Boiler Start-Up Cycle SYSTEM RETURN

Similar documents
Boiler Start-Up Cycle

COLD WATER START A P P L I C AT I O N S

Proudly assembled in U.S.A

Proudly assembled in U.S.A

INSTALLATION & OPERATING INSTRUCTIONS

Proudly assembled in U.S.A

DIVISION FINNED WATER-TUBE WATER HEATERS

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

FINNED WATER-TUBE POOL HEATERS

Models HD101 thru 2342B

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

DIVISION FINNED WATER-TUBE BOILERS

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

DIVISION FINNED WATER-TUBE BOILERS

Wood Boiler Plumbing Schematics

Less Than.25 Pb Proudly made in the U.S.A

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

FINALLY GET THE FEATURES YOU WANT

Applications and Piping Strategies for Condensing Boilers - Introduction

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Honeywell Water Solutions. Thermostatic Mixing Valves

ProRadiant Controls, Valves and Actuators

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

DIVISION FINNED WATER-TUBE BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

SECTION WATER HEATERS

RAYPAK ILLUSTRATED PARTS LIST

Taco 00 Series Cartridge Circulators

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Get The Edge Over The Competition with The Summit

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

propanel Series Installation Manual

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

97% Thermal Efficiency

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

Hydronic Product & Application Catalog

heat interface units A BOILER WITHOUT A FLAME

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

RAYPAK ILLUSTRATED PARTS LIST

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Allcan TM Installation Manual

This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place for future reference.

User Manual / Care Instructions

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

Automatic Temperature Controller (ATC)

High Capacity Instantaneous Steam Fired Water Heater

Silhouette. Feedwater Heater. Boiler Feedwater

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

MASCOT Quick Setup Guide

High efficiency, cast-iron gas boiler

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

13-1. Temperature Regulator

"Best Practices in Modern Hydronic Heating - THE DETAILS

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

NO ONE PUTS MORE INTO THEIR POOL HEATERS

Welcome To. System Benefits With ECM PUMPS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Series 1140 and 1141 Temperature Regulators

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Thermostatic Radiator Valves (Caleffi)

PUSHING THE LIMITS OF WHAT IS POSSIBLE

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

UHS Heater. How To Guide. HTG-UHS17a. Copyright 2017 Hayward Industries Inc.

RA15/6T & TB Conversion Valve

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Transcription:

COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While Raypak boilers and water heaters can operate without harmful condensation at lower inlet water temperatures than the competition, there are still applications that require reliable protection against harmful condensation caused by frequent, extended, cold water start-ups. Raypak s Cold Water Start protection system utilizes a proportional three-way valve to bypass water from the boiler outlet to the inlet during start-up, when the system return water temperature is below the minimum acceptable level. Boiler Start-Up Cycle BLENDED INLET TEMP STABLE TEMP MIN INLET TEMP SETTING START-UP TEMP TEMPERATURE RETURN RETURN NOW AT OR ABOVE MINIMUM INLET SETTING. BYPASS CLOSED, FULL FLOW TIME Raypak s Cold Water Start system: Continuously monitors and adjusts inlet water temperature to prevent condensation Regulates minimum inlet water temperature during system start-up Activates alarm and/or shuts down boiler if the minimum inlet water temperature is not achieved Eliminates job site set-up with proprietary self-tuning controller and system-matched components Utilizes proportional three-way valve to achieve bypass Allows high-temperature system operation without cycling on high-limit A PPLIC ATIONS Commercial Hydronic Heating Office Buildings Factories/Warehouses Greenhouses Domestic Hot Water Supply Restaurants Weekend Shut-down (e.g. 6-day/week shopping center) Dump Loads 87% Hot Water Supply Boiler Intermittent Industrial Process

COLD WATER RUN For the same reason stated for Cold Water Starts, it is even more important to provide protection against condensation from cold inlet water on systems where the return water temperature to the boiler will always be below the acceptable minimum. Raypak s Cold Water Run system utilizes a variable-speed pump to inject just the right amount of water from the main system loop into the boiler to maintain the optimum inlet temperature. This approach allows the full capacity of the boiler to be utilized to meet the system load, while at the same time continuously maintaining the optimum inlet water temperature to prevent condensation. Boiler Start-Up Cycle MIN INLET TEMP SETTING BLENDED INLET TEMP RETURN START-UP TEMP TEMPERATURE TIME Raypak s Cold Water Run system: Continuously monitors and adjusts inlet water temperature to prevent condensation Regulates minimum inlet water temperature regardless of system temperature Activates alarm and/or shuts down boiler if the minimum inlet water temperature is not achieved Protects boiler from constant low return water temperatures with its proprietary self-tuning controller Utilizes variable-speed injector pump to control boiler loop temperature APPLICATIONS Pool Heating Low-temperature Industrial Process Very Low-temperature Return Water (e.g. convalescent hospital domestic hot water)

COLD WATER START 3-WAY VALVE TO FROM Cold Water Start J-Box Assembly Typical Cold Start Plumbing Pictorial-Not to Scale COLD WATER RUN VARIABLE SPEED INJECTOR TO FROM Cold Water Run J-Box Assembly and Alternate Inverter Typical Cold Run Plumbing Pictorial-Not to Scale

TECHNICAL DATA COLD WATER START TYPICAL PIPING* NOTES: 1. LOCATEUNIONSTOFACILITATESERVICINGOFPLUMBINGSIDE. 2. PLUMBSWINGCHECKVALVEINGRAVITY-CLOSEDPOSITION. 3. PIPEALLRELIEFVALVESTODRAIN,ORASLOCALCODESREQUIRE. 4. BUFFERTANKREQUIREDWHENWATERVOLUMEINLOOPIS NOTADEQUATETOPROVIDESTABLETEMPERATURECON- TROL. CONSULTFACTORYFORTANKSIZING. 5. FLOWMUSTEXCEEDHEATERFLOWATALLTIMES. COLD WATER RUN TYPICAL PIPING* *ITEMSREQUIREDFORCOLDWATERSTARTARESHOWN. OTHERSTANDARDCOMPONENTSHAVEBEENOMITTEDFORCLARITY. NOTES: 1. LOCATEUNIONSTOFACILITATESERVICINGOFPLUMBINGSIDE. 2. PLUMBSWINGCHECKVALVEINGRAVITY-CLOSEDPOSITION. 3. PIPEALLRELIEFVALVESTODRAIN,ORASLOCALCODESREQUIRE. 4. FLOWMUSTEXCEEDHEATERFLOWATALLTIMES. *ITEMSREQUIREDFORCOLDWATERRUN OPERATIONARESHOWN.OTHERSTANDARDCOMPONENTSHAVEBEENOMITTEDFORCLARITY.

TECHNICAL DATA MULTIPLE UNIT COLD WATER START SUGGESTED IN-LINE LOCATION ON MODELS WITHOUT INTEGRAL ALTERNATE LOCATION ON REAR HEADER WHEN APPLICABLE NOTES: 1. PLUMB SWING CHECK VALVE IN GRAVITY-CLOSED POSITION. 2. PIPE ALL RELIEF VALVES TO DRAIN, OR AS LOCAL CODES REQUIRE. 3. LOCATE UNIONS TO FACILITATE SERVICING OF PLUMBING SIDE. 4. BUFFER TANKS MAY BE REQUIRED TO PROVIDE STABLE TEMPERATURE CONTROL ON S WITH VARIABLE FLOW OR LOW WATER VOLUME. CONTACT FACTORY FOR SELECTION CRITERIA 5. NOT TO EXCEED 4 PIPE DIAMETERS. 6. FLOW MUST EXCEED TOTAL MINIMUM FLOW RATE OF S. 6. FLOW MUST EXCEED TOTAL MINIMUM FLOW RATE OF S Total System Load Three-Way Diverting Valve Specifications (MBTUH) Valve Size Cv GPM rp 500-900 2 NPT 57 70 3.5 901-1,800 2-1/2 NPT 74 100 4.2 1,801-3,000 2-1/2 NPT 100 150 5.2 3,001-4,000 4 Flange 152 220 4.8 4,001-6,000 4 Flange 254 330 3.9 6,001-8,000 4 Flange 327 440 4.2 Notes: 1. Maximum of 4 boilers per system. 2. Many variables can impact the proper valve sizing for multiple boilers. This sizing is provided as a guide. When in doubt consult the factory. 3. Multi-unit system ALWAYS shipped loose- Not available mounted. 4. 4 flanges, bolts and gaskets supplied by others. Multi-units with 4 valves are to be used on hydronic heating only. The valve body is cast iron. Catalog No.: 1000.19G Effective: 08-01-12 Replaces: 01-01-12 Raypak Inc., 2151 Eastman Ave., Oxnard, CA 93030 (805) 278-5300 Fax (800) 872-9725