Residential Duct Mount Builder s Box Media Air Cleaner

Similar documents
Installation Instructions

Installation, Start -Up, and Operating Instructions

Installation Instructions

Thermostat Remote Control & Receiver

User s Information Manual

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

user s information manual

F25F Media Air Cleaner

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Humidity Module OWNER S MANUAL. Complete Control from

Performance Non-Programmable Owner s Manual

Installation Instructions

Programmable 5-2 Day Digital Thermostat

Legacy Non-Programmable Owner s Manual

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Installation Instructions

Programmable Digital Thermostat

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Non-Programmable Digital Thermostat

Operation And Maintenance Manual MODEL SSC-7 SEMI-FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

2 - Wire Programmable Digital Thermostat

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER'S MANUAL T0140. Contents Page #

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

5+2 Day. up to HEAT COOL

Performance Series Indoor Air Quality Systems for Fan Coil Application

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

F150E Media Air Cleaner

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

1 For All Programmable Digital Thermostat

7-Day. Digital Thermostat. residential. & 2-cool

Installation Instructions Part No , Part No Part No

Performance Non-Programmable Owner's Manual

Installation Instructions

Skuttle. Indoor Air Quality Products. High Efficiency Air Cleaner Owner's Manual

USER S INFORMATION MANUAL NT-16SQ NT-20SQ

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

READ AND SAVE THESE INSTRUCTIONS

HEPAtech. Air Purifier. English. Owner s Manual. Model Hunter Fan Co.

Owner s Information Manual

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

EAC ELITE ELECTRONIC AIR CLEANER INDOOR AIR QUALITY ENGINEERING DATA FEATURES

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Owner s Information Manual

Models & Replacement Filter Information

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

Installation Instructions

F200E Charged-Media Air Cleaner

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

Installation Instructions

Installation Instructions

Programmable 5-2 Day Digital Thermostat

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

Installation Instructions Part No

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation Instructions

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the


Installation Instructions

Installation Instructions

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

High-Velocity Floor Fan

Central Air Conditioning System

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

F112A,C; F113A,C Portable Air Cleaners

INSTRUCTIONS! DO NOT DISCARD!

Fig. 1 - Unit PGD4, PGS4, WPG4

INSTALLATION AND OPERATION INSTRUCTIONS

Air Purifier. Purificador de aire. Use and Care Guide Manual de uso y cuidado. Model / Modelo : HAP52010E

Fig. 1 - Unit PHD4 and WPH4

Installation Instructions

MULTI HEAT PUMP PANEL CASSETTE TYPE DUCTLESS INVERTER INDOOR UNIT OWNER'S MANUAL. Models: CH12CC230VI CH18CC230VI CH24CC230VI

Installation Instructions

Replacement Filter Information

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Installation Instruction

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

1 HP Air Mover. Owner s Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

INSTRUCTIONS! DO NOT DISCARD!

owner s manual Air filtration system 99 % For models : EP1625 / EP2020 / EP2532

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Alen T500 HEPA Air Purifier

Perfect Air Purifiers

AirInstinct Air Purifier

Important Facts You Should Know About Your Heat Pump (602) or (520)

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

Transcription:

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Residential Duct Mount Builder s Box Media Air Cleaner Part Numbers: P102-BB14A, P102-BB20 IMPORTANT: Read entire instructions before installing the builder s box media air cleaner. IF YOU NEED HELP call toll free: 1-800-267-8305 CONTENTS SAFETY CONSIDERATIONS..................... 1 GENERAL........................................ 1 COMPONENTS..................................1,2 Cabinet........................................... 1 Filter............................................. 1 INSTALLATION..................................2,3 Location......................................... 2 Media Air Cleaner Installation.................... 2 OPERATION...................................... 4 MAINTENANCE.................................. 4 Filter Replacement............................... 4 SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Improper installation may damage media air cleaner. Recognize safety information. This is the safety alert symbol. When the safety alert symbol is present on equipment or in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or property damage. Before beginning any installation or modification, be certain that the main line electrical disconnect switch is in the OFF position. Electric shock could result. Tag disconnect switch with suitable warning labels. Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment. Untrained personnel can perform the basic maintenance functions of replacing filters. All other operations should be performed by trained service personnel. When working on airconditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. GENERAL The Builder s Box Media Air Cleaner is designed to remove atmospheric and household dust, pollen, mold spores, bacteria, fungi, insecticide dust, animal dander, coal dust, mites, cooking smoke and grease, tobacco smoke, and other particles down to 0.3 micron (1/84,000 in.) Airborne pollutants are carried through the return air ducts of the heating/cooling system to the media air cleaner. The particles are captured by the filter. The media air cleaner can be easily upgraded to an electronic air cleaner for additional air filtration. Additional clearance above the media air cleaner is required for electronic air cleaner upgrade. Regular maintenance (replacement of filters) is required by the home owner. COMPONENTS See Fig. 1 for a description of the media air cleaner. See Table 1 for media air cleaner specifications. Cabinet The cabinet is constructed of heavy gage galvanized steel. Holes are provided in the cabinet for easy mounting in the ductwork or air-handling equipment. See Fig. 2 for cabinet dimensions. Filter The filter is constructed of polyolefin fibers that will not shred or absorb moisture. The unique design of the filter includes a structured density gradient with a polarized charge for higher initial and sustained efficiency. The filter media is supported by an open steel mesh and enclosed by a high strength, beverage board. The filters have an Underwriters Laboratories Class 2 rating. The efficiency of the filter is based on ASHRAE (American Society of Heating, Refrigeration and Air Conditioning Engineers) Standard 52.2P. The maximum velocity is 500 ft/min. An arrow indicates direction of airflow. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION 3/01 LITERATURE NUMBER AC-1SI PRINTED IN U.S.A. CATALOG NUMBER 570-617

Table 2 Media Air Cleaner Pressure Drop (in. wg) PLASTIC KNOB Table 1 Specifications PART NUMBER P102-BB14A P102-BB20 House Size Area Airflow Duct Size Fig. 1 Media Air Cleaner < 3000 ft 2 < 278.70 m 2 > 3000 ft 2 > 278.70 m 2 up to 1400 CFM up to 2379 m 3 /hr 16 x 25 in. 405 x 635 mm up to 2000 CFM up to 3398 m 3 /hr 20 x 25 in. 510 x 635 mm INSTALLATION Location The media air cleaner must be installed in the return air duct, as close to the blower compartment as possible. This location provides the most even airflow across the filter and allows the media air cleaner to keep the system motor and blower clean. See Fig. 3. When choosing location, there must be adequate room to remove filters. NOTE: Be sure to notify home owner not to install any device within 3 ft from the side of the media air cleaner after installation is complete. Regular servicing of the media air cleaner is required. A 3 ft clearance is required to remove filters for maintenance or replacement. IMPORTANT: The media air cleaner will cause more of a restriction of your heating or cooling system than a regular furnace filter due to its increased efficiency. As the filter collects contaminants, the pressure drop increases. The media air cleaner is not recommended in systems where pressure drop is critical. See Table 2 for pressure drop information. PART NUMBER CFM PRESSURE DROP (in. wg) P102-BB14A P102-BB20 700 1400 1000 2000 0.077 0.26 0.079 0.26 INSTALLATION LOCATION WITH HUMIDIFIER If a separate humidifier is purchased, it should be installed in the furnace warm air duct. However, a humidifier may be installed in the return air duct without causing problems to the media air cleaner. Care must be taken to ensure that the humidifier does not leak, as this may cause damage to the media air cleaner and mineral deposits on the filter. An atomizing-type humidifier should only be installed downstream of the media air cleaner. If the atomizing-type humidifier is installed upstream, high humidity, salts, and minerals may damage the filter and cause service problems. If the atomizing-type humidifier must be installed upstream, the atomizing-type humidifier must be installed as far from the media air cleaner as possible. INSTALLATION LOCATION WITH AIR CONDI- TIONER Whenever possible, the media air cleaner should be installed upstream of the cooling coil. This location will clean the air before it reaches the evaporator coil. Media Air Cleaner Installation Perform the following to install the media air cleaner. 1. Remove the existing furnace filter. Thoroughly clean the blower compartment and ductwork where the media air cleaner is to be installed. 2. Remove access door by unscrewing plastic knob. Slide the filter out of the cabinet. 3. Place cabinet in ductwork. Holes are provided to attach cabinet to ductwork or equipment. If the adjoining ductwork is flanged, install the screws so that the screw heads are inside the cabinet. This will help prevent damage to filters during removal for cleaning. When the air duct does not fit the media air cleaner opening, a gradual transition is recommended to reduce air turbulence through the media air cleaner and to increase its efficiency. There should not be more than 20 degrees of expansion used on each side of the transition fitting. Do not reduce ductwork to a smaller media air cleaner or it will increase the velocity of airflow. 4. If the media air cleaner is installed adjacent to an elbow or angel fitting, turning vanes are recommended to improve air distribution across the filter. 5. After media air cleaner has been secured, seal seams airtight with duct tape or caulking to prevent dust from entering the system. 6. Replace filter. Make sure arrow on filter is pointing towards the fan. Replace the access door. 2

D C C A AIR FLOW LEFT TO RIGHT OR RIGHT TO LEFT ACCESS DOOR C B 7 1/2" UNIT A B C D P102-BB14A P102-BB20 17 1 /16 (435) 22 (560) 26 (660) 26 (660) Fig. 2 Dimensions 1 (25) 1 1 /4 (30) 2 1 /8 (55) 2 3 /8 (60) RETURN AIR RETURN AIR RETURN AIR RETURN AIR MEDIA AIR CLEANER MEDIA AIR CLEANER NOTE: Provide a 3 ft (.914 m) clearance for filter removal. Fig. 3 Media Air Cleaner Installation Location 3

OPERATION For maximum performance of the media air cleaner, these steps should be followed: run your heating/cooling system fan continuously remove furniture or carpets which block return air grilles throughout your house, so that air moves freely to the furnace check for proper operation of the blower fan on the furnace ensure that the filter is not clogged. After installation of the media air cleaner, you may notice some white dust on table tops and shelves. Most heavy particles (such as lint) settle quickly and do not get filtered through the media air cleaner. To reduce lint and dust, use continuous fan operation and keep return vents unrestricted to create an efficient airflow. MAINTENANCE It is very important that the scheduled maintenance be done by the home owner. If the filter is not changed on a regular basis, the media air cleaner will not operate effectively. Filter Replacement The filter will need to be replaced once or twice a year, depending on the amount of contaminants in the air. See Table 2. If the filter becomes clogged, airflow through the system may be restricted. This may cause service problems with the furnace or air conditioner. To replace the filter: 1. Turn off furnace fan. 2. Open media air cleaner access door by unscrewing plastic knob. 3. Remove filter from cabinet and discard. 4. Install new filter. Make sure arrow points toward the furnace fan. 5. Replace access door. 6. Turn on furnace fan. Table 2 Replacement Filters PART NUMBER REPLACEMENT FILTER PART NO. FILTER SIZE (in.) P102-BB14A P102-1625BB 15 3 /8 x 25 1 /2 x 5 1 /4 P102-BB20 P102-2025BB 20 1 / 4 x 25 3 / 8 x 5 1 / 4 Make sure to turn furnace off before performing any maintenance or removing air components. 4

MEDIA AIR CLEANER LIMITED ONE-YEAR WARRANTY LIMITED ONE-YEAR WARRANTY This CARRIER CORPORATION product is warranted to be free from defects in material and workmanship under normal use and maintenance for one year. The warranty does not apply to replacement of the disposable media filter, which will need to be replaced once or twice a year depending on usage. A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through a qualified servicing CARRIER CORPORATION dealer or service PROVIDED the defective part is returned to our distributor. THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE, or other costs incurred for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement parts. SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer. LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORK- ING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY. CARRIER WILL NOT BE REPONSIBLE FOR: 1. Normal maintenance as outlined in the installation instructions including replacement of media filters. 2. Damage or repairs required as a consequence of faulty installation or application by others. 3. Damage or repair needed as a consequence of any misapplication, abuse, improper servicing, unauthorized alteration or improper operations 4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond the control of CARRIER CORPORATION. 5. Parts not supplied or designated by CARRIER CORPORATION. 6. CARRIER CORPORATION products installed outside the continental U.S.A., Alaska, Hawaii and Canada. 7. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. Model No. Date of Installation Name of Owner Unit Serial No. Installed by Address of Installation Replacement Components Division Carrier Corporation Syracuse, New York 5

Your Assurance of Quality ALL Totaline products are backed with a one-year warranty by Carrier Corporation, the world s largest manufacturer of air conditioning, heating, and refrigeration products. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION 3/01 LITERATURE NUMBER AC-1SI PRINTED IN U.S.A. CATALOG NO. 570-617