Ventilationsaggregater med krydsvarmeveksler

Similar documents
RIS H NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

RIS H EC NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

RIS H EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

RIRS V. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

CHIME-FLEX SA. Centrales compactes RECUPERATEUR A PLAQUES VERSION VERTICALE

EC L2. and humidity sensors. All units are supplied tested and ready to install.

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

RIS V. AHU with heat recovery. exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices.

RIS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. AHU med varmegenvinding AIR HANDLING UNITS

AIR HANDLING UNITS ver B

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VP 18 BY NILAN. Sanitary hot water production. Heating. Active heat recovery. Comfort heating. Ventilation < 300 m 3 /h.

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

Automatisk rumslukningsanlæg Automatic total flooding fire extinguishing systems

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Shunt groups and protection against freeze damage

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

solar Tilbehør Lyssensorer Minilux Sensor (lyssensor) type med klemmetilslutning for udendørs montage

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Heat pump & cooling unit in one

RIS H EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

CONTENT: VEX308 Decentralised ventilation VEX308

RIS. Rekuperatoriniai įrenginiai. AHU with heat recovery. Lüftungsgeräte mit wärmerückgewinnung. Вентиляционные агрегаты с рекуперацией тепла

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

RIRS H. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

Installation Instruction

We simplify construction

MEDDELELSE Elmateriel nr. 15/09

Series VENTS VUT R WH ЕС

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

TSEK VHR EC HEAT RECOVERY UNITS

ROOFTM. roof products. Roof products for a complete ventilation system HOME VENTILATION

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

RIRS H. AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła. Вентиляционные агрегаты с рекуперацией тепла

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Operating instructions and service manual. TL 5417 ROTO Toaster

VEX250H with rotary heat exchanger and EXact control system

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PERMA arm. Extraction arm. The lowest pressure loss

We simplify construction

TECHNICAL INFORMATION DanX Swimming Pool Air Management

RIRS V EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

VEX280H with rotary heat exchanger and EXact control system

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

Technical Information HXV - HRV Ventilation

DOMEKT. Residential ventilation units

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

Ecodesign in SystemairCAD

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

Ceiling diffusers. Type DLQL

THE ROAD TO A HEALTHY INDOOR CLIMATE

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Air Handling Units. Quick Guide to Danvent DV

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

GES ENERGY S GES ENERGY M

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit.

The new Xcell EC High Efficiency Range Fresh air pure and simple

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Safexpert compact og Proffesionel

GLOBAL RX. Ventilation unit with rotary heat exchanger

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

TopMaster Air Handling unit. Technical data

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

SAVE gives great indoor climate and saves energy

Product Line Introduction. Karl Zhang Technical support engineer

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Prøvning af installationers brandmodstandsevne Del 10: Røgspjæld

User and service manual. Grill plate GL MAXI-series

Swegon CASA. duct coils for heating. the supply air

VEX350 / VEX360 Air handling units with counter flow heat exchangers

VEKA ver C SUPPLY AIR UNIT IINSTALLATION AND MAINTENANCE

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

Technical Information HCV - HCH Demand-controlled home ventilation

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

VERSO Air Handling Units

Air Handling Units. Geniox. Quick guide

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

Cassette units Model Comfort Circle. - heating - cooling - ventilation

VEX100 series Air handling units with cross-flow heat exchanger

Transcription:

Ventilationsaggregater med krydsvarmeveksler Oversigt Tekniske data Geovent aggregater med varmegenvinding udmærker sig ved: Effektive, støjsvage EC-ventilatorer Regulering af luftmængde Mulighed for el- eller vandvarmeflade Styring af indblæsningstemperatur Lavt støjniveau Lydisolering Filter på indblæsning og udsugning Leveres med avanceret betjeningspanel HOVEDGADEN 86 DK-8831 LØGSTRUP Tlf.: (+45) 8664 2211 e-mail: salg@geovent.dk

Udvalgt tilbehør Spjældaktuator Termostat Blandepunkt 3 og 3 vejs ventiler Støjdæmper Betjeningspanel Betjeningspanel Programérbar controller Spjæld Monteringsmuffe 2

KHE 400, 700, 1000, 1500,1900 EC Ventilationsaggregatet KHE H 3.0 har en særdeles effektiv krydsvarmeveksler. Aggregatet anvendes til ventilation af huse og andre opvarmede områder. Effektive og støjsvage ventilatorer. Virkningsgrad på op til 65%. El- eller vandvarmer. Regulerbar luftmængde. Regulerbar indblæsningstemperatur. Anti-frost beskyttelse af varmveksleren. Lavt støjniveau. Alle aggregater er testede. Støjdæmpende isolering af kabinettet - 50mm. Alle varianter af KHE 400H 1900H 3.0 kan styres med Flex, S-touch og TCP betjeningspanel. KHE 400H 1900H 3.0 pulverlakeret kabinet RAL 7040. Nem montering. Aggregater med krydspladeveksler KHE 1900 H E 3.0 Equipped with new PRV V1.1 control board Heater type (E - integrated electrical heater; W - optional water heater) Housing type (V - vertical, H - horozontal, P - under - ceiling) AHU size according to air flow range m 3 /h AHU with plate heat-exchanger Type Dimensions [mm] L W H ød H 1 H 2 F KHE 400HE 3.0 1000 354 600 160 30 55 30 KHE 400HW 3.0 1170 354 600 160 30 55 30 KHE 700HE 3.0 1170 504 600 250 30 55 40 KHE 700HW 3.0 1320 504 600 250 30 55 40 KHE 1000HE/HW 3.0 1500 645 865 315 70-40 KHE 1500HE/HW 3.0 1500 645 865 315 70-40 KHE 1900HE/HW 3.0 1800 795 1050 400 70-65 3

KHE 400, 700, 1000 Elvarmeflade KHE 400HE 3.0 KHE 700HE 3.0 KHE 1000HE 3.0 56 111 167 222 278 333 389 Calculated temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -20 C 400HE 3.0 700HE 3.0 1000HE 3.0 Heater -phase/voltage [50Hz/VAC] ~1, 230 ~1, 230 ~3, 400 -power consumption [kw] 2,0 3 6,0 Pre-heater for heat exchanger [kw] 1,0 1,2 - Fans -phase/voltage [50Hz/VAC] ~1, 230 ~1, 230 ~1, 230 -power/current [kw/a] 0,162/0,70 0,230/1,0 0,230/1,0 -fan speed [min -1 ] 2100 2000 2650 -power/current [kw/a] 0,199/0,87 0,230/1,0 0,226/0,98 -fan speed [min -1 ] 1850 2000 2650 Motor protection class IP-54/IP-44 IP-54 IP-44 Thermal efficiency 60% 60% 54% Max power consumption [kw/a] 3,36/14,61 4,66/15,91 6,45/10,64 Automatic control integrated integrated integrated Filter class - G4 G4 M5 M5 M5 M5 Thermal insulation [mm] 50 50 50 Weight [kg] 48,0 57,0 152,0 Comply with ERP 2013 + + - Designed for operation indoors only KHE 400HE 3.0 KHE 700HE 3.0 KHE 1000HE 3.0 KHE 400HE 3.0 ver. KHE 700HE 3.0 ver. KHE 1000HE 3.0 (convertible) ver. 400HE 3.0 700HE 3.0 Supply 74 66 65 67 68 64 63 55 Extract 60 51 55 57 51 45 40 36 Surrounding 53 45 46 47 46 43 40 36 Measured at 622 m 3 /h, 100 Pa 1000HE 3.0 Supply 72 69 63 62 64 61 59 55 Extract 56 49 51 52 45 44 39 35 Surrounding 51 42 45 46 43 41 37 35 Measured at 413 m 3 /h, 120 Pa Supply 75 69 65 69 70 66 59 56 Extract 58 52 50 53 51 46 41 35 Surrounding 55 48 45 50 48 44 38 34 Measured at 1050 m 3 /h, 90 Pa 4

KHE 400, 700, 1000 Vandvarmeflade 56 111 167 222 278 333 389 KHE 400HW 3.0 KHE 700HW 3.0 KHE 1000HW 3.0 56 111 167 222 278 333 389 Calculated temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -20 C Water heater -power [kw] 2,7 4,7 6,75 -water temp. T in /T out [ o C] 80/60 80/60 80/60 -water flow rate [l/s] 0,03 0,06 0,08 -water pressure drop [kpa] 2,47 4,9 1,8 -kvs value [m³/h] 0,7 1 2,2 Pre-heater for heat exchanger [kw] 1 1,2 - Fans -phase/voltage [50Hz/VAC] ~1, 230 ~1, 230 ~1, 230 -power/current [kw/a] 0,161/0,7 0,233/1,0 0,214/0,93 -fan speed [min -1 ] 2100 2000 2650 -power/current [kw/a] 0,194/0,85 0,222/0,97 0,228/1,0 -fan speed [min -1 ] 1850 2000 2650 Motor protection class IP-54 IP-54 IP-44 Thermal efficiency 60% 60% 54% Max power consumption [kw/a] 1,35/5,90 1,65/7,19 0,44/1,98 Automatic control integrated integrated integrated Filter class - G4 G4 M5 M5 M5 M5 Thermal insulation [mm] 50 50 50 Weight [kg] 48,0 57,0 152,0 Comply with ERP 2013 + + - Designed for operation indoors only KHE 400HW 3.0 KHE 700HW 3.0 KHE 1000HW 3.0 400HW 3.0 700HW 3.0 1000HW 3.0 AIR HANDLING UNITS KHE 400HW 3.0 ver. KHE 700HW 3.0 ver. KHE 1000HW 3.0 (convertible) ver. 400HW 3.0 700HW 3.0 Supply 74 66 65 67 68 64 63 55 Extract 60 51 55 57 51 45 40 36 Surrounding 53 45 46 47 46 43 40 36 Measured at 622 m 3 /h, 100 Pa 1000HW 3.0 Supply 72 69 63 62 64 61 59 55 Extract 56 49 51 52 45 44 39 35 Surrounding 51 42 45 46 43 41 37 35 Measured at 413 m 3 /h, 120 Pa Supply 75 69 65 69 70 66 59 56 Extract 58 52 50 53 51 46 41 35 Surrounding 55 48 45 50 48 44 38 34 Measured at 1050 m 3 /h, 90 Pa Used water outlet Water inlet 5

KHE 1500, 1900 Elvarmeflade KHE 1500HE 3.0 KHE 1900HE 3.0 83 167 250 333 417 500 583 KHE 1500HE 3.0 KHE 1900HE 3.0 Calculated temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -20 C 1500HE 3.0 1900HE 3.0 Heater -phase/voltage [50Hz/VAC] ~3, 400 ~3, 400 -power consumption [kw] 9,0 15,0 Fans -phase/voltage [50Hz/VAC] ~1, 230 ~1, 230 -power/current [kw/a] 0,356/1,55 0,669/2,95 -fan speed [min -1 ] 2750 2830 -power/current [kw/a] 0,369/1,6 0,669/2,95 -fan speed [min -1 ] 2750 2830 Motor protection class IP-44 IP-54 Thermal efficiency 54% 60% Max power consumption [kw/a] 9,725/16,14 16,34/27,55 Automatic control integrated integrated Filter class - M5 M5 M5 M5 Thermal insulation [mm] 50 50 Weight [kg] 152,0 214,0 Comply with ERP 2013 - - Designed for operation indoors only KHE 1500HE 3.0 (convertible) ver. KHE 1900HE 3.0 (convertible) ver. 1500HE 3.0 Supply 76 67 66 70 70 67 62 56 Extract 58 51 49 53 51 45 40 33 Surrounding 57 49 50 52 48 45 41 37 Measured at 1380 m 3 /h, 70 Pa 1900HE 3.0 Supply 83 65 69 75 79 77 71 63 Extract 68 53 59 65 61 52 47 41 Surrounding 60 46 51 54 56 53 47 42 Measured at 1885 m 3 /h, 120 Pa 6

KHE 1500, 1900 Vandvarmeflade KHE 1500HW.0 KHE1900HW 3.0 83 167 250 333 417 500 583 KHE 1500HW 3.0 KHE 1900HW 3.0 Calculated temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -20 C Water heater -power [kw] 10,12 12,82 -water temp. T in /T out [ o C] 80/60 80/60 -water flow rate [l/s] 0,12 0,16 -water pressure drop [kpa] 3,3 4,70 -kvs value [m³/h] 2,4 2,7 Fans -phase/voltage [50Hz/VAC] ~1, 230 ~1, 230 -power/current [kw/a] 0,351/1,52 0,669/2,95 -fan speed [min -1 ] 2750 2830 -power/current [kw/a] 0,368/1,6 0,669/2,95 -fan speed [min -1 ] 2750 2830 Motor protection class IP-44 IP-55 Thermal efficiency 54% 60% Max power consumption [kw/a] 0,72/3,12 1,338/5,9 Automatic control integrated integrated Filter class - M5 M5 M5 M5 Thermal insulation [mm] 50 50 Weight [kg] 152,0 216,0 Comply with ERP 2013 - - Designed for operation indoors only 1500HW 3.0 1900HW 3.0 KHE 1500HW 3.0 (convertible) ver. KHE 1900HW 3.0 (convertible) ver. Used water outlet Water inlet 1500HW 3.0 Supply 76 67 66 70 70 67 62 56 Extract 58 51 49 53 51 45 40 33 Surrounding 57 49 50 52 48 45 41 37 Measured at 1250 m 3 /h, 70 Pa 1900HW 3.0 Supply 86 65 68 77 82 81 75 66 Extract 71 57 59 69 64 55 49 44 Surrounding 63 48 50 55 57 56 50 45 Measured at 1812 m 3 /h, 124 Pa 7

KHE 2500, 3500, 5500 EC Ventilationsaggregatet KHE H EC 3.0 har en særdeles effektiv krydsvarmeveksler. Aggregatet anvendes til ventilation af huse og andre opvarmede områder. Energibesparende, støjsvage EC-ventilatorer. Virkningsgrad op til 65%. Integreret elvarme eller valgfri vandvarme / DX varmer/køler. Regulerbar luftmængde. Regulerbar indblæsningstemperatur. Motoriseret by-pass spjæld. Anti-frost beskyttelse af varmveksleren. Støjdæmpende isolering af kabinettet 50mm. Alle varianter kan styres med Flex, S-touch eller TCP betjeningspanel Pulverlakeret kabinet RAL 7040. Nem og hurtig montering. Mulighed for Siemens Climatix/REGIN kontrolsystem. Filter overvågning Elektrisk varme kontrol 0-10V. Mulighed for CO 2 -, tryk- og flow-transmitter. Mulighed for tag- og udsugningsafdækning. KHE 5500H EC 3.0 leveres som 2 sektioner. KHE 2500H EC 3.0, KHE 3500H EC 3.0 KHE 5500H EC 3.0 KHE 2500 H E R EC 3.0 Equiped with new PRV V2.2 control board AHU with EC motor and efficient cross flow heat exchanger Air intake side if not convertible (R - right; L- left) Heater type (E - integrated electrical heater; W - optional water heater on the duct) Hausing type (V - vertical, H - horozontal, P - under - ceiling) AHU size according to air flow range m 3 /h AHU range with plate heat exchanger Type Dimensions [mm] L L 1 L 2 W W 1 D G H H 1 H 2 H 3 H 4 F KHE 2500 HE/HW EC 3.0 2100 - - 900 490 350 600 1355 387 327 108 180 51 KHE 3500 HE/HW EC 3.0 2100 - - 900 490 350 600 1355 387 327 108 180 51 KHE 5500 HE/HW EC 3.0 2545 1570 975 1110 590 500 800 1400 395 370 127 180 51 8

KHE 2500HE EC 3.0 Performance Power consumption Elvarmeflade Supply air Exhaust air Specific fan power Power [W] Power [W] KHE 2500HE EC 3.0 (convertible) ver. Article No. 2500HE EC 3.0 Heater -phase/voltage [50Hz/VAC] ~3,400 -power consumption [kw] 18 EC Fans -phase/voltage [50Hz/VAC] ~1,230 -power/current [kw/a] 0,72/3,18 -fan speed [min -1 ] 2800 -power/current [kw/a] 0,72/3,19 -fan speed [min -1 ] 2800 Motor protection class IP-54 Thermal efficiency 61% Max power consumption [kw/a] 19,45/32,5 Automatic control integrated Filter class - F7 M5 Thermal insulation [mm] 50 Weight [kg] 340,0 Comply with ERP 2013;2015 + 2500HE EC 3.0 Version 2500HE EC 3.0 Integrated electrical heater. Integrated electrical heater and motorized 2500HE EC 3.0 and dampers. * Calculated according EN 13141-7. **For temperatures lower than recommended use electrical pre-heater to ensure balanced operation. Supply 84 65 77 78 79 74 68 67 Extract 66 44 63 61 54 52 46 40 Surrounding 62 45 57 59 55 51 45 43 Measured at 2757 m 3 /h, 121 Pa Temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -15 C / -7 C / 2 C / 7 C total power for & fans kw SFP= x 3600 air flow m 3 /h Temperature efficiency Certifications EUROVENT certified counter flow heat exchanger performance 9

KHE 2500HW EC 3.0 Performance Power consumption Vandvarmeflade Supply air Exhaust air Specific fan power Power [W] Power [W] KHE 2500HW EC 3.0 (convertible) ver. Article No. 2500HW EC 3.0 Water heater SVS 600x350 or Comfort Box 600x350 EC Fans -phase/voltage [50Hz/VAC] ~1,230 -power/current [kw/a] 0,72/3,18 -fan speed [min -1 ] 2800 -power/current [kw/a] 0,72/3,19 -fan speed [min -1 ] 2800 Motor protection class IP-54 Thermal efficiency 61% Max power consumption [kw/a] 1,45/6,47 Automatic control integrated Filter class - F7 M5 Thermal insulation [mm] 50 Weight [kg] 337,0 Comply with ERP 2013;2015 + 2500HW EC 3.0 Version 2500HW EC 3.0 Optional water heater. Optional water heater and motorized 2500HW EC 3.0 and dampers. * Calculated according EN 13141-7. **For temperatures lower than recommended use electrical pre-heater to ensure balanced operation. Supply 84 65 77 78 79 74 68 67 Extract 66 44 63 61 54 52 46 40 Surrounding 62 45 57 59 55 51 45 43 Measured at 2757 m 3 /h, 121 Pa Temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -15 C / -7 C / 2 C / 7 C total power for & fans kw SFP= x 3600 air flow m 3 /h Temperature efficiency Certifications EUROVENT certified counter flow heat exchanger performance 10

KHE 3500HE EC 3.0 Performance Power consumption Elvarmeflade Supply air Power [W] KHE 3500HE EC 3.0 (convertible) ver. Exhaust air Specific fan power Power [W] Article No. 3500HE EC 3.0 Heater -phase/voltage [50Hz/VAC] ~3,400 -power consumption [kw] 24 EC Fans -phase/voltage [50Hz/VAC] ~1,230 -power/current [kw/a] 1,37/6,12 -fan speed [min -1 ] 2390 -power/current [kw/a] 1,41/6,35 -fan speed [min -1 ] 2390 Motor protection class IP-54 Thermal efficiency 59% Max power consumption [kw/a] 26,8/47,1 Automatic control integrated Filter class - F7 M5 Thermal insulation [mm] 50 Weight [kg] 340,0 Comply with ERP 2013;2015 + 3500HE EC 3.0 Version 3500HE EC 3.0 Integrated electrical heater. Integrated electrical heater and motorized and 3500HE EC 3.0 dampers. * Calculated according EN 13141-7. **For temperatures lower than recommended use electrical pre-heater to ensure balanced operation. Supply 86 63 79 80 81 77 76 64 Extract 72 60 69 66 62 62 54 43 Surrounding 68 57 65 62 58 55 52 46 Measured at 4006 m 3 /h, 198 Pa Temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -15 C / -7 C / 2 C / 7 C SFP= total power for & fans kw air flow m 3 /h Temperature efficiency x 3600 Certifications EUROVENT certified counter flow heat exchanger performance 11

KHE 3500HW EC 3.0 Performance Power consumption Vandvarmeflade Supply air Exhaust air Power [W] Power [W] KHE 3500HW EC 3.0 (convertible) ver. Article No. Version 3500HW EC 3.0 Optional water heater. Optional water heater and motorized 3500HW EC 3.0 and dampers. 3500HW EC 3.0 Water heater SVS 600x350 or Comfort Box 600x350 EC Fans -phase/voltage [50Hz/VAC] ~1,230 -power/current [kw/a] 1,37/6,12 -fan speed [min -1 ] 2390 -power/current [kw/a] 1,41/6,35 -fan speed [min -1 ] 2390 Motor protection class IP-54 Thermal efficiency 59% Max power consumption [kw/a] 2,78/12 Automatic control integrated Filter class - F7 M5 Thermal insulation [mm] 50 Weight [kg] 337,0 Comply with ERP 2013;2015 + Specific fan power * Calculated according EN 13141-7. **For temperatures lower than recommended use electrical pre-heater to ensure balanced operation. 3500HW EC 3.0 Supply 86 63 79 80 81 77 76 64 Extract 72 60 69 66 62 62 54 43 Surrounding 68 57 65 62 58 55 52 46 Measured at 4006 m 3 /h, 198 Pa Temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -15 C / -7 C / 2 C / 7 C total power for & fans kw SFP= x 3600 air flow m 3 /h Temperature efficiency Certifications EUROVENT certified counter flow heat exchanger performance 12

KHE 5500HE EC 3.0 Performance Power consumption Elvarmeflade Supply air Exhaust air Specific fan power Power [W] Power [W] KHE 5500HER EC 3.0 Air intake side (L- left) Article No. 5500HE EC 3.0 Heater -phase/voltage [50Hz/VAC] ~3,400 -power consumption [kw] 30 EC Fans -phase/voltage [50Hz/VAC] ~3,400 -power/current [kw/a] 2,03/3,24 -fan speed [min -1 ] 2180 -power/current [kw/a] 2,05/3,24 -fan speed [min -1 ] 2180 Motor protection class IP-54 Thermal efficiency 60% Max power consumption [kw/a] 34,1/50 Automatic control integrated Filter class - F7 M5 Thermal insulation [mm] 50 Weight [kg] 480,0 Comply with ERP 2013;2015 + 5500HE EC 3.0 Version Right-hand maintenace version with 5500HER EC 3.0 integrated electrical heater. Integrated electrical heater and motorized and 5500HER EC 3.0 dampers. * Calculated according EN 13141-7. **For temperatures lower than recommended use electrical pre-heater to ensure balanced operation. Supply 89 70 81 83 85 81 77 73 Extract 75 65 72 69 68 62 53 52 Surrounding 79 60 72 74 73 69 64 61 Measured at 5788 m 3 /h, 211 Pa Temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -15 C / -7 C / 2 C / 7 C total power for & fans kw SFP= x 3600 air flow m 3 /h Temperature efficiency Certifications EUROVENT certified counter flow heat exchanger performance 13

KHE 5500HW EC 3.0 Performance Power consumption Vandvarmeflade Supply air Power [W] KHE 5500HWR EC 3.0 Air intake side (R- right) Exhaust air Power [W] Article No. 5500HW EC 3.0 Water heater SVS 800x500 or Comfort Box 800x500 EC Fans -phase/voltage [50Hz/VAC] ~3,400 -power/current [kw/a] 2,03/3,24 -fan speed [min -1 ] 2180 -power/current [kw/a] 2,05/3,24 -fan speed [min -1 ] 2180 Motor protection class IP-54 Thermal efficiency 60% Max power consumption [kw/a] 4,1/6,64 Automatic control integrated Filter class - F7 M5 Thermal insulation [mm] 50 Weight [kg] 477,0 Comply with ERP 2013;2015 + 5500HW EC 2.0 Version Right-hand maintenace version prepared for optional water heater. 5500HWR EC 3.0 Optional water heater and motorized 5500HWR EC 3.0 and dampers. * Calculated according EN 13141-7. **For temperatures lower than recommended use electrical pre-heater to ensure balanced operation. Supply 89 70 81 83 85 81 77 73 Extract 75 65 72 69 68 62 53 52 Surrounding 79 60 72 74 73 69 64 61 Measured at 5788 m 3 /h, 211 Pa Specific fan power Temperature efficiency (balanced mass flow) EN 13141-7: Outdoor air = -15 C / -7 C / 2 C / 7 C SFP= total power for & fans kw air flow m 3 /h Temperature efficiency x 3600 Certifications EUROVENT certified counter flow heat exchanger performance 14

Komponenter. Her et eksempel: KHE 2500 med el-varmeflade. 1. Kabinet 2. Kontrolboks 3. Afkastspjæld 4. Aktuator for afkastspjæld 5. Temperaturføler for afkastluft 6. Filter for afkastluft 7. By-pass spjæld 8. Aktuator for by-pass spjæld 9. Varmeveksler 10. Filter for indtagsluft 11. Ventilator for afkastluft 12. Indtagsspjæld 13. Aktuator for indtagsspjæld 14. Ventilator for indtagsluft 15. Temperaturføler for tilluft 16. Elvarmeflade 15

WWW.GEOVENT.DK HOVEDGADEN 86 DK-8831 LØGSTRUP Tlf.: (+45) 8664 2211 e-mail: salg@geovent.dk