Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

Similar documents
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Cleaning & Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

HIGH SPEED DRILL SYSTEM Instructions for Use. BUSAMedical.com

Reusable Laryngoscope Blades and Handles

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

Operating / User Manual

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

CLEANING INSTRUCTIONS

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

X99 Series. Dental Handpiece. Instruction For Use

User s Manual. Small Electric Drive. Compact and powerful system for use in hand and foot surgery.

Instructions for Use Spinal Punches IFU

STERITITE INSTRUCTIONS FOR USE

idrive Ultra Powered Stapling System

Instructions for Use: Fiberscope and LED Light Source

Cleaning and Sterilization for Instruments & Posts

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

I.F.U Re/Processing Reusable Medical Devices

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

ComPact Air Drive II USER S MANUAL

NIM-Response 3.0 NERVE INTEGRITY MONITORING SYSTEM

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

*smith&nephew VERSAJET HYDROSURGERY SYSTEM

VMS+ Cleaning and Disinfection Guide

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

WARNINGS AND PRECAUTIONS FOR THE USE OF THE IQ TM Intelligent Driver

Cleaning and Sterilisation for Burs, accessories and filling material

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

OPERATION AND MAINTENANCE MANUAL

2015 Myco Industries, Inc Fax:

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

USER GUIDE STEAM MOP STEAMREADY 1464 SERIES

Cavitator Ultrasonic Cleaner Instruction Manual

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Use and Care Guide. Over the Patient Units and Swing Mount Units

FLASH PAK STERILIZATION CONTAINER SYSTEM

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

OPERATION MANUAL. (Cleaning, Disinfection and Storage) Endoscope ED-530XT

Table of Contents. English

Additionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Instructions for Use A-dec Self-Contained Water System

POWEREDGE LIFT-OFF STEAM MOP USER GUIDE 2078 SERIES

Trauma Recon System (TRS). Battery-driven Power System designed for traumatology and arthroplasty.

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

Processing Instructions. Cleaning so easy.

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

6 things to consider. when designing your steri-center

Fiona Collins Liliana Donatelli Andrew Smith

RECOMMENDATIONS FOR CLEANING DEVICES

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

Best practices in Cleaning and Safety

Care instructions ESTETICA E80. Always be on the safe side.

USING THE REFRIGERATOR COMPARTMENT

Cavitron Systems, Sterilizable Handpieces and Reservoir Bottles INFECTION CONTROL PROCEDURES

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

User Manual J0841X. Piezo Electric Ultrasonic Scaler / Polisher Combo Unit. Jorgensen Laboratories, Inc.

SUS-12 Steam Cleaner User Manual

EZ9Plus & EZ11Plus Instructions on: Operating

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

Cavitator Ultrasonic Cleaners

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

VMS+ Cleaning and Disinfection Guide

Principles and Techniques of Instrument Processing and Sterilization

Aesculap Implant Systems

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Guidelines for cleaning, disinfection, and sterilization of the biopsy adaptor, water bag, coupler, and magnetic sensor securing adaptor

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

User Manual J841Q. Magnetostrictive Scaler / Polisher Combo Unit. Jorgensen Laboratories Tel: Fax:

When you sterilize an instrument set, you know what the standards are.

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Steam Mop USER S GUIDE 1867 SERIES. 3 Safety Instructions. Product View. Assembly 5-6. Special Features. Operation 7-8. Maintenance and Care 8-9

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Recommendations for cleaning, decontamination and sterilisation. devices

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

EL400 OPERATION MANUAL

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

Air-driven Universal Power Tool System for Traumatology, Endoprosthetics, and Spine. Compact Air Drive II. Instructions for Use

Instruction of use. Flexible Naso-Pharyngo- Laryngofiberscope,

1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. *only use. non-metal utensils

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

Transcription:

Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

Visao High-Speed Otologic Drill with the Integrated Power Console (IPC ) System High speed and torque 80,000 rpm max speed provides rapid, yet precise bone removal Cool running Water-cooled motor keeps the handpiece from overheating during long procedures 1

Created for neurotology 20 degree curved burs are specifically designed for working in tight, deep anatomic spaces Ergonomic Well-balanced and lightweight titanium body is easy to maneuver 33-3435 Extended Bur Guard with Irrigation 33-3425 Extended Bur Guard without Irrigation Easy assembly Snap fit reusable bur guards and quick locking burs make the Visao ideal for busy teaching institutions 2

Visao Curved Burs Use at speeds up to 80,000 rpm 4.0mm 3.0mm 2.0mm 90 mm 31154090E 31153090E 31152090E Fluted 115 mm 311740115E 311730115E 311720115E Flutes 8 10 90 mm 31184090E 31183090E 31182090E Diamond 115 mm 311940115E 311930115E 311920115E Diamond Grit 120/140 140/170 Coarse 90 mm 31204090E 31203090E 31202090E Diamond 115 mm 312140115E 312130115E 312120115E Diamond Grit 40/0 0/80 80/100 Visao Cochleostomy Burs Use at speeds up to 80,000 rpm 2.0mm Fluted 98 mm Flutes Diamond 98 mm Diamond Grit 98 mm Curved Bur 3

1.5mm 1.0mm 311715115E 311710115E 311910115E 90 mm Curved Bur 1.5mm 1.0mm 31151598E 31151098E 31181598E 115 mm Curved Bur 0.mm 0.5mm 31181098E 3118098E 31180598E 325/400 325/400 4

Visao Straight Burs Use at speeds up to 80,000 rpm Medium Working Length Long Working Length 23 mm X-Long Working Length 7 mm mm 5 mm 4 mm Medium 31317057U 3131058U 31315059U 3131405U Fluted Long 313150U 3131408U X-Long 31314075UE Flutes 12 10 8 8 Medium Working Length Long Working Length 23 mm 23 mm X-Long Working Length mm 5 mm 4 mm Medium 3113058 31135059 3113405 Diamond Long 311305 311350 3113408 X-Long 312158 3121584 Diamond Grit 120/140 120/140 120/140 Medium Working Length Long Working Length 23 mm X-Long Working Length mm 5 mm 4 mm Medium 3111058 31115059 3111405 Coarse Long 311105 311150 3111408 Diamond X-Long 31114075 Diamond Grit 40/0 40/0 40/0 5

3.5 mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm 3131355UE 3131305UE 3131255UE 3131205 3131155 313110 3131358U 3131309U 3131259 31312070 31311570 31311071 31313575UE 31313075UE 31312575 31312075 31311575 31311075 8 10 8 3.5 mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm 0.5 mm 3113355 3113305 3113255 3113205 3113155 311310 311305 3113358 3113309 3113259 31132070 31131570 31131071 31130571 31103075 31102575 31102075 31101575 31101075 31100575 140/170 325/400 140/170 3.5 mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm 3111355 3111305 3111255 3111205 3111155 311110 3111358 3111309 3111259 31112070 31111570 31111071 31113075 31112575 31112075 31111575 31111075 0/80 0/80 80/100 100/120 140/170 0/80

Other Shape Burs Other Shape Burs 1 per box Use at speeds up to 52,000 rpm Acorn Fluted Oval Fluted Pear Fluted Pear Coarse Diamond.9 mm.0 mm 5.0 mm 5.5 mm.0 mm.0 mm Medium 3132954 3132055 3132505 31255558 3123058 Long 312555 312304 312404 Flutes 8 8 8 14 14 Grit 100/120 7

8

Ordering Ordering Information Information 1898001 Integrated Power Console 1898430 Integrated Power Console Multifunction Footpedal 3334800 Visao High-Speed Otologic Drill 333425 Visao High-Speed Otologic Drill Extended Bur Guard Without irrigation 333435 Visao High-Speed Otologic Drill Extended Bur Guard With irrigation 3334895 Visao High-Speed Otologic Drill Sterilization Tray 1897821 US Power Cord, meter 1897510 Pole Basket for Footswitch 3318503 Irrigation Tubing Set, Sterile, 4/box 331850 Hi-Speed Drill Coolant Tubing Set, 2/bx 9

Visao High-Speed Otologic Drill Cleaning and Sterilization Instructions These products must be available for proper cleaning of the Visao drill: 311200, Medtronic ENT Cleaning Solution, 1 each 3112500, Chuck Brush Cleaner, 0/pack Complete these steps. 1. Prior to sterilization, wipe the drill and cable with a clean cloth soaked in enzymatic detergent solution. (Medtronic ENT Cleaning Solution 311200 and distilled water are recommended for best results.) 2. A chuck brush cleaner (3112500) or appropriately sized bristle brush may be inserted into the distal end of the Visao drill, irrigation sleeves and bur guards. 3. Rinse out the distal end of the drill. DO NOT IMMERSE! Shake out excess water. Rinse the irrigation nozzles and motor housing after use (distilled water is recommended for best results). 4. Clean and dry the instrument tray. 5. Dry the drill, cable, irrigation sleeve and bur guards thoroughly. Place them in their respective slots in the instrument tray. Automated Cleaning validation consists of a minimum 44 minute total time; including pre-wash; main wash and rinse; and thermal rinse. Thermal rinse shall be at least 10 minutes long at a minimum temperature of 0º. Warnings 1. Do not immerse! 2. Do not use an ultrasonic cleaner! 3. Do not use organic solvents, such as isopropyl alcohol or acetone, to clean drill! 4. Heating above 149 C (300 F) may damage the handpiece and will void the warranty. Sterilization Exposure Times Steam Autoclave/Gravity 121 C minimum (250 F) 40 minute cycle, minimum 8 minutes dry time (or until visibly dry) Steam Autoclave/Pre-Vacuum 132 C minimum (270 F) 4 minute cycle, minimum 8 minutes dry time (or until visibly dry) Sterrad Sterilization (Sterrad 100S compatible) Only the drill is compatible Irrigation sleeves and bur guards are not compatible Ethylene Oxide Concentration: 00+/-25mg/L Sterilization: 54 C to 55 C (129 F to 131 F) Relative Humidity: 0+/-5% Aeration: 48 C to 52 C (118 F to 12 F) for 8 hours Exposure Time: (full cycle) 120 minutes Wrap: A standard, sterilization wrap may be used. In the US, an FDA approved surgical wrap must be used. Wrap tray using appropriate method. Ensure that the pack is large enough to contain the instrument without stressing the seals. Instruments may be loaded into dedicated instrument trays or general purpose sterilization trays. Ensure that cutting edges are protected. 10

For more information, contact your Medtronic NT sales representative or refer to www.medtronic.com. Medtronic Powered Surgical Solutions 420 North Beach Street Fort Worth, TX 7137 USA Internet: www.medtronic.com Telephone: 817-788-400 Toll-free: 800-43-2773 Fax: 817-788-401 AUTHORIZED REPRESENTATIVE IN EU: Medtronic B.V. Earl Bakkenstraat 10, 422 PJ Heerlen The Netherlands Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. Refer to product package insert for instructions, warnings, precautions and complications. LIT250021EN.RNew 2008, Medtronic, Inc. Registered mark of Medtronic, Inc.