Ceiling Mounted Cassette Unit

Similar documents
Ceiling Mounted Cassette Unit

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PLXSID1605. Warning HEAD OFFICE :

Inverter Y Series.

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

All Product Catalogue

Inverter Wall Mounted Series

RC-0219-A. Single-Split Non Inverter Series

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

R410A Multi Digital Scroll System

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Innovative air conditioning

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Light commercial range. Passion at work

U-Match Systems 12,000 to 60,000 BTU/Hr 60 Hz

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

Residential and Light Commercial Ductless Systems Catalog

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Inventor of the Inverter Digital Inverter System

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Inverter Wall Mounted

Ultimate VRF System R410A, 50Hz

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

About Daikin: WARNINGS:

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

THE WORLD S MOST EFFICIENT HEAT PUMP

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

DUCTLESS FULL LINE CATALOG

Model: Ceiling Cassette V 9k-24k

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Hi - Wall Split Systems 12K - 18K - 24K

HEAT PUMPS. Efficient Comfort For Every Season

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

2 &3-4 Head Multi System

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Business. The business range. The most advanced solutions for larger buildings.

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Presents. Variable Speed Heat Pump Ductless Split Systems

Multi Digital Scroll System (R-22 and R-410A)

Energy-saving operation

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Product Section New Product Introduction

Q Series. Inverter Split Systems

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

AIR CONDITIONING REVERSE-CYCLE INVERTER

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

A single answer for multiple zones.

Heat Pump Air Conditioning Systems

Non Inverter Wall Mounted Series

Wall Mounted Split Systems

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Carrier. Ductless Systems. Taking Comfort, And Your Business, Further. The Right Solution. Right Now.

Specifications, Performance & Submittal

42GWC Hydronic Cassette Fan Coil Units

Ductless Series Variable Speed Split Systems

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Samsung 360 Cassette, Single Zone, Split System

SKM. Air Conditioners TROPICAL

Air Conditioning & Heating. Ductless Product Catalog

Inverter Wall Mounted

Duct-Free Systems For cooling and heating solutions, the world turns to Carrier in 2005

Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II Inverter Y Single Split Series II

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

ART الرفاهية تكنولوچيا بلمسة فنية

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

A single answer for multiple zones.

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

Ductless Split Systems Ceiling Cassette Heat Pumps

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

HI-WALL SPLIT SYSTEMS

E Z S E R I E S " W X 16" H

Digital Variable Multi Units MODEL: AMDS080-AMDS300B(R) COOLING CAPACITY: 24.5KW-80KW HEATING CAPACITY: 26KW-85KW. MDS-B-50Hz

Transcription:

CEILING CASSETTE A5CK-E SERIES - R410A COOLING ONLY A5CK20E A5CK25E A5CK28E A5CK40E A5CK40E A5CK40E A5CK40E A5CK50E A5LC20C A5LC25C A5LC28C A5LC35D A5LC35D A5LC40D A5LC40D A5LC50D Btu/hr 18300 22200 27000 29200 31000 39000 39000 45000 W 5363 6506 7913 8558 9086 11430 11430 13190 W/W 3.08 3.36 2.84 3.03 3.28 2.92 2.98 2.93 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 300 [375] 300 [375] 300 [375] 300 [375] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] 39 [43] 39 [43] 39 [43] 41 [45] 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 52 52 58 58 58 58 58 60.00 852 852 852 852 1030 1030 1030 1030 400 400 400 400 Net Weight kg 47 50 57 86 86 95 95 98 Pipe Connection - Liquid mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52 Pipe Connection - Gas mm 12.70 15.88 15.88 15.88 15.88 15.88 15.88 15.88 CEILING CASSETTE A5CK-ER SERIES - R410A HEATPUMP A5CK20ER A5CK25ER A5CK28ER A5CK40ER A5CK40ER A5CK40ER A5CK40ER A5CK50ER A5LC20CR A5LC25CR A5LC28CR A5LC35DR A5LC35DR A5LC40DR A5LC40DR A5LC50DR Btu/hr 18300 22200 27000 29200 31000 39000 39000 45000 W 5363 6506 7913 8558 9086 11430 11430 13190 Btu/hr 17700 20500 28000 31800 33400 39000 39500 48000 W 5188 6008 8206 9320 9789 11430 11577 14070 W/W 3.08 3.36 2.84 3.03 3.28 2.92 2.98 2.93 W/W 3.48 3.41 3.53 3.66 3.84 3.06 3.21 3.43 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 300 [375] 300 [375] 300 [375] 300 [375] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 26 [30] 28 [32] 31[35] 39 [43] 39 [43] 39 [43] 39 [43] 41[45] 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 52 52 58 58 58 58 58 60 852 852 852 852 1030 1030 1030 1030 400 400 400 400 Net Weight kg 47 50 57 86 86 95 95 98 Pipe Connection - Liquid mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52 Pipe Connection - Gas mm 12.70 15.88 15.88 15.88 15.88 15.88 15.88 15.88 4) FOR A5CK 20/25 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA FOR A5CK 28/40/50 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. 2013 Acson International AP-ACK-13 www.acson-international.com Ceiling Mounted Cassette Unit

Ceiling Cassette C series 4 Way Air Discharge And Air Swing It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room. Auto Mode Auto Mode allows the setting to change automatically between cool and heat mode depending on the room temperature and the set temperature required. Stylish And Slim Panel The slim panel can be blended easily into interior decoration and design. A(5)CK 10/15/20C/CR Built-In High Head Drain Pump The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level. 700mm Hot Keep Cycle During heat mode hot keep cycle, the fan will run at low speed during the thermostat cycle off. As a result, one will not feel the draft of cold air discharge from the unit. Option of fan stop or fan run at specific interval timing can also be selected. Self Diagnosis This intelligent feature helps to detect any faults or malfunctioning in the system and give user a warning by blinking of the LED lights. Compact Design The Ceiling Cassette C series is designed to be compact. Its body dimension is only 570mm x 570mm which can easily fit into a 600mm ceiling grids. This make installation a lot easier. Ceiling panel T bar NIM-Able The ACK-C series is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a systems of multiple indoor units in a building. * Refer local representative for details. 600 mm Cooling 9500 Btu/h - 19000 Btu/h 2.78 kw - 5.57 kw Heating 9500 Btu/h - 19500 Btu/h 2.78 kw - 5.72 kw A(5)LC 10/15C/CR GS02 SLM 9 Wired Controller (Field Installed Optional Accessories) A(5)LC 18/20C/CR Choices Of Wired And Wireless Controller

Ceiling Cassette E series Optimum Air Discharge Combining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional of the automatic air swing help further to evenly distribute conditioned air to every corner of the instrall area. Modern And Elegant Panel It is designed with unique round side contour and new LED light location. Rotateable intake grill promote uniform installation. A(5)CK 20/25/28/40/50E/ER Superior Sound Level The ACK-E series is equipped with a newly-developed turbo fan; the shape produce low air turbulence. Allow 90 Rotation Model A(5)CK 20E/ER A(5)CK 25E/ER A(5)CK 28E/ER A(5)CK 40E/ER A(5)CK 50E/ER Max (dba) 34 37 42 47 49 Min (dba) 28 32 33 36 39 With up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 28dBA. Multi-Comfort - 3 Air Swing Pattern Control To increase the comfort level of the air conditioned area of ACK-E series, the system had been built in with 3 different type of air flow pattern to suit different requirement. PATTERN 1 PATTERN 2 PATTERN 3 50 50 55 55 Standard Setting For gentle drafts. Draft Prevention Setting Select this setting to eliminate direct drafts which can lead to discomfort. Setting to Prevent Soiling of Ceiling Recommended for location with light colour ceiling that must be kept potless. The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control. A B Cooling 18300 Btu/h 49500 Btu/h 5.3 kw 14.5 kw Heating 17700 Btu/h 50000 Btu/h Lower Height Model The ACK-E series height is as low as 300mm to ease installation. Dimension (mm) Model A B A(5)CK 20~28E/ER 265 300 A(5)CK 40~50E/ER 300 335 5.1 kw 14.7 kw Built-In High Head Drain Pump The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level. 700mm

CEILING CASSETTE ACK-C SERIES - R22 COOLING ONLY CEILING CASSETTE A5CK-C SERIES - R410A COOLING ONLY ACK 10C ACK 15C ACK 20C ACK 20C A5CK 10C A5CK 15C A5CK 20C A5CK 20C ALC 10C ALC 15C ALC 18C ALC 20C A5LC 10C A5LC 15C A5LC 20C A5LC 20C Btu/h 9500 12500 18000 19000 W 2780 3663 5280 5570 Btu/hr 9500 12500 17500 18000 W 2780 3660 5129 5280 W/W 3.03 3.04 2.87 3.04 W/W 3.09 2.82 3.03 3.06 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 46 49 52 51 Sound Pressure Level dba 46 49 52 52 Net Weight kg 28 28 43 47 Net Weight kg 28 30 47 47 Pipe Connection -Gas mm 9.52 12.70 15.88 15.88 Pipe Connection -Gas mm 9.52 12.70 12.70 12.70 CEILING CASSETTE ACK-CR SERIES - R22 HEATPUMP CEILING CASSETTE A5CK-CR SERIES - R410A HEATPUMP ACK 10CR ACK 15CR ACK 20CR ACK 20CR A5CK 10CR A5CK 15CR A5CK 20CR A5CK 20CR ALC 10CR ALC 15CR ALC 18CR ALC 20CR A5LC 10CR A5LC 15CR A5LC 20CR A5LC 20CR Btu/h 9500 12500 18000 19000 W 2780 3660 5280 5570 Btu/hr 9500 12500 17500 18000 W 2780 3660 5129 5280 Btu/h 9500 12500 18400 19500 W 2780 3660 5390 5720 Btu/hr 9500 11500 17500 18500 W 2780 3370 5129 5420 W/W 3.03 3.04 2.87 3.04 W/W 3.09 2.82 3.03 3.06 W/W 3.40 3.47 3.21 3.21 W/W 3.35 3.30 3.00 3.63 Sound Pressure Level dba 46 49 51 51 Net Weight kg 30 30 43 47 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 46 49 52 52 Net Weight kg 28 30 47 47 Pipe Connection -Gas mm 9.52 12.70 15.88 15.88 Pipe Connection -Gas mm 9.52 12.70 12.70 12.70 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD.

CEILING CASSETTE ACK-E SERIES - R22 COOLING ONLY ACK 20E ACK 25E ACK 28E ACK 40E ALC 20C ALC 25C ALC 28C ALC 35D Btu/h 19500 25000 27000 35000 W 5715 7327 7913 10258 W/W 2.92 2.88 2.91 3.41 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Sound Pressure Level dba 51 52 58 58 CEILING CASSETTE ACK-ER SERIES - R22 HEATPUMP ACK 20ER ACK 25ER ACK 28ER ACK 40ER ALC 20CR ALC 25CR ALC 28CR ALC 35DR Btu/h 19500 25000 27000 35000 W 5715 7327 7913 10258 Btu/h 19500 25000 28000 35000 W 5715 7327 8206 10258 W/W 2.92 2.88 2.91 3.41 W/W 3.38 3.17 3.49 3.73 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Net Weight kg 47 57 57 95 Pipe Connection -Liquid mm 6.35 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 19.05 Sound Pressure Level dba 51 52 58 58 Net Weight kg 47 57 57 95 Pipe Connection -Liquid mm 6.35 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 19.05 ACK 40E ACK 40E ACK 50E ALC 40D ALC 40D ALC 50D Btu/h 39000 39500 49500 W 11430 11600 14500 W/W 3.31 3.17 3.15 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] Width [with Panel] mm 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 ACK 40ER ACK 40ER ACK 50ER ALC 40DR ALC 40DR ALC 50DR Btu/h 39500 39500 48000 W 11600 11600 14100 Btu/h 42000 42000 50000 W 12300 12300 14700 W/W 3.22 3.31 2.93 W/W 3.79 3.85 3.49 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] Width [with Panel] mm 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] Net Weight [with Panel] kg 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 Height mm 852 852 852 Width mm 1030 1030 1030 Depth mm 400 400 400 Net Weight kg 100 100 105 Pipe Connection -Liquid mm 9.52 9.52 9.52 Pipe Connection -Gas mm 19.05 19.05 19.05 Sound Pressure Level dba 58 58 58 Height mm 852 852 852 Width mm 1030 1030 1030 Depth mm 400 400 400 Net Weight kg 100 100 105 Pipe Connection -Liquid mm 9.52 9.52 9.52 Pipe Connection -Gas mm 19.05 19.05 19.05 II) FOR ACK 28/040/050 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. II) FOR ACK 28/040/050 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD.

CEILING CASSETTE A5CK-E SERIES - R410A COOLING ONLY A5CK 20E A5CK 25E A5CK 28E A5CK 40E A5LC 20C A5LC 25C A5LC 28C A5LC 35D Btu/hr 18300 22200 27000 29200 W 5363 6506 7913 8558 W/W 3.08 3.36 2.84 3.03 Net Weight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] Sound Pressure Level dba 52 52 58 58 Net Weight kg 47 50 57 86 Pipe Connection -Liquid mm 6.35 6.35 9.52 9.52 Pipe Connection -Gas mm 12.70 15.88 15.88 15.88 CEILING CASSETTE A5CK-ER SERIES - R410A HEATPUMP A5CK 20ER A5CK 25ER A5CK 28ER A5CK 40ER A5LC 20CR A5LC 25CR A5LC 28CR A5LC 35DR Btu/hr 18300 22200 27000 29200 W 5363 6506 7913 8558 Btu/hr 17700 20500 28000 31800 W 5188 6008 8206 9320 W/W 3.08 3.36 2.84 3.03 W/W 3.48 3.41 3.53 3.66 Net Weight [with Panel] kg 26 [30] 28 [32] 31[35] 39 [43] Sound Pressure Level dba 52 52 58 58 Net Weight kg 47 50 57 86 Pipe Connection -Liquid mm 6.35 6.35 9.52 9.52 Pipe Connection -Gas mm 12.70 15.88 15.88 15.88 A5CK 40E A5CK 40E A5CK 40E A5CK 50E A5LC 35D A5LC 40D A5LC 40D A5LC 50D Btu/hr 31000 39000 39000 45000 W 9086 11430 11430 13190 W/W 3.28 2.92 2.98 2.93 Air Flow CFM 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] 300 [375] Net Weight [with Panel] kg 39 [43] 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 60 A5CK 40ER A5CK 40ER A5CK 40ER A5CK 50ER A5LC 35DR A5LC 40DR A5LC 40DR A5LC 50DR Btu/hr 31000 39000 39000 45000 W 9086 11430 11430 13190 Btu/hr 33400 39000 39500 48000 W 9789 11430 11577 14070 W/W 3.28 2.92 2.98 2.93 W/W 3.84 3.06 3.21 3.43 Air Flow CFM 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 300 [375] 300 [375] 300 [375] 300 [375] Net Weight [with Panel] kg 39 [43] 39 [43] 39 [43] 41[45] Power Supply V/Ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50 Height mm 852 852 852 852 Sound Pressure Level dba 58 58 58 60 Width mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net Weight kg 86 95 95 98 Pipe Connection -Liquid mm 9.52 9.52 9.52 9.52 Height mm 852 852 852 852 Width mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net Weight kg 86 95 95 98 Pipe Connection -Liquid mm 9.52 9.52 9.52 9.52 Pipe Connection -Gas mm 15.88 15.88 15.88 15.88 Pipe Connection -Gas mm 15.88 15.88 15.88 15.88 II) FOR ACK 28/40/50 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. II) FOR ACK 28/40/50 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD.