TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Similar documents
TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

TDS 20 R / TDS 30 R / TDS 50 R

TTV 4500 / TTV 4500 HP / TTV 7000

B 400. Operating Manual Humidifier B 400

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

PAC 2600 E OPERATING MANUAL PORTABLE AIR CONDITIONER TRT-BA-PAC2600E-TC-001-EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTK 1500 OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK1500-TC-001-EN

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TDS 100. EN Operating Manual Electrical Fan Heater

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

AW 20 S OPERATING MANUAL AIR WASHER TRT-BA-AW20S-TC-004-EN

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

PAC 2000 E OPERATING MANUAL LOCAL AIR CONDITIONER TRT-BA-PAC2000E-TC EN

PAE 50 OPERATING MANUAL AIR COOLER TRT-BA-PAE50-TC EN

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Cabinet Refrigerators/Freezers Instruction manual

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Stainless Steel Counter Refrigerators Instruction manual

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GB Operating instructions

REMKO ETF 240 Portable Air Dehumidifier

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

High Pressure Washer 130

Compact Pressure Washer 100

REMKO ETF 220 Portable Air Dehumidifier

Trotec PAC FT 2600 Portable air conditioner

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Sip Vacuum Cleaner 1400/35 Wet & Dry

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

REFRIGERAT A OR USE DF1-15 F ridge

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operating Instruction

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Fundamental safety warnings

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Drying Cabinet Installation and Operating Manual

GDDEM10 DEHUMIDIFIER

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Waste water ejection unit

51AKS I S O OWNER S MANUAL

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

MeacoDry ABC Range Dehumidifiers

OPERATING INSTRUCTIONS

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

MADE IN GERMANY INSTRUCTION MANUAL. Air Dehumidifier. Series AD 420 AD 430. AD 420 / Rev. 3

Instructions manual DEHUMID HP50

REMKO AMT 60-E - 90-E Mobile Dehumidifier

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Model 1870F Dehumidifier Installation and Operating Manual

OPERATING INSTRUCTIONS

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Model 1820 Dehumidifier

Refrigerator KE T

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

Chest Freezer Instruction manual

Read these instructions before using and keep them available at all times!

51AKB / 51 AKC OWNER S MANUAL

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Read these instructions before using and keep them available at all times!

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Dehumidifier. Instruction Manual. Model DH-320/A

Tempest TP420/180 Electric Pressure Washer

Operator s manual. Battery charger C 48/ en / 03

PORTABLE AIR CONDITIONER (LOCAL)

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

PORTABLE AIR CONDITIONER (LOCAL)

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

data logger DL200H DL200D DL200L

REMKO AMT 45-E to 115-E

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Meaco 10L small home dehumidifier Instructional Manual

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

20 LITRE DEHUMIDIFIER

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PORTABLE AIR CONDITIONER

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Air always contains a certain amount of water in the form of vapour. This determines the

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

Heavy Duty Pressure Washer 150

Table of Content

PORTABLE DEHUMIDIFIER

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

Installation and Operation Guide For

Transcription:

TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05 Operation...06 Errors and faults...08 Maintenance... 09 Disposal... 13 Declaration of conformity...13 Notes regarding the operating manual Symbols Hazardous electric current! Warns about hazards from electric current which can lead to injuries or even death. Legal notice This release replaces all previous versions. No part of this publication may be reproduced without written permission from TROTEC. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered. Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved. The scope of delivery may vary from product images. This document was created with all due care. TROTEC accepts no liability whatsoever for possible mistakes or omissions. TROTEC Danger! Warns of a hazard which can lead to personal injury. Caution! Warns of a hazard which can lead to damage to property. The current version of the operating manual can be found at: www.trotec.de EN Operating Manual Dehumidifier TTK 75 ECO 1

Information about the device Description of the device This device uses the principle of condensation to automatically dehumidify rooms. The fan sucks damp room air through the air inlet (6), the air filter (3), the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as either condensation or frost. The dehumidified, cooled air is warmed and blown out again. The drier air which is prepared in this way mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device. Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase into the condensation tray and through the integrated drain nozzle into the condensation tank (5) below. Once the maximum filling level of the condensation tank (5) is reached, the indicator light (7) lights up and the device switches off. The indicator light only goes out again once the emptied condensation tank (5) is reinserted. The condensed water can be diverted by attaching a hose at the condensation connection (4). The device can reduce the relative humidity of a room by up to approx. 30 %. The device serves to reduce the humidity level in living and working spaces, business premises, basements, laundry facilities and workshops. Because of the heat dissipation, which develops during operation, the room temperature can rise by approx. 1 C to 3 C. Device depiction 8 7 6 5 No. Designation 1 mains switch 2 transport handle 3 air filter 4 condensation connection 5 condensation tank 6 air inlet 7 indicator light condensation tank 8 operating hours counter 1 2 3 4 2 Operating Manual Dehumidifier TTK 75 ECO EN

Technical data Parameter Value Model TTK 75 ECO Dehumidification performance at 30 C and 80 % RH 20 kg / 24 h 6.4 kg / 24 h at 20 C and 60 % RH Operating conditions 5 C to 32 C with 30 % to 90 % RH Air flow rate 260 m 3 /h Recommended room size 20 m 2 / 60 m 3 Electric connection 230 V / 50 Hz Max. power input 0.44 kw Nominal current 1.6 A Starting current 10 A Fuse on site 7 A Condensation tank 4 l Refrigerant R134a Amount of refrigerant 190 g Weight 20.5 kg Dimensions (height x depth x 555 x 310 x 315 mm width) Minimum distance to walls or A: Top: 50 cm other objects B: Rear: 50 cm C: Sides: 50 cm D: Front: 50 cm Sound pressure level db (A) (1 m) 51 db (A) Wiring diagram EN Operating Manual Dehumidifier TTK 75 ECO 3

Safety Read this manual carefully before starting or using the device. Store the manual near the device or its site of use! Do not use the device in potentially explosive rooms. Do not use the device in aggressive surroundings. The device is designed for indoor installation. Set the device in an upright and stable position. Ensure that the air inlet and outlet are not obstructed. Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects. Never reach or put objects into the device. Do not cover or transport the device during operation. Ensure that all electric cables outside of the device are protected from damage (e.g. from animals). Only use extensions to the connecting cable which are appropriate to the device power consumption, the length of its cable and its use. Avoid electrical overload. Only transport the device with an emptied condensation tank. Dispose of the collected condensation. Do not drink it. Health hazard! Intended use Only use the device TTK 75 ECO for drying and dehumidifying room air, while adhering to and following the technical data. Improper use Do not place the device on wet or flooded ground. Do not use the device outdoors or for drying rooms and areas after water damages from burst pipes or flooding. Do not lay any objects, e.g. wet clothing, on the device for drying. Any unauthorised changes, modifications or alterations to the device are forbidden. Personnel qualifications People who use this device must: be aware of the dangers that occur when working with electric devices in damp areas. have read and understood the operating manual, especially the Safety chapter. Residual risks Hazardous electric current! Work on the electrical components must only be carried out by an authorised specialist company! Hazardous electric current! Before any work on the device, remove the mains plug from the mains socket! Danger! The device is not a toy and does not belong in the hands of children. Danger! Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications! Danger! Do not leave the packaging lying around. Children may use it as a dangerous toy. Caution! To avoid damages to the device, never operate the device without an air filter inserted! Caution! The feet of the device might rub off onto the ground. Use a suitable sheet or pad to protect the ground from potential discolouration and stains! Behaviour in the event of an emergency 1. Disconnect the device from the mains power in an emergency. 2. Do not reconnect a defective device to the mains power. 4 Operating Manual Dehumidifier TTK 75 ECO EN

Transport To make the device easier to transport, it is fitted with a transport handle. Before transporting the device, proceed as follows: Start-up Inserting air filter Before switching the device on, insert the air filter. 1. Switch off the device at the mains switch (1). 2. Remove the mains plug from the mains socket. 3. Empty the condensation tank. Check for dripping condensation. 4. Transport the device in an upright position. After transporting the device, proceed as follows: 1. Set the device in an upright position after transport. 2. Wait one hour before switching the device back on! Storage When out of use, store the device as follows: dry, with a roof overhead, in an upright position where it is protected from dust and direct sunlight, with a plastic cover to protect it from invasive dust, if necessary. The storage temperature is the same as the range given for the operating temperature in the technical data. EN Operating Manual Dehumidifier TTK 75 ECO 5

Operation Positioning Caution! The feet of the device might rub off onto the ground. Use a suitable sheet or pad to protect the ground from potential discolouration and stains! When positioning the device, observe the minimum distance from walls or other objects as specified in the technical data. A Switching the device on Note: Wait for 3 minutes before you switch the device back on (e.g. after draining the condensation tank). After being switched on, the device operates fully automatically until it is either switched off manually or a full condensation tank causes the device to switch itself off. The fan is running continuously until the device is switched off. Avoid open doors and windows. C D B C 1. Ensure that the condensation tank is empty and inserted correctly. Otherwise, the device will not operate! 2. Insert the mains plug into a properly secured mains power socket. 3. Actuate the mains switch (1). The device works automatically. Set the device in a level and stable position. If possible, set the device in the middle of a room and keep it away from sources of heat. When positioning the device in wet areas such as laundries, bath rooms or the like, secure the device locally with an RCD (Residual Current Device) which complies with the appropriate regulations. Ensure that extension cords are completely unrolled. Notes regarding the dehumidification performance Dehumidification performance depends on: the spatial composition of the room the room temperature the relative humidity The higher the room temperature and relative humidity, the higher the dehumidification performance. For using in living rooms, a relative humidity of approx. 50-60 % is sufficient. In store rooms and archives, the humidity should not exceed approx. 50 %. 6 Operating Manual Dehumidifier TTK 75 ECO EN

Operation with hose attached to the condensation connection D. A. B. Shutdown 1. Switch off the device at the mains switch (1). 2. Do not touch the mains plug with wet or damp hands. 3. Remove the mains plug from the mains socket. 4. Empty the condensation tank. Check for dripping condensation. 5. Clean the device, and especially the air filter, according to the chapter Maintenance. 6. Store the device according to chapter Storage. 10 mm C. EN Operating Manual Dehumidifier TTK 75 ECO 7

Errors and faults The accurate functionality of the device was tested during production a number of times. However, if functionality faults do occur, then check the device according to the following list. The device does not start: Check the power connection. Check the mains plug for damages. Check that the condensation tank is positioned correctly. Check the filling level of the condensation tank and empty it, if necessary. The indicator light (7) must not light up. Wait for 10 minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company for cooling and air-conditioning or by TROTEC. The device runs but forms no condensation: Check the float in the condensation tank for damages. If necessary, clean the condensation tank. The float must be able to move freely. Check the room temperature. Check the device's permissible operating range complies with the technical data. Check the air filter is not dirty. If necessary, clean or replace the air filter. From the outside, check the condenser for dirt (see chapter Maintenance). If your condenser is dirty, have it cleaned by a specialist company for cooling and air-conditioning or by TROTEC. The device is loud or vibrates; condensate is leaking: Check whether the device is standing upright and on an even surface. The device gets very warm, is loud or is losing performance: Check the air inlets and air filter are not dirty. Remove external dirt. From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air-conditioning or by TROTEC. Your device still does not operate correctly after these checks? Bring the device to a specialist company for cooling and air-conditioning or to TROTEC for repair. 8 Operating Manual Dehumidifier TTK 75 ECO EN

Maintenance Maintenance intervals Maintenance and care interval before every start as needed at least every 2 weeks at least every 4 weeks Maintenance and care log Device type:... Device number:... at least every 6 months at least annually empty condensation tank X check air inlets and outlets for dirt and foreign objects and clean if necessary X clean housing X X visually check the inside of the device for dirt X X check air inlet grid and air filter for dirt and foreign objects and clean or replace if necessary X X replace air filter X check for damages X check attachment screws X X carry out a test run X Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 check air inlets and outlets for dirt and foreign objects and clean if necessary clean housing visually check the inside of the device for dirt check air inlet grid and air filter for dirt and foreign objects and clean or replace if necessary replace air filter check for damages check attachment screws carry out a test run Remarks: 1. Date:... Signature:... 2. Date:... Signature:... 3. Date:... Signature:... 4. Date:... Signature:... 5. Date:... Signature:... 6. Date:... Signature:... 7. Date:... Signature:... 8. Date:... Signature:... 9. Date:... Signature:... 10. Date:... Signature:... 11. Date:... Signature:... 12. Date:... Signature:... 13. Date:... Signature:... 14. Date:... Signature:... 15. Date:... Signature:... 16. Date:... Signature:... EN Operating Manual Dehumidifier TTK 75 ECO 9

Activities required before starting maintenance 1. Do not touch the mains plug with wet or damp hands. 2. Before any work, detach the mains plug! Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by TROTEC. Visual check for dirt in the inside of the device 1. Remove the air filter (see chapter Cleaning the air filter). 2. Use a torch to illuminate the openings of the device. 3. Check the inside of the device for dirt. 4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air-conditioning or by TROTEC. 5. Put the air filter back in. Cleaning the air filter A. Caution! Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be rounded or misshaped. Before reinserting the air filter, ensure that it is dry and is not damaged! Read the chapter Maintenance intervals and replace the air filter in due time! B. Cleaning the housing 1. Use a soft, lint-free cloth for cleaning. 2. Dampen the cloth with clean water. Do not use sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. 10 Operating Manual Dehumidifier TTK 75 ECO EN

C. B. C. Emptying the condensation tank D. A. EN Operating Manual Dehumidifier TTK 75 ECO 11

Overview and list of spare parts Note! The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. No. Spare part No. Spare part No. Spare part 1 water tank 14 handle 27 capacitor (compressor) 2 coil assembly 15 housing 28 suction tube 3 capillary tube 16 power cord 29 discharge tube I 4 three exit tube II 17 discharge tube II 30 three exit tube 5 three exit tube 18 defrost tube 31 bypass valve 6 gas-in tube 19 air baffle 32 right faceplate 7 filter 20 fan wheel 33 compressor 8 gas-out tube 21 volute carapace 34 bottom plate 9 water plate 22 wire holder 35 middle bracket 10 left faceplate 23 controller 36 water tank baffle 11 lamp 24 capacitor (motor) 37 foot 12 hour meter 25 motor 13 switch 26 motor support 12 Operating Manual Dehumidifier TTK 75 ECO EN

Disposal In the European Union, electronic equipment must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2002/96/EC of the European Parliament and Council of 27th January 2003 concerning old electrical and electronic equipment. At the end of its life, please dispose of this device according to the valid legal requirements. The device uses an environmentally friendly and ozone-neutral cooling agent (see chapter Technical data). Prevent the refrigerant from escaping to the environment. Dispose of the refrigerant appropriately and according to the national regulations. Declaration of conformity in accordance with the EC Low Voltage Directive 2006/95/EC, Annex III, Section B and the EC Directive 2004/108/EC about electromagnetic compatibility. Herewith, we declare that the dehumidifier TTK 75 ECO was developed, constructed and produced in compliance with the named EC directives. Applied harmonised standards: EN 60335-1:2012, EN 60335-2-40:2003+A11:2004+A12:2005+A1:2006+ A2:2009+A13:2012, EN 62233:2008 The marking is found on the device nameplate. Manufacturer: Trotec GmbH & Co. KG Grebbener Straße 7 D-52525 Heinsberg Phone: +49 2452 962-400 Fax: +49 2452 962-200 E-mail: info@trotec.de Heinsberg, 31/03/2014 Managing Director: Detlef von der Lieck EN Operating Manual Dehumidifier TTK 75 ECO 13

Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com