INSTALLATION INSTRUCTIONS MEL2 TM SERIES

Similar documents
HIGH LUMINOUS EFFICIENCY

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

DHL-LP-LED Low Profile LED Linear High/Low Bay

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Product Specifications

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

DIMMING 0-10V Continuous

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

DHL-LP-LED Low Profile LED Linear High/Low Bay

FPLHB - Fidelux Premier Linear Highbay

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

GLED INSTALLATION INSTRUCTIONS

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

LED HIGH BAY LINEAR ECO SERIES

110 lm w STANDARD SERIES

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

GLED INSTALLATION INSTRUCTIONS

North America Version / Dimming Function. Introduction

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Important Safety Instructions. Important Safety Instructions

Premium. Universal LED Vapor Tight T20G. Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

LED Seamless VaporProof Fixture Installation Instruction

DESIGNED SPECIFICALLY FOR QUICK AND EASY WATERPROOF INSTALLATION.

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

LED Shoplight fixture

MaxLite LED High Bay Fixtures

LHBXD LED Linear High Bay

IP65 High Bay Dual Sense Sensor

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

Tri-level Control HF Sensor

Tri-level Control HF Sensor

Installation Instructions. Tersen. Ratio Canopy 1.5

Tri-level Control HF Sensor

LED IMPORTANT SAFETY INSTRUCTIONS

LPCMPIRM65 & LPCMPIRDSI65

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

False Ceiling HF Sensors

Built-in HF Sensor for High Bay

LED IMPORTANT SAFETY INSTRUCTIONS

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Specifications

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

LED HIGH BAY LINEAR HL SERIES

IP65 High Bay Dual Sense Sensor

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

HIGH POWER LED RETROFIT MODULE

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

1. Basic safety information 3 2. Proper use 3

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Daylight harvest function to regulate light output for maintaining required lux level

MSSD- microwave sensor, Factory Set standard 3 minute delay 50% step dimming. (additional options 20% / 50%, delay from 1 to 20 minutes)

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Integrated SensorDIM LED Driver Daylight Monitoring Version

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

Operating Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

Alliance 4 - ALI4 LED 4 Linear High Bay


Sensors Explained AUTOMATION

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

Data sheet. Function description. Benefits

Parking Garage. Lighting & Control Solutions SLGUS.COM

Evolve LED Garage Light

LED Tri-proof Light. LED Tri-proof Light SPEC. Microwave Motion Sensor. Option: Remote control. Suitable for a variety of scenes

LED IMPORTANT SAFETY INSTRUCTIONS

BayMAX HL Series LED Linear High Bays Presented by: Nick Latwis. November 30, 2016

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

MaxLite LED Round Pendant Highbay Series

SDL4 LED Strip Diffused Lens

Dimensions (111mm) (111mm) 3 (76mm)

BAS SDL8' LED Strip Diffused Lens

GL BAL GLEDAL 150W B L A Z E AISL E L IGHT SPECIFICATION SHE ET OPTICAL SPECS ELECTRICAL SPECS CERTIFICATIONS OTHER DETAILS DIMENSIONS BEAM ANGLES

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

CEILING FAN OWNER'S MANUAL

LED IMPORTANT SAFETY INSTRUCTIONS

Tri-level Control Sensor

IMPORTANT SAFETY INSTRUCTIONS:

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

LED ROUND MINI PANELS

Premium Version Tri-level Dimming Control

Automatic switch attachment Standard Installation Instructions

CoreLine Waterproof the clear choice for LED

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

FR-A180 FR-A360. Occupancy detector. Use

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

CoolTouch TM control system

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

30-YEAR LIMITED WARRANTY

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

LED IMPORTANT SAFETY INSTRUCTIONS

Transcription:

W E S T 13100 Alondra Blvd., #106 Cerritos, CA 90703 E A S T 348 Turnpike St Canton, MA 02021 Tel: 1-844-865-5444 (1.844.VM5.LIGHT) Fax: 1-844-865-5444 INSTALLATION INSTRUCTIONS MEL2 TM SERIES LED HIGH BAY READ BEFORE INSTALLATION SAVE THESE INSTRUCTIONS FOR FUTURE USE These instructions do not purport to cover all details or variationsin luminaire orprovide for every possible contingency tobe met in connection with installation, operationormaintenance. For more details orspecial problems outside of this manual, please contact VM5 Lighting Solutions. Warning CAUTION FOR ELECTRIC SHOCK/RISK OF BURN/PROPER INSTALLATION To be installed by a licensed electrician only. Please allow the luminaire to cool down prior to performing maintenance. Please wear safety glasses and other needed protectiveequipmentduringtheprocess of installation and maintenance. 1. GENERAL Please read this document before installation and operation to avoid injury. This luminaire is for both indoor and outdoor applications. Please donot use in poorly ventilated or high temperature area. Please follow the below for proper installation and maintenance. 2. UNPACKING MHB-XX-100-YY-UNV; MHB-XX-150-YY-UNV; MHB-XX-200-YY-UNV; Model # s MHB-XX-100-YY-347/480 MHB-XX-150-YY-347/480 MHB-XX-200-YY-347/480 Class I IP66 SYSTEM 120-277v/ 347-480v 50/60Hz 3. APPLICATION NOTICE PLEASE APPLY THE PRODUCT ACCORDING TO THE FOLLOWING STATEMENT LED High Bay used for indoor and outdoor lighting and can beinstalled in workshops, warehouses, underground parking areas, toll stations, gas stations, supermarkets, exhibition halls, gymnasiums, and so on. 4. INSTALLATION The luminaire has been properly packed to avoid damage during transit. Inspect the luminaire to confirm there is no damage. Do not install a damaged luminaire or damaged luminaire components. This carton consists of: Luminaire Product manual WARNING Ensure this manual is provided to the installers and users Always switch off the power supply before commencing work Wrong installation may lead to falling; please follow the manual Do not touch the light while it is energized Please change any damaged covers The High Bay fixture is threaded with 3/4 NPT. It can offer several mountingoptions. Please choose propermounting typeand optic lens degree for your application.

3/4 Hook mounting: 1. Feed the power cord through the hook. 2. Thread hook into the driver housing. 3. Mount high bay fixture with the hook to a sturdy ceiling structure, directly or by chain. 4. Connect power cord to supply wires inside a junction box using approved wire connectors. 5. Secure the safety cable to ceiling structureto avoid fixturefalling down. 6. Tighten hook with set - screw. 3/4 Hook Power cord Set screw Chain Safety cable 3/4 Pendant mounting: (3/4 pendantnotsuppliedunless specified otherwise) 1. Choose pendant length and feed power cord through pendant. If longer cord is required, replace the cord with the appropriate length wires. 2. Screw the pendant to the driver housing 3. Connect supply wires to fixture cord inside a junction box using approved wire connectors 4. Secure the safety cable to ceiling structureto avoid fixturefalling down 5. Tighten pendantwith set - screw Power cord Set screw 3/4 Pendant Safety cable Bracket mounting: (Bracket is notprovided unless specified otherwise) 1. Bracket is pre-installed on fixtureat factory. 2. Mount fixture to a sturdy wall or ceiling structure. 3. Adjust angle through bracket according to application. 4. Connect power cord tosupply wires inside a junction box using approved wire connectors. 5. Secure the safety cable to wall or ceiling structure to avoid fixture falling down. Power cord Bracket 1 Safety cable Bracket 2 Optic lens degree options: 1. 100 degree (wide beam) 2. 60 degree (narrow beam) 3. 60x100 degree (aisle beam) Aisle optic application: Wide beam and narrow beam application: Warehouse, Industrial,Agricultural, Outdoor,etc. Aisle beam application: The aisle optic is specially designed to illuminate aisles in warehouse and industrialapplications The lighting direction is parallel to the driver housing

5.WIRE GUARD INSTALLATION Screw Wire guard Secure plate Step 1: Putthe wire guard on the center of the light cavity, spinning thewire guard position toavoid blocking LEDs Step 2: Insert the screw through the heat fin gap, then secure the wire guard 6. SENSOR INSTALLATION AND SETTINGS 120-277v microwave motionsensor Balance plate Sensor bracket 1 Sensor swing bracket 2 Sensor safety cover Detecting probe

Step 1: Secure the balance plate to the fixtureby supplied screws Note: Fixture is pre-punched at the back. Balance plate is used for hook and chain mounting solution. Step 2: Install the sensor bracket 1 on the fixture Step 3: Install the sensor swing bracket 2 to bracket 1 Step 4: Install sensor on bracket 1 and detecting probe on bracket 2, then do the wiring Step 5: Install thesensor safetycover Notes: Detection zone: Max. (DxH):16m x 8m Microwave Motion Sensor Settings Standby period Standby dimming level Daylight threshold Hold time Detection area Daylight sensor Detection area Detection area can be reduced by selecting the combination on the DIP switches to precisely fit each application Hold time Refers to the time period the lamp remains at 100% illumination after no motion detected Stand-by period Refers to the time period the lamp remains at a low light level before it is completely switched off in the long absence of motion. When set to Disable mode, the low lightis maintained until motion is detected

Stand-by dimming level The low light you would like to have after hold time in the long absence of motion Daylight sensor The sensor can be set to only allow the lamp to illuminate below a defined ambientbrightness threshold.when set to Disable mode, the daylight will switch on the lamp when motion is detected regardless of ambientlight Level 50lux, 30lux: twilight operation,10lux, 5lux: darknessoperation only. Note that daylight sensor is active only when lamp is totally switched off 347-480v occupancy sensor (PIR sensor) Balance plate L type bracket Mounting arm Sensor Step 1: Secure the balance plate to the fixtureby supplied screws Note: Fixture is pre-punched at the back. Balance plate is used for hook and chain mounting solution. Step 2: Install the sensor toit s mounting arm Step 3: Install themountingarmtothe L typebracket Step 4: Install the L type bracket on the fixture Notes: Detection zone: Max. (DxH):13m x 12m

Occ Sensor Settings Light level The light level feature allows lighting to remain OFF duringdaylight, regardless of occupancy. Daytimeoperation is at 200footcandles(factory Setting). Nighttime operation is at 2 footcandles Light level teach mode The light level teach mode reads the ambient light level in thespace andselectsthis amountfor the light level setting. ٠Turn thelight level setting to ٠After 10 seconds, the value ofthe ambient brightness is saved ٠This value is also available after a power failure ifthe potentiometer isset to teach mode at power up. Time delay Time delay is the period of time lights remain on after the last detection. Adjustment ranges from 15 secondsto 30 minutes.

7. PRODUCT SPECIFICATIONS Weatherproof ratio: IP66 Anti-shock Protection rate:class I Operation voltage :120-277Vac / 347-480Vac (50/60Hz) Declared wattage :110W / 145W / 210W Standard Kelvin color: 4000K / 5000K Light efficiency : upto110 lm/w Power factor: >0.95 THD: <10% Operation temperature:-25 - +55 Lens type: Aisle beam ( 60x100 ), Wide beam ( 100 ), Narrow beam ( 60 ) Product measurement 110w 120-277v: MHB-XX-100-YY-UNV 145w 120-277v: MHB-XX-150-YY-UNV 110w 347-480v: MHB-XX-100-YY-347/480 145w 347-480v: MHB-XX-150-YY-347/480 210w 120-277v: MHB-XX-200-YY-UNV 210w 347-480v: MHB-XX-200-YY-347/480 8. MAINTENANCE Warning! Be cautious of electric shock and burns. Any operation should be conducted after power is turned off and fixture has cooled down. 1. The safety of the product is not guaranteed unless all procedures are followed according to the vendor s manual.be aware ofall improper installation to avoid electric shock, fire or any other possible accidents. 2. Avoid the product being used in a corrosive, explosive, flammable or dustsurrounded environment. 3. Avoid violent vibration and impact. 4. Turn off the power to prevent electric shock and cool off the light for 15 minutes minimum before maintaining. In order to keep the transmittance of the cover, a regular cleaning is required upon user s condition. Clean cover and fixture with non-abrasive cleaning solution.

Notes:......