Панели. Autroprime. Технические характеристики

Similar documents
Панели. AutroSafe 4. Технические характеристики

AUTRONICA. Панели для систем голосового оповещения

1943P01. Solar Impact Sensor. Sensor for acquiring the impact of solar radiation Output signal DC V 2-wire current output 4...

сайт: эл. почта: Use RAB11 RAB11.. For 2-pipe fan coils

сайт: эл. почта: Use RAB21 RAB21.. For two-pipe fan coils

Installation Handbook Autroprime Interactive Fire Detection System

Indoor Air Quality Controller

MANUAL Overflow sensor NVF-104/34-PF

user manual Non-invasive Ultrasonic Flow Monitor KATflow 10 M E

Price list for production of Design Bureau "Fizelektronpribor"

Kolmeks. Каталог. Аксессуары. По вопросам продаж и поддержки обращайтесь:

etron M100

PRODUCT CATALOGUE. Autronica Fire and Security AS Petrochemical, Oil & Gas.

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

System Description Autroprime Interactive Fire Detection System

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

SINGLE MONITORED INPUT UNIT BN-303

System 800 Addressable Fire Detection & Alarm System

Fire control panels FC726 FC726-XA

Intelligent addressable fire alarm control panel

AUTROSAFE. An interactive fire detection system for larger vessels

Intelligent Security & Fire Ltd

Fire control panel detect 3004 plus and accessories

ZXSe Range Data Sheet

AUTROSAFE 4 A new level in interactive fire detection systems

On the job around the clock 24/7: Fire detection systems

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Fire and Gas Monitoring Panel ST7-HV

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

BS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE

Excel-EN Conventional Fire Control Panel

Easy Reliable Flexible. Interactive fire detection system

Installation Handbook. Interactive Fire Alarm System Release 3. Operator Panel, BS-330. Protecting life, environment and property...

Technical Manual. Level Alarm Unit CARLA & WIDS

System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG)

ZSC100 Gas Detection and Alarm System Controller

Fire control panels FC360

DRAFT 20 October 2014

FC722 Fire control panel

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire Detection Systems Product Catalogue (Version )

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

The EN54 Part 2, 4 and 13 Fire System

Installation, Operating and Maintenance Manual

Carbon Monoxide Transmitter

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Product Data Sheet. Remote Terminals. Features:

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

FC723 Fire control panel

Components Brochure DX CONNEXION

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

The EN54 Part 2 & 4 Fire System

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

21-light Remote Annunciator. Owner s Manual

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

M1000 Alarm Annunciator

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

System 9000TS Sequence of Events Recorder

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

M2500 Engine Controller Installation Manual

For Complete Fire and Gas Solutions

FC724 Fire control panel

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Autronica Fire and Security AS ID:

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

FC724 Fire control panel

FC722 Fire control panel

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

FireNET Plus Wiring Instructions

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Document No Issue 4 user manual

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Advanced FireAlarm Panel 1-4Loop

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

ModBus DE-1 INSTALLATION AND USER MANUAL

Gas Detection System TOX ALARM DG2000-Garage

Transcription:

Панели Autroprime Технические характеристики Архангельск (818)-90- Астана (1)-1 Белгород ()0-- Брянск (8)9-0- Владивосток ()9-8-1 Волгоград (8)8-0-8 Вологда (81)-1-9 Воронеж ()0-1- Екатеринбург ()8--89 Иваново (9)--0 Ижевск (1)-0-8 Казань (8)0-01-8 Калининград (01)-0-81 Калуга (8)9-- Кемерово (8)-0- Киров (8)8-0-0 Краснодар (81)0-0-90 Красноярск (91)0--1 Курск (1)-1-0 Липецк ()-0-81 Магнитогорск (19)-0-1 Москва (9)8-0-0 Мурманск (81)9--9 Набережные Челны (8)0--1 Нижний Новгород (81)9-08-1 Новокузнецк (8)0--81 Новосибирск (8)-8- Орел (8)-- Оренбург ()-8-0 Пенза (81)-1-1 Пермь ()0-81- Ростов-на-Дону (8)08-18-1 Рязань (91)-1- Самара (8)0-0-1 Санкт-Петербург (81)09--0 Саратов (8)9-8-8 Смоленск (81)9-1- Сочи (8)--1 Ставрополь (8)0--1 Тверь (8)-1- Томск (8)98-1- Тула (8)-0-9 Тюмень ()-1-18 Ульяновск (8)--9 Уфа ()9-8-1 Челябинск (1)0-0-1 Череповец (80)9-0- Ярославль (8)9--9 Единый адрес для всех регионов: acn@nt-rt.ru www.autronica.nt-rt.ru

Fire Alarm Control Panel - BS-00 Autroprime Interactive Fire Detection System Product datasheet Features SelfVerify function for automatic testing of detectors Automatic setup Automatic addressing of detectors Two loops USB for data transfer to/from memory stick User-friendly display and operator controls Backlit operating buttons. Text display suitable for night-time operation Surface mounting Designed to meet EN requirements and conforms to CE standards Complies with environmental conditions of IEC- 1-- class k Application/Description The BS-00 is an integrated fire alarm control panel for small to medium sized installations. The panel serves as a stand-alone panel. A maximum of 8 additional panels can be freely mixed and connected to the Fire Alarm Control Panel via the RS-8 Panel Bus, including Repeater Panels BS-11, Information Panels BV- 10, Fire Brigade Panels BU-10 and Mimic Drivers BUR-00. All alarm handling and system features can be configured, controlled and monitored from the panel. The panel can accommodate up to a maximum of two detection loops. The loops support most of AutroSafe detectors, several types of I/O devices for monitored outputs, open collector outputs, galvanic isolated inputs and monitored inputs. It has a A power module for battery charging, and a built-in emergency battery. The panel is menu operated on a 8-line display, with 0 characters per line. The Operator Panel (BS-10), which is an integrated part of the BS-00 panel, can also be mounted separately outside the cabinet. Capacity Maximum number of: Detection loops per fire alarm control panel Loop Units per detection loop 1 Loop Units per branch on a detection loop Loop sounders per detection loop 0 Fire Brigade/Information/Repeater Panels and Mimic Drivers per fire alarm control panel Serial ports 1 Ethernet 1 USB host ports Languages supported 1 8 Indicators 8x0 character alphanumeric display Alarm, more alarms, Pre-alarm, Remote call, Remote Call Response, Fault, Disabled Function, Supervisory Condition, Test condition, System Fault, Power, Delayed Activation, Annunciator Fault, Remote Call Fault, Annunciator Disabled, Remote Call Disabled Internal buzzer Operator Controls More Events, Mute Panel, Silence, Reset, Prolong Delay, Activate Outputs Keypad with navigational functions (Cancel/Back, Enter, directional keys (arrow up/down and left/right)), Function and Select (MultiSelect) key Backlit buttons and text Fireman s key 11-P-BS00/CGB, Rev. B, 009-11-1 Protecting life, environment and property

Fire Alarm Control Panel BS-00 Panel Bus Connection (connector J1 and J1) Technical specifications Dimensions (mm) 0 x x 10 Weight Materials Mounting Protection class 9 kg (excluding batteries) Steel cabinet, ABS/PC moulded front Surface, flush or rack mounting IEC-9 / IP0 Operating temperature -1 C to C Storage temperature - 0 C to 0 C Humidity Power supply Current consumption Loops Capacity- loop units Batteries Communication 0 to 0% non-condensing 11/0VAC,A/ 1, A 10% / -1% Frequency: 0/0Hz 00mA at VDC 1 per loop x 1V= V not included, maximum 1 Ah Built-in TCP/IP (Ethernet) for Modbus, Serial port Addressing The Panel The rotary switch on the rear side of the operator panel (on the left side of the connector J1 and J1) is used to address the panel. The address must be set to 0. Part number 11-BS-00 Description Fire Alarm Control Panel Stand-alone Panel Panels interconnected on the RS-8 Panel Bus Fire Alarm Control Panel BS-00 RS-8 Panel bus BU-10 BV-10 ESPA communication protocol or NMEA protocol for VDR systems (RS-, RS-/8) BS-11 Modbus RTU protocol (serial/ethernet) AUTRONICA FIRE AND SECURITY AS

Fire Alarm Control Panel BS-00M Autroprime interactive fire detection system Product datasheet Features SelfVerify-function for automatic testing of detectors Automatic setup Automatic addressing of detectors Four loops Built in changeover for primary/emergency mains power USB for data transfer to/from memory stick. User-friendly display and operator controls Back-lit operating buttons. Text display suitable for nighttime operation Surface mounting. The integrated panel can be mounted separately in a 19 rack or console Designed to meet EN and SOLAS requirements, MED ( wheel-mark ) and CPD certified Complies with environmental conditions of IEC-1-- class k Output to VDR and Modbus Printed Getting started manual included Applications/Description The BS-00M is an integrated Fire Alarm Control Panel for small-to-medium-sized installations. The panel is specifically designed for use in maritime applications and meets the SOLAS requirements. The panel serves as a stand-alone panel. A maximum of 8 additional panels can be freely mixed and connected to the Fire Alarm Control Panel via the RS-8 Panel Bus, including Repeater Panels BS-11, Information Panels BV-10, Fire Brigade Panels BU-10 and Mimic Drivers BUR-00. All alarm handling and system features can be configured, controlled and monitored from the panel. The panel can accommodate up to a maximum of four detection loops. The loops support most of AutroSafe detectors, several types of I/O devices for monitored outputs, open collector outputs, galvanic isolated inputs and monitored inputs. It has a A power module for battery charging. The panel is menu operated on a 8-line display, with 0 characters per line. The Operator Panel (BS-10), which is an integrated part of the BS-00M panel, can also be mounted separately outside the cabinet. Indicators 8 x 0-character alphanumeric display Alarm, More Alarms, Pre-Alarm, Remote Call, Remote Call Response, Fault, Disabled Function, Supervisory Condition, Test Condition, System Fault, Power, Delayed Activation, Annunciator Fault, Remote Call Fault, Annunciator Disabled, Remote Call Disabled Internal buzzer Operator Controls More Events, Mute, Silence, Reset, Block, Activate Outputs Keypad with alphanumeric characters and navigational functions (Cancel/Back, Enter, directional keys (arrow up/down and left/right), Function and Select (MultiSelect) key Back-lit buttons and text Fireman s key Capacity, maximum number of: Detection loops per fire alarm control panel Loop units per detection loop 1 Loop units per branch on a detection loop Loop sounders per detection loop 0 Fire Brigade/Information/Repeater Panels and Mimic Drivers per fire alarm control panel Serial ports 1 Ethernet 1 USB host ports Languages supported 1 Relay outputs Monitored outputs ( V) Non-monitored outputs (OC) Inputs 8 11-P-BS00M/CGB, Rev. E, 010-09- Protecting life, environment and property

Fire Alarm Control Panel BS-00M Technical specifications Dimensions (mm) 0 x x 10 Weight Materials Mounting Protection class Operating temperature Storage temperature Humidity 9 kg (excluding batteries) Steel cabinet, ABS/PC moulded front Surface, flush or rack mounting IEC-9 / IP -1 o C to 0 o C -0 o C to 0 o C 0 to 9% non-condensing Power supply 110/0 VAC, 10% / -1%,A/1,A, Frequency: 0/0Hz Current consumption Loops Capacity loop units Batteries Communication 0mA at 11/0 VDC 1 per loop x 1V = V (not included) Built-in TCP/IP (Ethernet) for Modbus, Serial Port Part number Description 11-1118 BS-00M Fire Alarm Panel, 110VAC / 0VAC 11-1119 BS-00M Fire Alarm Panel, 0VAC 11-1110 BS-00M Fire Alarm Panel, 110VAC Factory set outputs: (For functionality/configuration setup, see Getting started manual ch. ) Relay no. 1: Activated at alarm / Off at Reset Relay no. : Activated at fault / Off at Reset Mon. output 1 and : Activated at alarm / min. delay / Off at Silence Additional outputs/inputs (no factory setting): (For functionality/configuration setup, see Getting started manual ch. ) Non-monitored outputs 1 and Monitored inputs 1 and Non-monitored inputs 1 and Connections 11-1119 (0VAC) and 11-1110 (110VAC) X1 X1 Description 1 Mains 110/0 VAC Mains 110/0 VAC Emergency 110/0 VAC Emergency 110/0 VAC Earth K1 Change-over Relay K1 Mains Fault K1 Emergency Fault X X X Description 1 External V External V - External V External V - Battery V Battery V - AUTRONICA FIRE AND SECURITY AS

Repeater panel BS-11 Autroprime Interactive Fire Detection System Product datasheet Features User-friendly display and operator controls Backlit operating buttons. Text display suitable for night-time operation Surface mounting Designed to meet EN- requirements, and conforms to CE standards Complies with environmental conditions of IEC-1-- class k Application/Description Repeater Panel BS-11 is identical (with the exception of an alphanumeric keypad) to the operator panel BS-10, which is an integrated part of the Fire Alarm Control Panel BS-00. All alarm handling and system features can be controlled and monitored from the panel. Configuration is not possible. The panel is intended for the following purposes: Read information on events Accept events Read events in the log The panel is menu operated on a 8-line display, with 0 characters per line. The BS-11 panel communicates with the Fire Alarm Control Panel BS-00, information Panels BV-10, other Repeater Panels BS-11, Fire Brigade Panels BU-10 and Mimic Drivers BUR-00 on an RS-8 panel bus. Capacity A maximum of 8 additional panels can be freely mixed and connected to the Fire Alarm Panel via the RS-8 Panel Bus, including Repeater Panels BS-11, Information Panels BV-10, Fire brigade Panels BU-10 and Mimic Drivers BUR-00 Panel Bus Connection (connector J1 and J1) J1 J1 Indicators 8 x 0 character alphanumeric display Alarm, More alarms, Pre-alarm, Remote call, Remote condition, Test condition, System fault, Power, Delayed activation, Annunciator disabled, Remote call disabled Internal buzzer V in1 0V in1 V in 0V in A1 B1 Panel Bus In GND V in1 0V in1 V in 0V in A B Panel Bus Out GND Operator Controls More events, Mute panel, Silence, Reset, Prolong delay. Activate outputs Keypad with navigational functions (cancel/back, enter, directional keys (arrow up/down and left/right), Function and select (MultiSelect) key Back-lit buttons and text Fireman s key Addressing the panel The rotary switch on the rear side of the panel (on the left side of the connector J1 and J1) is used to address the panel (1-9). 11-P-BS11/CGB, Rev.A, 010-09- Protecting life, environment and property

Repeater panel BS-11 Technical specifications Dimensions (mm) 10 x 0 x Weight Materials Mounting Protection class 1,0 kg ABS/PC moulded front Surface or rack mounting IEC 9 / IP Operating temperature - 1 C to 0 C Humidity 0 to 9 % non-condensing Storage temperature - 0 C to 0 C Current consumption Power supply Communication 0mA at VDC, 00mA at lamp test (start-up) 18-0 VDC RS-8 panel bus (redundant power bus) Hole dimensions on mounting bracket. 11 9. 1 19. Part number 11-BS-11 11-UD-1 Description Repeater Panel Wall mount bracket Panels interconnected on the RS-8 panel Bus Fire Alarm Control Panel BS-00 RS-8 Panel bus BU-10 BV-10 ESPA communication protocol or NMEA protocol for VDR systems (RS-, RS-/8) BS-11 Modbus RTU protocol (serial/ethernet) AUTRONICA FIRE AND SECURITY AS

Fire Brigade Panel BU-10 Autroprime Interactive Fire Detection System Product datasheet Features User-friendly display and operator controls Backlit operating buttons. Text display suitable for night-time operation Surface mounting Designed to meet EN and LPCB requirements, and conforms to CE standards Complies with environmental conditions of IEC- 1-- class k Application/Description From the Fire Brigade Panel BU-10 it is possible to mute the panel s internal buzzer, silence sounders/bells etc. and reset the system. Only alarms are shown in the display. The panel is menu operated on a 8-line display, with 0 characters per line. The BU-10 communicates with the Fire Alarm Control Panel BS-00, Information Panels BV-10, Repeater Panels BS-11, other Fire Brigade Panels BU-10 and Mimic Drivers BUR-00 on an RS-8 panel bus. Capacity A maximum of 8 additional panels can be freely mixed and connected to the Fire Alarm Control Panel via the RS-8 panel bus, including Repeater Panels BS-11, Information Panels BV-10, Fire Brigade Panels BU-10 and mimic Drivers BUR-00 Indicators 8 x 0 character alphanumeric display Alarm, More Alarms, Pre-Alarm, Remote Call, Fault, Disabled Function, Delayed Activation, Power Internal buzzer Panel Bus Connection (connector J1 and J1) J1 J1 V in1 0V in1 V in 0V in A1 B1 GND V in1 0V in1 V in 0V in A B GND Operator Controls More Events, Mute panel, Silence, Reset Backlit buttons and text Fireman s key Panel Bus In Addressing the Panel Panel Bus Out The rotary switch on the rear side of the panel (on the left side of the connector J1 and J1) is used to address the panel (1-9) 11-P-BU10/CGB, Rev. A, 010-09- Protecting life, environment and property

Fire Brigade Panel BU-10 Technical specifications Dimensions (mm) 10 x 1 x Weight Materials Mounting Protection class 0, kg ABS/PC moulded front Surface IEC 9 / IP Operating temperature - 1 C to 0 C Humidity 0 to 9 % non-condensing Storage temperature - 0 C to 0 C Current consumption Power supply Communication 0 ma at VDC, 00 ma at lamp test (start-up) 18-0 VDC RS-8 Panel Bus (redundant power bus) Part number 11-BU-10 11-UD-1 Description Fire Brigade Panel BU-10 Wall mount bracket Panels interconnected on the RS-8 Panel Bus Fire Alarm Control Panel BS-00 RS-8 Panel bus BU-10 BV-10 ESPA communication protocol or NMEA protocol for VDR systems (RS-, RS-/8) BS-11 Modbus RTU protocol (serial/ethernet) AUTRONICA FIRE AND SECURITY AS

Information Panel BV-10 Autroprime Interactive Fire Detection System Product datasheet Features User-friendly display and operator controls Back-lit operational keys. Text display suitable for night-time operation Surface mounting Designed to meet EN requirements and conforms to CE standards Complies with environmental conditions of IEC-1-- class k Application/Description From the Information Panel BV-10 all alarm handling and system events can be monitored. The most significant events/conditions are shown in the display. The BV-10 communicates with the Fire Alarm Control Panel BS-00, Repeater Panels BS-11, Fire Brigade panels, other Information Panels BV- 10 and Mimic Driver BUR-00 on an RS-8 Panel Bus. Indicators 8 x 0 character alphanumeric display Alarm, More Alarms, Pre-Alarm, Remote Call, Remote Call Response, Fault, Disabled Function, Supervisory Condition, Test Condition, System Fault, Power Internal buzzer Operator Controls More Events, Mute Panel Capacity A maximum of 8 additional panels (including Repeater Panels/Information Panels/Fire Brigade panels) can be connected to the Fire Alarm Control Panel via the RS-8 Panel Bus. One of them can be a Mimic Driver BUR-00. Panel Bus Connection (connector J1 and J1) V in1 J1 J1 0V in1 V in 0V in A1 B1 GND V in1 0V in1 V in 0V in A B GND Panel Bus In Panel Bus Out Addressing the Panel The rotary switch on the rear side of the panel (on the left side of the connector J1 and J1) is used to address the panel (1-9). 11-P-BV10/CGB, Rev. A, 010-09- Protecting life, environment and property

Information Panel BV-10 Technical specifications Dimensions (mm) 10 x 1 x Weight Materials Mounting Protection class 0, kg ABS/PC moulded front Surface or rack mounting IEC-9 / IP Operating temperature - 1 C to 0 C Storage temperature -0 C to 0 C Humidity Current consumption Power supply Communication 0 to 9% non-condensing 0 ma at VDC, 00 ma at lamp test (start-up) 18-0 VDC RS-8 Panel Bus (redundant power bus) Hole dimensions on mounting bracket Part number 11-BV-10 11-UD-1 Description Information Panel BV-10 Wall mount bracket Panels interconnected on the RS-8 Panel Bus Fire Alarm Control Panel BS-00 RS-8 Panel bus BU-10 BV-10 ESPA communication protocol or NMEA protocol for VDR systems (RS-, RS-/8) BS-11 Modbus RTU protocol (serial/ethernet) AUTRONICA FIRE AND SECURITY AS

Mimic Driver BUR-00 Autroprime Interactive Fire Detection System Product datasheet Features 1 Mimic Driver is capable of driving current limited LEDs 1 Mimic Driver is provided with 8 standard monitored inputs A maximum of 8 Mimic Drivers can be connected to the RS-8 Panel Bus, providing a total of outputs and monitored inputs Powered by VDC, redundant, monitored Lamp test LED intensity control Snap-on to DIN rail (TS-) Designed to meet EN and SOLAS requirements, and conforms to CE standards Application/Description The BUR-00 is a Mimic Driver hat is capable of driving LEDs with series resistors on a mimic panel for additional indication of alarms. In addition, 8 standard monitored inputs can be used to reading various switches. The Mimic Driver is connected to the RS-8 Panel Bus. Power redundancy is achieved by using a daisychain connection with master and slave drivers. Switch Settings RS-8 termination and board mode switch. Switch Description S.1 RS-8 Failsafe termination S. (see description below) S. RS-8 Line termination S. BUR-00 Master/Slave select (ON: Master, OFF: Slave) Switch Settings Failsafe and line Termination Master and the last* Slave: The switches S.1, S. and S. are to be set to ON. Other Slaves: The switches S.1, S. and S. are to be set to OFF. *Refer to connection Overview Master/Slave Drivers. X Panel Bus Address Switch If S. is set to Master, X sets the panel bus address. If S. is set as a slave, X sets the RS- 8 daisy-chain slave address. The range for the switch is 1-9. Technical specifications Dimensions (mm) 181 x 1 x 0 Weight 00 Materials Polyamid / aluminium Mounting On DIN-rail (TS-) Operating temperature - 1 C to 0 C Storage temperature - 0 C to 0 C Humidity 0 to 9% non-condensing Power supply VDC (18-V) Current consumption Maximum ma Total load BUR-00 Maximum 00 ma Communication RS-8 panel bus Part number 11-BUR-00 Description Mimic Driver BUR-00 11-P-BUR00/CGB, Rev. C, 011-01-0 Protecting life, environment and property

A B A B A B A B A B A B 0 0 0 Mimic Driver BUR-00 J19 J Outp.1 8 V Outp. V Outp. V Outp. V Outp. V Outp. V Outp. V Outp.8 1 V J18 J Outp.9 8 V Outp.10 V Outp.11 V Outp.1 V Outp.1 V Outp.1 V Outp.1 V Outp.1 1 V J1 J1 Outp.1 8 V Outp.18 V Outp.19 V Outp.0 V Outp.1 V Outp. V Outp. V Outp. 1 V J1 J0 Outp. 8 V Outp. V Outp. V Outp.8 V Outp.9 V Outp.0 V Outp.1 V Outp. 1 V J1 PwrLEDV Output for Power LED Terminals for LED outputs. Each output is an open collector which is connected to 0V at activation. Each output has an adjacent terminal for V supply to the LED. Max.current per output is ma. Max.total current for all outputs: 00 ma The LED must have a serial resistor. LEDs with flying leads and built-in serial resistors are available. Output Resistor LED V Connections for Panel Bus 1 1 Inst Gnd B A 0V 0V Inst B1 A1 0V 0V Gnd V- V- 1 V- V- 1 BU/BV Mimic Panel Bus IN J BU/BV Mimic Panel Bus OUT J Connections for Slave Panels Out 1 Out RS-8 Inst. V 0V V 0V A B A B Gnd. 9 8 1 Schematics Terminals for monitored inputs Input R e s is tor 91 0 oh m Inp u t - A c tiva tion switc h E nd resistor kohm Connection Overview Master/Slave Drivers PwrLED out FaultLEDV Output for Fault LED FaultLED out SpareLED v Output for Spare LED SpareLED out 1 Not in use O utput R esistor LED V O utput R esistor LED V TuBUS in TuBUS out BUR-00, Master mode V1 V1- (Set by DIP switch) V V1 A V1- B V scr A1 B1 V1 A V1- B V 0 A B scr out 8 mon in V1 V1- V A1 B1 A B RS-8 Multidrop V1 V1- V A1 B1 A B V1 V1- V A1 B1 A B J1 Inp. - 8 J1 Terminals for Inp. Inp.8 - monitored inputs. Inp. - Inp.8 See Inp. Inp. - Schematics Inp. - Inp. Inp. Inp. - Inp.1 - Inp. Inp.1 1 Inp. - Inp. J1 Optional functions *1 To enable Light Intensity Control : move jumper 8 to position - for outputs 1-8 Circuit Board Layout BUR-00, Slave mode V1 V1- Address 1 V scr V1 V1- V J J J19 J J11 J18 J scr out 8 mon in scr BUR-00, Slave mode V1 V1- Address V V1 V1- V scr out 8 mon in scr BUR-00, Slave mode V1 V1- Address 8 V V1 V1- V scr out 8 mon in 0V V Potentiometer 1kohm Light intensity control by pot.meter *1 Light intensity control is enabled as default. Move jumper 9 to position - for outputs 9-1 Move jumper 10 to position - for outputs 1- J8 J10 J9 J1 J1 J1 J1 J0 J1 Option: Shorting to activates all outputs (Lamp Test) Normally closed. The wires from an external power supply s fault relay output can be connected to 1 and, replacing the jumper. A break in this circuit path makes the 1 panel signal a fault in the system. Total loss of power will be signalled in the system as a missing panel. Move jumper 11 to position - for outputs - J S J J1 J1 AUTRONICA FIRE AND SECURITY AS

Mimic Cabinet BUR-00 Autroprime Interactive Fire Detection System Product Datasheet Features Cabinet including 1 Mimic Driver BUR-00 and 1 programmable relays 1 Mimic Driver is capable of driving current limited LEDs A Mimic Driver is provided with 8 standard monitored inputs A maximum of 8 Mimic Drivers can be connected to the RS-8 Panel Bus, providing a total of outputs and monitored inputs Powered by V DC, redundant, monitored Lamptest LED intensity control Designed to meet EN and SOLAS requirements, and conforms to CE standards Application/Description The Mimic Cabinet BUR-00 is specifically designed for use in maritime applications. It consists of 1 Mimic Driver BUR-00 and 1 programmable relays. One Mimic Driver that is capable of driving LEDs with series resistors on a mimic panel for additional indication of alarms. In addition, 8 standard monitored inputs can be used for reading various switches. The Mimic Driver is connected to the RS-8 Panel Bus (see drawing on next page). Power redundancy is achieved by using a daisychain connection with master and slave drivers. For detailed information on the Mimic Driver, refer to separate datasheet for BUR-00. Technical specifications Dimensions (mm) 0 x x 10 Weight (g) Materials Protection class Operating Temperature Storage Temperature Humidity Power supply Current consumption Total load BUR-00 Communication 8,0 kg Steel cabinet IEC-9 / IP0-1 o C to 0 o C -0 o C to 0 o C 0 to 9% non-condensing VDC (18-V) Maximum ma Maximum 00mA RS-8 panel bus Part number Description 11-1111 BUR-00 Mimic Cabinet BUR-00 Mimic Cabinet is delivered with the following relays: 11--00.000 Relay PLC-RSC-DC/1-1 11--00.0001 Relay PLC-RSC-DC/1 11-P-BUR00CABINET/CGB, Rev. C, 010-09- Protecting life, environment and property

1 8 1 1 8 1 Mimic Cabinet BUR-00 Schematics Note: k Ohm resistors must be installed on the monitored inputs J1 and J1. A jumper must be installed between J1-1 and J1-. J1 J1 J1 J1 J18 J19 Out 1 Out Out Out Out Out Out Out 8 Out 9 Out 10 Out 11 Out 1 Out 1 Out 1 Out 1 Out 1 Out 1 Out 18 Out 19 Out 0 Out 1 Out Out Out Out Out Out Out 8 Out 9 Out 0 Out 1 Out See Manual Inp. - Inp. Inp. - Inp. Inp. - Inp. Inp. 1- Inp. 1 8 8 1 1 8 8 1 1 8 8 1 1 8 8 1 1 See Manual Inp. 8- Inp. 8 Inp. - Inp. Inp. - Inp. Inp. - Inp. J1 J1 J0 J1 J J K-1 K-1 K-1 K-1 K-1 K-11 K-10 K-9 K-8 K- K- K- K- K- K- K-1 Panel Bus Connection The drawing below shows an example of a panel bus interconnecting a BUR-00 Mimic Driver, a Fire Alarm Control Panel BS-00M, a Repeater Panel BS-11, and an Information Panel BV-10. AUTRONICA FIRE AND SECURITY AS

По вопросам продаж и поддержки обращайтесь: Архангельск (818)-90- Астана (1)-1 Белгород ()0-- Брянск (8)9-0- Владивосток ()9-8-1 Волгоград (8)8-0-8 Вологда (81)-1-9 Воронеж ()0-1- Екатеринбург ()8--89 Иваново (9)--0 Ижевск (1)-0-8 Казань (8)0-01-8 Калининград (01)-0-81 Калуга (8)9-- Кемерово (8)-0- Киров (8)8-0-0 Краснодар (81)0-0-90 Красноярск (91)0--1 Курск (1)-1-0 Липецк ()-0-81 Магнитогорск (19)-0-1 Москва (9)8-0-0 Мурманск (81)9--9 Набережные Челны (8)0--1 Нижний Новгород (81)9-08-1 Новокузнецк (8)0--81 Новосибирск (8)-8- Орел (8)-- Оренбург ()-8-0 Пенза (81)-1-1 Пермь ()0-81- Ростов-на-Дону (8)08-18-1 Рязань (91)-1- Самара (8)0-0-1 Санкт-Петербург (81)09--0 Саратов (8)9-8-8 Смоленск (81)9-1- Сочи (8)--1 Ставрополь (8)0--1 Тверь (8)-1- Томск (8)98-1- Тула (8)-0-9 Тюмень ()-1-18 Ульяновск (8)--9 Уфа ()9-8-1 Челябинск (1)0-0-1 Череповец (80)9-0- Ярославль (8)9--9 Единый адрес для всех регионов: acn@nt-rt.ru www.autronica.nt-rt.ru