REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Similar documents
Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 1 INTRODUCTION

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

A Comparison Between Refrigerants Used In Air Conditioning

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

DEEPAK PALIWAL, S.P.S.RAJPUT

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

International Journal of Advance Engineering and Research Development

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

CHAPTER 1 INTRODUCTION

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Chapter 2. Alternatives to HCFCs and their Characteristics

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Study of R161 Refrigerant for Residential Airconditioning

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

η second law = Second law efficiency

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Chapter 10. Refrigeration and Heat Pump Systems

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Oyelami S., Bolaji B. O.

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

ISSN: [Sachuthananthan * et al., 5(10): October, 2016] Impact Factor: 4.116

Department of MCE, Islamic University of Technology 2. Abstract

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Design of LPG Refrigeration System

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Evaluation of HCFC Alternative Refrigerants

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Design & Fabrication of Hybrid Cooler

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

Thermodynamics I. Refrigeration and Heat Pump Cycles

The Problem of Counterfeit Refrigerants

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

ADVANCES in NATURAL and APPLIED SCIENCES

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

THE USE OF HYDROCARBONS PROPANE AND ISOBUTANE IN REFRIGERATION SYSTEMS

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

HFCs or the Old Refrigerants - what is the best Choice?

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Low GWP Refrigerants for Air Conditioning Applications

Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research

Transcription:

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER Alka Bani Agrawal* and A.C.Tiwari 1 Department of Mechanical Engineering, R.G.T.U., Bhopal M. P. (INDIA) *E-mail : alk_agr@yahoo.co.in Received January 20,2009 Accepted April 14, 2009 ABSTRACT India is a leading developing country with flourishing refrigeration and air conditioning industry. Recently it has achieved the distinction of becoming the largest producer of milk in the world. Instant milk chilling units are used in dairy sector for chilling the milk to 4 C just after milking so that it can be preserved till further processing. Refrigerant Chloroflurocarbon12 is mainly used in milk chillers and as per Montreal Protocol, all Ozone depleting substances like R12 are to be phased out of use before 2010. This paper presents performance analysis of refrigeration system of milk chiller for selecting a eco-friendly alternative to replace R12 in milk chillers. KeyWords : CFC1 12, Ozone Layer Depletion, Instant Milk Chiller, Eco-friendly refrigerant INTRODUCTION The world has witnessed rapid industrialization in the last two decades, which has resulted in improved quality of life of people. The economic benefits have reached to the lowest level with all enjoying long life full of comforts. But the wealth came at the cost of environment and now we are facing two big environmental problems of ozone layer depletion and global warming.the problem of ozone depletion came into light in 1974 when Roland and Molina accidentally discovered it. After various studies, it was confirmed that mainly Chloroflurocarbons (CFCs) are responsible for the destruction of protective ozone molecules that absorb the ultra violet radiation of sun and protect the earth from it harmful effects. After much discussions and deliberations the Montreal Protocol was signed under the UNEP for phasing out the * Author for correspondence use of ozone depleting CFCs which are used in refrigeration and air-conditioning equipment. As per this protocol, the developed countries have stopped the production and use of CFC in 1999 and now it is the turn of developing countries to cease the use of CFC by 2010 1. Objective India is a leading developing country that has a flourishing refrigeration and air conditioning industry. At present it consumes more than 1990 MT of CFC substances like R11, R12 in various commercial and industrial refrigeration and air-conditioning equipment which will be required to be phased out by 2010. One of the important refrigeration unit is the Instant Milk Chilling Unit used by dairy sector for cooling the milk collected at collection centers to keep it fresh before dispatching it in insulated tanks to big dairy plants for further processing and packing. 1246

Bhopal Dugdh Sangh has 13 chilling centers where milk is chilled to 4 C with the help of Milk chillers before dispatching it daily in insulated tanks to big plant for further processing 2. Milk chillers of up to 5000 LPD capacity use chloroflurocarbon (CFC are better known commercially as Freons) refrigerant R-12 in their vapour compression refrigeration systems. 9 out of 13 chilling centers of Bhopal dairy use Freon 12 and constitute more than 25 % of the total installed milk chilling capacity and needed to be replaced There are two options for finding a solution to this problem. 1. To phase out these plants and install new ones which work on Ecofriendly refrigerants. This will involve huge investment as a milkchilling unit of 4000 LPD capacity costs around Rs 6, 00, 000; therefore a total investment of Rs 50, 00,000 will be needed for the new plants for the 9 chilling centers. 2. By changing the R12 refrigerant by an Eco-friendly refrigerant, the existing chilling plants can be continuously used even after 2010. Most of the 9 chilling plants were installed in 90s and as they have a long life of 15 to 20 years, retrofitting the plants to a suitable refrigerant is the most desired solution. Retrofitting is changing the harmful R12 by a suitable drop in refrigerant with minimum modification in the system. This can be done at a fraction of the cost of the plant 3. 1247 MATERIAL AND METHODS Alternative Eco-friendly Refrigerants Till their phase out, due to ozone depleting chlorine atom, as a result of the Montreal Protocol the CFC refrigerants R12 was the main stay of the refrigeration industry. Initially it began to be replaced by HCFC (Hydrochloroflurocarbons) refrigerants, which contain small no of chlorine but equally good thermodynamic, physical and safety properties. But the Copenhagen revision of the Montreal Protocol has also sealed the fate of HCFC refrigerants due to their considerable ozone depletion and global warming potential. But HCFC refrigerants are proposed to be phased out in developed countries by 2030 and a further grace period of 10 years is given for developed countries. Therefore HCFC 22 can be used in pure or blended form. New Research in non-depleting substances is now focused on HFC (Hydroflurocarbons) and natural refrigerants 4,5. An HFC refrigerant does not contain any chlorine; hence have no ozone depletion effects. HFC134a and HFC152a in its pure and blended forms are being favorably considered for commercial and industrial refrigeration. But HFC do have varying global warming potential, therefore can not be considered a long term alternative. Natural refrigerants like Hydrocarbons (mainly propane and butane) have no ozone depletion potential and negligible global warming potential and are the best long-term alternative which can replace CFC. The Table 1 gives the comparison of environmental properties for R12 and it s possible alternative HCFC, HFC and natural refrigerants.

Property Refrigerant Table 1 : CFC12 and Alternative Eco-friendly Refrigerants ODP (ozone depleting potential ) GWP (global warming potential ) 1248 Toxicity Flammability CFC12 ( R12 ) 1 8500 no no HCFC22 (R22) 0.055 1700 no no HCFC142b(R142b) 0.0065 2000 no no HFC32 (R32) 0 580 no yes HFC125 ( R125) 0 3200 no no HFC134a (R134a) 0 1300 no no HFC152a (R152a) 0 140 no Yes** Ammonia (R717) 0 0 yes no Propane (R290) 0 3 no yes Butane(R 600) ** In very small range of concentrations Design specification of milk chiller Instant Milk Chilling Unit of Multai collection center has two units of 4000 liter capacity supplied by Alfa Laval Private Limited which cool the milk indirectly by chilled water from a big water tank. This type of refrigeration system is called Icebank refrigeration system and it works on R12. It is vapour compression refrigeration with evaporator coils submerged in water in a big water tank. When milk is received it is cooled by chilled water in plate type heat exchanger and kept in an insulated tank. The design and performance details of instant milk chilling unit designed for chilling 4000 Liters of milk per day from 35 C to 4 C are as follows 6 : Compressor : Freezking 750, 3 cylinder open type reciprocating compressor operating through belt drive at 580 rpm by a 7.5 hp induction motor and operates at plus 43 C condensing temp and minus 10 C evaporating temp on Freon 12 gas. The 0 3 no yes running time of compressor is 16 hours per day. Condenser : Air-cooled condenser with two air fans. Expansion Device : The Thermostatic expansion device of suitable length for operating between receiver and evaporator. Evaporator : Refrigerant R12 passes through submerged cooling coils in the 4000 Liters capacity water tank with all necessary fittings. The cooling capacity of the system is 12.31 kw. Performance evaluation of milk chiller Two sets of thermodynamic calculation 7 have been considered, Performance of the milk chilling unit with different refrigerants and same compressor as with R12. Performance of the milk chilling unit with different refrigerants to obtain same refrigerating capacity.

When a compressor designed for R12 is run with alternative refrigerant, it s volumetric efficiency will be affected and performance of the system will be changed 8. Volumetric efficiency = (1 + C) {Ps / P 1 } 1/n - {P d / P 1 } 1/n - 0.015 {Pd / P 1 } In which P s and P d are suction and discharge pressure inside the cylinder and P 2 and P 1 are condenser and evaporator pressure and n is the index of compression and expansion which is taken equal to γ. The results of thermodynamic calculations are presented in Table 2 to Table 4. Table 2 gives the values of properties data at design conditions, viz., NBP of refrigerants, pressure ratio, specific volume at suction conditions, and latent heat of vaporization at evaporator pressure and specific heat ratio for R12 and for alternative refrigerants. Table 3 lists the performance parameters for R12 along with alternative refrigerants which are chosen according to their boiling temp for comparing the performance of milk chilling unit when charged with these refrigerants in place of R12 using the same compressor. The thermodynamic properties of R12 and alternatives are taken from property generation software REFPROP version 6.0. Table4 gives the calculated performance parameters for R12 and new proposed refrigerants for the same refrigerating capacity of 12.31kW Simulation has been done by using vapour compression refrigeration design program Cycle D developed by National Institute of Standards and Technology, USA. Table 2 : Operating Properties data of R12 and proposed alternatives for t e = -10 C and t c = + 43 C Refrigerants NBP C Suction Volume in m 3 /kg H fg in kj/kg Specific heat ratio Volumetric Efficiency Suction Pressure (in psia) Discharge Pressure ( in psia) R 32-51.65.06301 330.26 1.13.783 84.48 386.45 R 290-42.76.1309 388 1.126.822 50.04 212.58 R 22-40.76.06527 212.78 1.116.686 51.45 239.12 R 12-29.79.07737 157.53 1.126.763 31.73 149.51 R 134a - 26.2.09959 205.95 1.102.679 29.09 159.66 R 152a - 25.1709 316.94 1.134.724 26.32 142.73 R 124-11.96.1392 164.91 1.13.686 15.94 93.44 R 600a - 11.73.3336 365.26 1.086.696 15.65 83.22 R 142b - 9.00.2144 223.24 1.135.675 14.11 82.37 R 600-0.54.5232 394.01 1.13.609 10.09 59.74 1249

Table 3 : Performance Results of R12 and New Proposed Refrigerants using the same compressor as with R12 in Milk Chilling Unit Refrigerants Mass flow rate kg / min Refrigerating capacity kw Compressor power kw COP Volumetric Refrigeration Capacity (kj/ m 3 ) Discharge Temp C R 32 8.81 33.04 8.75 3.87 2870.54 72 R 290 4.45 18.27 5.01 3.64 1547.29 48.95 R 22 7.45 18.09 4.72 3.88 1550.56 64.96 R 12 6.99 12.31 3.26 3.83 1044.50 50.6 R 134a 4.83 10.59 2.86 3.70 897.92 49.4 R 152a 3.00 11.25 2.82 3.95 945.60 59.8 R 124 3.34 5.87 1.46 4.01 337.68 43 R 600a 3.70 6.40 1.73 3.70 495.29 43 R 142b 2.23 5.80 5.76 3.97 490.26 48.6 R 600.825 3.66.938 3.90 508.98 43 Table 4 : Calculated Performance Parameters of R 12 and New proposed Refrigerants for the same refrigerating capacity of Milk Chilling Unit Refrigerant Mass flow rate Compressor power Piston Displacement V p (m 3 /min) V p / V 12 COP R 32 3.18 3.39 12. 022 0. 372 3. 64 R 290 3.00 3.39 23. 562 0.729 3. 64 R 22 4.98 3.24 19. 503 0.601 3. 80 R 12 6.99 3.23 32. 30 1 3. 83 R 134a 5.58 3.32 33. 343 1.032 3. 71 R 152a 3.30 3.13 33. 838 1.047 3. 93 R 124 7.02 3.28 58. 631 1.815 3. 75 R 600a 3.12 3.25 62. 449 1.933 3. 79 R 142b 4.74 3.10 60. 975 1.888 3. 97 R 600 2.76 3.15 86. 642 2.682 3. 91 1250

RESULTS AND DISCUSSION From Table 3, it is clear that refrigerating capacity of milk chilling unit is affected when existing R12 compressor itself is used with new proposed refrigerants. This is mainly due to change in mass flow rate of the refrigerant, which is decided by the volumetric efficiency and suction vapour volume at inlet to compressor. The latent heat of vaporization can have either a positive or negative effect on the refrigerating capacity of the unit. The higher boiling refrigerants R32, R290 and R22 give very high refrigerating capacity than the refrigerants with lower boiling temps and therefore could be possible substitute. R152a and R134a have small capacity difference and could be possibly used with increased run time. With same compressor R124, R142b and butane perform better with increased COP and smaller compressor power but can not be used due to their very small refrigerating capacity. R32 and R22 give better COP but consume more power as compared to R12. The isentropic temp at the outlet of cylinder is also tabulated in Table 2 and both R32 and R22 have comparatively high temp as compared to R12 and will require extra cooling to protect the compressor from overheating. From Table 4, it is clear that for same cooling effect, Refrigerants R152a, R142b and R600 give best results in the milkchilling unit. Their COP and power consumption is better as compared to R12 but R142b and R600 require very high displacement volume therefore will require bigger compressor than R12. R152a requires only 4.7 % more volume and can be used in the system if its volumetric efficiency can be matched to give equal displacement. All other refrigerants have smaller COP and higher consumption of power. R22 has very small performance difference but require 40% small compressor for working in place of R12 in the refrigeration system of milk chilling unit. It is clear from the performance evaluation of pure refrigerants that no single refrigerant can be used to retrofit the milk chiller by replace R12. The requirement for retrofitting an existing system with a refrigerant with matching and desired properties has resulted in evolution of refrigerants blends of more than two or three refrigerants. The blend of a flammable refrigerant with a inflammable refrigerant can result in a mixture which is inflammable. Also for fulfilling retrofitting condition, binary mixture of a higher volumetric refrigeration capacity can be combined to a lower capacity fluid to give a matching volumetric refrigeration capacity to allow the compressor to work without any problem. Also HFC refrigerants can be combined with HCFC refrigerant to make them compatible with the lubricant used with R12.There has been case studies of milk chillers which have been retrofitted with refrigerant blends MP39, MP33 and FX56. For the retrofitting of the milk chiller, the following refrigerant blends have been analyzed for selecting the alternative for R12. Their performance results are tabulated in Table 4. 1251

Table 4 : Comparison of performance results of R12 and some refrigerant blends in the milk chiller R12 Refrigerants Trade name Freon Compressor power (kw) 3.26 C.O.P. 3.83 Suction/ Discharge pressure (Kpascal) 218.8/1031 Mass flow rate (Kg/min) 6.99 Volumetric Refrigeration Capacity ( kj/m 3 ) 1044.9 R22/R152a/R124 (.53/.13/.34) R22/R152a/R124 (.36/.24/.40) R22/R124/R142b (.60/.25/.15 ) R152a/R290 (.96/.04 ) MP39 MP33 FX56 3.24 3.21 3.23 3.18 3.80 3.83 3.81 3.87 240.1/1233.5 205.8/1093.6 237.3/1222.6 194.3/1054.5 5.47 4.97 5.34 3.74 1173.8 1041.0 1178 1068.2 The performance is best with R152a/R290 blend with very improved performances but this mixture is not available commercially in the market. From the commercial available blends MP33 has a matching volumetric capacity to R12 and it performs better with reduced power consumption. It s operating pressures are also matching to the operating pressures of R12 system and therefore will require only small readjustment of the valve setting. Being a R22 based blend, it is also compatible to lubricant and other material component of systems currently used in the milk chiller. The only precaution for operating with the MP33 is the prevention of leakage from evaporator or condenser as it may change the composition of the refrigerant. CONCLUSION refrigerant with higher system performance and an equal matching compressor displacement. It has no Ozone Depletion Potential and comparatively small Global Warming Potential. With all other pure refrigerants, the system will be required to be modified as per the performance results of the system with that refrigerant Therefore it is suggested that milk chiller may be operated by retrofitting it with either MP33 or R152a/R290 blend for making it possible to operate after the phase out of R12. ACKNOWLEDGEMENT The research was carried out at Rajiv Gandhi Technical University, Bhopal in association with Bhopal Dugdh Centre, Habibganj of Madhya Pradesh State Dairy Co-operative Federation. Bhopal. Out of the 9 proposed refrigerants, none REFERENCES can be used as a drop in substitute in place of 1. James M. Calm and David A. Didion R12 in the refrigeration system of milk Trade off in refrigerant selection past, chilling unit. As per the analysis R152a present And future Int. J. Refri., 21(3), emerges as one of the most promising 308-321, (1998). 1252

2. Technical Data Collected from Head Office,Bhopal Dugdh Sangh, Habibganj, Bhopal. (2009). 3. Jung D.S. and Radermacher R., Performance simulation of single evaporator domestic refrigerators charged with pure and mixed refrigerants, International Journal of Refrigeration, 14(1), 223-231, (1991). 4. McLindon M.O., Thermodynamic Properties of CFC Alternatives: A survey of the available data, International journal of refrigeration, 13(3), 149161, (1990). 5. Agrawal Alka and others, Alternatives to Ozone Depleting Substances A Discussion of Options, Proceeding of 20th IIR international congress of Refrigeration, Sydney, Australia, 156-162, Sept19-24, (1999). 6. Freezing Compressor Data from Technical Brochure of Alfa Laval milk chillers, Alfa Laval Private Limited, Pune, India. 7. Ashok Babu T.P., Design modifications needed in the compressor for Using Alternative Refrigerants to R12, IIR conference on Emerging Trends in Refrigeration and Air-conditioning, New Delhi, India, 171-181, March 18-20, (1998). 8. Arora C.P., Text book Refrigeration and Air-conditioning, Second Edition, Tata McGraw Hill, Ch6- Refrigerant compressor, 258-259, (2000). If U Protect NATURE NATURE will Protect U 1253