Heat recovery unit RDKS. Technical instructions for installation, operation and maintenance

Similar documents
HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Heat recovery unit RDKS

VEKA ver C SUPPLY AIR UNIT IINSTALLATION AND MAINTENANCE

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

VEKA ver C Supply air unit

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

TopMaster Air Handling unit. Technical data

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

IMPORTANT SAFETY REMINDERS

KOMFORT EC DB Suspended heat recovery air handling units

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

26 FIREBOX EN RU UA FR

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

- 1- IMPORTANT SAFETY REMINDERS

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Instructions for use

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

User and maintenance manual

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Instructions for use

EDD61 & EDD91 Extractors

GLEB Kitchen exhaust fan

Swegon CASA W80 EC, version B

Warnings, Safety Information and Guidance

G Installation manual Solitude - dmev unit

- 1- IMPORTANT SAFETY REMINDERS

EVP61/91/101/121. Extractor. Installation, use and maintenance.

IMPORTANT SAFETY REMINDERS

Instructions for use

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

GB User and maintenance manual

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Supply air unit VEKA Installation & Maintenance

Cooker Hood User Manual

VETO CLEANER 500 FLUE GAS CLEANER

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Topvex SR03, SR04, SR06 Compact Air Handling Unit

EVX101 Extractor Installation, Use and Maintenance

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

INSTALLATION INSTRUCTIONS USER GUIDE

HEAT RECOVERY AIR HANDLING UNIT

Thank you for choosing EnviroVent

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

DC740 Built-under & DC940 Built-In

MODBUS RS485 TECHNICAL INSTRUCTIONS

ORC93XA ORC94XBA. Wall Canopy Rangehoods

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

EKP Extractors Installation, Use and Maintenance

HOTLINE:

INSTALLATION & USER INSTRUCTIONS

ISCG90SS _03 ISCG90SS

User manual AG-WT10. Indoor unit air/air heat pump UHB GB LEK

Swegon CASA. R85, version B. Instructions for installation, operation and maintenance. R85B_h_EN-m

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

CPD COOKER HOOD TECHNICAL DATA

IMPORTANT SAFETY REMINDERS

- 2 - IMPORTANT SAFETY REMINDERS

TopMaster Air Handling unit. Installation instructions

IMPORTANT SAFETY REMINDERS

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

Congratulations on the purchase of your new Hoover Smart.

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

VH60SS 60CM VISOR HOOD STAINLESS STEEL

IMPORTANT SAFETY REMINDERS

Swegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

- 2 - IMPORTANT SAFETY REMINDERS

USER MANUAL Turbopower IM UK.indd /6/5 17:36:44

Box60/ 70/ 90. Box60_70_90 v8

Cooker Hood Instruction Manual

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Cooker Hood Instruction Manual

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

MANUAL INTELLIVENT CELSIUS

V 120 SG - V 160 SG. Instructions for use

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

LTR-3-EC LTR-3-ECE PLANNING, INSTALLATION AND OPERATION INSTRUCTIONS

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

V-ZUG Ltd. Range hood. Levante. Operating instructions

Sentinel Kinetic MVHR RANGE

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

DUST MANAGER USER INSTRUCTIONS

EVG Extractors. Manual for Installation, Use and Maintenance

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Hand Dryer Installation & User Manual

Series VENTS VUT R WH ЕС

SAVE VTC 700. Heat Recovery Ventilation Unit

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

WHHR Midi & Midi Lite

Transcription:

for installation, operation and maintenance Software version: 1.19 June 2013

Contents Maintenance (for the user) Operation and Maintenance - Functions... 3 Managing the control panel functions... 4 Control panel - overview of symbols and functions... 5 Maintenance and cleaning of heat exchanger and fans... 6 Filter alarm, filter replacement... 7 Installation (for installers and service personnel) Installation - Dimensions, definitions... 8 Duct connection, insulation of ducts... 9 Installation of unit with accessories... 10 djustment, commissioning (for installers and service personnel) djustment, commissioning... 13 Electrical connection and wiring diagram... 14 djustment of fan speeds and temperature setpoint value... 15 Control panel and List of parameters... 16 Miscellaneous Spare parts... 17 Installation instruction of panel RDKZ-41... 18 EU confirmation of conformity... 19 WRNING! The device can be used by children from 8 years upwards and people (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have received guidance or information on how to use the device safely and understand the risks that can occur. Children should not play with the appliance. Cleaning and maintenance is not carried out by children without supervision. Note! Installation, adjustment and commissioning that is described in this manual must be carried out by competent, authorised personnel. Fläkt Woods GB 9295 2013.06 2 We reserve the right to make changes.

Operation & Maintenance - Functions Comfort The unit controller card controls the rotary heat recovery unit and any additional heating to maintain the supply air temperature at the desired level. Energy savings The unit controller card provides stepless control of the fans to achieve the desired air flow. The type of fans used has so-called electronically commutated (EC) motors, which are very energy efficient. Thanks to the energy efficient fans and the fact that the air flow can be adjusted steplessly, energy consumption is reduced. Heat consumption is minimised through the use of a rotary heat recovery unit. This recovers the heat from the exhaust air and transfers it to the supply air. Heat recovery & dditional heating In climates where the temperature seldom drops below 10 C, the rotary heat recovery unit usually recovers enough thermal energy and no additional heating is required. t lower external temperatures, when the supply air cannot achieve the desired temperature, a post-heating battery is required, which can be controlled to maintain the set supply air temperature. In very cold areas there is also a facility to supplement the unit with an electric heater battery, which pre-heats the outdoor air. This battery starts to provide heating when the external temperature falls below 12 C. Defrosting During cold periods, when frost could form in the impeller, the built-in control unit automatically takes care of defrosting. The unit defrosts for 15 minutes every 6 hours if the external temperature is lower than -10 C. The supply air stops and the impeller moves forward in sections. Cooling recovery In the summer, if the exhaust air is cooler than the outdoor air, the rotary heat exchanger starts to recover cooling from the cooler exhaust air. This primarily applies if there is some form of refrigeration machine in the house. Moisture control The unit has a built-in automatic function which limits moisture recovery by the rotary heat exchanger at high levels of humidity in the indoor air. How to adjust setpoint values and set energy modes, etc. See the instructions for installation and service engineers under the heading djustment, commissioning, p.13. NOTE! The electric post-heating device only operates if the impeller is working. Fläkt Woods GB 9295 2013.06 3 We reserve the right to make changes.

Managing the control panel functions RDKS has a built-in control unit which controls the operation of the two high-efficiency fans, the rotary heat exchanger and the electric batteries. The fan speed is selected via the external control panel RDKZ-41 (accessory), which is fitted in a suitable location, for instance on a wall or set into a wall box. Figure 1. Control panel RDKZ-41 with connection cable. The user can select between the following operating modes: "WY" "HOME" "FORCED" is used when there is nobody home for a longer period to save energy is used for normal ventilation flow is used when there is a greater need for ventilation (it will automatically revert after 120 minutes). HOME mode When the arrow button is pressed so that the diode lights up in the HOME symbol, see figure 2, the operating mode has changed to HOME mode, that is, normal ventilation, which means a nominal ventilation flow is achieved. FORCED mode When the arrow button is pressed so that the diode lights up in the FORCED symbol, see figure 2, the operating mode changes to forced mode, that is, additional ventilation to achieve an extra high ventilation flow. The duration of the forced mode is 120 minutes, after which it reverts to the previous mode. If forced ventilation is required for a shorter period, the mode can be cancelled manually by pressing the arrow button and choosing the HOME or WY mode. Unit with cooker hood When the damper in the hood is opened, the fans will operate in forced mode as long as the damper is open. When the damper is closed, the fans revert to their previous speed. FORCED WY/HOME WY HOME rrow button (to change operating mode) FORCED Figure 3. Forced via cooker hood CPDJ. Figure 2. Control panel (RDKZ-41) operating modes. WY mode When the arrow button is pressed so that the diode lights up in the WY symbol, see figure 2, the operating mode has changed to WY mode, that is, a basic ventilation flow will be maintained in the house when there is nobody at home for a longer period. Fläkt Woods GB 9295 2013.06 4 We reserve the right to make changes.

Control panel - overview of symbols and functions Symbols for normal use Filter alarm WY HOME FORCED Resetting of filter alarm (press for at least 10 seconds). Figure 4. rrow button (to change operating mode) Symbol Operating mode Flashing alarm symbol indicates filter alarm Unit operating in WY mode Unit operating in HOME mode Unit operating in FORCED mode for 120 minutes Change operating modes between: WY, HOME or FORCED Go to the display mode for temperature setpoint value (desired value) min. 10 sec Press*for a minimum of 10 seconds to reset the filter alarm. Fläkt Woods GB 9295 2013.06 5 We reserve the right to make changes.

Maintenance and cleaning of heat exchanger and fans General Fans, filters and rotary heat exchangers are very important for the function and economic running of the unit. it is therefore important that these are kept clean and in good condition. We recommend a general check-up in connection with filter replacement every 6 months. For safety reasons, general caution should be observed during maintenance of the unit. If necessary, use protective gloves. Figure 8. The heat exchanger is vacuum cleaned from both sides. Cleaning the fans Note that the fans must not be cleaned with water or other fluids but must only be vacuumed or brushed. Figure 5. Before cleaning the heat exchanger and fans, etc., the unit should always have the power disconnected. Figure 6. The front cover of the unit, if there is one, is dismantled, the screws on the door are unscrewed and the door is opened. Cleaning of the heat exchanger Check that the surface of the impeller is not covered in dust. Clean by using a vacuum cleaner or by blowing through using compressed air. If vacuum cleaning is not sufficient, apply a grease-dissolving fluid using a handspray pump and then blow clean using compressed air. Note! cetone or a similar solvent must not be used. Because of wear and tear, the drive belt and seals may need replacing. Check these for damage and replace if necessary. For designations, see the spare parts list on page 17. Figure 9. The fan is removed from the unit. The electrical connection is disconnected. Figure 10. The impeller is removed from the fan housing by unscrewing the screws on the side of the fan housing. Figure 11. Clean the impeller housing and the fan blades with a brush. NOTE! Do not damage any impeller housing balancers Figure 7. The heat exchanger package is removed from the unit. The electrical connection to the impeller motor is disconnected. NOTE! Ensure that no cables are trapped during reassembly. Fläkt Woods GB 9295 2013.06 6 We reserve the right to make changes.

Filter alarm, filter replacement Filter alarm The alarm light on the control panel flashes. Read more about filter replacement below. Filter replacement The filters for supply and exhaust air should normally be replaced every six months. In dirty areas more frequent filter changes may be required. built-in timer is normally set to provide a reminder about filter replacement after six months. The steps below show how to replace the filter. 3. Pull out filters and B, see figure 14. B Figure 14. The position of the filters in the unit (the filters may be of a different type than the one shown in the picture). Figure 12. Pull out the power plug. 1. Disconnect the power to the unit, see figure 12. 2. Open the unit door by unscrewing the two screws on the front, see figure 13. 4. Install new filters. 5. Close the unit door 6. Put the plug in the wall socket. 7. fter replacing the filter, the timer should be reset by pressing the * button on the control panel for a minimum of 10 seconds (see page 5). Figure 13. Opening the unit door. Fläkt Woods GB 9295 2013.06 7 We reserve the right to make changes.

Installation - Dimensions, definitions Dimensions 240 203 115 70 203 240 70 115 183 265 285 78 F T U 83 188 188 380 83 U T F 78 183 265 285 595 RDKS-1 Supply air and outdoor air to the right T = Supply air F = Exhaust air U = Outdoor air = Extract air 595 RDKS-2 Supply air and outdoor air to the left Duct definitions F K U T Figure 15. Duct definitions T = Supply air F = Exhaust air U = Outdoor air = Extract air K = Exhaust air device in kitchen (not above cooker). Ducts U and F should be increased to Ø125 mm as soon as feasible after the unit. Fläkt Woods GB 9295 2013.06 8 We reserve the right to make changes.

Duct connection, insulation of ducts Note! During installation, the instructions relating to unit installation and duct insulation must be adhered to without deviation. Otherwise, there is a risk of condensation and moisture resulting in major damage. Duct connection Extract air from the unit must only be connected to a ventilation duct intended for the purpose. Connection must not be made to a smoke or gas flue. In the case of exhaust air ventilation in premises where a smoke or gas flue is used (for instance, an open fireplace or heating stove), an adequate supply air flow must be provided. kitchen flue must be provided in accordance with applicable regulations. We recommend a separate exhaust air device in the kitchen as well as an airtight forced air damper to ensure heat recovery from the air in the kitchen. Insulation of ducts In order for the installation of RDKS to be effective, it is very important that the installation of the ventilation ducts in the unit, as well as the installation of ducts through external walls containing insulation and vapour barriers, external roofs and joists, is executed in a professional manner. Otherwise there is a risk of condensation, resulting in damage due to moisture. During replacement of older units, it is also necessary to ensure the quality of defective ducts and duct insulation. Supply air ducts (T) and exhaust air ducts F), that is, ducts filled with warm air, which are located in unheated spaces, must be insulated. The insulation should be applied externally and have a wind-proof surface layer. Supply air ducts (U) and extract air ducts (), that is, ducts filled with cold air, which are located inside the building's vapour barrier, must be insulated and have a diffusion-proof (moisture-proof) surface layer. Given the high degree of heat recovery achieved by RDKS, the extract air too gets very cold and must be thermally insulated. Ducts which run alongside each other must also have a common vapour barrier. For designations of the various ducts, please see figure 15 on the previous page. The wall on which the unit will be mounted must be well insulated. Ducts in warm spaces (indoors) The temperature of the air in the duct is above +10 C Supply air ducts (T) Exhaust air ducts (F) No insulation Ducts in cold spaces Supply air duct (T) Outdoor air duct U) Exhaust air duct F) Extract air duct ) Moisture barrier Ducts in loose wool Roof truss Recommended insulation and vapour barriers for different types of ducting The temperature of the air in the duct is below +10 C Outdoor air duct (U) Extract air duct () Supply air duct (T) Exhaust air duct (F) Fire insulated 30 mm mineral wool mat with moisture-proof surface layer oisture barrier Type of ducting pproved material Duct in a warm space Vapour Duct in a cold space Vapour and location Insulation barrier Insulation barrier The sheet must be bound tightly to the duct. Min thickness 10 cm. Moisture barrier Moisture barrier Extract air (flue) In kitchen Metal, accessible for inspection rmaflex F3 19 mm Yes Between joists Metal Fire protection E15, Yes Fire-insulated E15, Only inside the buildings and in the attic mesh mat 30 mm mesh mat 50 mm vapour barrier Extract air (no flue) Metal Mineral wool 25 mm Yes Between joists Metal Mineral wool 30 mm Yes Mineral wool 30 mm Yes and in the attic From tumble dryer Metal Mineral wool 30 mm No Mineral wool 100 mm No Outdoor air In kitchen Metal, accessible for inspection rmaflex F3 19 mm Yes Between joists Metal Mineral wool 60 mm Yes Inside the buildings vapour barrier Only inside the buildings in the attic Mineral wool 60 mm, and vapour barrier Supply air Metal No requirements Mineral wool minimum Exhaust air 80 mm or equivalent. No ll figures in this table are recommended values which apply in central Sweden. Please check for local variations. Fläkt Woods GB 9295 2013.06 9 We reserve the right to make changes.

Installation of unit with accessories If the unit is not installed immediately after delivery, the unit shall be stored in a protected place under cover and in its original packaging. The unit is intended for installation indoors in a warm space and must not be used without being connected to ducts. We recommend that the unit be lifted into place by two people wearing protective gloves. 1 3 500 X 1400*mm x 2 25 50 X mm * To be adapted according to existing cabinet fittings 2 4 2 600 RDKS must always be connected to an earthed socket Gips max 200 Mineralull 1 1400* * To be adapted according to existing cabinet fittings Fläkt Woods GB 9295 2013.06 10 We reserve the right to make changes.

Installation of unit with accessories, cont. 5 6 500 mm 2 1 RDKS RDKG 7 8 Fläkt Woods GB 9295 2013.06 11 We reserve the right to make changes.

Mode LED Param. Heat recovery unit RDKS Installation of unit with accessories, cont. 9 Installation of front cover RDKZ-14-b-0-c-d-1 (accessory) 2 Cabinet depth 375 mm Cabinet depth 350 mm Cabinet depth 300 mm 1 3 4 The brackets for the front cover can be bent or cut along a perforated line to fit different cupboard depths. They are then attached to the front cover using a blind-rivet tool. 10 Installation of front cover with extension unit towards the ceiling RDKZ-14-b-1-d-1 (accessory) Ceiling/Wall Screw Side panel Front panel 11 Installation of front cover RDKZ-14 with flyshelf above the kitchen cabinets Over-cabinet panel (not included in delivery) Unit hatch (15 mm) RDKR Section 90 1) Cover panel Max 593 350 593 600 Spacer Kitchen cabinet Cover panel (included in RDKZ-14-b-0) Over-cabinet panel Front cover RDKZ-14 Overlap ca 10 mm n extension unit for the front cover is available to order so that the front cover reaches all the way up to the ceiling, see figure above. It is placed inside the front cover, slightly overlapping. The height is 305 mm. 1) The measurement 90 applies to the distance from the outside of the unit front cover to the outer edge of the curved cover plate. Fläkt Woods GB 9295 2013.06 12 We reserve the right to make changes.

djustment, commissioning Functions Fan speeds can be adjusted independently of each other ll speeds in both fans are adjustable. Normally, only normal speed is required, HOME mode, adjusted to meet the design ventilation rates. Users can choose between WY mode, HOME mode for normal ventilation or FORCED mode when there is an increased need for ventilation. Forced ventilation reverts to the previous mode after 120 minutes. In addition, a further forced flow is available by using the knobs on the cooker hood. This operating mode is adjusted separately. The controller card regulates the rotary heat exchanger and electric batteries to achieve the required supply air temperature. The heaters and fans have built-in protection devices to prevent overheating. The controller card also regulates automatic defrosting and, through a built-in timer (6 months), indicates when it is time to replace the air filters. Facility to regulate air flows from external devices, for instance cooker hood. When the cooker hood damper is open, the fan speeds are adjusted to forced flow. djustment of flow and temperature djustment of air flow and temperature should only be carried out by an authorised person. The reason for this is regulations and is due to the fact that alterations may increase energy consumption or interfere with the air flow and pressure balance in the building, thereby seriously damaging building components if the adjustment is performed incorrectly. General The unit is equipped with 4 measurement points in the unit door inside the front cover, see figure 16 below. Measuring the pressure difference, p m in Pa over the impeller gives the total supply air and exhaust air flows. The air flow q (l/s) is determined using the following formula: q = 0.73 x p m If the total flows in the preset mode do not conform with the desired flows, they can be adjusted. For more information, see pp. 15-16. Planning advice In a rotary heat exchanger it is not possible to completely eliminate leakage between supply air and exhaust air. ir leakage at the seals is minimised by ensuring that the pressure difference between the supply air and exhaust air ducts is as small as possible. The pressure difference between the supply air ducts and exhaust air ducts on both sides of the exchanger should be different depending on whether it is a right-hand or left-hand design, see figure 16 below. If required, a shut-off damper should be installed on the exhaust air side to achieve this. C Supply air on the right-hand side of the unit B D Supply air on the left-hand side of the unit Supply air flow D - B C - Exhaust air flow C - D - B Pressure difference B > > B D > C C > D Figure 16. Measurement points for measuring differential pressure and pressure balance over the heat exchanger. NOTE! Flow deviations of up to 25% may occur using this method of measuring on a unit with rotary heat exchanger. Used as a flow indication, but control measurement to be performed in the supply and exhaust air devices. Fläkt Woods GB 9295 2013.06 13 We reserve the right to make changes.

Electrical connection and wiring diagram Right-hand version (RDKS-1) Electrical connection and wiring diagram for RDKS-1 - right-hand version. Diagram for RDKS-2 - left-hand version is not shown. However, this is a mirror image of the one shown. L N PE Door switch HMI 2 Modbus RS485 B GND Voltage control card 230 V 1 N 2 L 3 N 4 L 5 N 6 L 7 N 8 L 70.69.68 67.66.65.64 USB 51 50 49 48 47 46 HMI 0 Temperature Temperature outdoor air Temperature supply air Moisture sensor supply air B B Moisture sensor exhaust air 27 28 37 38 Cooker hood forced ventilation N L N L N L L N Tacho 0 V +10 V L N 0 V +10 V L N Post-Heater Pre-Heater Rotary Heat Exchanger Cooker hood Exhaust air fan Supply air fan Fläkt Woods GB 9295 2013.06 14 We reserve the right to make changes.

djustment of fan speeds and temperature setpoint value Using the control panel for adjustments The fan speeds in the modes HOME, WY, FORCED and cooker hood mode as well as the temperature setpoint value are adjusted using the following steps on the control panel: 1. Enter Display mode by pressing both * and # simultaneously for approx. 3 seconds. + 2. In Display mode the parameter values can be read by counting the number of flashes in the WY, HOME and FORCED lights. The parameter number flashes in the alarm symbol. See List of parameters on page 16. Switch between parameters using * (reduce parameter number) and # (increase parameter number). Example: To read the HOME speed of the exhaust air fan, use * and # to go to parameter number 2. When parameter 2 is selected, the alarm light should repeatedly flash red 2 times, followed by a short pause. 3. To change the parameter value, press * and # simultaneously again for approximately 3 seconds until the alarm light emits a steady glow. 4. Using * (reduce value) and # (increase value), the parameter value can now be adjusted. The parameter value is illustrated by the number of flashes in the green lights for WY (hundreds), HOME (tens) and FORCED (units). Example: To increase the value of the HOME speed of the exhaust air from 55% to 65%, press # 10 times. Then confirm that the HOME symbol flashes 6 times, followed by the FORCED symbol flashing 5 times. + Increase Reduce Increase Reduce 5. Confirm the changes by pressing the RROW button. 6. The above procedure is repeated for all fan operating modes, as per the table List of parameters. The temperature setpoint value is set using the above procedure using parameter number 1. Changing the temperature setpoint value To change the set temperature setpoint value, use either * or # in Operating mode. By pressing on one of these buttons the temperature setpoint value changes. The value is shown as flashes in the WY, HOME and FORCED symbols as per the table on page 16 - djustment mode. * reduces the temperature setpoint value by 1 # increases the temperature setpoint value by 1 Fläkt Woods GB 9295 2013.06 15 We reserve the right to make changes.

Control panel and List of parameters Control panel Symbol Operating mode Read mode djustment mode Flashing alarm symbol indicates filter alarm Number of flashes on the alarm symbol indicates which parameter is shown, see List of parameters below When the lamp stays lit, the panel is in programming mode and the parameter value can be changed Unit operating in WY mode Flashing indicates value in hundreds Flashing indicates value in hundreds Unit operating in HOME mode Flashing indicates value in tens Flashing indicates value in tens Unit operating in FORCED mode for 120 minutes Flashing indicates value in units Flashing indicates value in units Change operating mode between; WY, HOME or FORCED Revert to operating mode Confirm parameter value and revert to operating mode or To set the adjustment mode for temperature setpoint value * reduces the temperature setpoint value by 1. # increases the temperature setpoint value by 1 + min. 10 sec Press * and # simultaneously for around 3 seconds to get the Display mode For the selected parameter, press * and # simultaneously for around 3 seconds to enter the djustment mode for the parameter in question List of parameters Parameter No Function 1 Temperature setpoint value 2 Fan setpoint value exhaust air fan, HOME mode 3 Fan setpoint value exhaust air fan WY mode 4 Fan setpoint value FORCED mode 5 Fan setpoint value exhaust air fan. Forced mode via cooker hood 6 Fan setpoint value supply air fan HOME mode 7 Fan setpoint value supply air fan WY mode 8 Fan setpoint value supply air fan FORCED mode 9 Fan setpoint value supply air fan. Forced mode via cooker hood Fläkt Woods GB 9295 2013.06 16 We reserve the right to make changes.

Spare parts Right-hand version (RDKS-1) Left-hand version (RDKS-2) not shown. 2 1 7 11 8 10 3 9 12 6 4 5 RDKZ-14 If the connection cable is damaged, it must be replaced by the manufacturer, an authorised service company or similar qualified personnel in order to avoid danger. Pos. Designation Description Used in No Remark 1 RDKR-99-01-1 Supply air fan, right-hand unit RDKS-1 1 1 RDKR-99-01-2 Supply air fan, left-hand unit RDKS-2 1 2 RDKR-99-02-1 Exhaust air fan, right-hand unit RDKS-1 1 2 RDKR-99-02-2 Exhaust air fan,left-hand unit RDKS-2 1 3 RDKR-99-03 Electric battery (pre-heating and post-heating) RDKS-1 /RDKS-2 1 4 RDKS-99-02 Impeller, complete RDKS-1 /RDKS-2 1 5 RDKR-99-08 Drive belt, impeller RDKS-1 /RDKS-2 5 6 RDKS-99-01 impeller motor RDKS-1 /RDKS-2 1 7 RDKS 99-03 Controller card RDKS-1 /RDKS-2-a-b-c-d-1 1 8 RDKG-99-14 Filter pad G3 (1) RDKS-1 /RDKS-2 1 9 RDKG-99-15 Bag filter M5 (1) RDKS-1 /RDKS-2 1 9 RDKG-99-16 Bag filter F7 (1) RDKS-1 /RDKS-2 1 10 RDKG-99-22 Filter set G3, without frame RDKS-1 /RDKS-2 10 11 RDKS-99-04 Temperature sensor RDKS-1.../RDKS-2... 3 12 RDKR-99-14 Brush strip RDKS-1.../RDKS-2... 1 Fläkt Woods GB 9295 2013.06 17 We reserve the right to make changes.

Installation of control panel RDKZ-41! The power must be disconnected during installation/ dismantling of control panel RDKZ-41 1 3 2 4 6 7 CLICK 8 5 9 CJB/RDKR/RDKS/RDR/RDKG/RDB/RDE CJB/RDKG/RDKS/ RDB/RDE RDKR/RDR FWG_Housing_RDKZ-41 Instructions and maintenance_un_201111_8546 2 1 CJB/RDKR/RDKS/RDR/ RDKG/RDB/RDE 3 = Bygel Jumper 5 back rear 4 CLICK Fläkt Woods GB 9295 2013.06 18 We reserve the right to make changes.

EU confirmation of conformity Bilaga II Försäkran om maskinens överenstämmelse med EG:s Maskindirektiv 2006/42/EG, EG:s EMC Direktiv 2004/108/EG, EG:s Lågspänningsdirektiv LVD 2006/95/EG Tillverkaren Fläkt Woods B Gesällgatan 17 745 39 Enköping Försäkrar härmed under eget ansvar att: Produkten RDKS vilken levereras med komplett styrsystem överenstämmer med Och uppfyller de grundläggande hälso- och säkerhetskrav på konstruktion och tillverkning av maskiner och säkerhetskomponenter som ställs i rubricerade direktiv under förutsättning att de installeras i anläggning enligt medlevererad instruktion. Om ändringar görs på produkten blir denna försäkran ogiltig. Maskinen är konstruerad och tillverkad i enlighet med följande standarder: Maskinsäkerhet EN ISO 12100-1, EN ISO 12100-2 Elsäkerhet EN 60204-1, 60335-1,-2 Elektromagnetisk kompabilitet EN 61000-6-1,-3 Skyddsavstånd EN 13857:2008 Strålning (människa/ maskin) EN 50366:003 För produkten har riskanalys upprättats enligt krav i Maskindirektivet. Behörig tt sammanställa teknisk dokumentation: nn-sofie ndersson Gesällgatan 17 745 39 Enköping Försäkran gäller endast om installation av aggregatet skett enligt Fläkt Woods instruktioner och förutsatt att inga ändringar gjorts på aggregatet Enköping 2013-01-01 Fläkt Woods B Postal ddress Street ddress Telephone Telefax Reg. no: Fläkt Woods B Fläktgatan 1 Nat 036-19 30 00 Nat 036-19 31 40 556239-2463 S-551 84 Jönköping Int +46 36 19 30 00 Int +46 36 19 31 40 Reg. office: Sweden Jönköping Fläkt Woods GB 9295 2013.06 19 We reserve the right to make changes.

Fläkt Woods B, 551 84 Jönköping FWG_Housing_RDKS Technical instruction_201306_gb 9295 Tel. +46 (0)36-19 30 00 Fax. +46 (0)36-19 36 20 Website: www.flaktwoods.se