature) control. System (pressure) (temperature) shall be (PSIG) (Degrees F). A safety manual reset type limit control shall be provided to shut the burner down in the event of excessive (pressure) (temperature). The position of the modulating motor and other fuel/air components shall be controlled by a 135 ohm, or 4-20 milliamp, or 0-10 volt DC (pressure)(temperature) control in addition to the On-Off operating control. H. Interlocks 1. The modulating motor shall be sequenced to allow for four (4) complete air changes of the combustion chamber and breaching, and through an integral end switch be electrically interlocked with the control burner circuit to insure the air linkage is in the low fire start position before the burner ignition sequence can begin. I. Flame Safeguard Control 1. The flame safeguard control shall include lead sulfide sensor for flame detection and provide fully automatic sequencing of pre-purge and post-purge, blower motor, interrupted ignition system, and fuel/air flow components. Burner shall purge with full open air louver at not less than 60% of high fire air flow rate for a minimum of four (4) air changes and not less than 60 seconds. Flame safeguard shall provide safety shutdown with manual reset on air flow failure. The flame safeguard control shall be Siemens LMV52 with O 2 trim The LMV52 is an electronic linkage less, microprocessor-based unit for the control and supervision of a single forced draft burner with; modulating gas, When used with matching system components, it becomes an easy to use burner management system that delivers superior control, performance and diagnostics. The LMV52 burner management system accomplishes burner control, utilizing an integrated configurable gas valve proving system, electronic fuel/air ratio control (FARC) with up to four actuators, adjusting, air, gas, and FGR, and has PID temperature / pressure control function (load controller). All of the burner management system s major components, specifically the base unit (LMV52), the display and operating unit (AZL) and the actuators (SQM4) communicate over a reliable safety bus.

Major Functions 1. The LMV52 employs two microprocessors that offer a very high level of safety and reliability for monitoring the software, the program, and the control sequences. 2. The burner control shall also employ ultra-accurate SQM4 actuators with the following features: Characteristics and settings defined by the LMV52 Shall be controlled by digital signals on a safety bus from the LMV52 Shall be driven by stepper motors Shall have a resolution of 1/10 of a degree, or 900 repeatable positions, within 90 deg of rotation Shall be equipped with two factory calibrated feedback potentiometers Shall be capable of clock-wise or counter clock-wise rotation Available in at least 3 torque ranges including, 30, 180, and 300 in/lbs (3, 20, 35 Nm) Shall not require any field adjustment Shall not require any switch wiring Shall not require any switch setting 3. All safety-related digital outputs of the LMV52 shall be permanently monitored via a contact feedback network. 4. The LMV52 shall provide burner-flame safeguard control approved for continuous duty applications, using optical solid state IR flame sensor technology including: Provisions for flame supervision using flickering infrared flame detectors (QRI) Provisions for flame supervision using ionization probes The flame detector or probe shall also house the flame amplifier, eliminating reliability issues associated with remote amplifier flame sensor wiring. Shall provide immunity to glowing refractory and 50-60 HZ lighting. The QRI IR flame sensor shall incorporate self-checking features and be specified for continuous duty. 5. Manufacturer shall be able to select from a total of seven fuel valve configurations. 6. A large number of individual parameterization choices (program times, configuration of inputs / outputs, etc.) shall allow optimum adaptations to the specific fuel train configurations. 7. A burner switch shall be provided for a standard low fire shutdown. 8. An emergency stop switch shall be provided, for an immediate shutdown, which is wired directly in the fuel valve circuit. 9. The LMV52 can be replaced, and then be re-commissioned by downloading the commissioning parameters from a backup in the AZL programming and display unit, or a PC, and shall not require reprogramming. 10. The LMV52 shall provide electronic fuel / air ratio control (FARC) with 15 points that can be added, deleted, or adjusted while running or in standby. 11. A separate display and operating unit (AZL), shall be provided with an LCD display and four buttons. Designed for front panel mounting Display shall have a 4 line by 16 character LCD display with menu driven text that is available in most standard languages including English, German, French, Spanish and Italian. Shall provide straightforward operation, and continuously show the process variable, current setpoint, load and flame signal.

Shall have a real time clock 12. The AZL shall afford a convenient readout of: Burner settings Operating state Parameters of the burner control 13. The AZL display and operating unit interfaces through three ports: Safety bus (terminal X70) Modbus connection to the LMV52 burner control base unit COM1 (terminal X70) optional connection to a PC with ACS450 software COM2 (terminal X72) optional connection to a BMS using and external e-bus interface 14. The parameter setting levels for the burner / boiler manufacturer and heating engineer, shall be password-protected to prevent unauthorized access. 15. The plant operator shall be able to adjust user level settings, such as setpoints on site, shall not demand a password. 16. When performing diagnostics, the AZL shall show at least 21 faults, and the last 9 lockouts, with the following information: Fault code number English word message (or other language) Operating state Point in time the fault occurred 17. The AZL is connected to the safety network, using a 9-pin sub-d type port, allowing you to: Select a language for the AZL Commission the LMV52 burner control Convenient programming of burner settings Process visualization Choose which additional COM port you wish to use Provides power to the AZL 18. The AZL will permit one additional port, COM1 or COM2 to be used, at the same time. 19. COM1 is a sub-d 9-pin RS-232 serial port, designed to communicate with PC commissioning software ACS450 the following operating functions are provided: Readout of settings, operating states, error types, and point in time the errors occur (from the LMV52) Graphical presentation of diagnostic data Parameterization of the LMV52 Trend/data recording Printout functions for documenting the plant settings Program update of the AZL 20. COM2 is an RJ45 socket, modbus port, on the AZL, and is capable of being used as a digital interface, for building management systems (BMS) or touch screen displays. 21. The external modbus interface must provide electrical isolation and include a power supply, and be designed to provide the following functions: Hours of operation

Operating display Current fuel type Current operating phase Input states (if available) Output states including alarms (if available) Actual value of the temperature or pressure Temperature or pressure setpoint Contents of lockout and error storages Select the type of fuel Set the date and the time of day Only non-safety-related data may be changed via the BMS 22. Burner control shall be able to accept an analog setpoint from a BMS, and settings shall be password protected to prevent unauthorized access.

23. LMV52 will control the O 2 by continuously monitoring the exhaust gas and adjusting the fuel and air controls to maintain combustion settings programmed in to the systems. Include O 2 sensor, O 2 module and flue gas collector. J. Control Panel 1. Each burner shall be complete with a remote control panel which shall house all required operating electrical components. All wiring for remote panel electrical components shall be factory pre-wired to a terminal strip mounted within the control panel. A junction box pre-wired to the burner components shall be mounted on the burner. It shall have a terminal strip which shall match a terminal strip in the remote panel. Field wiring shall be required between the burner mounted junction box and the remote control panel. 2. Appropriate electrical knockouts shall be provided on both sides of the panel to allow for necessary power and limit control wiring. The control panel shall be constructed of 14 gauge steel and shall be complete with a top switch and control section which shall be hinged to allow for full access to all panel mounted components. The control panel shall be painted in a color and finish identical to the burner being supplied. 3. The control panel shall include a step-down control circuit transformer fused on both the primary and secondary windings to power 120 V components. 4. The control panel shall have the following status indicators: Power On Green; Limit Circuit Closed Green; Main gas Blue, Flame Failure Red. High water and low water Red 5. Provide an alarm buzzer and auto reset alarm silencing switch to signal any failure status. K. Product Liability Insurance The burner manufacturer will provide an Insurance Certificate documenting his current coverage of Product Liability Insurance. L. Burner Start-up Information and Test Data On completion of the burner system start up, the installing contractor shall complete a Burner Startup Information Sheet and a Control Setting Sheet and deliver to the Specifying Engineer.