Airvec. Deaerators For Heating and Cooling Systems.

Similar documents
DirtVec. Dirt Separators For Heating and Cooling Systems.

DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS

DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DEAERATORS/ DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS

Dirt and Air Separators

DISCALDIRT deaerator-dirt separator

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

DOMESTIC OPTIMUM PERFORMANCE IN DOMESTIC HEATING AND COOLING SYSTEMS ACCESSORIES ADDITIVES ADVICE

Brawa-Mix Thermostatic mixing valves

DIRTCAL - DIRTMAG dirt separator

HERZ Differential Pressure Control Valve 4002

Halton Rex 600 Basic R6B - Active chilled beam

Halton CHB Active chilled beam with boost function for bulkhead installation

SPIROVENT JUNIOR. Microbubble Separators Dirt Separators Combination Air/Dirt Separators. The Ultimate in Distribution Efficiency

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

C 9000 Polymer Quick-Acting Safety Coupler Range

NON-SLAM DYNAMIC ARV FAF 7330

LINDOFLAMM thermal engineering.

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Commercial product range

SL S.S.N.51D

SAFETY- QUICK SHUT-OFF VALVES FOR GAS. Safety devices with automatic shut-off function ASVG DN 15, 20, 25 KVAZ DN 40, 50 FDS-VE DN 65, 200, 250, 300

STEAM TRAPS

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other

1592P01. for liquids in piping DN

NKW. Heater series HEATERS

Systems for central heating

Air and dirt in closed systems

Installation and operating instructions. DK energy storage and DK energy buffer

PRODUCT OVERVIEW THE BEST WATER QUALITY FOR OPTIMUM PERFOR- MANCE IN HVAC SYSTEMS DOMESTIC COMMERCIAL INDUSTRY SPIRO EXCEPTIONAL GUARANTEE

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

SPIROTECH BV PRESENTATION ON ENERGY EFFICIENT WET SYSTEMS

NEW. Hydronic HVAC Systems. FloCon Watchman TM. Patent Numbers: GB , GB , GB Rev: /2015

Filters & Centrifugal Separators

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Brazed heat exchanger XB

ENTROPIE boiler TT300

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Smart temperature control solutions

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Fan heater SWT Ceiling mounted fan heater with water heat

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

S304 and S305 Dust Emission Monitors. User Manual. Distributor

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)

Gasketed and brazed plate heat exchangers

ABLOY DC335 DOOR CLOSER New Rack and Pinion Door Closer ABLOY DC335 is a modern high quality door closer for all kind of door applications.

Condensate Drain Valves

HERZ Regulating valve 4002

Installation, commissioning and servicing instructions

Quick closing oil drain valve QDV

Increase your machine s runnability. Increase the web speed. Minimize web breaks. Improve work safety. Improve product quality.

FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

Snifter ATEX22 VERSION. User Manual. Distributor

Stored Water District Heating Interface Units. Heat Interface Units

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

CAP SERIES SEWAGE AND WASTE WATER PUMPS

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

Instruction Manual, Rotary Spray Heads

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Sintrol Snifter A1+ Manual. Version 1.2.2

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Steam-Atomising Desuperheater

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

F4060 RESILIENT SEATED GATE VALVES

BOILER HOUSE PRODUCTS GMS

Swegon CASA. duct coils for heating. the supply air

TS RD 7761 RD, 7761 RD

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Thermostatic valves with radiator connection systems

Condensate separators

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

TECHNICAL DATA OBSOLETE

Halton Rex for Vario R6O - Variable air volume chilled beam

Heated Gas Sampling Probe PSG Basic

CALEFFI. dirt separator series 01137/16 NA. Replaces 01137/15 NA. Product range. Technical specifications

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

VRD. Sump pump for polluted liquids

SL EX.4.51D

OPERATING AND MAINTENANCE MANUAL

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

10% Next generation heat exchangers for your district energy applications. mphe.danfoss.com

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

AUTOMATIC FILTERS. AG series HECTRON

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Transcription:

www.hogfors.com Airvec deaerator is technically advanced, easy-to-use product with simplistic design and unmatched installability. Airvec Deaerators For Heating and Cooling Systems HögforsGST

Please note before choosing your deaerator: Air / oxygen can cause several issues in heating and cooling systems. Among the most common problems are corrosion, reduced component service life, reduced heat transfer and increased noise. Key factors: Installability Ease of use Living comfort (no excessive noise) Serviceability Airvec deaerator benefits: Premium components Minimized risk of corrosion Extended life cycle of components Improved heat transfer Reduced commissioning time Fast delivery time Three-year () warranty Selecting the correct deaerator for your property requires expert guidance. AirVec operating principle and separating capability (PN0//) AirVec removes loose and dissolved air as well as particulate impurities. Inside the AirVec unit, the water's flow rate decreases rapidly, effectively separating microbubbles and particulates. Air bubbles automatically rise to the air bleeding valve at the top while particles that are heavier than water sink to the bottom of the unit. AirVec deaerators remove all microbubbles starting from μm. AirVec units equipped with dirt separation also remove particulate impurities as small as μm. Model indications Airvec 0-NSW- Pressure Category, 0=0 bar, = bar, = bar Connection, W=welded, F=flanged, G=threaded Material, S=steel, H=stainless, B=brass Model, N=normal, E=extra, O=open Pipe size (dn) Product family name

h Dimensions Airvec DN0-DN0 Airvec G /" - G" H DN H DN d ØD L h Airvec technical data G /" - G" Connection size DN (internal thread) G /" /" " d ØD L Lf H mm 0 0 h mm 0 0 d (internal thread) G ½" ½" ½" ØD mm 9 9 00 L mm 00 00 0 Lf mm - - - Flow rate l/s,0,,8 Weight kg,8,7, Airvec technical data DN0-DN0 Connection size DN (flange DIN) /mm (weld.) DN0 / Ø0. DN / Ø7. DN80 / Ø88.9 DN00 / Ø. DN / Ø9.7 DN0 / Ø8. DN00 / Ø9. DN0 / Ø7 H mm 778 778 89 9 h mm 9 9 999 999 70 H extra mm 7 7 80 80 09 09 00 h extra mm 0 0 8 8 8 9 H open mm 0 0 80 80 0 0 h open mm 09 09 9 9 8 8 9 d (internal thread) G ½" ½" ¾" ¾" " " " " ØD mm 8 8 9 9 0 08 L mm 8 8 99 9 78 Lf mm 0 9 0 0 7 8 Flow rate l/s,,, 8,,9 0,8,7, Weight weld./flange kg 9/ 9/ 7/ 7/ / /7 89/0 /8 Weight extra weld./flange kg 0/ 0/ 9/ 9/8 7/9 7/ 97/9 /9 Weight open weld./flange kg 9/ 9/ /0 / 9/8 9/8 /7 97/9 All Rights Reserved

Construction. AirVec include automatic vent valve (Flexvent PN0), which is provided with a shut-off valve part whereby the vent valve can be closed. (Flexvent Max PN/), which is provided with a set screw whereby the vent valve can be closed. The outlet of the Flexvent MAX has a millimetre connection for a drainage pipe. The lifting lugs allows for easy installation. AirVec's unique FoxisTube is designed to remove even the smallest micro bubbles and small particles of dirt without the flow resistance increases too much. Body: - PGH (EN 07-), - Exterior coating: RAL 70, coating thick. of > 0 μm. Storage range is up to DN0 (7mm) Weld end and the flanges - Weld ends: PGH (EN 07-), - Flanges: EN 09- (PN / PN). Thanks to large precipitate housing the drain interval is long 7. AirVec is provided with flush valve, (½ "- " PN0) (Naval ball valve (DN / ½ "- DN / " PN/) which the dirt is collected on the bottom may be removed when the system is in use PN0 PN- 7 7 All Rights Reserved

Equipment Standard equipment: Automatic deaerator Drain valve Additional materials and sizes available on demand. Airvec DN - DN0 For network deaeration. Can also be used for dirt separation. Sizes DN0 DN0 available in steel with welded connections / flanges. Also available in other materials. Sizes DN DN0 (G/" - G") available in brass, threaded connections. Max. operating temperature0 C. Max. operating pressure 0// PN. Airvec extra DN0 - DN0 For network deaeration dirt separation. Available in steel, welded connections / flanges. Also available in other materials. Max. operating temperature0 C. Max. operating pressure 0// PN. Airvec open DN0 - DN0 For network deaeration and dirt separation in locations with above average precipitation. Available in steel, welded connections / flanges. Also available in other materials. Max. operating temperature0 C. Max. operating pressure 0// PN. All Rights Reserved

Flow resistance dn0 dn dn80 dn00,, pressure drop kpa,,, recommended max. pressure drop level 0, 0 0,0,,0 7, 0,0,,0 7, 0,0, flow rate l/s v= m/s dn dn0 dn00 dn0,, pressure drop kpa,,, recommended max. pressure drop level 0, 0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 70,0 80,0 90,0 00,0 0,0 0,0 0,0 0,0 flow rate l/s v= m/s

Flow resistance G/ G/ G,, pressure drop kpa,,, recommended max. pressure drop level 0, 0 0 0,,,,, flow rate l/s v= m/s All values are max. values.

HögforsGST International heating system expertise HögforsGST specializes in the manufacture, sale and marketing of high-quality heating systems. The company has solid experience in heating systems both domestically and in export markets. Our professionalism is based on experience in production, serial manufacture, mass tailoring and project production as well as HVAC procurement channel and logistics expertise in Finland and abroad. Our operations are based on determining requirements for sustainable business operations on the market, customer-orientedness and reliability. We are equally uncompromising in terms of our high-quality products and services. Three-year warranty and fast delivery time: All Airvec deaerators and components come with a three-year warranty. Our products are not only premium quality; Airvec deaerators are also delivered fast! Ensuring fast delivery times is a key part of our operations. HögforsGST Manufacturer: HögforsGST Oy Tel. +8 (0)00 78 00, Fax +8 (0)7 00 www.hogfors.com P.O. Box (Pohjukansalontie ), FI-790 Leppävirta, Finland info@gst.fi