Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Similar documents
Analog Room Pressure Monitor RPC Series

Instruction Manual Model A

Software Version 2.01 LEVEL MONITOR MODEL 220

Beck. The differential pressure transmitter for air

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Temperature Controllers

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series DH3 Digihelic Differential Pressure Controller.

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Pump-Up Controller MODEL 4062

Table of Contents. Protective Relays

Series DH3 Digihelic Differential Pressure Controller

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Construction Electrical

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Sub psi SPECIFICATIONS

Pump-Down Controller MODEL 4052

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

CLEANROOM MONITOR CR3A Network - Installation Instructions

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

APM110 LOW AIR VELOCITY ALARM

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

86BSD Digital Output

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

86BSD Digital Output

Ramsey Motion Monitoring Systems

4 & 8-POINT ANNUNCIATORS Instruction Manual

/8 DIN Level Indicator

IS Series Pressure Sensing Switches

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Standard SPECIFICATIONS FEATURES APPLICATIONS

CP CP

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

NT DUAL CHANNEL DISPLAY. User Guide

Oxygen (O2) Single-Point Gas Detection System

Free Chlorine Measuring System

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

USER S MANUAL INTERSYSTEM PRESSURE TRANDUCER TYPE PM-22

Nov 08 PRODUCT SPECIFICATION SHEET

Specifications - Installation and Operating Instructions

Duct and Rough Service Carbon Monoxide Sensor

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

TK-1801, TK-1811 TK-1801, TKR-1811

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Model 1062 Environment Monitor

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

UDC 700 Universal Digital Controllers and Indicator Specifications

Model OEM-2 INSTRUCTIONS FOR USE

ESSEX ENGINEERING CORPORATION

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Series 5000 Hydrazine Analyzer Model 60002

86BSD Digital Output

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

ACL TC 200 TEMPERATURE CONTROLLER

DP86 Constant Voltage with Fitting

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

ECHOLINE LOW PRESSURE MONITOR. Prevents Unwanted Shutdown Time and Space Saving UL Recognized

Pioneer-R16 Gas Monitor Operator s Manual

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Operating Instructions tico Temperature Indicator

I/A Series 716C 1/16 DIN Temperature Controller

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

vibration switch

Druck DPI 705/DPI 705 IS Series

IntelliPack : 800 Series

DE20 INSTRUCTION MANUAL

Accuracy by Design Products for the HVAC Professional

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Series A3 and A4 Differential Pressure Controller

Interactive Catalog Replaces Catalog Pages

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Two-Channel Gas Controller

02/11/2015

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Carbon Monoxide Transmitter

Product Manual SZ1144

Mobrey MCU900 Series Universal Control Unit

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Transcription:

GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines in one enclosure a low pressure transducer, a digital display, and up to two alarms (see Figure 1). A 4 to 20 ma output is also available as an option. The Modus Model DA controller is typically used for the monitoring of clean room pressures, duct static and velocity pressures; as well as filter differential, draft, fume hood, and other low pressure applications. The pressure sensing element is a differential capacitance cell for pressure measurements ranging from 0.1 in to 5.0 in (2.5 mm to 127 mm) of water (25 Pa to 1.0 kpa), or a piezoresistive (silicon) sensor for pressures from 5 in (127 mm) of water to 30 PSI (1.0 kpa to 200 kpa). The display section has three 1/2 digits with bright, easy to read LEDs. The display is factory-calibrated to read in engineering units. The alarm section is offered with one or two alarms. Each alarm may be ordered with a relay or transistor output. Each setpoint is displayed by pressing a button on the front panel and its setting is changed by means of a multiturn potentiometer also accessible on the front panel. Figure 2 shows a typical deadband diagram for an alarm energizing on falling pressure. When the momentary push button is pressed, the reading on the display is the position of the midpoint of the deadband. When the potentiometer is turned all the way counterclockwise, the lowest reading appearing on the display is half the deadband. Barb fittings and pluggable terminals with screw clamps are provided at the rear for quick and simple field connections. Hi Lo transducer Setpoints 1 2 Alarms Outputs 1 2 g Power VAC, In Figure 1 Block Diagram Power supply 1.8.8.8 display

Model DA Specifications 3.93 in (99.8 mm) On Output state *=Deadband 1* 2 1* 2 1* 2 Off 0 Minimum setpoint Setpoint Screw clamp (2 places) Figure 2 Deadband Diagram 0.30 in (7.6 mm) General Accuracy of Reading Standard ±1% of span one digit (including non-linearity and hysteresis) 3.78 in (96 mm) Top View Setpoint Accuracy ±0.2% of span one digit (including repeatability) Modus Inches of water 3 2 1 Setpoint Power Requirements 21 to 32 VAC, 50/60 Hz, 105 to 135 VAC, 50/60 Hz or 210 to 265 VAC, 50/60 Hz Power Consumption 2.5 VA Electrical Connections Non-interchangeable power and alarm plugs with #4-40 screw clamps; wire range is 14 to 22 AWG Warmup Time Five minutes to rated accuracy Alarm receptacle (plug not shown) 1 2 3 4 5 6 7 8 9 Alarm1 Front View J3 A Alarm2 J1 B AC Power Rear View 5.72 in (145 mm) 5.28 in (134 mm) 0.25 in (6 mm) maximum panel thickness HI LO 0.19 in (4.75 mm) OD pressure fittings AC power receptacle (plug not shown) 1.89 in (48 mm) 1.67 in (42.5 mm) Side View 3.62 in (92 mm) / 3.65 in (92.8 mm) Plug with #4-40 screw clamp wire range: 14-22 AWG 1.77 in (45 mm) / 1.8 in (45.6 mm) Panel cutout (per DIN standard 43700) Modus Model DA dimensions

Transmitter Measures differential, gage pressure or vacuum Medium Air or inert gases Standard Ranges See table A for English units and metric units Maximum Safe Momentary Overpressure See table A Zero and Span Adjustments 15-turn potentiometers accessible behind red front filter Port Connections 3/16 in (4.75 mm) diameter suitable for 1/8 in or 5/32 in ID Tygon or polyurethane tubing; 1/4 in OD polyethylene tubing. Air filter at both ports Display Display Three 1/2 digits, seven segments, orange-red LEDs, 0.56 in (14.2 mm) high, decimal point factoryprogrammable to four positions (1.8.8.8) Conversion Rate Three readings/second Polarity Automatic, no positive sign, negative sign Overrange Indication Beyond 1999 display shows 1 Alarms Number of Alarms One or two alarms Setpoint Adjustment 15-turn potentiometer accessible through hole in front filter Setpoint Display By pressing momentary push button in front of controller Deadband Factory set at 5% of range to prevent output chatter in most applications Output Each alarm is available with either: A) SPDT (One form C) electromechanical relay; contacts rated at 5 A 30 VDC 120 VAC, or 4 A at 240 VAC resistive Contact material is gold overlay Isolation between contacts and coil is 2000 VAC one minute B) Transistor (NPN with open collector) rated at: 40 VDC off-state voltage 120 ma DC on-state current when using an external power supply 40 ma per alarm when using the internal 5 VDC supply (consult factory for higher currents) 0.4 V saturation voltage at 100 ma Internal diode to absorb transients when the internal 5 VDC supply is connected to inductive loads Zero and Span Adjustments 15-turn potentiometers accessible behind red front filter

Environmental Operating Temperature 32 F to 125 F (0 C to 52 C) Storage Temperature -40 F to 185 F (-40 C to 85 C) Relative Humidity 0 to 90% non-condensing Effect of Temperature ±0.03%/ F reading (±0.05%/ C reading), ±0.005%/ F (±0.01%/ C) setpoint Physical Dimensions 1/8 DIN case (see drawing) Case Material Glass-reinforced NORYL rated UL94V-1 Weight 1.0 lb (454 g) Offset If the controller must operate when a reversal of pressure occurs, then an offset must be specified. To order a controller with offset zero, estimate the maximum positive pressure excursion needed and select the appropriate pressure range from Table A. Then estimate the maximum negative pressure excursion. If it is about equal to the positive excursion, specify B offset. If the negative excursion is less than half of the positive excursion, specify an A offset. Alarm Outputs R Electromechanical relay T Transistor, NPN with open collector (specify if external power supply is used) The above alarms can be configured at the factory to energize on rising or falling pressure. To specify the logic, add the following letter after the alarm type: R Energizing on rising pressure F Energizing on falling pressure For example: Alarm one is selected with a transistor energized on falling pressure, the ordering code is TF. Alarm two is a relay energized on rising pressure, the code would be TR.

Wiring Diagrams Standard Ranges English Units Code (1) Range Displayed Resolution Maximum Units (2) Overpressure 01E 0 to 0.1 inh 2 0.100 0.001 in 5 in 02E 0 to 0.2 inh 2 0.200 0.001 in 5 in 04E 0 to 0.5 inh 2 0.500 0.001 in 5 in 05E 0 to 1.0 inh 2 0 1.000 0.001 in 20 in 06E 0 to 2.0 inh 2 0 1.999 0.001 in 20 in 08E 0 to 5.0 inh 2 0 5.00 0.01 in 5 psi 09E 0 to 10.0 inh 2 0 10.00 0.01 in 5 psi 11E 0 to 20.0 inh 2 0 19.99 0.01 in 5 psi 15E 0 to 1 psi 1.000 0.001 in psi 15 psi 16E 0 to 2 psi 1.999 0.001 in psi 15 psi 17E 0 to 3 psi 3.00 0.01 in psi 15 psi 18E 0 to 5 psi 5.00 0.01 in psi 15 psi 19E 0 to 15 psi 15.00 0.01 in psi 30 psi 20E 0 to 30 psi 30.0 0.1 in psi 60 psi **E Contact factory for other pressure ranges, displayed units and resolution Metric Units, Millimeters of Water Code (1) Range Displayed Resolution Maximum Units (2) Overpressure 01M 0 to 2.50 mmh 2 0 2.50 0.01 mm 125 mm 02M 0 to 5.00 5.00 0.01 mm 125 mm 04M 0 to 10.0 10.00 0.01 mm 125 mm 05M 0 to 25.0 25.0 0.1 mm 500 mm 06M 0 to 50.0 50.0 0.1 mm 500 mm 08M 0 to 100 100.0 0.1 mm 3.5 m 09M 0 to 250 250 1.0 mm 3.5 m 11M 0 to 500 500 1.0 mm 3.5 m 13M 0 to 1.00 m 1.000.001 m 10 m 14M 0 to 2.50 m 2.50.01 m 10 m 15M 0 to 5.00 m 5.00.01 m 10 m 16M 0 to 10.0 m 10.00.01 m 20 m 17M 0 to 20.0 m 19.99.01 m 40 m **M Contact factory for other pressure ranges, displayed units and resolution Metric Units, Pascal Code (1) Range Displayed Resolution Maximum Units (2) Overpressure 01P 0 to 25 Pa 250 0.1 Pa 1.25 kpa 02P 0 to 50 Pa 50.0 0.1 Pa 1.25 kpa 04P 0 to 100 Pa 100.0 0.1 Pa 1.25 kpa 05P 0 to 250 Pa 250 1 Pa 5.0 kpa 06P 0 to 500 Pa 500 1 Pa 5.0 kpa 08P 0 to 1.0 kpa 1.000 1 Pa 35 kpa 09P 0 to 2.5 kpa 2.50 10 Pa 35 kpa 11P 0 to 5.0 kpa 5.00 10 Pa 35 kpa 13P 0 to 10 kpa 10.00 10 Pa 100 kpa 14P 0 to 25 kpa 25.0 100 Pa 100 kpa 15P 0 to 50 kpa 50.0 100 Pa 100 kpa 16P 0 to 100 kpa 100.0 100 Pa 200 kpa 17P 0 to 200 kpa 199.9 100 Pa 400 kpa **P Contact factory for other pressure ranges, displayed units and resolution (1) Use this code when ordering. (2) This column shows the number of digits that are displayed and the position of the decimal point. Controller Relay J3, Connector Figure 3 Relay output Shows the internal wiring of the electromechanical relay. This type of output will switch small loads such as pilot lights or audible alarms. Also, the gold contacts offer a reliable output when a contact closure must be sensed and the current is very low. Transistor +5 VDC Controller Diode J3, Connector 1 (4) Terminals 2 (5) 3 (6) C NO NC 1 (4) Terminals 2 (5) 3 (6) Solid-state relay Figure 4 Transistor output, internal power supply A wiring diagram of the transistor output connected to a solid-state relay. The input voltage range of the relay is 3 to 32 VDC. Power is supplied by the internal 5 VDC supply of the controller. If an inductive load is connected, the internal diode will protect the transistor against transients.

Transistor Controller +5 VDC J3, Connector Diode* 1 (4) Terminals 2 (5) 3 (6) Load Power supply 40 VDC maximum *Diode required with inductive loads. Figure 5 Transistor output, external power supply Shows the transistor controlling a load powered by an external 12 or 24 VDC supply. An external diode or other means of limiting transients to 40 Volts must be added if the load is inductive. The current must not exceed 120 ma. Ordering Information Record selected option in blank indicated at bottom of form. DA Code Power Supply 1 120 VAC 2 240 VAC 3 24 VAC Code Input X See Standard Range Tables Code Offset 0 No offset A 1/4 offset B 1/2 offset Code Alarm Output R Electro mechanical T Transistor Code Energize (E) F Falling pressure R Rising pressure Code Option 420 4 to 20 ma output DA - - - - - - Typical model number.

g www.gesensinginspection.com 920-295B 2008 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.