Installation Manual BCS 1000/1500

Similar documents
Installation Manual BCS2000/3000

WineZone Ceiling Mount Ductless Split 15

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

Warm Case Troubleshooting Guide 9/18/2014

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Condensing Unit Installation and Operating Instructions

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Split Floor-Mounted Cooling System Operation Care Installation Manual

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C)

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Read and save these instructions

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Hoshizaki America, Inc.

VertiCool Aurora Engineering Guide

Condensing Unit and Refrigeration System Installation & Operations Manual R448A/R449A

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

NO: 9-16 DATE: 2/11/16 EMERSON CLIMATE TECHNOLOGIES WHOLESALERS -EXECUTIVES -PRODUCT MANAGERS -EMERSON TM TECHNICAL SPECIALISTS -BRANCH PERSONNEL

Read and save these instructions

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD!

Read and save these instructions

KTL Two-Way Low Profile Evaporators

Owners Manual Refrigerated Air Dryer MHT SERIES

Air Conditioning Operation and Troubleshooting Matt Dunham

VariCool VAV Engineering Guide

R Series Cooling Modules

Read and save these instructions

INSTRUCTIONS! DO NOT DISCARD!

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD

MASS. MARITIME ACADEMY

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Contour TM Screw Compressors

RCM Refrigerant Module

Hoshizaki America, Inc.

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Read and save these instructions

Call us today! (800)

PLATINUM SPLIT TWIN TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

Prodigy Eclipse Cuber Technical Training

Hoshizaki America, Inc.

R Series Cooling Modules

Scotsman Technical Training. CU50 Cube Ice Machine

EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions

HP50HA ABG Heat Pump

C13-Series Engineering Guide

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Otherwise, you can continue reading the file on the following pages.

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

NO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL

Kramersaver Air Cooled Condensing Units

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

DRYMAX DRYMAX DRYMAX DRYMAX

RDT Refrigeration Book

Call us today! (800)

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

MODEL URS-1: FACTORY RETROFIT PROGRAM

Welcome to the Ice-O-Matic on-line training modules. Ice. Pure and Simple

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

KM-630MAH KM-630MWH KM-630MRH

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

INSTALLATION MODULE XARIOS RANGE. UTC Climate, Controls & Security PROPRIETARY Rev B 29th mai 2013

12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KML F SERIES KML H SERIES

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Split Wall-Recessed Cooling System Operation Care Installation Manual

MAGNUM SERIES OWNER S MANUAL. Magnum SS9000 Magnum SS12000 QS

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

CEILING MOUNT. VERSION 2 TECHNICIAN'S MANUAL 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

High Profile Evaporator

Call us today! (800)

KM-630MAF KM-630MWF KM-630MRF

CoolSpot Engineering Guide

ENGINEERING SPECIFICATIONS

Installation, Operation, and Maintenance Information

Transcription:

Installation Manual BCS 1000/1500 Supplies Needed for Installation 1. Double insulated refrigerant line set. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120V 15A circuit for indoor evaporator, and 120V/230V 30A, single or three phase (dependent upon your condensing unit) for outdoor condensing unit. Check local codes. 5. 18-2 stat wire; to be used to extend temperature sensor, humidity sensor cable, keyboard. 6. Condensing unit pad Condensing Unit Set Up 1. Place a (suggested model) on a firm level location (pad) for outdoor applications, or add 4 anti-vibration pads to each corner of the condensing unit for indoor use. Place in an area with adequate air flow. 2. Braze in suction and liquid lines to condensing unit. 1

3. Run the recommended double insulated line set from the condensing unit to the evaporator opening (50 foot max.). 4. Power from disconnect (recommended) 12-2/with ground to the condensing unit. 5. Check low pressure control for the correct 25 psi setting, with a 15 psi differential. Diagram 1 Evaporator Set Up 1. Locate a suitable ceiling mount location, as close to the middle of the room as possible. Allow for at least 24 inches from the back of the evaporator (coil side) to the back wall for adequate air distribution. 2. Run the 1/4 drain line from the pump in the evaporator through the ceiling cap and out to a suitable location. Heat tape any portion susceptible to freezing.. 3. Attach template to the ceiling. Remove the stainless steel outer enclosure from the base of the unit. Attempt to locate any mounting holes below ceiling joists for secure attachment with (#8) wood screws. Use moly bolts for all other mounting locations. Attach base securely to the ceiling. (diagram 1) Minimum 7 mounts. 4. Bring in power (14-2/with ground) to an approved box and connect to wire in harness outside evaporator. 5. Attach template to the ceiling. Remove the stainless steel outer enclosure from the base of the unit. Attempt to locate any mounting holes below ceiling joists for secure attachment with (#8) wood screws. Use moly bolts for all other mounting locations. Attach base securely to the ceiling. (Diagram 1) Minimum 7 mounts 2

EVAPORATOR SET UP, continued 6. Wrap the TXV and refrigeration solenoid with ESP Heat block (#HB34) or comparable product. Braze the refrigerant solenoid to the liquid line. Remove the TXV bulk and braze in the suction line to the line exiting the condenser. Re-attach the bulb when cool. 7. Locate the nearest water supply. Shut off water supply to the line and braze in the CPS water supply compression adapter. Connect the water filter to the fitting and run ¼ copper from the filter thru the evaporator ceiling opening and cap, and attach to the water solenoid inlet in each evaporator. 8. Attach the 1/4 vinyl hose drain tube to the outlet of the green condensate pump. 9. For indoor applications, run 1/4 vinyl condensate drain tube from the evaporator to a suitable location 10. Do not replace cover until unit test is complete. 3

Controller Display Set Up 1. Install double gang box and cut out the blank plate to accept the Bacchus Temp/Humidity Keyboard (VH620). The keyboard can be mounted inside or outside of the room. Run 18-2 stat wire from the monitor back to the evaporator above the ceiling opening, and attach to the yellow and green lead wires indicated. The keyboard can be mounted up to 75 feet from the microprocessor inside the evaporator. 2. Mount the humidity sensor (XH10P) to a discreet side wall location @ 6ft. from the floor. Bring the two lead wires from the sensor, and attach to the + and lead wires indicated. White lead to the #2 terminal, and Red lead to the #1 terminal on the sensor. Do not mount in the air discharge (coil side) of the evaporator. 3. Mount the temp sensor adjacent to the humidity sensor, and run the lead wires back to the wire harness. It is best to place both sensors in a location where they cannot be touched by the end user, and are not in the air discharge of the evaporator. VH620 Keyboard 4. Check supply voltage before connecting to the controller/power board. 5. Do not expose to water or moisture: use the controller only Within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. 6. Warning: disconnect all electrical connections before any kind of maintenance 7. Ensure that the wires for probes leads and the power supply are separated and are not intertwined or crossed. XH10P Humidity Sensor 8. The microprocessor has been preprogrammed for 55F and 50% RH. To change either setting: E. Depress the up ^ and down v keys together for more than three seconds to unlock the keyboard F. Push the Temp or Humidity Set Key and immediately Release G. Use the up^ and down v keys to change the value H. Push the appropriate set key again, and wait 10 seconds I. Depress the up^ and down v keys to lock the keyboard. 18NB1 9. There is no reason to change any besides temperature or humidity set point depending upon the end users preference. 10. IMPORTANT: In some instances, very tightly insulated rooms, or rooms with outside humidity infiltration can have a call for dehumidification. In that mode, refrigeration turns on until humidity is decreased to set point. If this occurs, reset humidity set point up 5% higher than original set point. A high of 70% RH is allowable. 4

11. Alarm Signaling Message Cause Outputs P1 Thermostat probe failure compressor and heating outputs off (on dehumidification system only) P3 Humidity probe failure humidity regulation off HA High temp alarm outputs unchanged LA Low temperature alarm outputs unchanged HHA High humidity alarm outputs unchanged HLA Low humidity alarm outputs unchanged In the instance of any of these alarms, call Bacchus Tech Services, or your installation contractor. Power to the Evaporator 1. Bring in 14-2 conductor wire with ground to the evaporator, and connect to the 14-2 with ground wire harness exiting the evaporator. Make sure the line has adequate amp rating for the circuit. 5

Charging the System 1. Evacuate and pressure test the system. This can be accomplished by charging with nitrogen to 75 lbs and checking your gauges for any sign of a leak. Evacuate the system to 500 microns. 2. Charge the system with R134A until the sight glass goes clear. It is very important not to overcharge this system. As soon as the bubbles in the sight glass disappear, discontinue charging. Overcharge will result in an ice block in the evaporator. 3. Adjust the TXV to 12-14 degrees of superheat. Take your suction pressure and temperature reading at the condenser, and add two pounds to it for the pressure drop. Take the difference between actual temperature and your reading from a PT chart to calculate. 4. System Start up. Before replacing stainless steel enclosure cover, power up the system to make sure water solenoid is opening correctly. The misting nozzle will be open. Remove power and replace the cover. Power up the evaporator, and let the system pull down. At temp set point the refrigerant solenoid will close and the system will pump down and shut off the condensing unit. 5. Check level of safety float. Breakers. We recommend a 30a fused disconnect. Maintenance and Troubleshooting Have your system checked each year by a certified refrigeration technician. He should: 1. Clean the indoor and outdoor coils 2. Change the water filter on the Humidification models, and change out the humidification mister head 3. Drain the Stainless steel sump (diagram #3), and clean it if necessary. This will prevent any possible mold build up. 4. Check the operation of the condensate pump, and make sure the water misting fitting is acting properly, by allowing water to flow thru it. Clean with vinegar if clogged and change the water filter. 5. Check the electronic controller for any alarm conditions 6. Check the refrigerant level and system operating pressures. 7. Clean the water solenoid on a yearly basis, and change it out every two years. Warning: If the water solenoid sticks open, overflow can result. 6

Troubleshooting Alarm conditions on the electronic controller, Call BCS Tech Services at 937-665-0424 Unit will not reach temperature Unit has shut off Call your installation contractor to Determine proper refrigerant charge. Dirty condenser? Call BSC tech services or field Service; could be bad Compressor, fans, controller or Pump Alarm Signaling Message Cause Outputs P1 Thermostat probe failure compressor and heating outputs off (on dehumidification system only) P3 Humidity probe failure humidity regulation off HA High temp alarm outputs unchanged LA Low temperature alarm outputs unchanged HHA High humidity alarm outputs unchanged HLA Low humidity alarm outputs unchanged In the instance of any of these alarms, call Bacchus Tech Services, or your local service contractor. Dimensional /Electrical BCS1000 BCS1000 BCS1500 BCS1500 BCS2000 BCS3000 Cond. Unit Evap. Con. Unit Evaporator Con. Unit Con. Unit Dims. 17 D x 13.3 W 18 D x 29.25 W 19 D x 16.2 W 18 D x 29.25 W 19 D x 21 W 25 D x 20 W x 11.8 H x 6.5 H x 14 H x 6.5 H x 16.5 H x 16 H Weight 51 lbs. 49 lbs. 62 lbs. 51 lbs. 81 lbs. 135 lbs. Refrigerant 3/8 suc. 3/8 sw 3/8 suc 3/8 sw x 3/8 suc ½ suc Connection 1/4 dis. ¼ dis ½ sw 5/16 dis 3/8 dis Water Supply ¼ ¼ Connection compression compression Condensate ¼ mpt ¼ mpt Connection Compressor 1/2 hp 115v.65 hp 115v 1 hp 115v 1 ½ Hp HP/voltage 208/230-1v Electrical compressor rla 10A 11A 8A 12.1A compressor lra 53A 51A 43A 49A cond. Unit MFS 20A 30A 15A 17.6A cond. Unit mca 13.4A 13.4A 11.3A 12.1A BTU capacity 40F 4857 6250 10200 (100 amb) 12,185 suc, 110 amb. 7

Phone: 937-665-0424 Fax: 937-890-6664 8