Explosion-proof ATEX Spark Detector SCL-01

Similar documents
EDS - SPARK DETECTORS - GENERAL NOTES

FLV 40 UV Flame Detector

FLV45 FLV45A FLV45A-AL

Snifter ATEX22 VERSION. User Manual. Distributor

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

Optical Beam Smoke Detector RK90R - RK90RS

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

OilSET-1000 (12 VDC)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

GL-CO-RFG Channel Gas Leak Alarm System

Detecting Sparks, Extinguishing Sparks!

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

USE AND INSTALLATION HANDBOOK

AO Annunciator Module

SET Installation and Operating Instructions. Level switch for one sensor

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

USE AND INSTALLATION HANDBOOK

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

SET-2000 Oil/Sludge 12 VDC

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

MANUAL Overflow sensor NVF-104/34-PF

03.03.mmm REV.2 09/01

Movement Detector GJD 300

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Dräger Flame 2100 Flame Detection

Snifter. User Manual. Distributor

Rotameter series 250 metal tube variable area flowmeter

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

INSTRUCTION MANUAL (ATEX / IECEx)

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Gate Operator. Modfications

VADA - Rain2Main Automatic Rainwater Controller

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

BGH Series Hot Surface Ignition Control

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Sitron s CF Line of Flow Switch Monitors

SET-2000 Hi Level/Oil

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

INTRODUCTION / TABLE OF CONTENTS

Centro-Matic Automated Lubrication Systems System Controls

OPTISENS TUR 2000 Technical Datasheet

Interrupted Ignition Series Oil Primary Control

Dräger Flame 2500 (IR3) Flame Detection

Operating Instructions

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

UV Flame Supervision System

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Dual Column Dehydrating Breather Manual

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

ATM Lighting sp. z o.o

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Dräger Flame 2700 (Multi-IR) Flame Detection

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

WET ALARM VALVE CPF FIRE V.A.U. 3 V.A.U. 4

Talentum Flame Detector User Guide

ATM Lighting sp. z o.o

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

RK100B - RK200B RK100BS - RK200BS

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Dräger Flame 2500 Flame Detection

FLOW HEATER 32E X 2R IMPORTANT GENERAL INFORMATION: SPECIFICATION. Instruction Manual. Article number: 045a-105 Electric heating capacity:

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

Dräger REGARD -1 Control System

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

D-Tect 2 GJD300 Quad PIR Movement Detector

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

Power Supply Display Module PSDM. Installation and Operation Manual

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

Installation & Maintenance Manual

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Dräger PIR 3000 Detection of flammable gases and vapours

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

M770 ph Controller Owner s Manual

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Transcription:

Explosion-proof ATEX Spark Detector SCL-01 TECHNICAL MANUAL EDS srl - V. Ca' Nova Zampieri 6-37057 S. G. Lupatoto - VERONA - Tel. +39045547529 - Fax +390458750065 Email: eds@eds.eu - Web: www.eds.eu 1

SPARK DETECTOR SCL01 The SCL-01 is a spark detector suitable for the detection of very fast sparks that can be transported by pipelines of silos or warehouses for the storage of flammable materials such as sawdust, cotton yarn, cereal powders, metal powders, etc.. The possibility of detection in an extremely short time of this detector can prevent the development of a fire with serious consequences. The SCL-01 detector is explosion proof ATEX Exd. It must be installed according to the recent legislation on the installation of electrical equipment in potentially explosive atmospheres. 1 - INSTRUCTIONS 1.1 - The detector can be used as standalone or (recommended) with the EV521 or SCU-04 control panels expecially designed for this application. They are equipped with internal stabilized power supply, test circuits, timers and relay outputs. Moreover, these control panels feature very fast circuits so that the response time of the system results to be very short. 1.2 - Drill a hole of 130 mm (Fig. 7) diameter on the surface of the pipe that must be surveilled. 1.3 - Install the equipment on the outer surface of the pipe using the black O ring, the two fixing brackets and the bolts supplied according to the diagram shown in fig.6 and to the drill chart of fig.7. The detector must see inside the pipe and the surveilled area has not to be subject to variations of ambient light. 1.4 - We suggest not change the distance between the front of the detector and the outer surface of the pipe. The viewing window of the detector, must not extend too far inside the pipe, because this could create obstacles to the transport of the materials flowing in the pipe or start an encrustation that can obscure the vision window. 1.5 - Connect the equipment as shown in the schematic diagram in Fig. 3 or according the technical instructions of control panel EV521 or SCU-04 if present. 1.6 - The detector can be powered by AC or DC voltage 12/24V. To obtain a greater immunity to electrical noise power should always be supplied by a stabilized power supply with backup battery. If you choose the voltage of 24V DC or AC, remove the selection jumper JP9 (Fig. 3). 1.7 - The detector is equipped with a relay output. Terminals are available on the terminal board (terminals 1-2-3). The relay can be operated normally attracted or normally not attracted. For the selection of operating mode use the jumper JP2 : 1-2 position - relay normally attracted 2-3 position - relay normally not attracted The indication of the terminals on the terminal board refers to the normally not attracted relay operation. 1.8 - The detector has the possibility to be tested remotely. By connecting an external switch (NO contact) to terminal 6 (TEST) and terminal 5 (GROUND) a periodic test of the detector can be performed. When the TEST but is remotely pressed, a real spark is passing through the pipe is simulated, and so the detector reacts activating its output relay. 1.9 - The detector has two internal settings (Figure 2) 2

- sensitivity level adjustment - adjustment of the duration of the time of activation of the output relay (using the jumpers JP3-4-5-6-7) They must be adjusted to achieve optimum performance 1.10 - The detector is equipped with internal microprocessor which not only provides the operation and check of electronics, but also provides the check of the status of internal components. In case of fault an output signal (FAULT) is generated. A +5V is generated on terminal 4 and it can be used for a remote indication of a fault. The maximum generated current is 10mA. 1.11 - The detector has a field of view of 90 (solid angle) and is suitable for pipes with a diameter up to 50 cm. If the diameter is larger, or if the pipe section is square, rectangular, etc.. to avoid dead zones outside the field of view of the detector and have ensure detection, we recommend using two detectors installed diametrically opposite on the pipes surfaces. 1.12 - The output relay can be conveniently used to actuate a solenoid valve that feeds a sprinkler spraying nozzle to perform automatic extinguishing of the spark in the pipeline. This nozzle therefore sprinkle water for a time set by the setting of jumpers JP3-7 (adjustable between 0-10 seconds). We recommend a time of about 5 seconds. 1.13 - When you want to be sure of the success of extinguishing or in important facilities, where security must be at the highest level, we suggest to install a second detector (or detectors couple) at a certain distance from the first one, in order to have a second check of extinguishing and if necessary a second try. If the spark has already been extinguished the second detector will remain inactive. Otherwise it react and its output relay contact can be exploited to: - activate a second sprinkler spraying nozzle for a second extinguishing attempt - activate a door shutter to prevent the spark from being introduced into the silo - activate a suitable audible warning 2 - OPERATION VERIFICATION 2.1 - to verify the operation of the detector after installation and the adjustments set out in chapter 1, you must: - power on to the detector - wait 1 minute to allow the microprocessor to operate the various settings - press the TEST button remotely connected to terminals 6-5. If you use the EV521 control panel, press the TEST button present on the front of the unit or press the remote button connected to the 17-18 terminals of the control panel. If you are not using the test button to check the operation of the detector it s necessary to cause a real spark in his field of view. This must be done only after taking adequate security measures 3 - SYSTEM OPERATION 3.1 - With reference to Fig. 5 relating to a system with two detectors, if a spark passed in the viewing field of the first detector, the detector SCL-01 enters in alarm condition, and its output relay is energized instantaneously and remains energized for an time adjustable between 0-10 seconds (JP3-7). The output contacts of this relay will be used to operate the electrovalve VL1, which will cause the intervention of the SS1 spraying nozzle for a first extinguishing attempt. 3.2 - If the spark has been extinguished, the system returns to the initial state of normal operation. Otherwise the spark, continuing his flowing, will enter in the viewing field of the second detector SCL-01. This will activate its output relay. The realy contacts will operate the electrovalve VL2 causing the activation of SS2 nozzle SS2 for a second extinguishing attempt. shutdown 4 - RESPONSE TIMES 4.1 - The time to be taken into account in the design of a spark detection system are as follows: T1 - operating time of the spark detector SCL-01 T2 - operating time of the relay output of the spark detector T3 - signal processing time and operating time of the relay output of EV521 T4 - response time of VL electrovalve T5 - time of water filling of the part of the pipe between the electrovalve and the SS nozzle and time of formation of the cone of extinguishing water 3

If the system does not use the EV521 control panel, signal processing time and response time of the relay output of EV521 (T3) should not be counted. Usual values are as follows: T1-3-10 ms T2-12/15 ms T3-15 ms T4-10 ms T5 - depends on the length of the pipe, on the pipe section and especially on the water pressure 4.2 - For the calculations we can consider the time T1-T4 in 60 ms max. Time T5 must be added to this sum. This time depends on the pressure of the water, on the section of the pipe and the nozzle used. With a nozzle SP34F22 and pressure of 3-4 bar, a water speed of approximately 4-6 m / s is obtained. Therefore, if the section of tube between the electrovalve and the nozzle is 1 m, the transit time is around 0.2 s. Then summing the times T1-T5 leads to 0.26 s. This time is the response time of the system. 5 - NOZZLE POSITIONING 5.1 - The spraying nozzle has the function to extinguish the spark. Its position must be calculated as a function of times indicated in the previous chapter, and the speed of the fluid being transported within the pipe. For a calculation of average value using the simple formula derived from physics: S = vt where : S = distance traveled in meters v = speed of the fluid inside the pipe in m / s t = response time of the security system The speed of the fluid must be measured on site. Typically you will get speeds of about : timber industry 20-30 m / s textile industry: 10-20 m / s For other applications, you need a measurement. Therefore, knowing the 3 fundamental parameters of the formula, the calculation is very simple. 5.2 - Example: fluid velocity: 25 m / s response time: 0.25 s is obtained: S = 25 x 0.25 = 6.25 m (distance traveled by the spark) In this case, therefore, the spraying nozzle should be positioned at more than 6.25 m (7-8 m) from the point where the spark detector is installed, so that the spark is extinguished by the water cone. For designers is shown below the graph velocity of the fluid as a function of the distance (fig. 1). To decrease the response time of the system, as time T5 has considerable influence, you must use: an higher water pressure (4-6 bar) a pipe with a larger cross-section a nozzle with higher flow rate (32-63 l / min) To increase the water pressure is recommended the use of an autoclave of 20-30 liters with pressure tank and pump. If the length of the pipe is considerable, to decrease the pressure drop due to the loss of load, it is recommended the use of a tank with the function of flying-wheel function and unidirectional valve. 6 - MAINTENANCE 6.1 - The spark detector must be periodically cleaned. The detector must be removed from its fixing brackets and its optical viewing window should be cleaned with a cloth moistened with water and traces of soap. Do not use alcohol and any kind of solvent. This operation must be carried out periodically according to the type of fluid. The fluid flowing inside the pipe usually keeps the viewing window clean because of rubbing. The normal layer of dust that is deposited on the vision window, does not influence its operation because the infrared radiation passes through the layer. 6.2 - Periodically verify the mechanical parts of the system. If you use a self-closing damper or a drainage system of the fluid, it is necessary to periodically check operation and lubricate the moving parts. 4

6.3 - Periodically check the operation and thightness of the electrovalves. A defect in the seal can result in flooding of the pipeline and can cause damage. It would be good to install a tap and a filter to trap impurities that may affect the electrovalve upstream the valve. It would be also good to provide some elements of water discharge somewhere along the pipeline. 6.4 - If the installation is done outdoor the problem of winter frost must be taken in account in the system. The water pipe must be caulked and the elements of the extinguishing system (electrovalve, pressure gauge) musto be insulated from freezing. If these precautions are not enough, we suggest to use an heating cable coupled to a thermostat to ensure a temperature above 0 degrees. 6.5 - If the system is idle for long periods it is good to empty the water supply pipe. 6.6 - Check the electrical connections (terminals, connectors, etc..) Of the various elements of the plant. In particular, check the grounding of all metal parts. 7 - TECHNICAL DATA power supply : 24 V AC-DC power consumption: 20 ma - 50 ma (alarm) internal voltage stabilizer electronics and microprocessor control circuit protectors against electric shock viewing angle: 90 response time: 3-15 ms max distance. of detection : about 50 cm (size of the spark approximately 1 mm T = 800 C) alarm LED indicator sensitivity adjustment: half trimmer alarm duration adjustment : 0 to 10 sec relay operation normally attracted or not attracted relay output: 6A/24 V container: in light alloy entrance cables: 3/4" ISO7/1 Protection: EX-d certifications: CESI ATEX dimensions: 180x150x130 mm weight: 1.8 Kg 8 - STANDARD REFERENCES The equipment has been designed to meet the specifications of the following standards: CEI 31-30 CEI 31-33 CEI 31-35 IEC 31-35A CEI EN 60079-0 CEI EN 60079-1 9 - WARNING 9.1 - The SCL01 spark detectors for areas with explosive atmospheres, are specifically designed to meet the requirements of official standards for environments with danger of explosion. Improper use, wrong connection, removing any protections, inadequate inspection and maintenance or only a marginal modification, may compromise the safety and reliability of the unit, causing serious damage to people and/or things. Follow scrupulously the rules relating to the connections and the use of electrical equipment in areas with potentially explosive atmospheres. The devices must be handled, installed, put into service, operated, maintained and repaired by qualified and experienced personnel with a thorough knowledge of these regulations and in the absence of an explosive atmosphere. Please follow all instructions, instructions of the installation, current safety laws and all applicable laws concerning correct installation. Any additional components in the system in special execution or with other versions may differ in detail from those described and may require additional information. 5

30 distance distanza [m] System response time 0.25 sec tempo di risposta del sistema 0,25s 25 20 15 10 Suggested area zona consigliata 5 0 non usare velocità del fluido 0 5 10 15 20 25 30 [m/s] fig.1 do not use fluid speed fig.1 6

A ALARM LED LED ALLARME external view SENSITIVITY SENSIBILITA' + - TIME ATTRACTION TEMPO ATTRAZIONE A Fig. 2 Attraction time for relay output. Selection is done inserting the corresponding jumper (one only) JP3-1 sec JP4-2 sec JP5-5 sec JP6-10 sec JP7 - the relay is attracted undefinitely to store the event. To reset you must power-off the detector for a few seconds components side view RELAY RELE' 123 V+ V- TEST GROUND FAULT NA NC COM valtage selection cambiotensione push button pulsante 1K LED ralay mode selection settaggio rele' fig.3 7

Fig. 3 -Example of a system with one SCL01 Pipe Water feed pipe SCL01 Spark Detector Spraying Nozzle Fig. 4 - Example of system with 2 SCL01 electrovalve pressure gauge electrovalve pressure gauge water supply pipe nozzle water supply pipe nozzle SCL01 Detector SCL01 Detector automatic shutter Silo 8

SCL01 SPARK DETECTOR MECHANIC MOUNTING SCL-01 detector rivelatore SCL-01 washer rondella threaded rod M8 barra filettata M8 fig.6 DS1207 nut M8 dado M8 seal guarnizione washer rondella pipe tubazione 80.0 TEMPLATE Ø130.0 160.0 fig.7 9

SCL01 SPARK DETECTOR DIMENTIONS fig.8 The information contained in this document have been carefully checked and are reliable. By the way EDS company is not responsable in any way for possible inaccurancies or errors and it reserves the right to perform changes in any part of this document and/or product, to improve the quality, reliability or the design. Date:02/04/2012 Filename: SCL01_inst-en_0412 Release : EV-586AB/ SW ver. 1.0 Copyright 2002-2008 Electronic Detection Systems. All rights reserved 10

TECHNICAL INFORMATION EDS - TECHNICAL INFORMATION Explosion Proof Spark Detector SCL-01 ADVANTAGES signalling quickness and precision remote fuctioning test available solid metal box easy installation easy maintenance APPLICATIONS wood industry: sawdust shavings textile industry: cotton all other fibres food industry: cereals The EDS SCL01 Spark Detector is an electronic device suited to detect spark in pipes and channels that transport varoius types of combustible materials headed to a storing silo. The execution is explosion proof EX-d IIC-T6 - ATEX certified. So the detector is suitable to be installed in classified environments where the installations must be explosion proof. During the transporting phase, a spark, produced in the previous manifacturing stages, can be transported mixed with the materials. If this spark is not detected and neutralized very quickly, once it arrives inside the silo, it can cause a fire or an explosion. So the precise and quick detection of the spark, can be used to prevent great damages and dangers to both people and things and consequently to elevate the security level of the environment. The SCL01 detector is able to reveal sparks that cross its viewing range even if they have a great velocity (up to 100 km/h). The detector is equipped with an optical head sensible to infrared radiation, that has a viewing range of more than 90 degrees (solid angle) and a suitable electronic circuit that provides for amplification and processing of the signal. When the SCL01 detector intercepts a spark it provides the powering of a relay suitable to switch on optical and acoustic alarms. Moreover a fire extinguishing system (splinker head systems) can be activated. If the pipes have a large diameter (over 0,5 m.) several SCL01 detectors can be used to obtain a better security level. If a water spraying automatic extinguishing system is also present,the spark extinguishing can be verified. If the transporting pipe has not a cylindric shape, for example squared or rectangular, it can be necessary to use two opposed detectors, to avoid dead zones external to the viewing range of the detector. The detector's box is made of fusion light alloy with IP65 protection, and so the internal electronics are protected from dust, shocks and from ambient conditions, that can be also corrosive, permitting to use the detector outdoor for a long time without any problem. The detector is supplied with a inox steel fixing stirrup to be easily fixed on the pipes. The maintenance of this detector is very simple and not frequently required. Supplied Materials The standard supply materials include: - 1- SCL-01-1 - SUP-01 - inox steel fixing stirrup For the former function it is suggested to use our EV 521 or SCU04 control unit that has a great using flexibility. 11

TECHNICAL DATA power supply: 12/24 V dc and ac power consumption: 20 ma (no alarm) - 50 ma (alarm) solid viewing angle: 90 gradi max detection distance: about 50 cm sensitivity regulation relay activation time regulation: 1-10 sec terminals to connect a remote working test button alarm led output relay: 6A/24V light alloy metal container cables mounth: 3/4" ISO 7/1 explosion proof execution EX-d IIC T6 - IP66 certifications: CESI 01 and ATEX 092 dimensions: 200x130 mm weight: 2 Kg Installation example with SCL-01 transporting pipe water feed pipe electrovalve pressure meter water cone SCL-01 nozzle Installation example with two SCL-01 shutter SILO 12

TECHNICAL INFORMATIONS EDS - TECHNICAL INFORMATION Accessories for Spark Detection Systems VL-34-24 - electrovalve ELECTROVALVE - NC normaly closed - usefull for water - enclosure: OT - guide pipe: INOX steel - threading: 3/4 - differential pressure: 12 bar - pressure max: 20 bar - water flow: 5 m3/h (83 l/min) - electromagnet: 10 VA - voltage: 24Vca - service: continuous - temperature: -10 + 60 C - protection index: IP65 - connectio: DIN46340 SP - nozzle - material: OT SP14F08-1/4" female - 8 lt/min - full cone 61 degree SASH SHUTTER ELECTROMAGNET PRESSURE SWITCH NOZZLE A 91.0 D 50.0 65.0 50.0 65.0 SP12M16-1/2" male - 16 lt/min - full cone 61 degree SP34F22-3/4" female - 22 lt/min - full cone - 50 degree SP34F32-3/4" female- 32 lt/min - full cone - 100 degree SP34F63-3/4" femmina- 63 lt/m - full cone - 100 degree PRS-14-55 - pressure switch - pressure range: 2-5,5 bar - pressure max: 7 bar - current: 10A - protection index: IP40 - temperature: -35 + 80 C - threading: G 1/4" female EDS 1335 - electromagnet - power supply: 24Vcc - magnetic actractive force: 50 Kg - current: 46 ma - Test push-button - to drive pipeline gravity shutters EDS-SRG-ET pneumatic cylinders: 2 material: zinc plated steel electrovalve voltage: 220Vac, 110Vac, 24V ac, 24Vdc (to point out in the order) pressure work minimum: 6 bar time of closing: 2 sec (diameters 200-480) - 3 sec (500-700) - 4 sec (750-1.000) position (orrizontal/vertical): in any way B C 13